Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 23-06-2025 | Corrigendum-1 | Date | 25-06-2025 |
| Sl. No. | Item Description |
| 1 | EXCAVATION upto 1.50 Metre for foundation such as footing, pedestals, walls, drains, columns, ramps, plinth beams, cable trenches in dense or Hard soil MECHANICALLY but other than hard rock including shoring, strutting, sorting out and stacking useful material, dewatering where required, cutting vegetation up to 1.5m ht if required and disposing off the excavated stuff upto all lead and lift.Note- All types of soil that can be removed by JCB/ Poclain bucket shall be classified under this item. |
| 2 | EXCAVATION 1.50 to 3.00 Metre for foundation such as footing, pedestals, walls, drains, columns, ramps, plinth beams, cable trenches in Hard Murrum MECHANICALLY but other than hard rock including shoring, strutting, sorting out and stacking useful material, dewatering where required, and disposing off the excavated stuff upto all lead and lift. |
| 3 | EXCAVATION 1.50 to 3.00 Metre for foundation such as footing, pedestals, walls, drains, columns, ramps, plinth beams, cable trenches in Soft rock not requiring blasting but other than hard rock including shoring, strutting, sorting out and stacking useful material, dewatering where required, and disposing off the excavated stuff upto all lead and lift |
| 4 | FILLING with selected & approved available excavated earth (excluding rock) in excavated pits, trenches, in plinth, sub-base for of roads,drains, manhole, sumps, or where required with approved locally available materials including spreading in layers not exceeding 200mm, watering, ramming, compacting mechanically using 2 ton compactor etc, complete.Measurements for net volume of space occupied by filling.If desired by the engineer-in-charge the contractor shall at his own expense carry out modified proctor compaction test to determine the maximum dry density.The criteria for acceptance of filling shall be compacting to 95% modifiedProctor density with use of mechanical roller/rammer etc complete as directed and instructed by Engineer-in-charge. Volume of material filled to be measured for payment. |
| 5 | FILLING with selected & approved Murrum material brought by Contractor from outside client\"s premises, including Identification ofBorrow pits and including Royalty charges & or duties as per requirement oflocal authority, in foundations, excavated pits, trenches, in plinth, sub-base for of roads,drains, manhole, sumps, or where required with approved locally available materials including spreading in layers not exceeding 200mm, watering, ramming, compacting mechanically using 2 ton compactor etc, complete.Measurements for net volume of space occupied by filling.If desired by the engineer-in-charge the contractor shall at his own expense carry out modified proctor compaction test to determine the maximum dry density.The criteria for acceptance of filling shall becompacting to 95% modifiedProctor density with use of mechanical roller/rammer etc complete as directed and instructed by Engineer-in-charge. Volume of material filled to be measured for payment. |
| 6 | Providingandlaying-600mmthickFiltermediadirectedatthebackofabutments, returns and wing walls as per detailed specifications. Well graded pebbles or metal of 40 mm. to 63 mm. size shall be used.The grading & tolerances of metal or pebbles should be as under.Sr. No. No. ofsize range Sieve designation Percentage byweightpassing through the sieve, below mentioned in squence as size range, 2. seive designation, 3. % by wieght passing through seive 1. 63 mm. To 40 mm. 90 mm 100-502. 63 mm 85-1003. 50 mm 35-704. 40 mm 00-155. 20 mm. 00-05The size shall be 40 mm to 63 mm. The tolerance limit for oversize shall be up to 15%, and that for lower size should be up to 15% and below 20 mm. It shall be allowable up to 5%. The filter material shall be tightly placed to a thickness not less than 600 mm and provided over the entire surface behind abutments wings or return walls to the full height.The measurement for payment shall be made on a Sq M basis.The unit rate includes the cost of materials, scaffolding, labour & tools to complete the work as per the instruction of engineeri-in-charge |
| 7 | Providing and laying RUBBLE SOLING wherever required in foundation and plinth including hand packing fillings interstices with chips and sand.Watering and compacting to consolidated thickness, etc complete as directed by engineer-in-charge |
| 8 | Providing material and labour for laying PLINTH PROTECTION including excavation of 30 cm depth and Filling with dry bricks bats of 20 cm thick and top layers C.C. 1:2:4 ( 1 cement 2 coarse sand: 4 graded stone aggregate 20m nominal size)50mm thk finished in proper grade and slop etc. completeas directed by engineer-in-charge |
| 9 | Carring out plinth treatment to post construction / existing structure by spraying chemical solution for termite control treatmentincluding labour and material consistment with I.S.I specification.Using Chlordene and Chiorpurfiles 20 EC. As Per 6131_paret-II Consentration Weight one percent is recommended i.e one litre 20 EC chemical emulsion with 19 liter give 1 % concrentration inclusive of one litre chemical emulsion appication at the rate of 5 Litre chemical / Sqm of surface is recommended as per I.S. treated Plinth area of structureto be measured for payment as directed by engineer-in-charge |
| 10 | Providing and laying PLAIN CEMENT CONCRETE 1:2:4 (1- Cement : 2- Coarse sand : 4- gradedstone aggregates 20 mm nominal size) in foundations and superstructure including, machine mixing, leveling compacting, curing and formwork if any, scaffolding, stagingetc. complete as directed and instructed by Engineer-in-Charge. Volume of PCC laid to be measured for payment. |
| 11 | Providing material and labour for laying machine mixed/machine batched/RMC controlled cement concrete M.250 using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregate confirming to IS 383 with minimum cement content as per IS456 (without flyash) for durability shall be followed as per approved design mix & latest IS456 for reinforced cement conrete work for all elements,all floors,all heights/depths, any lead and lift including cost of formwork with sheathing steel , scaffolding, staging, vibrating, compacting, finishing andcuring complete but excluding cost of reinforcement for reinforced concrete work in Foundations,footings, Baseof columnsandMass concrete, as directions of Engineer in charge Complete.Preliminary cubes to be prepared on award of work and to be tested to meet the specified requirement for M25 mix, design mix to be approved by the Engineer-in-charge/Architect. Concrete placing shall be done with utmost care, the free drop height shall not exceed 1.5m, and concrete shall be vibrated with immersion type vibrators having frequency not less than 7000 vibrations per second in methodical method so as all points of structures are covered. Free concrete surface shall be covered with Hessian cloth and kept wet. |
| 12 | Providing material and labour for laying machine mixed/machine batched/RMC controlled cement concrete M.250 using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregate confirming to IS 383 with minimum cement content as per IS456 (without flyash) for durability shall be followed as per approved design mix & latest IS456 for reinforced cement conrete work for all elements,all floors,all heights/depths, any lead and lift including cost of formwork with sheathing steel , scaffolding, staging, vibrating, compacting, finishing andcuring complete but excluding cost of reinforcement for reinforced concrete work in Columns, Pillars posts and struts etc complete as directed by Engineer-incharge.Preliminary cubes to be prepared on award of work and to be tested to meet the specified requirement for M25 mix, design mix to be approved by the Engineer-in-charge/Architect. Concrete placing shall be done with utmost care, the free drop height shall not exceed 1.5m, and concrete shall be vibrated with immersion type vibrators having frequency not less than 7000 vibrations per second in methodical method so as all points of structures are covered. Free concrete surface shall be covered with Hessian cloth and kept wet. |
| 13 | Providing material and labour for laying machine mixed/machine batched/RMC controlled cement concrete M.250 using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregate confirming to IS 383 with minimum cement content as per IS456 (without flyash) for durability shall be followed as per approved design mix & latest IS456 for reinforced cement conrete work for all elements,all floors,all heights/depths, any lead and lift including cost of formwork with sheathing steel , scaffolding, staging, vibrating, compacting, finishing andcuring complete but excluding cost of reinforcement for reinforced concrete work in Lintels,Beams,Girders and Cantilever etc complete as directed by Engineer-incharge.Preliminary cubes to be prepared on award of work and to be tested to meet the specified requirement for M25 mix, design mix to be approved by the Engineer-in-charge/Architect. Concrete placing shall be done with utmost care, the free drop height shall not exceed 1.5m, and concrete shall be vibrated with immersion type vibrators having frequency not less than 7000 vibrations per second in methodical method so as all points of structures are covered. Free concrete surface shall be covered with Hessian cloth and kept wet. |
| 14 | Providing material and labour for laying machine mixed/machine batched/RMC controlled cement concrete M.250 using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregate confirming to IS 383 with minimum cement content as per IS456 (without flyash) for durability shall be followed as per approved design mix & latest IS456 for reinforced cement conrete work for all elements,all floors,all heights/depths, any lead and lift including cost of formwork with sheathing steel , scaffolding, staging, vibrating, compacting, finishing andcuring complete but excluding cost of reinforcement for reinforced concrete work in Slabs, landing, shelves and Cantilever etc complete as directed by Engineer-incharge.Preliminary cubes to be prepared on award of work and to be tested to meet the specified requirement for M25 mix, design mix to be approved by the Engineer-in-charge/Architect. Concrete placing shall be done with utmost care, the free drop height shall not exceed 1.5m, and concrete shall be vibrated with immersion type vibrators having frequency not less than 7000 vibrations per second in methodical method so as all points of structures are covered. Free concrete surface shall be covered with Hessian cloth and kept wet. |
| 15 | Providing material and labour for laying machine mixed/machine batched/RMC controlled cement concrete M.250 using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregate confirming to IS 383 with minimum cement content as per IS456 (without flyash) for durability shall be followed as per approved design mix & latest IS456 for reinforced cement conrete work for all elements,all floors,all heights/depths, any lead and lift including cost of formwork with sheathing steel , scaffolding, staging, vibrating, compacting, finishing andcuring complete but excluding cost of reinforcement for reinforced concrete work in WALLS from top foundation level to all levelsetc complete as directed by Engineer-incharge.Preliminary cubes to be prepared on award of work and to be tested to meet the specified requirement for M25 mix, design mix to be approved by the Engineer-in-charge/Architect. Concrete placing shall be done with utmost care, the free drop height shall not exceed 1.5m, and concrete shall be vibrated with immersion type vibrators having frequency not less than 7000 vibrations per second in methodical method so as all points of structures are covered. Free concrete surface shall be covered with Hessian cloth and kept wet. |
| 16 | Providing, laying and fixing in position REINFORCEMENT High yield deformed bars/TMT/ FE500/FE500D/FE550 forR.C.C. works at all levels including cutting, bending and binding with 16 gauge M.S. annealed wire, providing cover blocks of C.M. 1:2 Embedded with binding wire etc. complete. The reinforcement detailing to IS 456 or, if specified by engineer, shallconformto IS: 13920 (Ductile detailing of R. C. Structures),bars as per IS 1786 the rate shall be inclusive of executing such detailing. Laps to be measured shall be as shown in drawing and for reinforcement length longer than available in market. Chairs, pinsand laps other than that specified shall not on be measured and paid for. No extra to be paid for height, rate remains same at all levels, complete as per drawings, specification, direction ofengineer-incharge. Make: TATA, SAIL, JSW or as approved byengineer-in-charge Complete. |
| 17 | Providing material and labor for Structural steel work (Confirming to IS 4923-1997) riveted, bolted or welded in builtup for all type sections, in framed work, including cutting, hoisting, fixing in position and applying a priming coat &two coat applying synthetic enamel paint of approved steel primer all complete as per the structural designs and as directions ofEngineer- in -Charge Complete. |
| 18 | Providing Material & Labour for Rebaring in Existing Column, Beam and Slab including all dia. Of bars 12mm to 25mm as per drawing and specification depth as directions ofEngineer in charge Complete. Make Hilti or Fischer or its equivalent as approved by Engineer-in-Charge Complete. |
| 19 | Brick work using common burnt clay building bricks including scaffolding, raking of joints, curing using first class bricks having min. comp. Strength 35 kg/cm2 of approved manufacturer in foundation and plinth in Cement Mortar 1:6 (1- Cement : 6 -fine sand)(B)ConventionalAll bricks and shallbe soaked in waterfor at least 24 hours before use.bricks used for masonry work shall be as available locally, but approvedbefore start of work. volume of masonry to be measured for payment. |
| 20 | Providing & fixing LIGHT WEIGHT MASONRY BLOCKS of- Sand Based Autoclaved Aerated Concrete blocks (AAC Blocks) Using Epoxy based jointing adhesiveof approved make, upto all floor level/all heights, masonry walls in jointing mortar, complete as per Technical specification, density of blocks shall not exceed 700 kg/cum, using bonding material supplied by the manufacturer as per their instructions, including necessary scaffolding for fixing, in line & level. Volumne of blocks erected to be measured for payment. R.C.C. coping of size-wall thickness x 100mmht. at 0.91m intervals shall be provided including reinforced with 2 Numbers 6mm diameter horizontalbars and8mm diameterat 200 c/cties. R.C work not to be measured separately but included in rate.other specifications as directions of Engineer in Charge Complete |
| 21 | Providing & fixing 150mm or less thick LIGHT WEIGHT MASONRY BLOCKS Using Epoxy based jointing adhesiveof- Sand Based Autoclaved Aerated Concrete blocks (AAC Blocks) of approved make, upto all floor level/all heights, masonry walls in jointing mortar, complete as per Technical specification, density of blocks shall not exceed 700 kg/cum, using bonding material supplied by the manufacturer as per their instructions, including necessary scaffolding for fixing, in line & level. Area of blocks erected to be measured for payment. For wall thickness up to 150mm, R.C.C. coping of size-wall thickness x 100mmht. at 0.91m intervals shall be provided including reinforced with 2 Numbers 6mm diameter horizontalbars and8mm diameterat 200 c/cties. R.C work not to be measured separately but included in rate.Using Epoxy based jointing adhesive & other specifications as directions of Engineer in Charge Complete |
