Inner Electrification Including Sub-Station Other Allied Items Of Admin Block At Medicity Bemina - 1 Note: Contractor should Quote Rates with all taxes. 2 Part - B (Electrical & allied works) 3 Wiring for light/fan/exhaust fan point with 1.5 Sq.mm FRLS PVCinsulated copper conductor single core cable including/existingmedium class PVC conduit 25 mm x2mm thick with 10 Ampmodular switch ,modularCover plates and also suitable size G.I box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc.as required. 4 SWiring for light/power plug with 2x4 Sq.mm FRLS PVC insulated copper conductor single core cable along with 1 No.4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Including suitable size` medium class PVC conduit. 5 Circuit/Sub main wiring;Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor single core cable. Including suitable size PVC conduit as required. CKT wire from DB to SB 6 (2x2.5 Sq.mm+1x2.5 Sq.mm) 7 (2x6 sq.mm+1x6Sq.mm) 8 (4x16sq.mm+2x6 Sq.mm) from panel to D.B 9 2x1.5sq.mm+1x1.5Sq.mm) 10 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amp modular socket outlet and 15/16 amp modular switch, connection etc.as required(Complete job) 11 Supplying, Installation, Testing and Commissioning of ceiling fan 1200 mm sweep copper wound including suitable size down rod, electronic fan regulator for speed controlling with 1.5 sq.mm FRLS insulated copper conductor for connections with fixing of phenolic laminated sheet cover on the fan box 12 SITC of 15 watt led panel/surface lights 13 Supply of exhaust fan 200/250 mm swee 14 Installation of exhaust fan in existing opening, including making good the damage ,connection ,lesting scommissioning etc. as required Up to 450 mm sweep 15 Supplying and fixing 3pin,5Amp ceiling rose on junction box including square block / round sheet connection ete.as required 16 Earth wire:Supplying and fixing of 6 SWG G.I wire at 0.50Mtr.below ground level for conductor earth electrode including connection/termination with copper thimble etc. as required (for panel and servo stabilizer) from Earthplate to Panel 17 Supplying and fixing 6-32 amp rating 240/415 v 10 KA,C Curve Miniature circuit breaker single pole suitable for Inductive load of following poles in existing MCB DB complete with connections ,Testing and commissioning etc. as required. 18 Single pole 19 Double pole 20 Supplying and fixing C Curve Miniature circuit breaker 63 Amp. 4 Pole 21 Providing, supplying and fixing of D.B box 8 way TPN. 22 Power Cable:Supply, laying, Testing and commissioning of Following sizes 1.1 KV. Grade aluminium conductor PVC Sheathed armoured cable in ground including digging of trench providing of sand and brick protection and back filling as required and also including thimbles3. 5 core x 70 sq.mm 23 Fabrication, wiring, Supply installation, testing and commissioning of front Operated Cubical type panel board 4 pole outgoing 4 pole incoming made of]4 SWG MS Sheet painted with one coat of primer and two coat of paint, complete with earthing bus neutral link drilling holes on the board and consisting of the following pane] board be grouted 0.5 feet underground and 1.5 fect above ground level the foundation legs be covered by all sidesa.MCCB 4 pole 400 amp 50 KA- INob.RCBO 4 pole 63 Amp — 12Noc.Aluminium Bus bar 400 Amp — | setd.Phase indicator RYB 1 sete.Phase indicator RYB 3 setsf.Multifunctional 3 phase digital meteg.MCB 63 Amp 4 pole 12 no’s.h.Change over 4 pole 200 amp. 2 no’s 24 Servo StabilizerFabrication, supply, erection, testing and commissioning of 30 KVA 3 phase servo controlled automatic voltage regulator transformer with Buck boost transformerInput voltage 240-450 p-pOutput Voltage 400V p-p 230 N-POver load protection3phase digital meterSingle phase preventerUnder voltage protectionHigh voltage protectionDelay line outputMaterial CopperAll protections through micro controllerOil CooledUn-balanced typeThe stabilizer shall be provided with first filling of fresh transformer oil.Sheet gauge used for fabrication of stabilizer should not be less than 14 SWGSpeed of correction should not be less than 10 -20 volt per second efficiency more than 90% 25 Supply/fixing /installation ofcopperbus bar 200 amp with sheet steel Box including 400 amp MCCB 4 Pole 50 KA (complete job) 26 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm 27 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm 28 Supply and Fixing of 16 way MCB Distribution box 29 Cable: Supply, laying, Testing and commissioning of PVC insulated, PVC sheathed/XLPE Power cable of 1.1 KVA grade of following sizes 0.75M below ground including digging of trench 0.35M wide 0.75 M depth, protection with SN4 DWC HDPE PIPE 75mm and refilling the trench, etc. as required complete Job the cable should be joined with Aluminum Lugs as reqd.10 sq. mm 4 core 30 SITC of 2’x 2’x1” feeder pillar with 4 pole 32amp MCB C curve - 4 no, 4pole bus bar 100 amp, locking arrangement including 3 feet height angle iron stand above the ground level and 1 feet below the ground etc .connections as required. 