Tender For Provision Of Ei Fan And Otherallied Works At Singhola Landfill Site; 1 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. 2 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 3 1.8.3:Wiring for light point/ fan point/ exhaust fanpoint/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, withpiano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single corecable etc as required.Group C 4 1.23.1:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch 5 1.23.4:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 amp socket outlet 6 1.23.3:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.15/16 amp switch 7 1.23.5:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 amp socket outlet 8 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator 12 way, Double door 9 2.12.2:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 10 1.50.1:Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep 11 1.51:Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes 12 122.1.47:Supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required. 13 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, Ccurve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole 14 Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. complete in all respect i/c mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)18-22 Watt 15 S/I/T/C of 4 KVA Voltage Stabilizer having input voltage 150V-270V and output voltage 195-245V 16 SITC of wall mounted fan 400mm sweep rated voltage 220-230 AC rated frequency 50HZ speed 1280-1350 RPM with desired color 17 S/I/T/C of 2 TR, 2 star/3 star, window air conditioner having copper condenser coil, rotary compressor and R32/better refrigerant. 18 1.14.4:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire 19 1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 20 2.18:Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 21 1.30:Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 22 1.12:Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 23 Supplying AND Installation of Reverse Osmosis (RO) water purifier of capacity 50 ltr/hr complete as required. 24 Supplying and fixing of full stainless steel body self-contained drinking water cooler with cooling capacity 150ltr per hr, storage capacity 150ltr and suitable for 230V supply as required. 25 supply and fixing of 4.5 KG DCP with CO2 gas cartridge fire extinguisher (conforming to IS:2171 with cylinder fully charged) 26 Boring/Drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS:2800 (part-I), including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-Charge, up to 90 meter depth below ground level.(a) Up to 115 mm dia 27 Supplying, assembling, lowering and fixing / placing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS 12818, including required hire, and labour charges, fitting and accessories etc. all complete, for all depths, as per direction of Engineer in Charge. (a) 100 mm (Nominal Bore) 28 Supplying, assembling, lowering and fixing / placing in vertical position in bore well, unplasticized PVC medium well screen (RMS) pipe with ribs of required dia, conforming to IS 12818, including required hire, and labour charges, fitting and accessories etc. all complete, for all depths, as per direction of Engineer in Charge. (a) 100 mm (Nominal Bore) 29 Gravel packing in tube well construction in accordance with IS:4097, including providing gravel fine/medium/coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-Charge. 30 Supplying and fixing following sizes ball plug at bottom of pipe comp as reqd .(a) 100 mm dia. 31 S&F MSclamp made up of iron flat of size 50mmx 6 mmwith 4 nut bolt for holding the 100 mm to 150 mm dia pipe etc as reqd 32 Providing and laying cement concreat 1:2:4 mix for sanitary sealing of well at top of 450mmX 450mmX 500 mm deep fromtop comp as reqd. 33 Development of tube well with suitable capacity of air compressor i/c lowering of the necessary induction pipe or linei/c cost of fuel, hire charges of compressor etc as reqd. The development shall be considered complete when Gravel stop sinking, Discharge ceased to improve and the sand contents are not more than 10 PPM after 20 minutes of starting the pump complete as reqd. 34 Supplying, lowering, testing and commissioning of following capacityvertical type, multistage, totally enclosed, water filled, deep well submersible pumping set completei/c connections etc as reqd. (a) Single phase 1.5 HP, having discharge of 72 LPM (approx.) at 49 M head. 35 Supplying and Fixing of following sizes of insulated steel flexible safety rope suitable for holding submersible pump set i/c clips etc as reqd. (a) 6 mm dia steel rope. 36 P&F following sizes of PVC insulated & PVC sheathed copper conductor 3 core submersible cable confirming to IS.694/1990 etc. as reqd. (a) 3 X 2.5 sq.mm. 37 Supplying, lowering and fixing following size of G.I. Pipe (M- Class) i/c cutting threading on both sides etc ISI marked etc as reqd. (a) 25mm dia 38 (b) 32 mm dia 39 S& F following sizes ofGI Elbow as reqd. (a) 25mm dia. 40 (b) 32 mm dia 41 S&F following sizes ofGI socket as reqd. (a) 25mm dia. 42 (b) 32 mm dia 43 S&F following sizes ofG.I. unionsocket as reqd.(a) 25mm dia. 44 (b) 32 mm dia 45 S&F following sizes ofGun metal Gate Valve as reqd.(a) 25mm dia. 46 S&F MS clamp made up of flat iron of size 50mmx 6 mm with 4 nut bolt for holding theG.I. Pipe as required(b) 50mm. 47 Supply, Installation, testing and commissioning of cubical type control panel board for single phase submersible pumping set of following rating complete with contactor, relay , MCB ,condenser ,voltmeter, ammeter and indication lamp etc includingconnections etc as reqd. (a)1.5 H.P rating Submersible P/Set. 48 Supply & Fabrication of pole protection system made up of 8SWG steel wire mesh of size 25mmx75mm rectangular with 50mmx50mmx6mm MS Angle iron for supporting the mesh and grounding the protection system in suitable quality of CC etc as reqd.