| 22 | Providing and laying 10mm thick in single coat CEMENT PLASTER in (i)Cement mortar 1:3 (1-cement:3-sand) at all height/all floors to internal surfaces of all elements, walls, R.C.C. work, Ceiling,[backing coat at places where glazed or ceramic tiles are to be fixed etc]. including hacking of concrete surfaces, racking of joints, scaffolding, curing etc. complete. Final finished surface shall be little rough , so as it has proper bonding to paint putty.The surfaces to be plastered to be hacked immediately on de-shuttering. The Brick/ RCC surface to be plastered to be cured sufficiently before start of plaster. Initial bare surface area to be Plastered shall be measured for payment unless noted otherwise, etc as directions of Engineer in charge Complete. |
| 23 | Providing and laying 20mm thick malaCEMENT PLASTER of required grain finishing upto all height/all floors includinggrooves,pattas etc. in two coats having the the base coat of not less than 12 mm thickness in CM 1:3 (1-cement : 3-sand) & finished coat 8 mm thk, in CM 1:1 (1-cement : 1-sand) to external surfaces of concrete & masonry including hacking of concrete surfaces, racking of joints, scaffolding, curing etc. complete. Rate shall include addition of “Impermo” water proofing compound or equivalent, providing, adding & mixingoffine fibrillated 100% virgin polypropylene fibers in cement mortar to formhomogeneous mixture @125 gms per a bag of cement in both the coats of plaster, 12mm long fibers shall be used in first coat & 6mm long fibers shall be used in second finished coat. providing drip mould 40mm wide and 12mm thick in cement mortar 1:3 on soffit of chajjas, canopies, gutters. The surfaces to be plastered to be hacked immediately on de-shuttering. The Brick/ RCC surface to be plastered to be cured sufficiently before start of plaster. Initial bare surface area to be Plastered shall be measured for payment unless noted otherwise, etc as directions of Engineer in charge Complete. |
| 24 | Providing material and labor for applying Two coats of gypsum 2 to 3mm thk. including providing grooves at all the edges of windows/Doors with neat finish on new/existing wall surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth.make the surface uniform and levelled and must be without any undulation asdirected by engineer in charge complete.Make: Diamond gypsum or as approved by engineer-in-charge. |
| 25 | Providing material & labour for Internal Wall painting (two coats) with Premium Emulsion of approved brand and manufacture including primer coat on undecorated wall surface to give an even shade including throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth. asdirected by engineer in charge complete. emulsion that must offer protection against different varieties of bacteria and fungus.The product shall be independently tested and approved for properties like resistance to bacterial and fungal species, crack tolerance and flame spread resistance.The coating shall contribute to satisfying the following credit(s): Indoor Environmental Quality (IEQ) under LEED® 2009 Environmental Quality (EQ) and Materials and Resources (MR) under LEED® v4This product shall have a VOC limit not more than 24 g/lit.The product can be like Asian apcolite emulsion or Jotun Paints or approved equivalents.Two Coats of above paint should be applied using conventional Roller / Airless spray at the site after application and drying of applied Putty-Primer. Formeasurement of painting items the area painted shall be considered without any multiplication factor for different kinds of surfaces painted. Rate shall be quoted accordingly. All painting items final finish shall be as per manufacturer\"sspecification as per acceptance of Engineerin charge /Architect. No extra payment shall be made for extra/over coat if required.The rate shall be inclusive of providing bamboo scaffoldingMake: Jotun,Asian Paints, Berger Paints, Dulux Paints or as approved by chief engineer. |
| 26 | Providing material and labour for anti-mould medium grain Textured finish plaster with high erosion resistance, aging resistance, good elasticity made of required shade on external wall surface including thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials.etc complete inluding required scaffolding with providing putty,applying exterior wall primer with brush.Firstdamp proof base coat of paint to be applied with air assisted spray gun. Then spray two finish top coat of ultima allura series or as selected by EIC with brush/ spray/ roller all complete as per EIC. Sample to be approved by the architect. (make: Asian paint- Ultima Allura Meraki) as approved by engineer-in-charge. |
| 27 | ALUMINIUM WORKS-Doors and Windows workProviding material and labour for fixing in position frames, shutter for any type of aluminium work for any type of door, window, partition, made out of any type of aluminium sections of approved make having minimum 50 micron pure polyester powder coating of approved shade, texture & colour of approved make for all floors, all levels, all heights, all shapes, all sizes including cutting, bending, crimping, fabricating in best workmanship manner etc as per the drawing, specification and as directed by Architect or Engineer-in-Charge. Contractor shall prepare shop drawing based on concept drawing and get approved from the consultants before procurement of material. All loose material shall be approved. Mockup of one/two window shall be executed as per approved shop drawing with all hardware. Work shall carried out as per the approved shop drawings, approved mock-up and approved sample. Actual weight of installed Aluminium sections (for using fabrication without considering any wastage) shall only be measured and shall be considered for the payment. Glazing shall be paid as seperate item. Contractor shall provide guarantee for stability, water tightness etc for 12 months after defects liability period. Rate shall be inclusive of providing aluminium sections, cutting, fabrication, errection and fixing to the best workmanship manner, including1) Sheet metal screws and casted solid aluminum corner cleats fixed with external byttins with a spring for rapid and secure joint assembly for casement and sliding shutter and frame;2) Glazing clips for receiving infill panel; 3) Best quality wool pile where ever shutter touches the frame and compatible microwave cured EPDM rubber; 4) Dash Anchor fasteners of HILTI HRDUGT or equivalent for fixing the frame assembly to the RCC or masonry surfaces. Minimum 1 anchor fastener shall be used for every 600 mm length of section for stability of frame. 5) 10mm GI tie rod for connecting vertical stile at top and bottom for aluminum door shutter and 4mm thick solid aluminium corner cleat of full thickness of sectionfor connecting style and horizontal rails; 6) providing and fixing packing (rough ground) in full periphery/ at every 600mm c/c with average 6 mm thick PVC spacer/ compact sheet of width (equal to section width less 30mm for backer rod and sealant); 7) Filling the gap between wall and frame on both sides (outside and inside) with polyethylene baker rod of avg. 10 mm thickness of approved make and color and then sealing the remaining gap with neutral grade G/M (Glazed & Metal) weather silicon sealant of approved make and color. 8) Termite treated seasoned teak wood as infill material to installe hardware in door shutter and frame as and when required, etc as per directions of Engineer in charge Complete. Make:- Jindal or equivalent as approved by Engineer-in-charge |
| 28 | Providing & Fixing Louvers and Fins (made out of Aluminium Section)Providing, fixing, designing aluminium fixed louver of any type of louver section of approved make having minimum 50 micron polyster powder coating on all the surfaces of approved shade, texture & make as per manufacturer\"s specifications. Contractor shall submit the shop drawing for louver/ fins based on concept design/ drawing and as per elevation. Aluminium louver section shall be fixed on aluminium framing/ carrier/ panel/ GI clip and necessary sub structure with required fastners, hardware as per approved shop drawing etc complete for all floor, all height including scaffolding as directed by engineer in charge.Louver, framing and sub structure shall be in proper line, level and plumb. Necessary MS work shall be paid in relevant tender item. |
| 29 | Design, Fabrication, Supply, All Main Material, Protection, Handover of Curtain wall system custom designed for building elevation to with stand the design wind pressure confirming to IS -875 part III. microwave cured EPDM gaskets, weather sealants, backer rod, SS 304 grade fasteners & Anchor Fasteners, nylon separators to prevent bi-metallic contacts, curtain wall and the building structure all complete required to perform as per specification and drawing. The system shall be designed of floor height units spanning between the floors with Dead load & wind load brackets with provision to accommodate movement at all floor levels and at every grid panels horizontally. The system shall be designed to accommodate 24 mm DGU in vision area. System shall accommodate openable panel as per architectural requirement in the system. All fix vision glass and openable shall look similar in the elevation. Each glass panel shall be structurally glazed on the main semi unitised profile system. Each glass panel shall be supported for dead load at the bottom of glass with black anodised glass retainers two per panel. The three-barrier gasket system consists of 2nd & 3rd barrier of EPDM gaskets to achieve the required compression & seal in the system. EPDM Gaskets shall be of micro cured (Online Curing) with shore A hardness of 60-65. Flashing / Trim / Floor Closure at Parapet level, floor level, beam bottom level and required flashings shall be provided continuously with required GI / Aluminium sheet. Internal & External concealed Flashings shall be 1.0mm thk GI sheet. External exposed flashing shall be 1.5mm thk. Aluminium sheet with SDF coated matching with external Aluminium profiles. Internal exposed flashing shall be 1.5mm thk. Aluminium sheet with powder coated matching with internal aluminium profiles. The structural profiles shall have minimum 2.5mm wall thickness. All the internal visible surfaces shall have high Durability (AkzoNobel) / Super durable (Jotun) Powder coating of 60 - 80 micron confirming to AAMA 2604 & non visible aluminium surfaces shall have minimum chromicizing treatment. All shade approval shall be as per Architect\"s Approval. The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all Taxes, duties, statutory obligations and safety code compliance as per Client. Brand – ALUKA Profile - 56.3 x 63 x 2.5mmProfile Shutter - 50 x 50 x 2.5mm -as per detailed design and drawing or as directed by engineer in charge. |
| 30 | Providing material and labour for fixing 6mm thick Compact Sheet of any size, any shape, any color (single side, double side coloured), any texture of approved make and as per approved sample(approved by architect). Compact sheet shall be fixed in aluminium frame and shutter work with necessary cutting of sheet, provision of groove, filling of groove (both side) as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ adhesive tape/ screwing on the periphery of the sheet as per the required thickness etc. complete at all floors/ all levels/ all heights as per the drawing & directed by Engineer in charge. Cut edges of the compact sheet shall be provided with masking tape. Actual installed quantity shall be measured and paid. |
| 31 | Providing material and labour for fixing factory made and pressed laminated 35mm thick flush door shutter of specificied thickness made of ISI marked non decorative type flush door shutters confirming to IS- 2202 (Part 1), core of plywood& to be fixed with aluminium frame/wooden frame. faceveneers(IS 710 Grade) onbothfacesof shutters having 1 mm thick decorative type laminates of approved make, shade, finishonbothfacesofshutterfixedwithphenol formaldehyde synthetic resin type adhesive conforming to IS 848 including providing and fixing external lipping with 2nd class teak wood battens, exposed (37mm x 12mm)/ concealed (35mm x 12mm) on all edges of door shutter as requiredwith 2 coats of synthetic enamel painting including 1 coat of wood primer & lapi/ lacquer polishing with primer to all exposed side of lipping, all as per approved drawing, for all floor, all level all height etc. complete as directed by Engineer-in-charge. Measurement including lipping shall be considered for payment. Necessary hardware like hinges, pivot, handle, tower bolts, locks etc shall be separately measured and paid in the relevant tender items. Cost of laminates shall be paid in relevant tender item. |
| 32 | Providing and fixing 30mm thick factory made wire guazed solid PVC Door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles and 15mm x 15mm for top, lock and bottm rails, M.S. frame shall have a coat of steel primers of approved make and manufacture, 19mm x 19mm M.S. square tubes shall be coveed with 5mm thick head moulded PVC ‘C’ channel of size 30mm thickness, 90mm width out of which 75mm shall be flat and 15 mm shall be bent in 90 degree angle on either side forming stiles and 5mm thick 115mm wide PVC sheet out of which 100mm shal be flat and 15mm shal be bent in 90 degree on the inner side to from top and bottom rails and 130mm wide PVC sheet out of which 100mm shal be flat and 15mm shal be bent in 90 degree on both side to from lock rail10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail and bottom rail, panel will be of G.I. wire gauge of 24 gauge to be fitted in by ‘C’ channel of size 10mm x 35mm on the either side in the stiles.The inner side ‘C’ channel is fixed by 19mm x 19mm M.S. tube on both side with screws. The wire mesh in top, bottom and lock rail is sealed with 15mm x 15mm tube with G.I.wire, 1mm (5mmm x 2) thick PVC strip of 25mm width is to be stuck and screw on both side of G.I. wire guage interior at the top, bottom and lock rails. An additional 5mm thck PVC strip of 20mm width is to be stuck on the interior side of the‘C’ channel using PVC solvent cement adhesive etc. complete as per dirction of Engineer in charge, manufacture’s specificationand drawing. |
| 33 | Providing material and labour for fixing 1 mm thick Laminate sheet of any size, any shape, any color, any texture of approved make and as per approved sample(approved by architect) on Non decorative flush door, panelling work, fixed partition, any ply surface etc with necessary nails, screws, adhesives as per drawings and as per approved sample. The rate shall be for all heights, all floors, all places etc complete as directed by engineer in charge.Actual laid area shall be measured and paid without considering any westage. Laminates and ply shall be factory pressed. |
| 34 | Providing material and labour for fixing 6mm thick Clear Normal Glass as per approved sample of any size, any shape and specified thickness in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ structural sealant and 3M tape on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Engineer in charge. Actual installed quantity shall be measured and paid. |
| 35 | Providing material and labour for fixing 6mm thick Clear Toughen Glass as per approved sample of any size, any shape and specified thickness in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ structural sealant and 3M tape on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Engineer in charge. Actual installed quantity shall be measured and paid. |
