Tender For Supply Of Outdoor Unit 24 Hp (12+12+ Refnet) (Model Rxyq12ary6+Rxyq12ary6) Sdgt For Outdoor Vrv Indoor Unit Vrv 4-Way Cassette With Cardless Remote & Refnet Capacity -4.12Tr (Model-Fxfsq125) Capacity -3.3Tr (Model-Fxfsq100) Capa, Medininagar-Jharkhand
Tender Notice
49559517
Tender For Supply Of Outdoor Unit 24 Hp (12+12+ Refnet) (Model Rxyq12ary6+Rxyq12ary6) Sdgt For Outdoor Vrv Indoor Unit Vrv 4-Way Cassette With Cardless Remote & Refnet Capacity -4.12Tr (Model-Fxfsq125) Capacity -3.3Tr (Model-Fxfsq100) Capa
Tender
Indian
Jharkhand
Medininagar
17-06-2025
Tender Details
Tender For Supply Of Outdoor Unit 24 Hp (12+12+ Refnet) (Model Rxyq12ary6+Rxyq12ary6) Sdgt For Outdoor Vrv Indoor Unit Vrv 4-Way Cassette With Cardless Remote & Refnet Capacity -4.12Tr (Model-Fxfsq125) Capacity -3.3Tr (Model-Fxfsq100) Capacity -2.6Tr (Model-Fxfsq80) Vrv Split Unit With Cardless Remote & Refnet Capacity -1.3 Tr (Model-Fxaq40) Installation Of Outdoor Unit With Proper Vibration Isolation, Testing And Commissioning Of The System. Copper Piping Work Suction Line With Closed Cell Nitrate Rubber & Necessary Support Liquid Line With Closed Cell Nitrate Rubber & Necessary Support Refnet Joint Installation Sitc Of 2Cx 1 Sqmm Copper Cable With Pvc Conduit Sitc Of Pvc Drain Pipe With Support 25Mm Dia 40Mm Dia Extra Refrigerent Charging With Proper Vaccumising Specification & Model And Supply, Installation Testing & Commissioning Of Modular Type Variable Refrigerent Flow/Variable Refrigerent Volume Air Cooled Outdoor Unit With R 410 A Refrigerent, Variable Isolator With Suitable Foundation Etc. Complete As Required. The Unit Shall Diliver The Rated Caacity At Ahri Condition & Work Even At 49 C Ambient Temperature Without Tripping. The Unit Shall Be Suitable To Work On 400V +/-10% 3 Phase,50 Hz Ac Power Supply. The Unit Shall Be Filled With First Charge Of The Refrigerent And Ready For Use As Required.Ms/Gi Powder Coated Stand With Vibration Isolation Pads. The Unit Should Have Refrigerent Cooled Pcb For Better Life Of System .Compressor Motor Should Have More Than 4 Poles. The Odu Shall Have Low Noise Condeser Fans With External Static Pressure Of The Outdoor Unitshall Be More Than 75 Pa To Avoid Hot Air Recirculation Auto Address, Auto Refrigerant Charging, Auto Cheak Function, For Connection Error, And Complete With Indoor And Outdoor Unit With Individual Controller And Fitting Etc
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.