31 Servo StabilizerFabrication, supply, erection, testing and commissioning of 40 KVA 3 phase servo controlled automatic voltage regulator transformer with Buck boost transformer Input voltage 240-450 p-pOutput Voltage 400V p-p 230 N-POver load protection3phase digital meterSingle phase preventerUnder voltage protectionHigh voltage protectionDelay line output Material CopperAll Protections through micro contriller Oil CooledUn-balanced typeThe stabilizer shall be provided with first filling of fresh transformer oil.Sheet gauge used for fabrication of stabilizer should not be less than 14 SWGSpeed of Correction should not be less than 10-20 volt per Second efficiency more than 90% 32 Providing/Fixing/commissioning/testing of 100 KVA_ outdoor type Three phase Oil immersed 11K V/433-250V,50 HZ Aluminum wound energy efficient Distribution Transformer of Energy Efficiency Level 2 -3 Star. 33 P/F of channel iron 100mm x 50mm x 6mm ( 9.56 kg/mtr.) 8 ft. long cross arm including, bolts, nuts and washer and necessary clamps for insulator pins having base coat of red oxide and two coats of silver white paint as required 34 P/F of channel iron 100mm x 50mm x 6mm ( 9.56 kg/mtr) 10.5 ft. long cross arm complete with 50mmx50mmx6mm angle iron bracket welded to thechannel iron and complete iron and complete with 50mmx6mm M.S flat iron clamps, bolts, nuts and washer etc. Including drilling of holes for insulatorpins having base coat of red oxide and two coats of silver white paint as required. 35 P/F of 11 Kv pin insulators with pins, nuts washers etc. (complete Job) (10 KN) 36 P/F and testing of Gang operating Disconnect or switch with copper strips (11K V) with all accessories including suitable G.I pipe (complete job). 37 P/F of Alm. Lugs of required sizes 38 P/F of Galvanized Anti-climbing Devices on H.T Poles at a height of 2.5 mtr above ground level. (Barbed wire 3.5 KG) with 4 No’s M/s Clamps for each plate. 39 Supplying and fixing of danger plates of 250mm x 200mm made of mild steel at atkeast 2mm thickand vitrous enamled white both sides with inscriptions in single red color on front side as required on Htoles at a height f 2.5 Mtrs above groundlevel. 40 supply Installation testining & commissioning of Maintenance free hot deep galvanized on 250 microns GI Earthing System with 10 ft long, 80 mm dia &3.0mm wall thickness. (pipe-inpie with flat terminal) technology with 2 bag of electron high conducive & anti corrosive compound spec.: 3 mtr length x 80mm dia / 2.96 mm thick / 250 micron electrode thicknss: 3.0mm / ISI class - B, Hot dip galvanized 250 microns terminal size shoukd be 40 x 10mm thick and also providing machinery enclosure with cover plates having locking arrangement & water piping of 2.7 mtr. long. 41 Providing & Fixing of11 KV drop out set. 42 Providing first aid safety box as per requirement. 43 Providing & Fixixng of 25mm X 6mm GI strip including bobbin, insulators, connection / terminals with GI nut bolt spring washers clamps etc., as required 44 P/F of 11 KVA post-operative lightenng Arrestor set. 45 Providing Fixing Testing & Commissioining of tri Vector meter with desired CT/PT coils on HT side incuding all accessories for substtion & all other formalities with PDD to be done by contractor including inspection etc., as required (GR) 46 P/F of 185 Sq. mm. 3.5 core armored cable PVC sheathed, steel armored cable 0.75M below ground including digging of trench 0.35M wide 0.75M depth, providing of double wall corrugated (DWC) 75mm made of HDPE material pipe for cable protection 47 P/F of mccb 400 Amp with single door type sheet steel box including three phase Amp., mtr and volt Mtr., & Al. bus bar 250 Amp with selector switches (weather proof) complete job. 48 P/F of 11 KV ABC armored XPLE cable 3 x 35 Sq. mm 49 P/F of heat shrinkable kit for 35 Sq. mm ABC cable 50 Providing & Fixing of 11 KV strain disc insulators with pins (complete job.) 51 Providing & Fixing HT steel tubular poles swaged type pole fitted with base plate. Pole designation 410-SP 33.9 Mtr. Height cap ontop wit base coat painting of red oxide and two coats of silver white paint. Te execution of pole pit up to 5 ft. dee & refillin the same after erection of pole. cement bottoming of steel tubular poles, 2x2x6 in the ratio of 1:3:6 mi (1 cement : 3 coarse sand : 6 graded aggregate stone 40mm nominl size) Te foundation block shall be laid 5 below ground level and 1 aove ground level with surface with 1mm thick cement plater in 1:4 mix (1cement : 4 coarse sand) 52 Providing & Fixing of alumunium conductor 0.05 Sq. inch ACSR (Rabbit) 53 P/F of channel iron 100mm x 50mm x 6mm (6kg/mtr) 5ft long cross arm including bolts, nuts and washers and necessary clamps for insulator pins havin base coat of red oxide and two coats of silver white paint as required.