| 36 | Notes for Hardware : Supplying and fixing heavy quality fixtures and fittings for doors, windows, ventilators, partition wall, cabinets with necessaryscrews, nails, machine pins etc at all floor/ all levels/ all heights complete. Sample shall be approved by Architect before execution. As per description, SS hardware shall be of 304 grade or 316 grade as per item description and as per approved sample. The fixture & fastenings shall be provided as under :Providing material and labour for fixing single/ double action hydraulic floor spring with SS cover plate & adjustable concealed casted top pivot (two piece) and bottom strap of approved make for wooden/ aluminium doors of specifiedcapacitywith minimum one year guarantee. Rate shall be inclusive of cutting of floor neatly, grouting the floor spring & cleaning/ polishing the floor & maintaining in good working condition until defect liability period. In case of Aluminium shutter bottom arm of floor spring & top pivot shall be firmly fixed in the aluminium members using required size of teak wood by making rabbet in the wood. The Floor Spring shall conform to EN 1154. a) Hold open having for shutter width upto 1200mm with standard spindle and cover plate. Closing force complying with EN 1154 2-4 |
| 37 | Providing & Fixing heavy qualitySS 304 heavy pivot top & bottom (pair) of approved make with SS screwsect complete as directed by engineer in charge. Make Dormakaba or as approved by Engineer in Charge |
| 38 | Providing material and labour for fixing hydraulic rack and pinion door closer with standard arm (Silver finish) with screws to pivoted/ hinged door of approved make for specified door width with minimum one year guarantee. All adjustment screws face fixed. Rate shall be inclusive of fixing with using the template as per manufacturer’s specification & maintain in good working condition until defect liability period. The door closer shall conform to EN 1154 standard.a) with standard/ hold open arm with two independent closing valves and latching speed adjustable by arm without mounting back plate, Closing force complying with EN 1154 2 - 4 for up to 700 mm door shutter width Make Dormakaba or as approved by Engineer in Charge. |
| 39 | Providing material and labour for fixing SS 316 grade butt hinge of average 100 x 75 x 3 mm - with ball bearing of approved make as per approved sample with necessary screws etc. complete for all floor all height all level as directed by Engineer in Charge.Make Dormakaba or as approved by Engineer in Charge. |
| 40 | Providing material and labour for fixing set of dead lock of approved make with 50mm backseat, 20mm square for end with 72 mm centers including strike plate in satin stainless steel finish as per DIN 18251-1, grade 2 and prepared for euro profile cylinder (EPC) including strike plate and EPC length 60/70 mm standard Euro profile Pin Cylinder/ Half pin cylinder with both side key/ one side key one side knob operation with one pair of SS 316 grade Escutcheons (key hole plate) for wooden/ aluminium/ metal doors with necessary SS Phillips head screws etc complete for all floor, all level, all height as per approved sample and as directed by engineer in charge. The lock shall be with 3 keys.Make Dormakaba or as approved by Engineer in Charge. |
| 41 | Providing material and labour for fixing SS 304 satin finished set of narrow style dead lock of approved make with 25mm /35 mm set back necessary euro profile pin cylindrical lock 60/ 70 mm for Key and or knob operation and one pair of SS 316 grade Escutcheons (key hole plate) for aluminium door with necessary SS Phillips head screws etc complete for all floor, all level, all height as per approved sample and as directed by engineer in charge. The lock shall be with 3 keys.Make Dormakaba or as approved by Engineer in Charge. |
| 42 | Providing material and labour for fixingMortise lock of approved make having 72mm centre to centre, 55mm Backset 20mm Square forend and 60/ 70mm standard Europrofile Pin Cylinder with both side key /one side key - one side knob operation and SS 316 grade hollow tubular pipe pair of Mortise handle of 22mm dia 150mm long with a pair of SS 304 Escutcheons (key hole plate) for wooden /aluminium/ metal doors with necessary ss phillips head screws etc complete for all floor, all height, all level as per approved sample as directed by engineern in charge. The lock shall be with 3 keys.Make Dormakaba or as approved by Engineer in Charge. |
| 43 | Providing material and labour for fixing Mortise shaft dead bolt of approvedmake with key (Alen Key lock), sleeve with 57mm backset and 25mm square forend in stainless steel satin finish etc complete for all floor, all height, all level as per approved sample and as directed by engineerin charge. |
| 44 | Providing material and labour for fixing Zinc material indicator bolt of approved make for toilet door with Thumb Turn inside & Emergency Release & Indicator Outside with necessary screws etc complete for all floor, all height, Make Dormakaba or as approved by Engineer in Charge. |
| 45 | Providing material and labour for fixing SS 316 grade push-pull pair of handle of size 200 mm long x 19mm dia made out of satin (brush) finish hollow pipe of 1.5mm thick having offset type (C or D shape)/ H-shape/ D-shape of approved makewith necessary screws etc. complete forwooden doors/ aluminium doors/ metal doors for all heights, all floors and all level as per approved sample and as directed by Engineer-in-charge. Rate shall be The length of handle should be perfect center to center as below specified.Make Dormakaba or as approved by Engineer in Charge. |
| 46 | Providing material and labour for fixing SS 316 grade handles 150mm long D shape hollow tube handle of approved make with both end bracket with necessary screws etc. complete for all floor, all height, all level as per Make Dormakaba or as approved by Engineer in Charge. |
| 47 | Providing material and labour for fixing of SS 304 grade brush finish 450mm height Tower bolt (barrel type with minimum rod size shall be 10mm) of approved make in wooden doors/ aluminium doors/ metal doors with necessary screws etc. complete for all floor, all height, all level as per Make Dormakaba or as approved by Engineer in Charge.. |
| 48 | Providing material and labour for fixing of SS 304 grade satin finish lever action Flush tower bolt with 19mm projecting bolt (extended rod of 600mm length) aluminum casted of approved make for double shutters aluminum door, with necessary screws etc. complete for all floor, all height, all level as per Make Dormakaba or as approved by Engineer in Charge. |
| 49 | Providing and Fixing SS 304 Grade Satin Finish 1.8 mm Thickness Aldrops of 16 mm dia x 250 mm including 3 nos. fixing Bracket and 1 no. locking bracket of approved make with necessary MS nickle Plating Boltsetc. complete for all floor, all height, Make Dormakaba or as approved by Engineer in Charge. |
| 50 | Providing and Fixing SS 304 Grade Satin Finish 1.8 mm Thickness Tadi of 12mm dia x 200mm including 3 nos.fixing Bracket of approved make with necessary screws, pins, bolts etc. complete for all floor, all height, Make Dormakaba or as approved by Engineer in Charge.. |
| 51 | Providing material and labour for fixing SS 304 brush finish solid Door Stopper with magnet, fixed type, wall mounted (square/ round) of approved make with necessary screws etc. complete for all floor, all height,Make Dormakaba or as approved by Engineer in Charge. |
| 52 | Providing material and labour for fixing SS 304 grade brush finish solid Door bufer with pvc base, wall mounted (square/ round) of approved make with necessary screws etc.Make Dormakaba or as approved by Engineer in Charge. |
| 53 | Providing material & labor for laying 48\" x 72\" Vitrified 10 mm thick tile flooring over 20 mm (average) base of cement mortar 1:4 ( 1 cement: 4 coarse sand) on new surface or fixing on existing flooring by adhesive material including cost of dismantling of existing flooring and spacer of required size to be provide while fixing the tile. Tiles joint grooves to be filled with 8mm wide epoxy of approved shade/colour including finished with flush pointing & cleaning the surface etc. complete.Make: Nitco, Simpolo, Kajaria, johnson, Rak or as approved byengineer-in-charge complete. |
| 54 | Providing material & labour for laying Vitrified tiles 10 mm thick , in required size for Skirting upto 100mm on 10mm thick cement plaster 1:3 (1-cement : 3-coarse sand) and jointed with white cement slurry including finised with flush pointing & cleaning the surface etc. complete. For SkirtingMake: Nitco, Simpolo, Kajaria,johnson, Rak oras approved byengineer-in-charge complete. |
| 55 | Providing and layingGranite stone flooring inrequired design and patterns, in linear as well as curvilinearportions of the building all complete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge. Make:- Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 56 | Providing material & labour for Fixing 15 mm thickFull body heavy duty vetrified tiles, premoulded and prepolished machine cut forplatforms, vanity counters, door window, sills, jambs, soffits facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding on all exposed edges and polishing to edge to give high gloss finish etc. complete. at all levels. Make: Somany Duragres granit series or equivalent as approved by engineeri-in-charge or Architect |
| 57 | Providing material and labour for fixing 25mm to 30mm thick kadappa stone on parapet wall with cement motar 1:4 (1 Cement : 4 fine sand) and neat cement slurry as per requirement including cutting the kadappa stone etc. as directed by Enginner on Charge. |
| 58 | Providing and fixing Decorative WPC deck flooring for swimming pool area with make of first quality at with required support in wood or MS as per the design.The workmanship shall be to the satisfaction of the Architect. as directed by Enginner on Charge.Complete. |
| 59 | Providing material & labour for Fixing GYM Rubber Interlocking Tile 20-25 mm& density of the rubber is 900 to 950kg/m3 of approved patter and design as directed by Engineer on Charge etc complete |
| 60 | Providing material & labour for Fixing Carpet tile technical specification for chess roomMaterialPile Fiber: Nylon 6 or Nylon 6.6Dye Method: Solution dyedBacking Material: PVC / Bitumen / Polyurethane cushion back.Tile Size:60 cm x 60 cm.Backing Type: Eco-friendly backingPile Weight: 500 – 800 g/m² Thickness: 6 – 9 mmDensity: High density for improved durabilityAntistatic: ≤ 2.0 kV,Dimensional Stability: ≤ 0.2% (ISO 2551)Impact Sound Reduction: ≥ 25 dB and design as directed by Engineer on Charge etc complete |
| 61 | Providing and laying Waterproofing for a swimming pool Technical Specification:- Surface Preparation:-Cleaning: Ensure the surface (concrete, plaster, or tile) is clean and free from any dirt, debris, or loose particles. Use pressure washing or sandblasting to create a rough surface for better bonding.Repairs:- Repair any cracks, holes, or surface imperfections using repair mortars or fillers. The surface must be smooth and uniform before applying waterproofing.Waterproofing Materials:- Liquid Applied Membranes: polyurethane based liquid coatings, applied in several coats having 2mm thickness and cure to form a seamless membrane.Crystalline Waterproofing (as additive or surface treatment)Material: Crystalline slurryFor Liquid Membrane:Primer: As recommended by the manufacturer, Membrane: Apply in 2 coats using a roller/spray/trowel, Protection Layer: 40mm screed for mechanical protection, Application: Brush-applied or dry-shake on green concrete or added to concrete mix.Application Process:Primer Layer:- For bonding purposes, a primer coat is applied to the prepared substrate Waterproofing Application:-Apply the first coat of the waterproofing membrane evenly using brushes, rollers, or spray equipment (depending on the product).-Allow the first coat to cure completely, usually between 24 to 48 hours.-Apply subsequent coats, ensuring each layer is applied at the manufacturer’s recommended thickness.-Pay special attention to corners, edges, and joints where waterproofing is critical.Sealing Joints and Edges:Expansion Joints:- Use a high-quality sealant like polyurethane to seal all expansion joints to prevent water seepage.Perimeter Edges: Ensure that all perimeter edges, including around the pool’s tile line and other water features, are thoroughly sealed.Tile and Grout:Tile Installation: Installation China Mosaic tile 8 to 10mm thk.blue colour Once the waterproofing membrane has cured, tiles can be installed with a flexible adhesive that accommodates movement.Grouting: Use waterproof grout to fill in the joints between the tiles, ensuring no water can seep through the tile lines.Curing and Testing:Curing Time:- Allow all waterproofing and adhesive materials to cure as per the manufacturer\"s specifications (typically 24-72 hours). Water Tightness Test: Perform a water-tightness test to check for leaks, often done by filling the pool with water and monitoring for any drop in water levels over a specified period & with with a guarantee of 10 years on bond paper. etc. complete as directed by Engineer in charge. |
| 62 | Providing material, Labour and equipments for Providing and laying integral Cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations : a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer in charge over the RCC Slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks / brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in charge over 20mm thick layer of cement mortar of mix 1:5 ( 1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junction of walls and slabs. c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg / sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in charge.d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 ( 1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300 x 300 mm square 3 mm deep.e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.All above operations to be done in order and as directedand specified by the Engineer in charge : Including Khurra & Gola work with average thickness of 120mm and minimum thickness at Khurra as 65 mm etc. complete as directed by Engineer in charge. |
| 63 | Providing and Laying broken China mosaic flooring for terrace using 12 to 20mm broken pieces of only white glazed tiles ( Bell/Somany/johnson/kajaria/cera/Spaetek / Orient/Nitco) to be laid over cement mortar 1:3 to plain or Slope and to be tempered to bring Mortar cream out up to Surface using white cement including off Junctions and extending them up to wall top.Curing with Water and cleaning with Oxalic acid etc. as Directed byEngineer in charge. |
| 64 | Providing Material & Labour DIVING BOARD for swimmingtechnical specification for a diving board:Dimensions:Length:3 meters (10 feet) or 5 meters (16.5 feet) Width:50 cm (19.7 inches) Thickness: 5–10 cm (2–4 inches)Material:-High-density, non-slip materialfiberglass Core Material:plywood, fiberglass, or synthetic composites.Frame:-Strong, rust-resistant material like stainless steel or aluminum.Spring Mechanism:Springs:stainless steel springs for flexibility and bounce.Spring Cover:spring mechanismcovered with a protective casing made from rubber or another impact-resistant material to prevent injury. Load Capacity:100–250 kg (220–550 lbs) as directed by engineer-in-charge complete. |
