| 1 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End ) |
| 2 | Supply and fixing of single box type 1x18w 4 feet LED Fitting without LED Tube complete with TW round blocks on wall or ceiling with18 W LED tube light with double side connection ( Havells / equivalant)with PVC unsheathed Copper leads from terminals to the fitting. |
| 3 | supply and fixing of 1200mm (48\") sweep AC ceiling fan complete (Higher end) with 2 module 100W fan step regulator (Higher end) with 300mm down rod with fan clamp with side plates and cross arm of size 450mm (18\") |
| 4 | Supply and fixing of 300 mm (12\") sweep (light duty) AC exhaust fan complete without Provision of Hole in the Wall. |
| 5 | Supply and fixing of louvers shutters arrangements for 300mm (12\") sweep (light duty) AC exhaust fan |
| 6 | Supply and fixing of 3nos.6A two module 5 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End |
| 7 | supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End |
| 8 | supply and fixing of 60W LED street light fitting with LED (Lower end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting . |
| 9 | Supply and run of 2 of 4 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour. |
| 10 | Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCBswitch as incoming and 10 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only.The MCB DB and MCB’s should be like Standard Make |
| 11 | Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming and 2 Nos 32A 3P MCB 12 nos. 6A to 32A SP MCB & 6 Nos dummy plate as outgoing on wall with earth connection only. |
| 12 | Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 100 A 4P MCB Isolator as incoming and 7 nos. 63A 3P MCB and 3 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only.[MASTER DB] |
| 13 | Supply and Run of 2 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. |
| 14 | Supply and fixing of 4 MP POE IP Bullet/Dome Camera |
| 15 | Supply and run of 1 ofCAT 6 cablein suitable PVC rigid pipe on wall and ceiling with painting of suitable colour. |
| 16 | Supply and fixing of network video recorder for CCTV |
| 17 | Supply and fixing of PoE Switches for CCTV IP camera |
| 18 | Supply and fixing of Hard disk for NVR |
| 19 | Supply and fixing of 4 U rack |
| 20 | Supply and Fixing of LG 80CM(32 Inches) HD Ready Smart LED TV 32SR50F-W |
| 21 | Supply and clamping of 4 x 16 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps |
| 22 | Supply and Laying of 3 1/2x 35 sq.mm PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. |
| 23 | Supply and clamping of 3 1/2x 35 sq.mmPVC armoured LTUG cable on post on wall with MS clamp. |
| 24 | Supply and Fixing of brass cable gland for3 1/2 x 70 sq.mm PVC armoured LTUG cable with earth connection |
| 25 | Supply and Providing cable end termination 3 1/2 x 70 Sq.mm PVC LTUG aluminium armoured with necessary aluminium cable socket by crimping ect with electrical connection complete |
| 26 | Supply and Fixing of brass cable gland for3 1/2 x 50 sq.mm PVC armoured LTUG cable with earth connection |
| 27 | Supply and Laying of 3 1/2x 70 sq.mm. PVC armoured LTUG cablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. |
| 28 | Supply and clamping of 3-1/2 x 70 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps. |
| 29 | Earthing as per the ISI specification with an earth electrode of 2.1mt class \"B\" GI pipe of dia not less than 40mm, with copper earth plate of size 125mmx50mmx6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry. |
| 30 | Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection |
| 31 | GST @ 18 % |