| 65 | Providing material, Labour JUMPING BOARD Diving Springboard Technical Specification:-Dimensions:Length:-Standard: 4 meters, Width:50 cm, Height from Pool Deck:1 meter (3.3 feet) to 5 meters (16.4 feet)Material:Board Surface:The surface is usually made of fiberglass or composite materials with a non-slip coating. Spring Mechanism:-The springboard is supported by a set of heavy-duty springs (either metal coil springs or leaf springs) that provide varying levels of flexibility.-The springs are housed inside a sturdy steel base, ensuring proper tension.Spring Action:Flexibility:-The flexibility of the springboard is crucial for diving. The board should have the ability to bend and release energy for jump height and controlled movements.Load Capacity:- 50 to 130 kg (110 to 290 lbs)Mounting and Adjustment:Mounting:The diving board is mounted on a pedestal or stand, usually fixed to the edge of the pool, which should be stable and able to handle vibrations.Adjustable Settings:-Higher-end models allow adjustment of the spring tension or height of the board to suit individual preferences.as for directed Engineer-in-Charge Complete |
| 66 | Providing material, Labour for fixing Swimming Pole Handle technical specification:- Main Body:Material:stainless steel (preferably AISI 304 or AISI 316 for saltwater pools).- Alternative: High-quality plasticwith UV protection. - Finish: stainless steel finish, powder-coatedDesign & DimensionsShape:- curved Height from Pool Deck: 30 - 36 inches (76 cm to 91 cm) from the pool deck to the top of the handle. Length:24 - 36 inches (61 cm to 91 cm)length of the handleDiameter of Handle: 1.5 - 2 inches (4 - 5 cm).Load Capacity:-150 kg (330 lbs),as for directed Engineer-in-Charge Complete. |
| 67 | Providing & Fixing Material & Labour SUN BED for swimming area-technical specification:- Materials:-stainless steel Finish:- UV-resistant powder coat Design:- LightweightSeating Surface:Material: High-density polyethylene (HDPE) slats, UV-resistant textile mesh, or quick-dry foam.Cushions: Outdoor-grade foam with water drainage properties, covered in UV-resistant fabric (e.g., Sunbrella, Textiline).Cover: Waterproof and breathable material to prevent moisture buildup and promote air circulation. Legs:-Material: Non-slip rubber or plastic tips for stability and safety.Dimensions:-Length:-190 cm (75 inches) to 210 cm (83 inches).Width: 60 cm (24 inches) to 80 cm (31 inches).Height:35 cm (14 inches) to 45 cm (18 inches). |
| 68 | Providing Material & Labour swimming pool FRP drain covera general outline of the key specifications for a FRP drain cover:- Material- Fiberglass Reinforced Polymer (FRP).Design and Dimensions:-Diameter/Size:12 inches (3000mm) to 24 inches (600mm),Shape:rectangular.Drain Slots/Opening: Slots or perforations for water drainage,Load Rating:Maximum Load: The cover should be designed to withstand typical loads (e.g., pedestrians walking over it) with specified load-bearing capacity, typically ranging from Class A (light load) to Class D (heavy load) as per EN 124 or ASME B15 standardsas approved by architct and engineer in charge complete |
| 69 | Providing material and labour for fixing suspended FALSE CEILING -made out of 12.0 mm (apprx.) thick Gypsum Plaster Boards of gyproc or equivalent made G.I standard section framework. -The G.I. Section frame work shall be tied to the roof and walls with the anchor fastener screws/bolts of appropriate size recommended by the manufacturer . -The boards shall be fixed to the frame work with the screws and the joints shall be flushed and finished with requisite jointing compounds paper tapes etc.-the ceiling will have 300mm wide plywood band will finish in1mm thick laminate having Burma teak texture as shown in drawing.-The surface shall be finished evenly by applying putty, sand papering, applying primer & paint of approve make and type evenly complete with designer ceiling with part ply + laminate as shown in drawing -making all necessary provision and cut outs for all electrical boards, wiring, HVAC , plumbing etc. fittings, fixtures and cleanliness as per detailed design and drawing or as directed by engineer in charge. -height of false celling will be approx. 3000mm from Floor finish level,-Price shall include any ledge, grove, offset, edging in sq.mt. only. -Length X breath of false ceiling will measured for payment. as directed by Engineer-In-Charge etc. complete. (RA) |
| 70 | Providing and fixing in true horizontal level FALSE CEILING with metal sheet 2mm in-grid system manufactured by M/s. Armstrong World Industries (India) Pvt. Ltd or its equivalent -using hot dipped galvanized steel section, exposed surface chemically cleaned capping prefinished in backed polyester paint wall angle used in periphery of the ceiling fixed to the wall/partition/RCC column/band walls with the heip of screws-Main runner of size appropriate size suspended at specfied distaance c/c by using G.I. wire or any other hanger securely fixed to the structural member by using anchor fastener. long cross tee to be interlocked between in main runner to form grid as per architectural design. -and finally fixing metal ceiling of size as per drawing or as approved by engineer-in-charge-height of false celing shall be as per architectural drawing from Floor finish level -The rates to include cutouts for lighting fixtures / AC grilles / Fire Alarm Detectors etc., along with necessary strengthening and supports for fixing of these. |
| 71 | Providing material and labour for fixing suspended GRID FALSE CEILING 600x600mm-made out of 12.0 mm (apprx.) thick Calcium silicate Boards of gyproc or equivalent made G.I standard section framework. -The G.I. Section frame work shall be tied to the roof and walls with the anchor fastener screws/bolts of appropriate size recommended by the manufacturer . -The boards shall be fixed to the frame work with the screws and the joints shall be flushed and finished with requisite jointing compounds paper tapes etc.-the ceiling will have 300mm wide plywood band will finish in1mm thick laminate having Burma teak texture as shown in drawing.-The surface shall be finished evenly by applying putty, sand papering, applying primer & paint of approve make and type evenly complete with designer ceiling with part ply + laminate as shown in drawing -making all necessary provision and cut outs for all electrical boards, wiring, HVAC , plumbing etc. fittings, fixtures and cleanliness as per detailed design and drawing or as directed by engineer in charge. -height of false celling will be approx. 3000mm from Floor finish level,-Price shall include any ledge, grove, offset, edging in sq.mt. only. -Length X breath of false ceiling will measured for payment. as directed by Engineer-In-Charge etc. complete. (RA) |
| 72 | Providing and fixing UPVC fins for cladding or as part of building façade systems in approved colur & specifications for UPVC fins with dimensions of 50mm x 50mm:1 Material - Type: Unplasticized Polyvinyl Chloride (UPVC) - Density: Typically ranges between 1.3–1.45 g/cm³ - UV Stability: Must be UV stabilized for outdoor use to prevent degradation under sunlight2. Dimensions - Width: 50mm - Height: 50mm - Thickness: 3mm - SPACING : 50mm between two fins - Length: As per architectural details 3. Physical Properties - Tensile Strength: Generally around 40–55 MPa - Impact Resistance: High impact resistance - Flexural Strength: 60–80 MPa4. Installation with the necessary framing work shall be part of scope of work. - Fixing:on ms framing with appropriate UPVC-compatible fixings such as screws, bolts, etc. 6Kg/Sqm MS framing shall be considered for quoting. All other techincal details as directed by engineer-in-charge |
| 73 | Demolition including stacking of serviceable materials including cuttinganddisposal of unserviceable materials with transporting the reinforcement within 10 km and finishing the broken surfaces to match with the surroundings including the disposal of unserviceable materials with all lead and lift. (i) R.C.C. work, Foundation, Road works (Reinforcement/ steelwork to be submitted to the engineer in charge/authority. |
| 74 | Demolition of Brick work and stone masonry including stacking of serviceable materilas and disposal of unserviceable materials with 10km lead and lift.(ii) In Cement Mortar. |
| 75 | Removing and scraping of old deteriorated plaster of any thickness fromm wall / R.C.C member including stacking of serviceable material and disposal of unserviceable from site of work with 10km lead and lift |
| 76 | REMOVING,aluminum partition framewith 6mm thk. glass for partition wall with all necassry fittingetc. including all materials , labours, and equipment etc. with 10km lead and lift Complete. |
| 77 | Dismantling of sheet roofing including ridges, Hips, Valley, gutters, etc. Stacking of serviceable material and disposal of unserviceable material with 10km lead and lift (i) GI sheet roofing |
| 78 | Dismentling steel work including distempering and stacking the materials with 10km lead and lift. |
| 79 | Dismentling doors, windows, ventilators etc. (wood or steel) Rolling shutters including chowkhats architraves, holdfasts and other attachment etc. complete and stacking them with 10km lead and lift.(ii) Exceeding 3 Sq.M. in area. |
| 80 | REMOVING OF PAVER BLOCK of tiles or any other type of flooring including the screed below and carting away the debris as directed.with 10km lead and lift |
| 81 | Dismentaling/Removal of any type of Cladding/Fasad Tiles laid in mortar/ms structure/etcincluding stacking of serviceable materilas and disposal of unserviceable materials with 10km lead and lift. |
| 82 | REMOVING OF FALSE CEILLING of tiles or any other type of flooring including the screed below and carting away the debris as directed.with 10km lead and lift |
| 83 | Dismentalingtiled or stone floors laid in mortar including stacking of serviceable materilas and disposal of unserviceable materials with 10km lead and liftt. |
| 84 | REMOVING OF Carpet tiled floors laid in mortar including stacking of serviceable materilas and disposal of unserviceable materials with 10km lead and liftt. |
| 85 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches removing the roots and stacking of serviceable material after cutting in approved sizes and disposal of unserviceable material with 20km lead and lift. (a) Beyond 30 cm girth upto and including 60 cm girth |
| 86 | Providing material & labour for fixing Sand blasted pre-cast concrete High Strength High Finish (HSF) paver block 80mm thick as per design of any shape/any size with percentage of water absorption not more than 6%, compresive strength not less than 350 kg/Sqm. Tensile splitting strength (as per EN 1338) not less than 3.6 Mpa any colours as per approved designincluding75mm Sand bedding layer for levelling and filling the joint with sand in proper line and level.The paver block should be strong enough to take heavy traffic load. The sand bed should make up for all the undulations and give a leveled surface. A mechanical compactor shall be used for compacting the sand base. All this should be in line with the manufacturer\"s specifications and the Engineer\"s directions. The final surface should be swept clean of all dust and sand to get uniform and smooth riding surface. Area of Block laid to be measured for payment etc complete. Make:- Vyara and Supertiles or equivalent. |
| 87 | Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block 60cm length,30 cm height and 15cm thick of M250 grade concret as per approved design and includingexcavation for fixing in proper line and level,filling the joint withC:M 1:3 (1cement:3fine sand) etc complete. |
| 88 | Providing material and labor for GARDEN SOIL:- Supplying on site garden soil well sieved 90% to pass through I.S. sieve of 10mm size free from stones rubbish like dried grass roots and other such materials. The soil should be ftesh from quarry. The colour of the soil generally be red. The soil will be measured by measuring box.(Farma) (Item includes Royalty charges,, Transporting, Ioading unloading etc.) lead charges for 30 k.m. is considered. |
| 89 | Providing material and labor FARM YARD MANURE : Supplying on site well decayed, well dried, well powdered, without clods and free from stones, dried grass and other rubbish material. The colur of the manure generally be black. The manure will be measured by measuring box. (Farma) (Item includes Transporting, loading unloading etc.) lead charges for 20 km is considered. |
| 90 | Providing labour for MIXING GARDEN SOIL/SILT & MANURE THROUGHLY WELL, Watering Pervious night, Planting required plant species, lawn gress as dricted etc. complete. |
| 91 | Providing material and labor for LAWN :- Supplying and planting reuired variety of lawn grass as directed and maintaining till well established by watering, weeding clipping, rolling etc. complete. |
| 92 | Providing material and labor for TREES:- (minium height to 3 mtr.):- digging pit with size 0.9mx0.9mx0.9m removing and conveying unwanted stuff to a required stuff to a required distance as directed. Filling the pit with approved excavated material up to a height of 0.30m. And remining height of 0.60m with fresh garden soil and manure in 3:1 proportion . mixing soiland manure thoroughly well, levelling, as directed , watering previous night, planting two to three year old , minimum 2.0 mtr. height , healthy trees sapling as per specification. maintaining till well established by watering , weeding, stirring of soil staking replacing of casualties etc. complete. |
| 93 | Providing material and labor for TREES:-( height to 1.5 mtr.):- digging pit with size 0.9mx0.9mx0.9m removing and conveying unwanted stuff to a required stuff to a required distance as directed. Filling the pit with approved excavated material up to a height of 0.30m. And remining height of 0.60m with fresh garden soil and manure in 3:1 proportion . mixing soiland manure thoroughly well, levelling, as directed , watering previous night, planting two to three year old , minimum 2.0 mtr. height , healthy trees sapling as per specification. maintaining till well established by watering , weeding, stirring of soil staking replacing of casualties etc. complete. |
| 94 | TREES:-Supply and erecting Morpankhi Hedges (minium height to 2.5 mtr)- digging pit with size 0.9mx0.9mx0.9m removing and conveying unwanted stuff to a required stuff to arequired diatance as directed. Filling the pit with approved excavted material up to a height of 0.30m. And remining height of 0.60m with fresh garden soil and manure in 3:1 proporation . mixing soiland manure thoroughly well, levelling, as directed , watering previous night, planting two to three year old , minium 2.0 mtr. height , healthy trees sapling as per specification. maintaning till well established by watering , weeding, stirring of soil staking replacing of casualties etc. complete. |
| 95 | HENNA PLANTATION :- Excavting the ground to required depth of 30 cms, removing and coveying unwanted stuff to a required depthas directed. Filling fresh garden soil and manure in excavted area 3:1 poroporation to a height of 30 cms. Mixing garden soil and manure thoroughly well developed shurbs plants, 0.50 mtr. height, 0.45mtr.apart as directed and maintaining till well eastabilished by watering, weeding, stirring, replacing casualtiies etc. complete |
| 96 | Preparing Shrubbery:- Excavting the ground to required depth of 30 cms, removing and coveying unwanted stuff to a required depthas directed. Filling fresh garden soil and manure in excavted area 3:1 poroporation to a height of 30 cms. Mixing garden soil and manure thoroughly well developed shurbs plants, 0.50 mtr. height, 0.45mtr.apart as directed and maintaining till well eastabilished by watering, weeding, stirring, replacing casualtiies etc. complete |
| 97 | SITC Filter 2000 mm dia. Bobbin Wound, non-corrosive Fibre Glass reinforced, UV resistant Tank. Internal surface of the tank finished with water resistant resin. Sperical tank with uniform wall thickness. Internally fitted with bell mouth assembly for even distribution of water over media bed and bottom header lateral assembly for collection of filtered water. 160 mm flanged connections and manhole. Operating Pressure : Maximum Flow Rate : 125 M3/hr. Make: HYDRON OR .as approved by Engineer-in-Charge Complete. |
| 98 | SITC Pump Model :Flow Rate : 126 cu.m./hr. @ 10 MWC Make : KIRLOSKAR/CRI /EQUI Suction / Delivery : 6” Power : 10HP M. O. C. : Cast Iron with SS Impeller .as approved by Engineer-in-Charge Complete. |
| 99 | SITC 5 Way 6\" outlet manifold Valve Battery Make: Hydron.as approved by Engineer-in-Charge Complete. |
| 100 | SITC MEDIA Silica 0.5 mm to 0.8 mm fine sand.as approved by Engineer-in-Charge Complete. |
| 101 | SITC MAIN DRAIN Size : 1500 mm x 1500 mm M. O. C. : ABS with SS ScrewS.as approved by Engineer-in-Charge Complete. |
| 102 | SITC BOTTOM INLT NOZZLES Flow regulable inlet nozzles with screws Size : 2\" Flow Rate : 12 M3/hr.as approved by Engineer-in-Charge Complete. |
| 103 | SITC Chemical Dosing System For pH Correction and Chlorine DosingPump : ElectromagneticFlow Rate : 0 - 5 lph.Flow Adjustment : ManualChemical Day Tank : 100 litres(3) |
| 104 | Supply & installation with all allied fittings,support & testing of PVC pipe with resistant ofworking pressure not less then 6Kg/sqcm.Following ASTM standards.Dia of pipe.1-10MM ,2-200MM Note: We will provide all fittings all Pipe Fittings,Valves & Pipes according to requirement for 200mm Dia Vessel (3 sistens) in 1 lot.as approved by Engineer-in-Charge Complete. |
| 105 | SITC Under Water Light, Make : HydronVolts / Watts : 9W/12W M O C : SS Type : LEDas approved by Engineer-in-Charge Complete. |
| 106 | SITC Panel Board For Pumps On/Off with timer & Controllers.as approved by Engineer-in-Charge Complete. |
| 107 | SITC Vacuum Head : Stainless Steel 900 mm x 200 mm head with wheels, twin nylon and 50 NB hose connection. as approved by Engineer-in-Charge Complete. |
| 108 | SITC Suction Sweeping Pump(Mud Pump MOC: CI) Flow Rate : 24 cu.m./hr.@ 6 MWC Make :HYDRON Suction / Delivery : as approved by Engineer-in-Charge Complete.Motor :3HP, 3 Phase, 415 Volts, A C Supply, 50 Hz |
| 109 | SITC Floating Hose: Copolymer Floating Vacuum hose 2\" Dia. 15 Meters long.as approved by Engineer-in-Charge Complete. |
| 110 | SITC Deep Bag NeIn PP and white polyester netting with clip type connection.as approved by Engineer-in-Charge Complete. |
| 111 | SITC Surface NetIn PP and white polyester netting with clip type connection.as approved by Engineer-in-Charge Complete. |
| 112 | SITC Curved Brush18\" brush made in PP for pool basin and scm liner with clip type connection.as approved by Engineer-in-Charge Complete. |
| 113 | SITC Aluminum telescopic Handle 2.4 Meters length for clip type connection.as approved by Engineer-in-Charge Complete. |
| 114 | SITC Algae Brush 18\" brush with SS bristles and clip type connection. as approved by Engineer-in-Charge Complete. |
| 115 | SITC LaddersThree Steps :End Connections : FlangedTreads : SS 304 Non Slip.as approved by Engineer-in-Charge Complete. |
| 116 | SITC Ladders Four Steps : End Connections : Flanged Treads : SS 304 Non Slip.as approved by Engineer-in-Charge Complete. |
| 117 | SITC Life Buyos-5 NOS Life Guard Loop-2NOS Test Kit for Free Chlorine and pH -2NOS as approved by Engineer-in-Charge Complete. |
| 118 | SITC Over Flow Greetings (12”).as approved by Engineer-in-Charge Complete. |
| 119 | Providing and fixing to wall ceiling and floor 6.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(A) 20mm |
| 120 | Providing and fixing to wall ceiling and floor 6.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(B) 25mm |
| 121 | Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(C) 32mm |
| 122 | Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(D) 40mm |
| 123 | Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(E) 50mm |
| 124 | Providing and fixing in position cowel went to pipes.(B) 75mm dia. |
| 125 | Providing and fixing in position cowel went to pipes.(C) 100mm dia |
| 126 | Providing and fixing screw down bib taps of following size.(B) Brass chromium plated screws down Bib Tap. (i) 15mm dia. |
| 127 | Providing and fixing Gun metal check or non-returnfullway wheel valve.(A) 15mm dia. |
| 128 | Providing and fixing Gun metal check or non-returnfullway wheel valve.(B) 20mm dia. |
| 129 | Providing and fixing Gun metal check or non-returnfullway wheel valve.(C) 25mm dia. |
| 130 | Providing and fixing Gun metal check or non-return fullway wheel valve.(D) 32mm dia. |
| 131 | Providing and fixing Gun metal check or non-returnfullway wheel valve.(E) 40mm dia. |
| 132 | Providing and fixing ball cock of approved. quality asdirected.(B) Abonite (ii) 50mm dia. |
| 133 | Providing and fixing G.I. Rain water spout of 50mm dia. and 30cm. length. |
| 134 | Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete.[A] 15 mm. |
| 135 | Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [B] 20 mm. |
| 136 | Providing laying and jointing in true line and level 15mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials. |
| 137 | Providing laying and jointing in true line and level 25mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials. |
| 138 | Providing laying and jointing in true line and level 32mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials. |
| 139 | Providing laying and jointing in true line and level 40mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials. |
| 140 | Providing laying and jointing in true line and level 50mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials. |
| 141 | Providing, laying and jointing in true line and level 160 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 160 mm diametre x 210 mm length x 196 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. |
| 142 | Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. |
| 143 | Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 mm diameter with jali of the following nominal diameter of self cleansing design with C.I scread down or hinged grating including the cost of cutting and making good the walls. |
| 144 | Providing erecting and fixing double coated ISI water tank of required capacity each with all necessary fittings and connection etc. complete on terrace |
| 145 | Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water tight C.I. cover with frame of 300mm x 300mm size (inside) with standard weight.(i) Square mouth traps. (A) 100mm x 100mm size P type. |
| 146 | Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(B) 150mm |
| 147 | Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(C) 250mm |
| 148 | Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1- cement :2-coarse sand : 4-graded stone aggregate 20mmnominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:3 (1- Cement : 3-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (1) A type depth 0.90 Metre for 150mm diameter sewer. |
| 149 | (I) Extra rate for constructing B.B. masonry for every additional depth of 0.1M. or Part thereof over item No.24.27 (I) for depth from 0.9M to 1.5M. |
| 150 | Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1- cement :2-coarse sand : 4-graded stone aggregate 20mmnominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:3 (1- Cement : 3-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (2) B type depth 1.50 Metre for 150mm diameter sewer. |
| 151 | (II) Extra rate for constructing B.B. masonry for everyadditional depth of 0.1M. GR Part thereof over item No.24.27 (I) for depth from 1.50M. to 2.25M. |
| 152 | Providing and fixing cast iron steps of size 500mm x150mm x 22.5mm and painting with two coats of Anti corrosive paint etc. complete. |
| 153 | Constructing brick masonry chamber for underground C.I. Inspection chamber and bends with bricks having crushing strength not less than 35Kg/Cm2 in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x 610mm intenal dimensions total weight of cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1 cement :2- coarse sand :4-graded stone aggregate 20mm size) foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete.(i) Inside dimensions 455mmx 610mm and 450mm deep for single pipe line. |
| 154 | Extra over items 24.44 for every additional depth of0.1M. of part thereof beyond 450mm depth for Brickmasonry chamber.(i) for 455mm x 610mm size. |
| 155 | Constructing brick masonry chamber for undergroundC.I. Inspection chamber and bends with bricks havingcrushing strength not less than 35Kg/Cm2 in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x 610mm intenal dimensions total weight of cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size) foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete.(ii) Inside dimensions 500mm x 700 mm and 450mm deep for pipe line with one or two inlets. |
| 156 | Extra over items 24.44 for every additional depth of0.1M. of part thereof beyond 450mm depth for Brickmasonry chamber.(ii) for 500mm x 700mm size. |
| 157 | Constructing brick masonry chamber for underground C.I. Inspection chamber and bends with bricks having crushing strength not less than 35Kg/ Cm2 in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x 610mm intenal dimensions total weight of cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1 cement :2- coarse sand :4-graded stone aggregate 20mm size) foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete.(iii) Inside dimensions 600mm x 850 mm and 450mm deep for pipe lines with three or more inlets. |
| 158 | Extra over items 24.44 for every additional depth of0.1M. of part thereof beyond 450mm depth for Brickmasonry chamber.(iii) for 600mm x 850mm size. |
| 159 | Providing and fixing on platform stainless steel Sink glossy ASIS 304 grade x 1mm thick with over all size 610x460mm & bowl size 560x410x200mm & SS Pillar cock with extention bodylike JAQUAR FUS-CHR-29021Nincluding fixing the sink in platform & making good the same including the cost of PVC waste pipe of 32mm dia. and PVC waste coupline etc complete as directed by EIC. |
| 160 | Providing and fixing Two way BIB cock with wall flangeof genuine Jaquar ompany brand, inwith model no FUS-CHR29041, water tap brand or approved ISI brand quality,fixing in pieline and testing the same… etc., complete., as directed by EIC |
| 161 | Providing and fixingwash down water closet European type WC pan (Wall Hung) like JAQUAR CNS-WHT-961SPP- SIZE 365x545x360MM and P trap distance 23.5 cms with integral P trap including jointing the trap with soil pipe in cement mortar 1:1 (1 cement : 1 find sand) including providing and fixing of 1)Health Faucet hand shower heavy duty with SS braided hose 1.2 MT long pipe to water closet - JAQUAR ALD-CHR-573 with Single Piece Slim Concealed Cistern Body with Installations Kit & “S-Type” drain pipe connection set for Wall Hung WC (without Flush Control Plate) - JCS-WHT-2400S with Control Plate Opal - JCP-CHR-152415,Toilet roll holder -Jaquar -ACN -1151N etc,complete |
| 162 | Providing and fixing Wash Basin vitreous china table topwash basin size 560mm x 450 mm in white colour. Like JAQUAR CNS-WHT-903 SIZZE OF 425x340x175MM with single hole for pillar tape with CP or MS brackets painted white including cutting holes and making good the same including (1) Providing and fixing SS waste couplingof 32 mm dia size half theread with 80mm height like jaquar -ALD - CHR-705for wash basin with rubber plug (2) Providing and fixing SS bottle trap with internal partition of 32mm size with 250mm &190mm long wall flange connection pipes and wall flange likejaquar ALD-769 L250X190 of approved quality with necessary fitting for wash basin (3) Providing and fixing SS Pillar cock with extention bodylike JAQUAR FUS-CHR-29021N with necessary fittings etc. complete (4) Providing and fixing SS finish Angular Stop Cock quarter turnlike Jaquar code FUS-29053 with necessary fittings (5) Providing and fixing SS finish soap dispenser with metallic bottle like Jaquar code-ACN-CHR-1135N,Towel ring -jaquar-CAN-1121BN etc. complete |
| 163 | Providing and fixing Urinal of approved quality including connection with trap and with integral longitudinal flush pipe.(A) Squating plate pattern white earthenware size of urinal370mm x 315x 620 mm.of jaquar make code no URS -WHT-132530including (1) Providing and fixing SS finish waste couplingof 32 mm dia size half theread with 80mm height like jauar -ALD - 709 for wash basin with rubber plug (2) Providing and fixing SS finish bottle trap with internal partition of 32mm size with 250mm &190mm long wall flange connection pipes and wall flange like jaquar ALD-769 of approved quality with necessary fitting for wash basin (3) SS finish flush valve of auto closing system like jaquar PRS-073 of approved quality and connection with waste pipe trap etc. complete |
| 164 | Providing and fixing U PVC SCH40 for cold water 20 mm dia (3/4)\" |
| 165 | Providing and fixing PVC SWR pipes IS 13592 for Drain - 75 mmdia |
| 166 | Providing and fixing PVC SWR P- Trap IS 14735 for Drain -110x110 |
| 167 | Providing and fixing Gun metal check or non-return fullway wheel valve. (A) 50mm dia. |
| 168 | Providing laying and jointing PVC SWR pipes IS 13592 for Drain - 50 mmdia it\"s accessories. |
| 169 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 170 | Providing and fixing SS finish Angular Stop cock for wash basin like Jaquar code FUS-29053 |
| 171 | Providing laying and jointing in true line and level 65mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials. |
| 172 | Providing and fixing Gun metal check or non-return fullway wheel valve. (A) 65mm dia. |
| 173 | Point wiring for Light / Bell with2-1.5 sq.mm& earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length , in below type of pipe erectedwith 6A Modular type switch / bell push & accessories and earth continuityof following type, erected on PVC / Metallic/Wooden box, single mounting base framecovered with textured/metallic/white front plate modules erected on /in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.(f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete cat III |
| 174 | PointwiringforTissino/Modularsecondarylight point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVCinsulatedmultistrandcopperwires,inbelow typeof pipetobeerected completewithearth continuityandnecessaryconnectionwithprimary lightwithaccessorieserectedon Metal/ PVC/ wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic sheetfor open / concealedwiring.withnecessaryLampholder/ ceiling rose / H.D.Connector as directed.Note:- Maximum up to 6 mtrs length, excess will be considered asMains for Secondary Point.(f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete cat III |
| 175 | Point wiring for FAN with 2-1.5 sq.mm& earth wire of1.5sq.mm(Green)bothareof.ISImarked1.1 KV GradeFRLS PVC insulated multi strand copper wiresupto10mtrlength,inbelowtypeofpipe erectedwith 6A Modular type switch and hum free EME steptypeelectronicfanregulator mounted and accessorieswithearthcontinuityoffollowing type erected on PVC / Metallic/Wooden box, single mountingbaseframecoveredwith textured/metallic/white frontplate modules erected on/inwall/ceilingasperpipeerected.with necessary ceiling rose / H.D.Connector as directed.(f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete cat III |
| 176 | Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm& earth wire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires erected in below type of pipe with 6A Modular type switches and following type of accessories erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate modules erected on / in wall / ceiling as per pipe erected. with necessary batten/angle holder or ceiling rose or H.D.Connector as directed.(f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete |
| 177 | Point wiring for Individual Plug with& earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erectedcomplete with Modular type switch & 5 pin Plugerected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories [II]For16APlugand16ampswitch with2-2.5 sq.mm Cu. Wire from mcb db board.(f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete cat III |
| 178 | Point wiring for Individual Plug with& earth wire of1.5sq.mm(Green)bothareofISImarked1.1 KV gradeFRLSPVCinsulatedmultistrandcopper wiresupto10mtrlength,inbelowtypeofpipe erectedcomplete with Modular type switch & 5 pin Plugerected on PVC / Metallic/Wooden box coveredwithappropriatefrontplatemodules erected on / in wall / ceiling as per pipe erected with following type of accessories. [I] For 6A Plug and 6 a switchwith 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb db board (f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete |
| 179 | Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured / metallic/whitefront plate modules erectedon/ in wall / ceiling with following type accessories Cat. III |
| 180 | Providing& erecting Switchboard for Computer or electricapparatusconsistingof followingmodular typeaccessories mounted withPVC/Metallic concealed/open box with single mounting base framecoveredwithtextured/metallic/whitefront plate,moduleserectedwithnecessaryconnections as directed1 no. 6A/16A universal plug-switchcombined. 3 nos. 6A Switch3 nos. 6A 5 pin PlugFor Modular Type Accessories Cat. III |
| 181 | Providing following type of Modular Type AccessoriesmountedwithPVC/metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erected withnecessaryconnectionsaspersite situation directed by Engineer In charge.(8)ComputerRJ-45 socketCat.III |
| 182 | Supplying & erecting approved make LAN cable of following size in existing pipe as per direction [D] CAT - 6 e |
| 183 | Supplying & erecting approved 24 port gigabyte unmanaged switch. |
| 184 | Supplying & erecting access point with POE. |
| 185 | Supply,Installation,Testing and Commissioning of Table mount Modular Multi-connection Cable Manager Should have an easy openable retractable lid which disappears with a single tap of a button. |
| 186 | SITC of Patch Panel Cat 6 UTP Keystone Type- 24 Port-Fully Loaded(Including Five year free maintenance with guarantee) |
| 187 | SITC of CAT6 UTP 24AWG PATCH CORD:1M,Plug 30U\" Snag less [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] |
| 188 | SITC of CAT6 UTP 24AWG PATCH CORD:2M,Plug 30U\" Snag less[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] |
| 189 | Providing & Erecting Netwrok rack with following capacity with Necessary cooling fan,Cable manager,6A PDU,equipment rack with necessary mounting accessories.(A) 9 U |
| 190 | Providing following type of Modular Type AccessoriesmountedwithPVC/metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erected withnecessaryconnectionsaspersite situation directed by Engineer In charge.(3) Two Pin/RJ-11 Telephone Socket[A] For One Gang Cat.III |
| 191 | Supplying&erectingapprovedmakeTelephone CableelectrolyticcopperconductorPEinsulation twistedintwopairs,&wrappedwithFRLSPVC tape&sheathedwithFRLSPVCorHFFRouter Jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors&nos.ofpairs.Withnecessary connections.[A] Conductor Size 0.5 mm(a) Unarmoured (2)Two Pairs |
| 192 | Providing & erecting main Distribution (MDF) indoortype,backmountedframeasperDoTstandard approved with krone strips(a) Suitable for 10 pair |
| 193 | Providing & erecting main Distribution (MDF) indoortype,backmountedframeasperDoTstandard approved with krone strips(b) Suitable for 20 pair |
| 194 | SITC of Digital / PCM / TDM EPABX System having SMT design, system with flexible universal slots. Inbuilt Auto attendant facility, Minimum 15 Nos. conference, Analog extension line, Calling GSM, E&M line, PRI / EI & VOIP program me through Analog telephone digital key from Ethernet, public address cord, shall have unrestricted simultaneous dialing facility,QSIG protocol on PRI, 95 / STD / ISD / Local-Locking, Class of Service, Quick Dial-Single Digit dialing of any two external number, Once only ring device, Chairman / Secretary - Do not disturb Facility, Power Down Mode, Hot Line, Hot Outward Dialing, Day Night Mode, Auto Call Back, Barge-in, Call Pick Up & Call Transfer, Call transfer while Ringing with Voice Guide System, (DISA), Caller ID (CLI), CLI Base ECF, CLI Base routing Internet Ready Port, External Music Port, Call Budgeting, Call Most Calculation (ASMDR), DID Direct Inverse Dialing, External Music Input, Fax Homing, Global Directory Printing with following capacities [[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ][A] No of Extension 16, No of Junctions 6, 8 Port IP Resource in-built, 4 Port Web base Video Conferencing, No of expandable ports : 48, Operators Console - 01 Compatible : ISDN |
| 195 | providing and erecting Mains with ISI marked, 1.5KVgradeelectrolytemultistranded,annealed copper conductor with heat resistant PVC insulated conformstoIS694,IEC-227erectedinexisting pipe offollowing size (Specifically for control panel, relays, power switchgears, motor starters & control wiring)withrequiredsizeofcopperlugs,nutsand bolts if required.(f)One wire 10.00 sq. mm |
| 196 | providing and erecting Mains with ISI marked, 1.5KVgradeelectrolytemultistranded,annealed copper conductor with heat resistant PVC insulated conformstoIS694,IEC-227erectedinexisting pipe offollowing size (Specifically for control panel, relays, power switchgears, motor starters & control wiring)withrequiredsizeofcopperlugs,nutsand bolts if required.(g)One wire 16.00 sq. mm |
| 197 | providing and erecting Mains with ISI marked, 1.5KVgradeelectrolytemultistranded,annealed copper conductor with heat resistant PVC insulated conformstoIS694,IEC-227erectedinexisting pipe offollowing size (Specifically for control panel, relays, power switchgears, motor starters & control wiring)withrequiredsizeofcopperlugs,nutsand bolts if required.(h)One wire 25.00 sq. mm |
| 198 | providing and erecting Mains with ISI marked, 1.5KVgradeelectrolytemultistranded,annealed copper conductor with heat resistant PVC insulated conformstoIS694,IEC-227erectedinexisting pipe offollowing size (Specifically for control panel, relays, power switchgears, motor starters & control wiring)withrequiredsizeofcopperlugs,nutsand bolts if required.(i)One wire 35.00 sq. mm |
| 199 | ProvidinganderectingMainswith1.1KVgrade FRLSPVCinsulatedISImarkedstrandedCopper conductor wire in following typeof pipetobe erectedconcealedin/flushedonwall/ceiling,with1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity offollowing size. (A) With medium class Rigid PVC pipe and accessories (a) 2 wire 1.5 sq. mm |
| 200 | ProvidinganderectingMainswith1.1KVgrade FRLSPVCinsulatedISImarkedstrandedCopper conductor wire in following typeof pipetobe erectedconcealedin/flushedonwall/ceiling,with1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity offollowing size. (A) With medium class Rigid PVC pipe and accessories(b) 2 wire 2.5 sq. mm |
| 201 | providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size(A) With medium class Rigid PVC pipe and accessories (a) 2 wire 4 sq. mm |
| 202 | providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size(A) With medium class Rigid PVC pipe and accessories (c) 2 wire 10 sq. mm (use earth wire of 4 sq.mm ) |
| 203 | providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size(A) With medium class Rigid PVC pipe and accessories (g) 4 wire 4 sq. mm |
| 204 | Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceilingerected with necessary PVCfittings&Junctionboxesfixedwithadhesive solution&Clampswithfollowingdiaofpipes,inapproved manner as directed (b) 25 mm |
| 205 | Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC bushes, Check-nuts etc. complete of followingsizes.(2) 25 mm |
| 206 | Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mountedfittedwithbusbar,neutrallink,earth barandDINrail,ConformstoIS8623-1&3, IEC 61439-1 & 3 without MCB to house appropriate nos. ofMCBs.(The DBsshould be usedofsamecompanyofMCBtobeused) suitable for(A) single phase incoming and horizontal single phase outgoing(b) sheet steel double door (IP-43) (ii)6 way |
| 207 | Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mountedfittedwithbusbar,neutrallink,earth barandDINrail,ConformstoIS8623-1&3, IEC 61439-1 & 3 without MCB to house appropriate nos. ofMCBs.(The DBsshould be usedofsamecompanyofMCBtobeused) suitable for(A) single phase incoming and horizontal single phase outgoing(b) sheet steel double door (IP-43) (iii)8 way |
| 208 | Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mountedfittedwithbusbar,neutrallink,earth barandDINrail,ConformstoIS8623-1&3, IEC 61439-1 & 3 without MCB to house appropriate nos. ofMCBs.(The DBsshould be usedofsamecompanyofMCBtobeused) suitable for(B)threephaseincomingandsinglephase horizontaltypeoutgoing Perphaseisolationtype (PPI)(b) sheet steel double door (IP-43) (i)4 way |
| 209 | Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mountedfittedwithbusbar,neutrallink,earth barandDINrail,ConformstoIS8623-1&3, IEC 61439-1 & 3 without MCB to house appropriate nos. ofMCBs.(The DBsshould be usedofsamecompanyofMCBtobeused) suitable for(B)threephaseincomingandsinglephase horizontaltypeoutgoing Perphaseisolationtype (PPI)(b) sheet steel double door (IP-43) (ii)6 way |
| 210 | Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mountedfittedwithbusbar,neutrallink,earth barandDINrail,ConformstoIS8623-1&3, IEC 61439-1 & 3 without MCB to house appropriate nos. ofMCBs.(The DBsshould be usedofsamecompanyofMCBtobeused) suitable for(B)threephaseincomingandsinglephase horizontaltypeoutgoing Perphaseisolationtype (PPI)(b) sheet steel double door (IP-43) (iii)8 way |
| 211 | providing and erecting Miniature circuit breaker singlepole6Ato25Asuitabletooperateon240 V A.C. system and having breaking capacity 10KAtobeerectedinexistingbox. confirming to IS 8828/1996 with ISI Mark Cat.III |
| 212 | Providing&erecting240VMCBdoublepole switch for lighting Load (B Curve) having 10 KA breakingcapacity&confirmstoIS:8828in existing box having following capacity(A) 6 to 32 Amp. Cat-III |
| 213 | Providing&erecting240VMCBdoublepole switch for lighting Load (B Curve) having 10 KA breakingcapacity&confirmstoIS:8828in existing box having following capacity(B) 40 Amp. Cat-III |
| 214 | Providing & erecting 415 V MCB Four Polefor Motor & InductiveLoad (C Curve) having 10KA breakingcapacity&confirmstoIS:8828in existing box having following capacity(a) 6 to 32 Amp. Cat III |
| 215 | Providing & erecting 415 V MCB Four Polefor Motor & InductiveLoad (C Curve) having 10KA breakingcapacity&confirmstoIS:8828in existing box having following capacity(c)63 Amp.Cat.III |
| 216 | providing and erecting Approved make RCCBs conformingtoIS:12640 andhaving sensitivity of30mAandShortCircuitwithstandcapacity of10KAandsuitableforoperationonsingle phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. ratingerected as directed (i) 25 Amps.DP Cat. III |
| 217 | providing and erecting Approved make RCCBs conformingtoIS:12640 andhaving sensitivity of30mAandShortCircuitwithstandcapacity of10KAandsuitableforoperationonsingle phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. ratingerected as directed (ii) 40Amps. DP Cat. III |
| 218 | providing and erecting Approved make RCCBs conformingtoIS:12640 andhaving sensitivity of30mAandShortCircuitwithstandcapacity of10KAandsuitableforoperationonsingle phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. ratingerected as directed (iii) 63 Amps. DP Cat. III |
| 219 | Supplyinganderectingtriplepole&neutral 440V/500VpanelmountingCopperBusbars withfourequalNos.ofelectrolytebushaving current density not more than 1.6 Amp. / sq.mm(Ratedcurrent/crosssectionarea) dulywrappedwithcolourinsulatingtapefor phasesequenceoffollowingcurrentcarrying capacity, erected with necessary bus bar supports /insulators, main cable socket to each bar, erected in existing cubical panel with necessaryconnections.(A) Suitable for 100 Amp. Capacity |
| 220 | Supplyinganderectingtriplepole&neutral 440V/500VpanelmountingCopperBusbars withfourequalNos.ofelectrolytebushaving current density not more than 1.6 Amp. / sq.mm(Ratedcurrent/crosssectionarea) dulywrappedwithcolourinsulatingtapefor phasesequenceoffollowingcurrentcarrying capacity, erected with necessary bus bar supports /insulators, main cable socket to each bar, erected in existing cubical panel with necessaryconnections.(B) Suitable for 200 Amp. capacity |
| 221 | Supplyinganderectingtriplepole&neutral 440V/500VpanelmountingCopperBusbars withfourequalNos.ofelectrolytebushaving current density not more than 1.6 Amp. / sq.mm(Ratedcurrent/crosssectionarea) dulywrappedwithcolourinsulatingtapefor phasesequenceoffollowingcurrentcarrying capacity, erected with necessary bus bar supports /insulators, main cable socket to each bar, erected in existing cubical panel with necessaryconnections.(E) Suitable for 630 Amp. capacity |
| 222 | ProvidinganderectingApprovedmakeFour pole moulded case circuit breaker having breaking capacity ICU of 25 KA. at 415 V,havingnormalcurrentratingupto25Ato 100A.withFixedthermal&magneticrelease suitable to work on A.C. supply 50 c/s. with all internal connections, spreader tinned copper & completeerectedinexisting16G.M.S. housing. |
| 223 | Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating125A. with Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. |
| 224 | Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 50 KAand above at 415 Vhaving Normal current rating400A. with variable Thermal & magnetic release suitable to work on A.C.supply 50 c/s. With all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing.Cat III |
| 225 | Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 50 K.A.and above at 415 Vhaving normal current rating up to 630A. with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housingCat III |
| 226 | Supplying & erecting approved make Four Pole 415V change over switch interior for panel mounting with operating mechanism A.C.23 duty confirming to IS for (G) 630 A. Cat.III |
| 227 | Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor typecubical panel board necessary IP- 42 and above protection as per approval from engineerinchargemadefrom14SWGthick CRCM.S.sheetforouterbody&doors,16 SWGthickCRCM.S.sheetforinternal partitions with necessary accesories , supporting angles/ flats channel including cutting,bending,drilling,welding,rivetingwith internalpartitions&cablealleyasper requirements&instructionofengineer-in- charge with erection of supplied switch gears, BUSBARS,suitable sizeofinterconnectingPVCcopperwire/ copper-aluminium strips, rubber grommets, rib, bakelitecontrolfuses/MCBformeasuring instruments, earth bus & earth bolts, foundation flange-bolts-basePlates,sufficientnos.of hinged doors, handles with locking arrangement and rubber gasket,heavy duty end terminal connection,danger notice board,necessary ventilation,earthing strip complete. The Panel shall be painted with epoxy powder coating (Theratesexcludesthecostofswitchgears, busbars,interconnectingmains &Copper Aluminium strips,meters, Fuses etc. The dimensionshallbemeasuredexcludingbase beams) The panel shall be supplied with followingapprovedmanufacturerswithfollowing size.(B)Thestandardcompaniesswitchgearshall be used and only manufacturers at CPRIapproved factory. (i) with 350mm depth board |
| 228 | Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor typecubical panel board necessary IP- 42 and above protection as per approval from engineerinchargemadefrom14SWGthick CRCM.S.sheetforouterbody&doors,16 SWGthickCRCM.S.sheetforinternal partitions with necessary accesories , supporting angles/ flats channel including cutting,bending,drilling,welding,rivetingwith internalpartitions&cablealleyasper requirements&instructionofengineer-in- charge with erection of supplied switch gears, BUSBARS,suitable sizeofinterconnectingPVCcopperwire/ copper-aluminium strips, rubber grommets, rib, bakelitecontrolfuses/MCBformeasuring (iv) with 1000 mm. depth |
| 229 | Providing , erecting , fabricating the M.S. structure as per requirement on site incorporating proper size of M.S. angles,square,round,flats,bars,channels, sections completewithcutting,welding, grinding&finishingdulypaintedwithonecoat of red oxidewith erection on site as per directionofengineerinchargewithnecessary grouting, cementing, plastering & finishingcomplete. |
| 230 | Supplying and erecting approved make suitable panel indicatorLED type lamp, lens cover, complete erected with necessary connections. |
| 231 | Providing & erectingL.T. Current Transformer withbarprimary50/5to1000/5ratio15VA burden erected in existing CRCA box duly securedwithinsulatingmaterialsconnectedto the meter. |
| 232 | Providinganderectingmetallicvitrifieddanger noticeboardasperlanguagesuggestedby engineer incharge for MEDIUM VOLTAGE installation to be erected as per IS-2551. |
| 233 | Providing following type of Modular Type AccessoriesmountedwithPVC/metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erected withnecessaryconnectionsaspersite situation directed by Engineer In charge.(7) Blank Plate Single |
| 234 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for1.1 KV. to be laidon wall with necessary clamps or in existing trench/ pipe of following size of cables. (C) 3 core 6 Sq. mm |
| 235 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armouredcablemultistrandAluminium conductorfor 1.1KV.tobelaid onwallwith necessary clamps or in existing trench/ pipe of following size of cables(B) 3 1/2core 35 Sq. mm ( 16 Sq. mm 1/2 core) |
| 236 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armouredcablemultistrandAluminium conductorfor 1.1KV.tobelaid onwallwith necessary clamps or in existing trench/ pipe of following size of cables(C) 3 1/2core 50 Sq. mm ( 25 Sq.1/2 mmcore) |
| 237 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armouredcablemultistrandAluminium conductorfor 1.1KV.tobelaid onwallwith necessary clamps or in existing trench/ pipe of following size of cables(F) 3 1/2core 120 Sq. mm ( 70 Sq. mm 1/2 core) |
| 238 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armouredcablemultistrandAluminium conductorfor 1.1KV.tobelaid onwallwith necessary clamps or in existing trench/ pipe of following size of cables(I) 3 1/2 core 240 Sq. mm( 120 Sq. mm1/2core) |
| 239 | Providing and erecting XLPE (IS:7098)(I)-88 ISI armouredcablemultistrand/SolidAluminium conductorfor 1.1KV.tobelaid onwallwith necessary clamps or in existing trench/ pipe of following size of cables(B) 4 core 6 Sq. mm |
| 240 | Providing and erecting XLPE (IS:7098)(I)-88 ISI armouredcablemultistrand/SolidAluminium conductorfor 1.1KV.tobelaid onwallwith necessary clamps or in existing trench/ pipe of following size of cables(C) 4 core 10 Sq. mm |
| 241 | Providing and erecting XLPE (IS:7098)(I)-88 ISI armouredcablemultistrandAluminium conductorfor 1.1KV.tobelaid onwallwith necessary clamps or in existing trench/ pipe of following size of cables (A) 4 core 16 Sq. mm |
| 242 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copperconductor for1.1 KV. to be laidon wall with necessary clamps or in existingtrench/ pipe at road crossing or floorof followingsize of cables.(A) 4 core 16 Sq. mm |
| 243 | Providingand,fixingheavydutyflangetype brasscableglandwithrubberringforPVC insulatedarmouredcablecompletewithout going tails, insulating tape etc for following size of cables.(B) 2 to 4 core 6 Sq. mm |
| 244 | Providingand,fixingheavydutyflangetype brasscableglandwithrubberringforPVC insulatedarmouredcablecompletewithout going tails, insulating tape etc for following size of cables.(C) 2 to 4 core 10 Sq. mm |
| 245 | Providingand,fixingheavydutyflangetype brasscableglandwithrubberringforPVC insulatedarmouredcablecompletewithout going tails, insulating tape etc for following size of cables.(D) 2 to 4 core 16 Sq. mm |
| 246 | Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.(B) 3 & 1/2core 35/50 Sq. mm |
| 247 | Providingand,fixingheavydutyflangetype brassdoublecompressiontypecablegland withrubberringforPVCinsulatedarmoured cablecompletewithoutgoingtails,insulating tape etc for following size of cables.(E) 3& 1/2 core 120 Sq. mm |
| 248 | Providingand,fixingheavydutyflangetype brassdoublecompressiontypecablegland withrubberringforPVCinsulatedarmoured cablecompletewithoutgoingtails,insulating tape etc for following size of cables.(H) 3 & 1/2core 240 Sq. mm |
| 249 | Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following sizeevenly crimpedwithhighpressuretool& connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.(A) 1.5/ 2.5/4/6 Sq.mm |
| 250 | Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following sizeevenly crimpedwithhighpressuretool& connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.(B) 10 Sq.mm |
| 251 | Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following sizeevenly crimpedwithhighpressuretool& connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.(C) 16/25 Sq.mm. |
| 252 | Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (C) 16 Sq.mm. |
| 253 | Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following sizeevenly crimpedwithhighpressuretool& connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.(D) 35/50 Sq.mm. |
| 254 | Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following sizeevenly crimpedwithhighpressuretool& connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.(G) 120 Sq.mm. |
| 255 | Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following sizeevenly crimpedwithhighpressuretool& connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.(J) 240 Sq.mm. |
| 256 | Supplying & erecting earth pit of minimum bore dia.150mmsizeapprovedmakeEarthing ElectrodeconsistingPipe-in-PipeTechnology as per IS 3043-1987 made of corrosion free hot dippedG.I.PipeshavingOuterpipediaof 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising,connectionterminaldiaof12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipationsuitableforfollowingtypeof applications with chamber and heavy duty cover. (A)(approvedmake OEM has to submit testcertificateincludingvalueofearth resistance of installation duly stamped and signedbyagencyandofficerInchargehasto ensurethevalueofearthingresistane mentionedintestCertificate)&havingback fillingcompoundof(B) Innerchemical(CCM Compound)- Resistivity:- 0.2 ohm / meter testingasperIEC62561-2017,Voltagedrop:-< 1 volt at no load & dry form, Sulphar content:-<2%(C)BackfillCompound :-Earthing compound should be capable to retain moisture forlongtime Necessarytestreportmustbe submitted by Agency.(c)For ElectricalInstallation covering Transformer Neutrals, Lightning arrester Earthing,A.C.Plant&SensitiveComputer System(like Automation, SCADA) i.e independent Earthing in normal soil.Length of Pipe : 3.00 mtrsBack filling Compound :2 nosBags of 25 Kg. |
| 257 | Providing and erecting required size HOT deep Galvanised iron strip for earthing of H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc. using proper clamp. |
| 258 | Providing and erecting required size Copper strip for earthing of H.T. OCB / ACB/ Transformer, LT panel board, Motors etc. using copper clamp. |
| 259 | ProvidinganderectingAnnealedbareCopperwire 8 to 16 SWG. |
| 260 | Providing & erecting Approved make Power Saving 50 Watt Ceiling Fan with double ball bearing ISI mark with Condenser 230 volt A.C. 50 Hz 1200 mm sweep complete having3blades with aluminium blades with , canopy & 30 cm. down rod erected with earthing.(Make shall be approved by Engineer in charge)) |
| 261 | Supplyinganderecting19/20mm.nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with proper insulation without leakage and earthing. |
| 262 | Supplying& erecting fan hook box of 10 mmM.S. round bar bounded to the RCC bars up to 50mm length each side and pierced through a16GaugeM.S.box/HeavyDutyPVCbox complete erected concealed in Ceiling with necessary finishing. |
| 263 | Providing2.5mm.thicklaminatedacrylicsheetto cover the fan hook or Fan box. |
| 264 | Supplying & erecting approved make low noise decorativeexhaustfanhavingsquareframe ABS body with inbuilt lowers & square frame.200mm with 1350RPM Cat.II |
| 265 | Providing recess in wall or window frame suitableforerectionofExhaustfancomplete with plastering and colour washing to match the colourofthewallorwindowcompletewith expanded metal in order to render the fitting in accessible and the room water-proof. |
| 266 | Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erectedwith necessary connections as per site situation directed by Engineer In charge.(11) 6 Amps. Bell Push |
| 267 | Supplying & erecting Approved make call bell indicator with buzzing sound and Red light indicating lamp with Red light button toattend the call suitable for 240 v 50 c/s supply to be erected. |
| 268 | Supplying and erecting led lamps with following wattage capacity of 220 to 240 voltage, minimum 15000 burning hours life, 500 V in built-surge protection,Polycarbonate diffuser, mounting suitable for E14 / E27 / B22 lamp holders, pf >= 0.5(A) LED Lamps integral type, with PC diffuser suitableLAMP holder (ii)5 to 8 watts CAT III |
| 269 | Supplying and erecting LED indoor fittings with LEDsofwattage0.2Wattto0.5Watt assembledonsingleMCPCB,withhousing usedasaheatsinkshallbemadeofthick sheet Steel conforming to IS: 513/CRCA/aluminiumpressurediecast powder coated and high U.V. & corrosion resistance withdiffuser housedinaluminium casted body with company mark/name 160Vto270V,PowerFactormorethan0.95, THD < 15 %, CCT3000 K to 6500K, Luminaire efficacy> 85 lumens/watt , LED driver efficiency > 85 % ( fitting required LM-79 & LM-80 Certificates)(NOTE:Belowdescriptionhave shown ranges of Wattage capacity of LED fittings.TheEngineerinchargemayselectany wattage capacity between the ranges shown.)(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded mounting clips complete.IP20 (ii) 11-15 watts, Surge-2 KV cat - III |
| 270 | Supplying and erecting LED indoor fittings with LEDsofwattage0.2Wattto0.5Watt assembledonsingleMCPCB,withhousing usedasaheatsinkshallbemadeofthick sheet Steel conforming to IS: 513/CRCA/aluminiumpressurediecast powder coated and high U.V. & corrosion resistance withdiffuser housedinaluminium casted body with company mark/name 160Vto270V,PowerFactormorethan0.95, THD < 15 %, CCT3000 K to 6500K, Luminaire efficacy> 85 lumens/watt , LED driver efficiency > 85 % ( fitting required LM-79 & LM-80 Certificates)(NOTE:Belowdescriptionhave shown ranges of Wattage capacity of LED fittings.TheEngineerinchargemayselectany wattage capacity between the ranges shown.)(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded mounting clips complete.IP20 (iv) 22-24 watts, Surge-2 KVcat - III |
| 271 | Supplying and erecting LED indoor fittings with LEDsofwattage0.2Wattto0.5Watt assembledonsingleMCPCB,withhousing usedasaheatsinkshallbemadeofthick sheet Steel conforming to IS: 513/CRCA/aluminiumpressurediecast powder coated and high U.V. & corrosion resistance withdiffuser housedinaluminium casted body with company mark/name 160Vto270V,PowerFactormorethan0.95, THD < 15 %, CCT3000 K to 6500K, Luminaire efficacy> 85 lumens/watt , LED driver efficiency > 85 % ( fitting required LM-79 & LM-80 Certificates)(NOTE:Belowdescriptionhave shown ranges of Wattage capacity of LED fittings.TheEngineerinchargemayselectany wattage capacity between the ranges shown.)(B) LED Panel Light with provision for Plane front frame with translucent cover fixed to housing complete.IP20(vi)36 watts, 24\" x 24\", Surge- 2KV cat - III |
| 272 | Supplying & erecting recess wall mounting speaker with 5W rated input power 3.3 K. Ohms / 3W impedance, 100 - 10000 Hz frequency response with 6 inch dia. cone type 8 ohms speakers duly fitted in ABS plastic cabinet of colour match with wall or ceiling of following size.[[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ](b)Square shaped 260 x 260mm size speaker |
| 273 | Supplying & erecting Amplifier having following specification:Power Output :250W (RMS) (300W Max.)inputs : 6 Misc. & 2 Aux.frequency Response :50-1500HZ I3dbTone Controls :Cut & Boost typeLED Meter:5 LED ArraysThe amplifier suitable to operate 240V A.C.& 24volt D.C. (Battery) with automatic changeover from AC to Battery operation, duly protected by wrong Battery Polarity connections. [[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] |
| 274 | Supplying, erecting & testing Approved make Microphone for announcement, speech & general P.A. application with frequency response of 150 - 10000 Hz having sensitivity 2mv/Pa, & impedance 600 Ohms supplied with quick detachable holder, 6 mtr twin core cable & PCIM / MCIF connector. [[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] |
| 275 | Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv grade ISI marked copper wires of following size to be erected as directed.(d) 1.50 Sq.mm 2 core round PVC sheathed |
| 276 | Providing & erecting water cooler having storage capacity 150 Ltr. & cooling capacity 150 Ltr.per hour @ an ambient temp of 45˚ C. The outlet temp. of the water should drop by 15˚C within a hour, The water cooler should be comprising of hermetically sealed compressor, fan motor, condensing unit, water tank surrounded by evaporating, coil, thermostats, relay etc.complete with necessary inlet & outlet connection. The body of water cooler will be made from Stainless Steel. |
| 277 | Supplying & erecting reverse osmosis (RO)water purification system with M.S. powder coated pedestal frame, prefilter housing carbon filter suitable buster DC pump, auto low & high pressure switches with following size of LPH capacity & erected as directed [F]500 LPH with3 phase Raw water pump of 1000LPH @ 3.0 kg/cm2 (1No - Kirloskar /CRI /Lubi), Dual media filter 13\"x54\" - (1No),Micron catridge filter 20\" x 4.0\"-1No, High pressure pump 1000LPH @ 11kg/cm2- (1No - lubi/ Shimge/ CRI), RO Membrane housing with RO membrane of 40*40 - (2 Nos), RO pressure tube 4\" x 2E -(1No), 0-2400 LPH Rotameter ( 2Nos), , Dosing pump 0 -6 LPH - (1 No),. with 100 Ltr Dosing tank- (1 No), with Recovery Rate 50%. |
| 278 | S.I.T.C. submersible pump set suitable for bore of 100 mm. dia. or more having three phase motor capacity not more than 5 H.P. with following capacity . Lifting and Lowering taken extra.(B) (16 stage) 140 to 180 LPM discharge at 96 to 69 mtrs. head respectively suitable for 50mm dia. delivery pipe cat III |
| 279 | Providing and erecting ISI marked PVC insulated PVC SheathedFlat flexible Submersiblecopper cable approved make offollowing Size. (C) 3 Core x 4 Sq. mm |
| 280 | Providing & erecting open well type horizontal mono block pump set withstainless steel body having following specification (C) 1 H.P. single phase open well motor pump setsuitable for 185 LPM discharge @ 25 mtr. head, suitable for 32 mm dia. Delivery pipe with control panel.Cat II |
| 281 | Providing & erecting open well horizontal mono block pump set with cast iron body, complete forthree phase submersible motor having[A] For 1.5 HP 3 phase open well horizontal mono block pump set suitable for 190 LPM @ 20 mtr head suitable for 40 mm dia delivery pipeCat II |
| 282 | Providing & erecting open well horizontal mono block pump set with cast iron body, complete forthree phase submersible motor having[C] For 3 HP 3 phase open well horizontal mono block pump set suitable for 85 LPM to 270 LPM @ 11 mtr to 33 mtr head suitable for 50/65 mm dia delivery pipeCat II |
| 283 | Supplying & erecting approved make Automatic liquid level controller 6A. with sensor testing as per instruction of Engineer in charge on site complete with wiring connection with existing wires , with copper conductor from pump to upper and lower tank. |
| 284 | Supplying & erecting approvedmake motor control cubical panel [Star delta] made from 16G CRCA sheet duly epoxy powder painted inside and outside with hinged doors and locking with suitable size of ON - OFF isolator (AC 3 / 23 duty) main fuses. Digital volt and current meter (in a single unit) with micro controller based control unit and current sensing single phasing preventer electronic overload protection, over voltage (Programmable) protection and under voltage (Programmable) protection, prod less dry run protection programming facility for setting of all parameter like overload current, high voltage limit, low voltage limit, dry run limit with digital indication on seven segment LED display for any fault like over load, high voltage, low voltage, dry running single crimped, electronic star delta timer, feather touch start / stop push buttons to be erected on angle iron frame. Grouted on wall the contactors will be of L& T, Siemens, BCH make only)(A) DOL up to 5.0 H.P. |
| 285 | Supplying and erecting approved make Conical Pole (Standard ) Made from HR sheet steel. The pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS 2629/2633/4759 with required base plate and integral Junction box consist of terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and arrangement for cable terminationas erected on suitable foundation (included) with necessary nut-bolts/J-Bolts.as per details given by manufacturer considering site requirement.The length of poles are as below.(E) 7 Mtr. Long 65mm Top X170 mm bottom dia, 3mm thickness. |
| 286 | Providing and erecting street light pole bracket comprising main B Class MS pipe of 4.2 cm/require outside dia. complete with suitable B Class M.S. sleeve tubing of approx. 45cms.length and suitable for 76.5 mm / 80mm. / require size pole top having sufficient fasteners for fixing the brackets and having spread of 1 mtr. length with suitable rise as per site condition & suitable welded stiffener reducer and nipple with check nut complete painted with one coat of Red oxide / PU base primer and two coats of Aluminium / PU paint. paint with following nos of arms. [A] Single Arm bracket 1 Mtr |
| 287 | Supplying & erectingapproved makeSMC press moulded composite FRP.loop-in, loop-out approx. 2mm thick box complete with Bakelite connector strip 5way(3P+N+E),DIN rail for mounting mob& hinged doors as per requirement having locking arrangements with mounting clamp with nuts, bolts & washers suitable for erection on pole with cable clamps& earth bolt of following size of box.(A) 300mm x 200mm x 100mm[deep] |
| 288 | Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glasswith company mark/name engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.(fittings required LM-79 & LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)(A) Street Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply with over-voltage protection. (i) above 36 to 48 watts Cat-lll |
| 289 | (b) LED Bollard fittings of minimum height 600 mm & dia.100mm having polycarbonateclear/milky diffuser mounted on 3mm thick aluminium finished powder coated pipe with base plate 160x160mm with erection by M8x75mm fastner with required RCC foundation.IP65 for 9 to 20 watt,surge-4kv- cat-III |
| 290 | Providing and fixing Terminal board of size 5.0 x 127 x 152.4 mm.bakelite sheet with suitable brass studs with nuts, washers and clamps of size 25mm x 3mm suitable for pole painted with one coat of red lead paint. |
| 291 | Supplying & erecting approved make Digital time switch having lithium cell 6 years operative and operate battery backup 1 channel day clock with 14 memory programme, suitable to operate on 240V + 5%, 16A with, floating contacts Minimum switching setup time 1 minimum & LCD display. Also comprised permanent ON/OFF switching. Programming switches & housed in fire proof thermoplastic enclosure & transparent cover erected as required with necessary connection erected as directed. |
| 292 | Supplying & erecting power contactor ,AC3 duty for time switch complete erected as per direction Cat III (B) 2 pole 250V 32 Amp. |
| 293 | Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv grade ISI marked copper wires of following size to be erected as directed. e) 1.50 Sq.mm 3 core round PVC sheathed |
| 294 | Supplying and erecting B class Galvanized iron pipe having smooth finished bore of the pipe on both ends erectednuts and boltsalong the pole / wall shaping the pipe as per site requirement. Pipe dia as following.(C) 40 mm dia. |
| 295 | Providing and erecting Pipe type earthing with 40 mm dia 2.5 mtr long \"B\" grade G.I. pipe with necessary coupling buch buried in specially prepared earth pit & G.I. earth wire of 8 SWG erected & connected as directed (For panel)For using salt and charcoal / coke as required for pipe type earthing. |
| 296 | Providing & laying approved makeDouble walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connectingaccessories of same material at required depth in existing trenchfor laying ofcable. below ground/ road surface for enclosing cable (A)50 mm outer dia |
| 297 | providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark |
| 298 | Making trench in Hard Murrum / Tar Road of suitable width of 90 cm or requireddepth for laying any size of cable or locating the faultall over the run and back filling the same and making the surface as normal ground. |
| 299 | Making trench in soft soil of suitable width of 90 cm deep for laying cable or locating the faultall over the run and back filling the same and making the surface as normal ground. |
| 300 | Providing and fixing approved make \"T\" Junction for Perforated C type cable tray.Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforationwith coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing supportas per Specification and as per instruction of engineer in charge of following size(2) 100 X 50 X 1.6 mm Thick |
| 301 | Providing and fixing approved make \"T\" Junction for Perforated C type cable tray.Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforationwith coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing supportas per Specification and as per instruction of engineer in charge of following size(5) 300 X 50 X 2.0 mm Thick |
| 302 | Providing and fixing approved make \"T\" Junction for Perforated C type cable tray.Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforationwith coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing supportas per Specification and as per instruction of engineer in charge of following size(6) 450 X 50 X 2.0 mm Thick |
| 303 | Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut & bolts grouted in wall complete.[A] For 4.5 Kg Capacity |
| 304 | Supplying & erecting ABC powder type \"Ceasefire\" type Fire extinguisher as per IS 13849 or 1 Kg capacity with necessary clamp for erection on wall |
| 305 | SITC of Analogue AddressableMulti- Sensorwhich is fully compatible with Analogue Addressable Protocol,having removable high performance chamber with Twin fire LED\"s allow 360 degree viewing, User selectable sensitivity modes 1% to 4.5% obs/m, Incorporate Optical and dual Heat elements, lock mechanism (sensor to base), Electronically addressed, Pulsing/non-pulsing controlled from panel. Approved by LPCB & VdS. (Including Five year free maintenance with guarantee) |
| 306 | SITC of sensor isolator mounting base, includes stainless steel contacts, slim profile - only 8mm,quick connection via square cable clamps, facility for remote indicator, Approved by LPCB (Including Five year free maintenance with guarantee) |
| 307 | SITC of Analogue Addressable Manual Call Point with Integral Short Circuit Isolator, Analogue Addressable Protocol having, Bi-coloured status LED (red for alarm, amber for (short-circuit), Non-frangible element fitted as standard (conforms to EN54), pulsing/non-pulsing can selectable via panel, Electronically addressed, Approved by LPCB. (Including Five year free maintenance with guarantee) |
| 308 | SITC of addressable loop powered Base sounder with integral Beacon, includes 51 user- selectable tones (all tones EN54-3 compatible), variable sound output 50 ~ 98 dB(A) (±2 dB(A)) output at 1 metre, Auto shut down feature prevents noise pollution, \"O\" rated beacon to EN-23, IP21 rated for internal use, sounder and beacon can operate independently, Approved by LPCB (Including Five year free maintenance with guarantee) |
| 309 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000Vratedwithannealedcopperconductorhaving XLPEinsulation,steelwirearmouring&FRLSoutersheath complete as required. |
| 310 | SITC ofActive Repeater Panel to be integrated with Fire Alarm Control Panel,larger display Full colour 800 x 480 LCD with resistive touch screen and automatic back-light dimming and the status of any Fire/Fault of Integrated Fire Alarm Panels,Panel should compliant with EN54-2, EN54-4 and Approved by LPCB (Including Five year free maintenance with guarantee) |
| 311 | SITC of Microprocessor based Net-workable Analogue Addressable Fire Alarm Control Panel. The Panel shall be compliant with EN54-2, EN54-4 and approved by LPCB. The Fire Alarm Control Panel shall have inbuilt 3 loops and expandable upto 4 Loops. The Panel must have large graphic display. The Panel must also have the capability to take Addressable Intelligent Wired and Wireless Devices on same loop. Each loop shall have a capacity of 127 analogue Addressable devices and 127 Base sounders/Base Sounder Beacons. The Panel shall have 240 V AC power supply along with automatic Battery Charger. Approved by LPCB(Including Five year free maintenance with guarantee) |
| 312 | Supply, Installation, Testing and Comissioning of 4MP Varifocal Lens Dome Type Camera, H.265 4MP IR Turret Dome N/W Camera, Manual Varifocal 2.8-12mm, 50M, Micro SD, DC12V/PoE, IP67/IK10, Basic IVA, 4MP resolution (2560 × 1440), True day/night, Digital WDR, 3D DNR, HLC & BLC, Triple streams, Smart codec by ROI, Built in MIC, Cyber Security, Basic intelligent video analytics, Audio In, NDAA Compliance, UL, CE, FCC Certified(Including Five year free maintenance with guarantee) |
| 313 | Supply, Installation, Testing and Comissioning of 4MP Varifocal Lens Bullet Camera, H.265 4MP IR Bullet N/W Camera, Manual Varifocal 2.8-12mm, 50M, Micro SD, DC12V/PoE, IP67/IK10, Basic IVA, 4MP resolution (2560 × 1440), True day/night, Digital WDR, 3D DNR, HLC & BLC, Triple streams, Smart codec by ROI, Cyber Security, Basic intelligent video analytics, NDAA Compliance, UL, CE, FCC Certified(Including Five year free maintenance with guarantee) |
| 314 | Supply, Installation, Testing and Comissioning of 64 Channel Network Video Recorder (NVR), Dual OS design, HDD Hot Swap with RAID support, N+1 hot spare configuration, Support 16CH@2MP, H.265/H.264 Video Compression, HDMI, VGA output, up to 8 SATA interface each with max 10 TB support and 1 eSATA, 16-ch synchronous playback at up to 1080p resolution, Gigabit Ethernet network interfaces, bandwidth 320 mbps, CE FCC, BIS, Operating Temp -10 deg to 50 deg C, USB and serial Interface, RAIDsupported(Including Five year free maintenance with guarantee) |
| 315 | SITC of SCREEN SIZE105.41 cm diagonal (42” INCH), RESOLUTIONFHD (1920*1080), USB INPUT (2.0 SUPPORT)2*Side(USB2.0), HDMI INPUT2*Side(HDMI 1.4), USB DEVICE SUPPORTUSB Supported HDD, HOTEL MODEYes, Basic, BLUETOOTH Yes (Ver. 4.1), WIFI TYPE(STANDARD)802.11a/b/g/n 2.4G 2T2R, Built-in, WIFI BAND TYPE2.4GHz, OS & VERSION INFOAndroid \"P\" - 9.0, MEMORY FLASH8GB EMMC, RAM1.5.0GB , DDR3 2133Mhz. (Including Five year free maintenance with guarantee) |
| 316 | SITC of 48 x 10/100/1000BASE-T ports4 x Gigabit GbE/SFP combo portsAdvanced L2 switching and security featuresL2+ Static RoutingOptional “standard mode” or “surveillance mode” management user interface[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] |
| 317 | Supply, Installation, Testing and commissioning of 6 TB Surveillance Series Hard disk supporting 24X7 operational efficiency |
| 318 | Providing & Erecting Netwrok rack with following capacity with Necessary cooling fan,Cable manager,6A PDU,equipment rack with necessary mounting accessories.(D) 15 U |
| 319 | Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant (Or Eco Friendly Green Gas if any), vibration isolators, with suitable foundation, MS Stand for Unit with necessary paint etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Design should be got approval before execution from engineer in charge) |
| 320 | INDOOR UNIT- CASSETTE TYPE Supply, installation, testing and commissioning of following minimum capacity 4-way radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System (E) 1.67 TR |
| 321 | INDOOR UNIT- CASSETTE TYPE Supply, installation, testing and commissioning of following minimum capacity 4-way radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System.(F) 2.10 TR |
| 322 | INDOOR UNIT- CASSETTE TYPE Supply, installation, testing and commissioning of following minimum capacity 4-way radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System.(G) 2.67 TR |
| 323 | INDOOR UNIT- CASSETTE TYPE Supply, installation, testing and commissioning of following minimum capacity 4-way radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System.(H) 4.17 TR |
| 324 | Supply, installation, testing and commissioning of following minimum capacity 1 way as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System(J) 1.67 TR |
| 325 | Supply, installation, testing and commissioning of following minimum capacity 1 way as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System.(K) 2.1 TR |
| 326 | COPPER REFRIGERANT PIPING Supply, installation, testing and commissioning of following minimum capacity VRV High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with noise level maximum 60 dB @min 400 cfm /dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (B) 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 327 | (C.) 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 328 | (D) 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 329 | (E) 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 330 | (F) 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 331 | (H) 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 332 | (J) 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation |
| 333 | (L) 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation |
| 334 | Control Cables and Wires Supply installation testing commissioning Shielded Shielded Control Cables for VRV System with necessary ISI mark Medium class rigid PVC pipes with necessary accessories with termination in machine and control equipments.. (C) 4C X 1.5 Sq mm Shielded Armoured |
| 335 | Central Control System (A) Cord type remote control with thermostat, LED Display and internal wiring for Cassette, FCU & CSU |
| 336 | Supply, installation Refjoints |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy