Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 11-07-2025 | Notice for Technical Bid Opening of Package VIII | Other | 15-07-2025 |
| 2 | 08-07-2025 | Date Extension upto 15.07.2025 | Date | 15-07-2025 |
| 3 | 07-07-2025 | Notice for Technical Bid Opening of Package VIII under DRIP work. | Other | 08-07-2025 |
| 4 | 19-06-2025 | Notice for Pre Bid Meeting of Package VIII | Other | 08-07-2025 |
| Sl. No. | Item Description |
| 1 | Construction of step concrete wall near intake at Left bank collapsednear intake due to heavy rain of Myntdu Leshka Dam. |
| 2 | Earthwork in excavation for structures: BY MANUAL MEANS inOrdinary Soil |
| 3 | Supplying fitting and placing HYSD bar reinforcement (Fe 415) in Substructure complete as per drawing and Technical Specification clause. |
| 4 | Plain/reinforced cement concrete in sub-structure complete as per drawings and Technical Specification clauses: in P.C.C. grade M20 (1 : 1.5 : 3) Nominal mix: Upto 5 m height. |
| 5 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and Technical Specification clause. |
| 6 | Construction of Retaining wall at Approach to Intake Area including Gate and Grill Railing |
| 7 | Clearance of landslips including removal of spoils to the proper grade and level upto 30 m lead including cleaning of road side drains to the original depth and cleaning the side berms to the proper level and grade complete as per direction of the Engineer: Mechanical means: In Ordinary soil. |
| 8 | Clearance of landslips including removal of spoils to the proper grade and level upto 30 m lead including cleaning of road side drains to the original depth and cleaning the side berms to the proper level and grade complete as per direction of the Engineer: Mechanical means: In Ordinary Rock |
| 9 | Earthwork in excavation for structures as per drawing and Technical Specification Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m dressing of sides and bottom and backfilling in trenches with excavated suitable material: By Manual Means: Without Dewatering: In Ordinary Soil: Upto 3 m depth. |
| 10 | Drilling holes and laying of dowel bars 20 mm to 25 mm into the rocks not less than 75 cm deep and keeping them protruding above the rock for not less than 45 times the diameter of the bar and properly embedding them into the rock by concreting complete as per drawing and Technical Specification: 20 mm dia bars |
| 11 | Supplying, fitting and placing MS bar reinforcement in foundation complete as per drawings and Technical Specification. |
| 12 | Providing and laying reinforced cement concrete in superstructure as per drawing and Technical Specification: In R.C.C. Grade M20, Nominal Mix 1 : 1.5 : 3 Height upto 5 m |
| 13 | P.C.C. M15 concrete ordinary grade (1: 2: 4) leveling course below approach slab complete as per drawing and Technical Specification Clauses: In P.C.C. Grade M15 in proportion 1:2:4 Nominal mix. |
| 14 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and Technical Specification. |
| 15 | Pointing with cement mortar (1: 3) or (1: 4) on brickwork/ masonry/ concrete work as per drawing and Technical Specification: In Cement Mortar 1 : 3 (1-cement : 3 sand) |
| 16 | Providing and fixing in position pipe railing consisting of IS rolled steel joist posts designation IS MB 100 (100 x 75) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and Technical Specification. |
| 17 | Painting on Concrete/Steel Surfaces with Epoxy:Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after thorough cleaning of surfaces to give an even shade as per drawing and Technical Specification. |
| 18 | Construction of step stone masonry wall above staff quarter near view point at Right bank. |
| 19 | Earthwork in excavation by Mechanical means up to a depth of 2 in below the existing ground level tor foundation, trenches Of foundations, footings Of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils: In all kinds of soil (ordinary soiv hard soil/dense soil). |
| 20 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately): In mix 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size). |
| 21 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level: In Cement mortar 1 :6 (1 cement: 6 coarse sand) |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge: In Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc (using steel) |
| 23 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation otc in layers not exceeding 20 cm thick including breaking Of clods, consolidating each layer by ramming and watering, lead up to 50 in and lift up to 1.5 m: With available excavated earth. |
| 24 | Construction of step stone masonry wall below staff quarter near DG set at Right bank of Myntdu Leshka Dam. |
| 25 | Earthwork in excavation by Mechanical means up to a depth of 2m below the existing ground level tor foundation, trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils: In all kinds of soil (ordinary soiv hard soil/dense soil) |
| 26 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately): In mix 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 27 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level: In Cement mortar 1 :6 (1 cement: 6 coarse sand) |
| 28 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge:In Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc (using steel) |
| 29 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation otc in layers not exceeding 20 cm thick including breaking of clods, consolidating each layer by ramming and watering, lead up to 50 in and lift up to 1.5m: With available excavated earth |
| 30 | Pointing on stone work with cement mortar 1 : 3 (1 cement: 3 fine sand): Flushed/ Pluled pointing. |
| 31 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Thermo-Mechanically Treated bars |
| 32 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centerjng, shuttering, finishing and reinforcement- All work up to plinth level: In mix M20 or 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 33 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer: G.I. pipes. |
| 34 | 12 mm cement plaster of mix 1 :4 (1 cement: 4 fine sand) |
| 35 | Construction of step protection wall below DG set at right bank of Myntdu Leshka Dam. |
| 36 | Earthwork in excavation by Mechanical means up to a depth of 2 in below the existing ground level tor foundation, trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils: In all kinds of soil (ordinary soiv hard soil/dense soil) |
| 37 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately): In mix 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 38 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level in Cement mortar 1:6 (1 cement: 6 coarse sand) |
| 39 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge: In Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc (using steel) |
| 40 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation otc in layers not exceeding 20 cm thick including breaking of clods, consolidating each layer by ramming and watering, lead up to 50 in and lift up to 1.5m: With available excavated earth |
| 41 | Reconstruction of grill railing at top of retaining wall constructed at the area of masonry wall collapsed on 20th July 2019 near intake of Myntdu Leshka H.E Project. |
| 42 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Thermo-Mechanically Treated bars |
| 43 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, fillets, columns, pillars, posts and struts etc. above plinth level up to first floor level, excluding cost of centering, shuttering, finishing and reinforcement in M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 44 | Steel work welded in built up sections/framed work including cutting, hoisting, fixing in position and applying a priming coat Of approved steel primer using structural steel eta. as required: ln gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 45 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge:In Columns, Pillars, Piers, Abutments, Posts and struts (using steel). |
| 46 | Construction of protection/step stone masonry wall in the reservoir rim at Left bank of Myntdu Leshka Dam |
| 47 | Earthwork in excavation by Mechanical means up to a depth of 2m below the existing ground level tor foundation, trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils: In all kinds of soil (ordinary soiv hard soil/dense soil) |
| 48 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately): In mix 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 49 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level in Cement mortar 1 :6 (1 cement: 6 coarse sand) |
| 50 | Centering and shuttering including strutting, propping etc. and removal of form for allheights complcte and as directed by Engineer in charge: In Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc (using steel) |
| 51 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Thermo-Mechanically Treated bars. |
| 52 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centerjng, shuttering, finishing and reinforcement- All work up to plinth level: In mix M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 53 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation otc in layers not exceeding 20 cm thick including breaking of clods, consolidating each layer by ramming and watering, lead up to 50 in and lift up to 1.5 m: With available excavated earth. |
| 54 | Providing topping with fresh Concrete M60 grade concrete at Myntdu Leshka Dam top. |
| 55 | Providing and laying of high strength concrete of M60 grade concrete as per specificationproper compaction,curing with all lead and lift,ensuring adequate mix desing and Quality Control for testing as IS standard & technical specification, complete finish items including supply of all materials, Labour, T&P etc. required for proper completion of work. |
| 56 | Repairing of Gallery Drain including Hand Railing and Making V-Notch inside the Gallery. |
| 57 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100 mm up to 200 mm in PICC beams, lintels, columns and slabs to introduce steel bars for sunshades/ balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-in-charge, up to and including 12 mm dia. |
| 58 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Thermo-Mechanically Treated bars |
| 59 | Centering and shuttering includlng strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge: In Columns, Pillars, Piers, Abutments, Posts and struts (using steel). |
| 60 | Providing and fixing hand rail of approved size bywelding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer: G.I. pipes |
| 61 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, fillets, columns, pillars, posts and struts etc. above plinth level up to first floor level, excluding cost of centering, shuttering, finishing and reinforcement: In mix M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 62 | 12 mm cement plaster of mix 1 :4 (1 cement: 4 fine sand) |
| 63 | Applying one coat of water thinnable cement primer of approved brand and manufacture on surfaces: Water thinnable cement primer |
| 64 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation Of surface, etc. complete: On concrete work |
| 65 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 66 | Structural steel work in single section, fixed with or without per kg 117.00 connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Chequer Plate 6mmx240x1200 |
| 67 | Providing and laying cement concrete in retaining walls etc. and all works above plinth level such as pilasters, columns, pillars, posts, struts, buttresses, parapets, coping, plain window sills, fillets, sunken floor etc,, up to first floor level, excluding the cost of centering, shuttering and finishing: In mix 1 :1.5 :3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 68 | Providing and fixing in position collapsible steel shutters with vertical channels 20xl0x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia. steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 69 | Providing safety railing and drilling of drain holes at horizontal girder including welding works in the bottom most of radial gate\"s arm. |
| 70 | Providing and fixing hand rail of approved size bywelding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approvedsteel primer: G.I. pipes |
| 71 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, includingscaffolding:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 72 | Providing Drain holes in Sluice Radial Gates Gate 50mm by Gas Cutting in every Seal Assembly. |
| 73 | MS Plates/Steel section (Gr.A) for E.P. Filling back the Cutting area in Sluice Radial Gate Arms: MS Plate 35mm. |
| 74 | Providing Approach Stairway/Walkway to reach Bucket Lip |
| 75 | Earthwork in excavation by manual means up to a depth of 2m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septictank etc. including bailing out water where necessary and removal Of surplus earth with all lead and lifts as directed and specified for the following classification of soils: In All kinds of soil (ordinary soil/ hard soil/ dense soil) |
| 76 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level in Cement mortar 1 :6 (1 cement: 6 coarse sand) |
| 77 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately) in mix 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 78 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100 mm up to 200 mm in PICC beams, lintels, columns and slabs to introduce steel bars for sunshades/ balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-in-charge Up to and including 12 mm dia. |
| 79 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Thermo-Mechanically Treated bars. |
| 80 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge in Lintels, beams, plinth beams, girders, bressumers and cantilevers (using steel). |
| 81 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge in Columns, Pillars, Piers, Abutments, Posts and struts (usingsteel). |
| 82 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge in Stairs/ spiral staircase, (excluding landings) (using timber) |
| 83 | Providing and fixing hand rail of approved size bywelding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer: With M.S. tube. |
| 84 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost Of centerjng, shuttering, finishing and reinforcement- All work up to plinth level: In mix M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 85 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, fillets, columns, pillars, posts and struts etc. above plinth level up to first floor level, excluding cost of centering, shuttering, finishing and reinforcement: In mix M20 or 1 :11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 86 | 12 mm cement plaster of mix 1 :4 (1 cement: 4 fine sand) |
| 87 | Applying one coat of water thinnable cement primer of approved brand and manufacture on surfaces: Water thinnable cement primer |
| 88 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation Of surface, etc. complete: On concrete work. |
| 89 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding: Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 90 | Construction of roof covering of Gantry crane including walling at Intake gate of Myntdu Leshka Stage-I. |
| 91 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 92 | Providing corrugated G.S. or galvanised iron sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in Horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever require 1.00 mm thick with zinc coating not less than 275 gm/m² |
| 93 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m² |
| 94 | Painting on G.S Sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: In New work (Two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution. |
| 95 | Making platform and steps required to facilitate the people to reach the spillway crest level. |
| 96 | Structural steel work in single section, fixed with or without per kg 117.00 connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: G.I.Pipes |
| 97 | Providing and fixing hand rail of approved size bywelding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer: M.S. tube |
| 98 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation Of surface, etc. complete: On steel work |
| 99 | Construction of Drinking Water Source for Myntdu Leshka Dam at Myntdu Leshka Dam Site |
| 100 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m: In All kinds of soil. |
| 101 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: In All kinds of soil. |
| 102 | Providing and laying cement concrete in rctaining walls ctc and all works above plinth level such as pilasters, columns,pillars, posts, struts, buttresses, parapets, coping, plaln window sills, fillets, sunken flcor etc,, up to first floor level, excluding the cost Of centering, shuttering and finishing: In mix 1 :2:4 (1 Cemem: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) |
| 103 | Providing and laying cement concrete in rctaining walls ctc and all works above plinth level such as pilasters, columns, pillars, posts, ruts,buttresses, parapets, coping, plaln window sills, fillets, sunken flcor etc,, up to first floor level, excluding the cost Of centering, shuttering and finishing: In mix 1:1.5:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 104 | Supplying, fitting and fixing in position einforcement bars up to lst floor level, Conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): With Mild steel and Medium Tensile steel bars. |
| 105 | Centering and shuttering including strutting, propplng etc. and removal of form for all heights complcte and asdirected by Engineer in charge: In Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc (using steel). |
| 106 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : In Mix M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 107 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement. |
| 108 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement: 20 mm cement plaster. |
| 109 | Providing and fixing G.I. pipes complcte with G.I. fittings including trenching and refilling etc.: External work: 40 mm diameter nominal bore |
| 110 | Providing and fixing G.I. pipes complcte with G.I. fittings including trenching and refilling etc.: External work: 50 mm diameter nominal bore |
| 111 | Providing and fixing G.I. pipes complcte with G.I. fittings including trenching and refilling etc.: External work: 80 mm diameter nominal bore |
| 112 | Construction of Drinking Water Storage Tank and Pipe Line From Storage Tank to Dam Control Room. |
| 113 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m: In all kind of soil. |
| 114 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. In all kind of soil. |
| 115 | Providing and laying cement concrete in rctaining walls ctc and all works above plinth level such as pilasters, columns,pillars, posts, struts, buttresses, parapets, coping, plaln window sills, fillets, sunken flcor etc,, up to first floor level, excluding the cost Of centering, shuttering and finishing. In mix 1:2:4 (1 Cemem: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size). |
| 116 | Supplying, fitting and fixing in position reinforcement bars upto lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): With Mild steel and Medium Tensile steel bars. |
| 117 | Centering and shuttering including struttlng, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: In Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc (using steel) |
| 118 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : In mix M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 119 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: In mix 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) : |
| 120 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement: In 20 mm cement plaster. |
| 121 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.: With 50 mm dia nominal bore |
| 122 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.: With 32 mm dia nominal bore. |
| 123 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore |
| 124 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm nominal bore |
| 125 | Providing and fixing gun metal gate valve with C.I, wheel of approved qilality (screwed end): 50 mm nominal bore |
| 126 | Dismantling of Existing Stone Masonry Guard Wall and Providing New Pipe Railing at Right Bank of Myntdu Leshka Dam. |
| 127 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 128 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 129 | Providing and laying cement concrete in rctaining walls ctc and all works above plinth level such as pilasters, columns, pillars, posts, struts, buttresses, parapets, coping, plaln window sills, fillets, sunken flcor etc,, up to first floor level, excluding the cost Of centering, shuttering and finishing1:2:4 (1 Cemem: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) |
| 130 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports,chairs,spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Thermo-Mechanically Treated bars |
| 131 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports,chairs,spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required)Mild steel and Medium Tensile steel bars |
| 132 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and asFoundations, footings, bases of columns, etc. for mass Columns, Pillars, Piers, Abutments, Posts and struts (using steel). |
| 133 | Centering and shuttering including strutting, propping etc: In Columns, Pillars, Piers, Abutments, Posts and struts (using steel). |
| 134 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : In mix M20 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 135 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer: G.I. pipes |
| 136 | 12 mm cement plaster of mix : .1 cement: 4 fine sand |
| 137 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer |
| 138 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.84 ltr/10 sqm). |
| 139 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. Complete: On steel work. |
| 140 | Repairing of existing side drain and masonry wall at Right bank of Myntdu Leshka Dam. |
| 141 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m in All kinds of soil. |
| 142 | Chipping of unsound/ weak concrete material from slabs, beams,columns ctc. with manual Chisel and/ or by standard power driven percussion type or of approved make including taperingof all edges, making square shoulders of cavities including cleaningthe exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead andliftsallcomplete as per direction of Engineer-in-charge: 25 mm average thickness |
| 143 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of F}CC as per specifications and direction of Engineer-ln-charge complete in all respect: SBF3 Polymer (@ 100/a of cement weight) modified cementitiousbond [email protected] per sqm of surface area mixed with specified proportion of approved polymer. |
| 144 | Centering and shuttering including strutting, proppingetc. and removal of form for all heights complcte and asdirected by Engineer in charge: In Columns, Pillars, Piers, Abutments, Posts and struts (using steel). |
| 145 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete: Stone soling-100 mm |
| 146 | Providing and laying cement concrete in rctaining walls ctc and all works above plinth level such as pilasters, columns,pillars, posts, struts, buttresses, parapets, coping, plaln window sills, fillets, sunken flcor etc,, up to first floor level, excluding the cost of centering, shuttering and finishing in Mix 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) |
| 147 | Providing and laying cement concrete in rctaining walls ctc and all works above plinth level such as pilasters, columns,pillars, posts, struts, buttresses, parapets, coping, plaln window sills, fillets, sunken flcor etc,, up to first floor level, excluding the cost of centering, shuttering and finishing in Mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) |
| 148 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level: In Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 149 | 20 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) |
| 150 | Painting of water level pillar at both Left and Right bank Pillar of Myntdu Leshka Dam. |
| 151 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 152 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete: On concrete work |
| 153 | Printing New Letters and Figures of Any Shade Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per Technical Specification. English and Roman Hyphens, commas and the like not to be measured and paid for. Detail for 100 letters of 100 cm height i.e 1.60 m or 1600 cm: In Right Bank (20cm Height) |
| 154 | Printing New Letters and Figures of Any Shade Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per Technical Specification. English and Roman Hyphens, commas and the like not to be measured and paid for. Detail for 100 letters of 100 cm height i.e 1.60 m or 1600 cm: Dots & Arrow (5cm Height) |
| 155 | ProvidingPipe Line Water for Water Supply from Source to Staff Quarter and Control Room at Myntdu Leshka Dam |
| 156 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: In All kinds of soil. |
| 157 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge: In Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc (using steel) |
| 158 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): With Mild steel and Medium Tensile steel bars. |
| 159 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: In mix 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 160 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement: In 20 mm cement plaster. |
| 161 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.: 25 mm dia nominal bore. |
| 162 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.: 32 mm dia nominal bore. |
| 163 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.: 50 mm dia nominal bore. |
| 164 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.: 90 mm dia nominal bore. |
| 165 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore. |
| 166 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore |
| 167 | Providing and fixing brass stop cock of approved quality : 15 mm nominal bore |
| 168 | Providing and fixing gun metal gate valve with C.I. wheelof approved quality (screwed end) :80 mm nominal bore |
| 169 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 25 mm nominal bore |
| 170 | Providing and fixing Sign board/name plates showing the salient feature of Myntdu Leshka Dam stage-I |
| 171 | Printing New Letters and Figures of any Shade Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per Technical Specification Clause : English and Roman: Hyphens, commas and the like not to be measured and paid for. Detail for 100 letters of 100 cm height i.e 1.60 m or 1600 cm. |
| 172 | Supported on mild steel angle iron post 75 mm x 75 mm x 6 mm:Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC: 67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over Aluminium Sheeting 1.5 mm thick supported on a Mild Steel Angle Post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawing and Technical Specification |
| 173 | Steel work welded in built up sections/framed work including cutting, hoisting, fixing in position and applying a priming coat Of approved steel primer using structural steel eta. as required: .ln gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.ISA 7575 : 75*75*6mm |
| 174 | Earthwork in excavation by manual means up to a depth of 2m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils: In All kinds of soil (ordinary soil/ hard soil/ dense soil) |
| 175 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately): In mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) |
| 176 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Thermo-Mechanically Treated bars |
| 177 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centerjng, shuttering, finishing and reinforcement- All work up to plinth level: In mix M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 178 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge.In Columns, Pillars, Piers, Abutments, Posts and struts (using steel). |
| 179 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation otc in layers not exceeding 20 cm thick including breaking of clods, consolidating each layer by ramming and watering, lead up to 50 in and lift up to 1.5m: With available excavated earth |
| 180 | 12 mm cement plaster of mix: 1 :4 (1 cement: 4 fine sand) |
| 181 | Turfing on both sides of the downstream. |
| 182 | Downstream Turfing:-Sodding the slopes with grass seeds including raising and preparing groung spreading a layer of good earth upto a depth of 300mm (average) wherever required (cost of earth included) watering rolling etc.complete as per direction within a initial leadof 50 meters and lift of 1.5 meters (for additional leads and lifts, payment are to be made as per the related earth work items). |
| 183 | Renovation of Inspection Bungalow of Myntdu Leshka H.E. Project at Thamar. |
| 184 | Renovation of Doors, Windows and Ventilators at Ground Floor Level of Inspection Bungalow Thamar. |
| 185 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, hold fasts etc complete and stacking within 50 m lead of area beyond 3 sqm |
| 186 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make contorming to IS:733 and IS:1285, fixing with dash fasteners of required diameter and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitredand jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P.brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, and panelling to be paid for separately): For shutters of doors and windows and ventilators including providing hinges/pivots and making provision for fixing of fitting whereever required including the caused EPDM rubber/neoprint gasket required (fitting shall be paid seperately). Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade AC 15). |
| 187 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. |
| 188 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes. |
| 189 | Finishing walls with toxtured exterior paint of required shade, including scaffolding: In Old work two or more coats on existing cement paint surface applied @ 3.28 ltr/10 sqm. |
| 190 | Providing and applying Plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smcoth complete |
| 191 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding: Two or more coats applied on walls @ 1.25 Itr/10 sqm over sqm 128.00 and including one coat of Special primer applied @ 0.75 ltr/10 Sqm. |
| 192 | Renovation of Sanitary Fittings at Ground Floor Level and Water Supply Pipe Lines at Inspection Bungalow Thamar. |
| 193 | Providing and fixing CP Brass Single lever telephonic wall mixer quality & make as approved by Engineer - In - Charge. |
| 194 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: 100 mm diameter. |
| 195 | Providing and fixing wash basin with C.I. brackets, 15 mm dia. CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China Wash basin size 550x400 mm with a 15mm CP Brass single hole basin mixer 15 mm nominal bore. |
| 196 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings: |
| 197 | Providing and Fixing P.V.C waste pipe for sink and wash basin including P.V.C. wastefitting complete: Flexible Pipe:32 mm dia and 40 mm dia |
| 198 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. |
| 199 | Providing and Fixing plain of required degree with cast iron S&S as per IS: 1729 : 100 mm dia |
| 200 | Providing and fixing brass bib cock of approved quality: 20 mm nominal bore, 120 mm long, weighing not less than 198 gins. |
| 201 | Providing and fixing toilet paper holder : C.P. Brass |
| 202 | Providing and fixing PTMT towel ring Tapezoidal shape 215 mm long, 200 mm wide with minimilm distances of 37 mm from wall face with concealed fittings arrangemem Of approved quality and colour, weighing not less than 88 gins. |
| 203 | Providing and fixing PTMT towel rail complete with brackets fixed to wcoden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour600mm |
| 204 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall Of standard shape with bracket of the same materials with snap fittings of approved qualfty and colour, weighing not less than 105 gins. |
| 205 | Providing and fixing 600×450 mm bevelled edge mirror of superior glass (or approve quality) complete with 6mm thick hard board ground like wooden cleats with C.P. Brass screws and washer complete. |
| 206 | Providing and fixing 600×120×5 mm glass shelf with edges round off supported and nodised alluminium anngle frame C.P. brass bracket Guard rail complete fixed with 40mm long screws rawl plug ext complete. |
| 207 | Providing and fixing door piece, insertion rLibber washer 3mm thick, bolts & nuts complete with sand cast iron S&S as per IS:1729: |
| 208 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 in spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc: 20 mm nominal outer diameter pipes. |
| 209 | Providing Cement Concrete Topping including Water Proofing Course at Roof Level and Repairs to Plaster in Parapet Wall of Inspection Bungalow Thamar. |
| 210 | Hacking of CC flooring including cleaning for Surface etc. complete as per direction of the Engineer-in-Charge. |
| 211 | Dismantling 15 to 40 mm dia. G.I, pipe including slacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge: Internal Work- Exposed on wall |
| 212 | 65 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 15 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture\"s specifications. This includes cost of cement slurry, complete. |
| 213 | Repairs to plaster ot thickness 12 mm to 20 mm in patches Of area 2.5 sqm and under, including cutting the patch in proper shape, ral |
| 214 | Renovation of Electrification at Ground Floor Level of Inspection Bungalow Thamar including Street Lighting in IB compound. |
| 215 | Supplying fitting fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED bulb surface or wall mounted with all necessary accessories: Bulb - 40 Watt. |
| 216 | Supplying fitting fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED bulb surface or wall mounted with all necessary accessories: Candle LED Bulb: 5 W |
| 217 | Supplying fitting fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED bulb surface or wall mounted with all necessary accessories: Filament LED Bulb: 8 W |
| 218 | Supplying fitting fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED bulb surface or wall mounted with all necessary accessories: Emergency LED Bulb:9 W |
| 219 | Supplying fitting, fixing of LED RETROFIT LAMPS surface or wall mounted with all necessary accessories: Regal battern for LED Tube Light (Universal batten for T-5 & T-8 Lamps: 8 upto 2 × 22W |
| 220 | Supplying fitting, fixing of LED RETROFIT LAMPS surface or wall mounted with all necessary accessories: Crystal Glass LED Tube Light (Double Size Connection) : 18 W |
| 221 | Supplying fitting and fixing LED down light surface or wall mounted with all necessary accesories: Round Slim fit low profile down light are engineered to delivered superior light out put and uniformity using the latest aged - lit LED technology: 15 W Ceiling cut out Ø 180 mmheight 16 mm .Round shape. |
| 222 | Supplying fitting and fixing of Wall/Table Fan with all necessary attachments and accessories as required: 400mm Wall Fan |
| 223 | Supplying fitting and fixing exhaust fan double bearing self duplicating type single phase 50Htz 250 V AC Operated complete with supporting frame fan blade nuts and bolts and others petty as accesories required: Domestic exhaust Fan:Metal Exhaust Fan 225 mm |
| 224 | Supplying fitting and fixing waterheater (Geyser) of 1.5 Kw/with pressure value including all necessary accesirie required: 35 Litres Capacity |
| 225 | Aesthetically designed decorative hot dipped galvanized mild steel step pole with grey powder finished, plasma cut and duly chamfeared opening window of 300 × 110 mm for terminal connection and mounting accessories window cover is fitted with allen screw to the pole: 4 metre poles |
| 226 | Drawing of 3 phase main line with DGSD approved VIR or PVC 660 volt grade copper conducter in casing caping with all accessories: With 4 x 10 mm2 Copper conductor. |
| 227 | Supplying and fixing load kontaket miniature circuit Brakes RX3: Single pole MCB: 6 - 32 Amp. |
| 228 | Supplying and fixing load kontaket miniature circuit Brakes RX3: Tripple pole MCB:6 - 32 Amp |
| 229 | Supplying fitting and fixing of RX3 Isolator (35 sq. mm cage terminals with safety shutters): Double Pole: 40 Amp |
| 230 | Supplying fitting and fixing of Distribution board ETPN DB\"s for MCB, Isolator, RCCB and RCBO: IP 30 # 1k 08 Mouble Pole |
| 231 | Supplying fitting and fixing earthing with G.I. pipe of 200cm lay 40\" dia icluding all accessories & providing masonry enclosure with cover plate having locking arrangement etc with charcoal salt complete as required: G.I. Pipe |
| 232 | Supplying fitting and fixing earthing with copper Plate 600 × 600 mm × 6mm thick including accessories & providing masonry enclosure with cover plate having locking arrangement & watering pipe etc with charcoal, salt etc complete as required: Copper earth plate electrode |
| 233 | Construction of Security Outpost at the Entrance to Inspection Bungalow Thamar. |
| 234 | Earthwork in excavation by manual means up to a depth of 2m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils: In All kinds of soil (ordinary soil/ hard soil/ dense soil) |
| 235 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete: Stone soling-100mm thick |
| 236 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately): In mix 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) |
| 237 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C.work/ a.a. walling including straightening, cleaning, cuttingand bending to proper shapes and length as per details,supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): High Yield Strength Deformed bars or Tor Bars |
| 238 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: In Foundations, footings, bases of columns, etc. for mass concrete (using steel) |
| 239 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost Of centerjng, shuttering, finishing and reinforcement- All work up to plinth level: In mix M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 240 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level with: In Cement mortar 1 : 6 (1 cement: 6 coarse sand) |
| 241 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation otc in layers not exceeding 20 cm thick including breaking Of clods, consolidating each layer by ramming and watering, lead up to 50 in and lift up to 1.5 m: With borrowed earth/stone dust carriage up to 5 KM |
| 242 | 65 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 15 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture\"s specifications. This includes cost of cement slurry, complete. |
| 243 | Brick work in cement mortar with first class brick in superstructure above plinth level up to first floor level in all shapes and sizes: In Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 244 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make contorming to IS :733 and IS:1285, fixing with dash fasteners of required diameter and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P.brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, and panelling to be paid for separately): For fixed portion: Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade AC 15). |
| 245 | 12 mm cement plaster of mix 1 :4 (1 cement: 4 fine sand) |
| 246 | Renovation of Boundary Fencing for Inspection Bungalow at Thamar. |
| 247 | Applying priming coat: With ready mked pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)/ with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. |
| 248 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete: On steel work. |
| 249 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete: On concrete work. |
| 250 | Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per loo in (minimum), between the two posts fitted and fixed with G.I. staples, turn bucl(les etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used: With G.I. barbed wire |
| 251 | Laying G.I pipe from Krem Rymbai Drinking Water source to Inspection Bungalow Thamar and Nohkum colony main storage tank including supporting pillars |
| 252 | Laying G.I. pipes in trenches including carriage of pipes from stock yard to the site within a distance of 8km. Except socket joints, all fittings required for the work will be paid extra as per current schedule of rates. Trenching and earth filling is also exclusive and shall be paid extra. (Medium Quality): 25 mm dia |
| 253 | Laying G.I. pipes in trenches including carriage of pipes from stock yard to the site within a distance of 8km. Except socket joints, all fittings required for the work will be paid extra as per current schedule of rates. Trenching and earth filling is also exclusive and shall be paid extra. (Medium Quality): 40 mm dia |
| 254 | Laying G.I. pipes in trenches including carriage of pipes from stock yard to the site within a distance of 8km. Except socket joints, all fittings required for the work will be paid extra as per current schedule of rates. Trenching and earth filling is also exclusive and shall be paid extra. (Medium Quality): 50 mm dia |
| 255 | Supplying, fitting and fixing G.I. Flange as per the approved quality of the department including making hole, cuting and threading the pipe including supplying bolts, nuts and rubber washers and and carriage of materials within 8km complete as directed (Medium Quality):40 mm dia nominal bore |
| 256 | Supplying, fitting and fixing G.I. Union Socket as per the approved quality of the department including jointing materials and carriage of materials within 8km complete as directed (Medium Quality):40mm dia nominal bore |
| 257 | Supplying, fitting and fixing Gun Metal Non - Return Valveincluding jointing materials and carriage of materials within 8km complete as directed :40 mm dia nominal bore |
| 258 | Supplying, fitting and fixing G. I Reducing Tee mplete as directed.as per the approved quality of the department including jointing materials and carriage of materials within 8km complete as directed (Medium Quality).: 40 × 15 mm dia |
| 259 | Supplying, fitting and fixing G. I Reducing Tee mplete as directed.as per the approved quality of the department including jointing materials and carriage of materials within 8km complete as directed (Medium Quality).: 50 × 40 mm dia |
| 260 | Supplying, fitting and fixing G. I Reducing Tee mplete as directed.as per the approved quality of the department including jointing materials and carriage of materials within 8km complete as directed (Medium Quality).:40 × 25 mm dia |
| 261 | Supplying, fitting and fixing G.I. Equal Tee as per the approved quality of the department including jointing materials and carriage of materials within 8km complete as directed (Medium Quality):40mm dia |
| 262 | Supplying, fitting and fixing G.I. Equal Tee as per the approved quality of the department including jointing materials and carriage of materials within 8km complete as directed (Medium Quality):25mm dia |
| 263 | Supplying, fitting and fixing G.I. Elbow as per approved quality of the department including jointing materials and carriage of 8km complete as directed (Medium Quality):25mm dia |
| 264 | Supplying, fitting and fixing G.I. Plug as per the approved quality of the department including jointing materials and carriage of 8km complete as directed:40mm dia |
| 265 | Supplying, fitting and fixing G.I. Bend as per the approved quality of the department including jointing materials and carriage of 8km complete as directed (Medium Quality):40mm dia |
| 266 | Supplying, fitting and fixing G.I. Bend as per the approved quality of the department including jointing materials and carriage of 8km complete as directed (Medium Quality): 50mm dia |
| 267 | Supplying, fitting and fixing ISI markedgun metal full way wheel valve(Superior Quality) including jointing materials and carriage of 8km complete as directed: 25mm dia |
| 268 | Supplying, fitting and fixing ISI markedgun metal full way wheel valve(Superior Quality) including jointing materials and carriage of 8km complete as directed: 40mm dia |
| 269 | Supplying, fitting and fixing ISI markedgun metal full way wheel valve(Superior Quality) including jointing materials and carriage of 8km complete as directed: 50mm dia |
| 270 | Providing RCC supporting pillar placed 2.5m apart with 45cm×45cm×10cm P.C.C. based in proportion 1:3 over which 45cm×45cm×15cm. Footing prop 1:2:4 and 15cm×15cm pillar prop 1:2:4 reinforced with 8mm dia T.S rod @ 15cm c/c both ways at bottom and 4nos of vertical 12mm M.S. rod with 6mm dia MS stirrups @15mm c/c on top including 12mm thick plastering in proportion 1:3 with foundation earth cutting shuttering curing etc all complete as per direction (for 15mm dia to 65mm dia pipes): Up to 1m height of pillar: Materials procured by Contractor |
| 271 | Providing RCC supporting pillar placed 2.5m apart with 45cm×45cm×10cm P.C.C. based in proportion 1:3 over which 45cm×45cm×15cm. Footing prop 1:2:4 and 15cm×15cm pillar prop 1:2:4 reinforced with 8mm dia T.S rod @ 15cm c/c both ways at bottom and 4nos of vertical 12mm M.S. rod with 6mm dia MS stirrups @15mm c/c on top including 12mm thick plastering in prop 1:3 with foundation earth cutting shuttering curing etc all complete as per direction (for 15mm dia to 65mm dia pipes): Subsequent height of pillar : Materials procured by Contractor |
| 272 | Construction of R.C.C Building for Chowkidar cum Drivers room at Inspection Bungalow Thamar |
| 273 | Earthwork in excavation by manual means up to a depth of 2m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils: In All kinds of soil (ordinary soil/ hard soil/ dense soil) |
| 274 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete: Stone soling: l00 mm thick. |
| 275 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured andpaid separately): In mix 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 276 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C.work/ a.a. walling including straightening, cleaning, cuttingand bending to proper shapes and length as per details,supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): High Yield Strength Deformed bars or Tor Bars |
| 277 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: In Foundations, footings, bases of columns, etc. for mass concrete (using steel) |
| 278 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: In Lintels, beams, plinth beams, girders, bressumers andcantilevers (using steel). |
| 279 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: In Slabs, roofs, landings, balconies and access platform, shelves (using steel) |
| 280 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge. Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick: In Suspended floors, roofs, landings, balconies and access platform with water proof ply 1 2 mm thick |
| 281 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost Of centerjng, shuttering, finishing and reinforcement- All work up to plinth level: In mix M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 282 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately): In Mix 1 :2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) |
| 283 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour:600mm |
| 284 | Providing and Fixing plain bend of required degree with cast iron S&S as per IS: 1729 : 100 mm dia |
| 285 | Constructing soak pit 1.20xl.20xl.20 in filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. |
| 286 | Reinforced cement concrete work in beams, slabs, roofs having slope up to 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to first flcor level, excluding the cost of centerlng, shuttering, finishing and reinforcement in M20 or 1 :l.1/2:3 (1 cement: 1.l/2 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 287 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level with: In mix cement mortar 1 : 6 (1 cement: 6 coarse sand) |
| 288 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation otc in layers not exceeding 20 cm thick including breaking Of clods, consolidating each layer by ramming and watering, lead up to 50 in and lift up to 1.5 m:With borrowed earth/stone dust carriage up to 5 KM |
| 289 | 65 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 15 mm thick cement hardener consisting of mix 1 : 2 (1 cement hardener mix: 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture\"s specifications. This includes cost of cement slurry, complete |
| 290 | Brick work with common burnt clay modular lst class bricks in foundation and in plinth: In Cement mortar 1 :4 (1 cement : 4 coarse sand) |
| 291 | Brick work in cement mortar with first class brick in superstructure above plinth level up to first floor level in all shapes and sizes: In Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 292 | Providing wood work in frames Of doors, windows, clerestory windows and other frames, wrought trained and fixed in position with hold fast lugs or with dash fasteners of required diameter & length with lst class Local wood like Pooma/ Hollock/ Gamari/ and the like. |
| 293 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)c) With lst class Local wood Pooma/ Hollock/ Gamari/ and the like: 35 mm thick shutter. |
| 294 | Providing and fixing factory made lsl marked steel glazed doors, windows and ventilators, side/ top/ center hung, with beading and all members such as F7D, F4B, Kll 8 and K12 8 etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other f\"ngs, complete all a§ per approved design, (sectional weight of only steel members shall be measured tor payment) |
| 295 | 12 mm cement plaster of mix 1 :4 (1 cement: 4 fine sand) |
| 296 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smoot |
| 297 | Providing and fixing IS:12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete: Size 125x64x2.50 mm |
| 298 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete: Size 250xl0 mm |
| 299 | Providing and fixing bright finished brass handles with screws etc. complete: Size 125 mm |
| 300 | Providing and fixing bright finished brass loo mm mortise latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 301 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with:4.O mm thick glass panes |
| 302 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per ls:13983 with C.I. brackets and stainless steel plug 40 mm, including painting Of fittings and brackets, cutting and making gcod the walls wherever required: Kitchen sink with drain board: 510xl040 mm bowl depth 178 mm. |
| 303 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS:7231, with all fi\"ngs and fixtures complete. including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C, pan of size 580x440 mm with integral type foci rests |
| 304 | Providing and fixing 600×450 mm bevelled edge mirror of superior glass (or approve quality) complete with 6mm thick hard board ground like wooden cleats with C.P. Brass screws and washer complete. |
| 305 | Providing and fixing toilet paper holder : C.P. Brass |
| 306 | Providing and fixing PTMT towel rail complete with brackets fixed to wcoden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour: 600mm |
| 307 | Providing and Fixing plain bend of required degree with cast iron S&S as per IS: 1729 :100 mm dia |
| 308 | Providing and Fixing plain bend of required degree with cast iron S&S as per IS: 1729 : 75 mm dia |
| 309 | Providing and fixing single unequal plain junction of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete with sand cast iron S&S as per IS: 1729/ IS: 3989. 100 × 100 × 75 mm |
| 310 | Providing and fixing single unequal plain junction of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete with sand cast iron S&S as per IS: 1729/ IS: 3989. 100 × 100 × 75 mm |
| 311 | Applying one coat of water thinnable cement primer of approved brand and manufacture on surface: Water thinnable cement primer |
| 312 | Wall painting with acrylic emulsion pain of approved brand and manufacture to give an even shade: On New work (two or more coats) |
| 313 | Wall painting with acrylic emulsion palnt, having VOC (Volatile Organic Compound) content less than 50 grams/ltr, Of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. New work (two) |
| 314 | Applying priming coat:With ready miked pink or Grey primer Of approved brand and manufacture on wood work (hard and soft wood)/ with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. With ready mked pink or Grey primer Of approved brand and manufacture on wood work (hard and soft wood)/ with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood |
| 315 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding: Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 316 | Painting wood work with Deluxe Mufti Surface Paint of required shade. Two or moi.e coats applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 Itr/10 sqm Of approved brand and manufacture |
| 317 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ls:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 318 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 in spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.: 20 mm nominal outer diameter pipes |
| 319 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Change. External work 25 mm nominal outer diameter pipe |
| 320 | Providing and fixing gun metal gate valve with C.I, wheel Of approved qilality (screwed end) External work: 25 mm nominal bor |
| 321 | Providing and fixing brass bib cock of approved quality15 mm nominal bore |
| 322 | Providing and fixing C.P. brass bib cock of approved quality conforming to ls:893115 mm nominal bore |
| 323 | Providing and fixing C.P. brass stop cock (concealed) Of standard design and of approved make conforming to IS:893115 mm nominal bore |
| 324 | Internal wiring:Wiring in looping system with Copper/Alluminium PVC cable 250/440 volt grade of size 1.5sqm of approved quality using PVC casing capping including 5 Ampers switch Indian best quality ceiling rose etc capable toa highest point: To a long point wiring upto 10mts. |
| 325 | Wiring in looping system with Copper/Alluminium PVC cable 250/440 volt grade of size 1.5sqm of approved quality using PVC casing capping including 5 Ampers switch Indian best quality ceiling rose etc capable toa highest point: To a medium point wiring upto 6mts. |
| 326 | Wiring in looping system with Copper/Alluminium PVC cable 250/440 volt grade of size 1.5sqm of approved quality using PVC casing capping including 5 Ampers switch Indian best quality ceiling rose etc capable toa highest point: To a short point wiring upto 3mts. |
| 327 | Wiring in looping system with Copper/Alluminium PVC cable 250/440 volt grade of size 2x2.5sqmm of approved quality using PVC casing capping including 5 Ampers switch Indian best quality ceiling rose etc capable toa highest point, with continineous earth wire complete to a light plug point when fixed on the same board: Short point wiring upto 3mts. |
| 328 | Wiringin looping system with copper PVC cable 250/440 volt grade of size 2x4sqmm of approved quality using PVC casing capping including 15 amperes switch/socket Indian best quality complete to Power Plug point with continous earth wire complete: Long point wiring upto 10 mts. |
| 329 | Wiringin looping system with copper PVC cable 250/440 volt grade of size 2x4sqmm of approved quality using PVC casing capping including 15 amperes switch/socket Indian best quality complete to Power Plug point with continous earth wire complete: Medium point wiring upto 6 mts. |
| 330 | Drawing main and sub-main line with DGSD approved VIR or PVC 250/440 volt grade copper conducter in PVC casing caping complete with all accessories: With 2 × 2 .50 mm2 Copper conductor. |
| 331 | Drawing main and sub-main line with DGSD approved VIR or PVC 250/440 volt grade copper conducter in PVC casing caping complete with all accessories: With 2 × 4 mm² Copper conductor. |
| 332 | Drawing main and sub-main line with DGSD approved VIR or PVC 250/440 volt grade copper conducter in PVC casing caping complete with all accessories: With 2 × 6 mm² Copper conductor. |
| 333 | Supplying fitting fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED bulb surface or wall mounted with all necessary accessories: Bulb 18 W |
| 334 | Supplying fitting, fixing of LED RETROFIT LAMPS surface or wall mounted with all necessary accessories: Regal batten for LED tube (universal) batten for T5 and T8 Lamp) 8 upto 1 × 22 W |
| 335 | Supplying and fixing load kontaket miniature circuit Brakes RX3.6-32Amp single pole MCB. |
| 336 | Supplying with fitting complete 250V ICSP&On Main Switch 32Amp. |
| 337 | Supplying fitting and fixing of RX3 Isolator (35 sq. mm cage terminals with safety shutters) 40 Amp: |
| 338 | Supplying fitting and fixing of RX3 Isolator (35 sq. mm cage terminals with safety shutters) 63 Amp: |
| 339 | Supplying fitting and fixing of Distribution board ETPN DB\"s for MCB, Isolator, RCCB and RCBO4 Way 8 +12 Module: IP 30 # 1k 08 Mouble Pole |
| 340 | Supplying fitting and fixing of Distribution board ETPN DB\"s for MCB, Isolator, RCCB and RCBO8 Way 8 +24 Module: IP 30 # 1k 08 Mouble Pole |
| 341 | Supplying fitting and fixing earthing with G.I. pipe of 200cm lay 40\" dia icluding all accessories & providing masonry enclosure with cover plate having locking arrangement etc with charcoal salt complete as required: G.I. Pipe |
| 342 | Supplying fitting and fixing earthing with copper Plate 600 × 600 mm × 6mm thick including accessories & providing masonry enclosure with cover plate having locking arrangement & watering pipe etc with charcoal, salt etc. complete as required: Copper earth plate electrode |
| 343 | Supplying fitting and fixing of 50W Solar Street Light, 15 W 2 in 1 Luminary (Lithium ION Battery), 50 W Solar Panel GI Pole (20 feet) Galvanised complete with Structure Automatic Dusk to Dawn) complete as directed by Engineer-in-chage. |
| 344 | Construction of Three Storeyed R.C.C. Building Type VI at colony area of Myntdu Leshka |
| 345 | Earthwork in excavation by Mechanical means up to a depth of 2m below the existing ground level tor foundation, trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils: In All kinds of soil (ordinary soil/hard soil/dense soil). |
| 346 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete: Stone soling 100mm |
| 347 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete: Stone soling 150mm |
| 348 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: In Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 349 | Half brick masonry with common burnt clay (non modular) lst class bricks in superstructure above plinth level up to first floor level. In Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 350 | Extra over item above \"Half brick masonry with common burnt clay (non modular) lst class bricks in superstructure above plinth level up to first floor level. In Cement mortar 1:4 (1 cement: 4 coarse sand)\"for each subsequentfloor or part thereof above the first floor level. |
| 351 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). In mix 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) |
| 352 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: In Columns, Pillars, Piers, Abutments, Posts and struts (using steel). |
| 353 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: In Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 354 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: In Slabs, roofs, landings, balconies and access platform, shelves (using steel) |
| 355 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: In Stairs/ spiral staircase, (excluding landings) (using timber) |
| 356 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Thermo-Mechanically Treated bars |
| 357 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, fillets, columns, pillars, posts and struts etc. above plinth level up to first floor level, excluding cost of centering, shuttering, finishing and reinforcement: In mix M20 or 1 :11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 358 | 12 mm cement plaster of mix:1 : 4 (1 cement : 4 fine sand) |
| 359 | Providing, fitting and fixing steel windows (including ventilators) of standard rolled steel sections as per relevant I.S. Code, joints mitred and welded with 15x3xl00 mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65 mm and not less than 15 mm wide) bolting device, steel handles, pegs, stays of 300 mm long etc. complete including providing 12xl2 mm square bars duly welded to steel frame at not more than 12 cm c/c applying a priming coat of red-lead 1 1 .24 paint etc. complete as per drawing: Openable. |
| 360 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought trained and fixed in position with hold fast lugs or with dash fasteners of required diameter & length: With lst class Local wood.Champa/ Diengrai |
| 361 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately): With lst class Local wood.Champa/ Diengrai-35 mm thick shutters |
| 362 | Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) decorative type, core of block board construction with frame of 1 St class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 363 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete:125x85x5.5 mm (heavy type) |
| 364 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250xl0 mm |
| 365 | Providing and fixing bright finished brass handles with screws etc. complete:125mm |
| 366 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete: With 4.0 mm thick glass panes |
| 367 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS:15622 (thickness to be specified by the manufacturer) of approved make in all colours and shades of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1 :3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 368 | Providing polished VITRlFIED wall tiles of approved quality, size, shape and thickness not less than 8 mm on walls and skirting over cement mortar bed 10 mm thick in prop.1:3 (1 cement: 3 coarse sand) including cutting where necessary finished with flush pointing with adhesive or white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed: Deluxe range |
| 369 | Precast terrazzo tiles 22 mm thick with graded marble chips of sizes up to 12 mm, in skirting and risers of steps not exceeding 30 cm in height, on 12 mm thick cement plaster 1:3 (1 cement: 3 coarse sand), jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of Light shade pigment using white cement |
| 370 | Extra for marble stone flcoring, skirting, in treads of steps and sqm 514.00 risers using single length up to 2.00 metre` |
| 371 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding:Two or more coats applied on walls @ 1.25 Itr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr/10 Sqm |
| 372 | Providing and fixing wooden rounded hand rails in straight lengths with size of 100x60 mm complete as directed: With 1st class Local wood (Champa/ Diengrai and the like) |
| 373 | Providing and fixing 25x25 mm first class timber balustrade 25x25 mm square, wrought fixed with ends housed (square or splayed) to hand rails and trends or strips complcte.With 1st class Local wood (Champa/ Diengrai and the like) |
| 374 | Applying priming coat: With ready mixed red oxide zinc chromate primer Of approved brand and manufacture on steel galvanised iron/ steel works |
| 375 | Applying priming coat:With ready mixed pink or Grey primer Of approved brand and manufacture on wood work (hard and soft wood)/ with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood |
| 376 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: New work (two or more coats) |
| 377 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture: New work |
| 378 | Construction for Two Storyed Dormitory at Myntdu Leshka Stage-I. |
| 379 | Earthwork in excavation by Mechanical means up to a depth of 2m below the existing ground level tor foundation, trenches Of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils: In All kinds of soil (ordinary soil/ hard soil/dense soil) |
| 380 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete: Stone soling: 150mm thick. |
| 381 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level: In Cement mortar 1:6 (1 cement: 6 coarse sand) |
| 382 | Half brick masonry with common burnt clay (non modular) lst class bricks in superstructure above plinth level up to first floor level: In Cement mortar 1:3 (1 cement: 3 coarse sand) |
| 383 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately): In mix 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) |
| 384 | Cement concrcte floor topping 1:1:2 (1 cement: 1 coarse sand: 2 stone aggregate) finished with a floating coat of neat cement, including cement slurry, complete: 20 mm thick |
| 385 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge: In Foundations, footings, bases of columns, etc. for mass concrete (using steel). |
| 386 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge: In Columns, Pillars, Piers, Abutments, Posts and struts (using steel) |
| 387 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge: In Slabs, roofs, landings, balconies and access platform, shelves (using steel) |
| 388 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge: In Stairs/ spiral staircase, (excluding landings) (using timber) |
| 389 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge: In Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 390 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Thermo-Mechanically Treated bars |
| 391 | Reinforced cement concrete work in beams, slabs, roofs having slope up to 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to first floor level, excluding the cost of centerlng, shuttering, finishing and reinforcement: In M20 or 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 392 | 20 mm cement plaster of mix:1 :4 (1 cement: 4 fine sand) |
| 393 | Providing, fitting and fixing steel windows (including ventilators) of standard rolled steel sections as per relevant I.S. Code, joints mitred and welded with 15x3xl00 mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65 mm and not less than 15 mm wide) bolting device, steel handles, pegs, stays of 300 mm long etc. complete including providing 12xl2 mm square bars duly welded to steel frame at not more than 12 cm c/c applying a priming coat of red-lead 1 1 .24 paint etc. complete as per drawing: Openable |
| 394 | Providing wood work in frames Of doors, windows, clerestory windows and other frames, wrought trained and fixed in position with hold fast lugs or with dash fasteners of required diameter & length: With lst class Local wood/ Champa/ Diengrai |
| 395 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately): With lst class Local wood.Champa/ Diengrai-35 mm thick shutters |
| 396 | Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 397 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: 300mm x 10mm |
| 398 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete:125x75x4 mm |
| 399 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 5.5 mm thick glass panes |
| 400 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding:Two or more coats applied on walls @ 1.25 Itr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr/10 Sqm |
| 401 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 402 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)/ with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood |
| 403 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: New work (two or more coats) |
| 404 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture: New work |
| 405 | Providing and fixing 1st quality ceramic glazed tloor tiles conforming to IS:15622 (thickness to be specified by the manufacturer) of approved make in all colours and shades of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1 :3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 406 | Providing polished VITRlFIED wall tiles of approved quality, size, shape and thickness not less than 8 mm on walls and skirting over cement mortar bed 10 mm thick in prop.1:3 (1 cement: 3 coarse sand) including cutting where necessary finished with flush pointing with adhesive or white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed: Deluxe range |
| 407 | Precast terrazzo tiles 22 mm thick with graded marble chips of sizes up to 12 mm, in skirting and risers of steps not exceeding 30 cm in height, on 12 mm thick cement plaster 1:3 (1 cement: 3 coarse sand), jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of:Medium shades pigment using 50°/o white cement and 50°/o ordinary cement. |
| 408 | 40 mm thick marble chips flooring, rubbed and polished to granolithic finish, under layer 28 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 12.5 mm nominal size) and top layer 12 mm thick with marble chips of sizes from 7 mm to 10 mm nominal size, laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weighi in proportion of 2:3 (2 cement marble powder mix: 3 marble chips) by volume, including cement slurry eta. complete: Medium shade pigment with 50°/a white cement and 50°/o ordinary cement |
| 409 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid. |
| 410 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern. including painting of fittings and brackcts, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 411 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making gcod the walls wherever required: Kitchen sink with drain board.510xl040 mm bowl depth 250 mm |
| 412 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thickhard board backing: Circular shape 450 mm dia. |
| 413 | Providing and fixing toilet paper holder: C.P brass |
| 414 | Providing and fixing soil, waste and vent pipe 100mm diameter Sand cast iron S&S pipe |
| 415 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: 100 mm diameter |
| 416 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti-corrosive bitumastic paint, cutting chases and making good the wall: 15 mm diameter nominal bore |
| 417 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: Size 25 to 40 mm nominal bore |
| 418 | Providing and fixing brass stop cock of approved quality of Size 15 mm nominal bore |
| 419 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved qualfty for new work:15 mm diameter pipe |
| 420 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, Vc fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered). |
| 421 | Internal wiring:Wiringin looping system with copper PVC cable 250/440 volt grade of size 1.5sqmm of approved quality using PVC casing capping including 5 amperes switch Indian best quality ceiling rose etc. capable to the highest point: Long point wiring upto 10 mts. |
| 422 | Wiringin looping system with copper PVC cable 250/440 volt grade of size 2x2.5sqmm of approved quality using PVC casing capping including 5/15 amperes switch/socket Indian best quality complete to a light Plug point when fixed elsewhere with continous earth wire complete: Long point wiring upto 10 mts. |
| 423 | Wiringin looping system with copper PVC cable 250/440 volt grade of size 2x4sqmm of approved quality using PVC casing capping including 15 amperes switch/socket Indian best quality complete to Power Plug point with continous earth wire complete : Long point wiring upto 10 mts. |
| 424 | Wiringin looping system with copper PVC cable 250/440 volt grade of size 2x2.5sqmm of approved quality using PVC casing capping including 5/15 amperes switch/socket Indian best quality complete to Ceiling fan/ Exhaust fan point: Long point wiring upto 10 mts. |
| 425 | Drawing of main and sub main line with DGSD approved VIR or PVC 250/440 Volts grade copper conductor in PVC casing complete with all accessories: With 2x6mm2 Copper conductor |
| 426 | Drawing of 3 phasemain line 4 wire withDGSD approved VIR or PVC 660 Volts grade copper conductorcasing cappingwith all accessories: With 4x6mm2 Copper conductor. |
| 427 | Drawing of 3 phasemain line 4 wire withDGSD approved VIR or PVC 660 Volts grade copper conductorcasing cappingwith all accessories: With 4x16mm2 Copper conductor |
| 428 | Supplying fitting andfixing of industrial type 15 Amp complete with all necessary accessories as required: 15 Amp type socket. |
| 429 | Suppyingfitting and fixing Metal box of following sizes on surface or in recess with suitable size of Phendie laminated sheet cover in the front including painting etc as required: (75mmx75mm x 60mm deep) |
| 430 | Suppyingfitting and fixing Metal box of following sizes on surface or in recess with suitable size of Phendie laminated sheet cover in the front including painting etc as required: (100mmx100mm x 60mm deep) |
| 431 | Suppyingfitting and fixing Metal box of following sizes on surface or in recess with suitable size of Phendie laminated sheet cover in the front including painting etc as required: (150mmx75mm x 60mm deep) |
| 432 | Suppying and fitting of ceiling fan AC operated type 220/250 volt. Complete with 3 Nos of blades down rod canopy haning shackle & 30mm length of down rod supplied with the fan by the dealer but the extra length will be charged @ Rs 25.00/mtrs: AC ceiling Fan \"600\"mm sweep |
| 433 | Supplying fittings and fixing complete heavy duty double break fuse switches- HBC fuse type in sheet enclosure 50 Hz.415V. 3 pole with Neutral (T.P.N): 63Amp capacity. |
| 434 | Supplying fitting and fixing of distribution board,ETPN DB\"s for MCB, Isolator, RCCB and RCBO: IP 30-#1K 08: 8 ways 8+24 modules. |
| 435 | Supplying and fixing of load Kontaket Miniature Circuit Breakers DX3 MCB\"s for AC application till 63A: Double pole 415 V: 6-32 Amp. |
| 436 | Supplying fitting and fixingof DX3 Isolators for AC applications upto 125A: Double pole 240 V: 63Amp |
| 437 | Supplying fitting and fixing of water Heater (Geyser) of 1.5KW/3KW with pressure release valve including all necessary accessories as required: 15 litres capacity. |
| 438 | Supplying fitting and fixing of water Heater (Geyser) of 1.5KW/3KW with pressure release valve including all necessary accessories as required: 3 litres capacity. |
| 439 | Supplying, fitting and fixing earthing with copper earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipeetc. with charcoal/ coke and salt etc complete as required. |
| 440 | Supplyingfitting fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED bulb surface or wall mounted with all necessary accessories: Bulb - 23W |
| 441 | Supplyingfitting fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED bulb surface or wall mounted with all necessary accessories: Bulb - 7W |
| 442 | Supplyingfitting fixing of LED batten surface or wall mounted with all necessary accessories: with polycarbonate housing & integrated electronic driver: 20W (1150x 25x40mm). |
| 443 | Suppling fitting and fixing of LED PANEL LIGHTING surface or wall mounted with all necessary accessories: 2x2 (595x595x65)mm luminaire: 24W |
| 444 | Supply, installation, testing & commisioning of advanced Lightning protection system by using high pulse Ion generator of E.S.E. lightning conductor made of high quality stainless steel, as specified and directed by the deptt. [ as per NFC17-102], Make: PROTART or SCHIRTEC with lightning strike counter & lightning conductor Tester chemical earthing electrode copper coated 50mm Dia. & 2.0m length with ERIC grounding material, 75mm single core copper wire with all accessories for installation etc. |
| 445 | Supplying fitting and fixing single phase 230 volt grade motor complete: 2 HP Single motor phase |
| 446 | Supplying fitting and fixing push button type direct on line starter: 0-5 HP single phase |
| 447 | Supplying fitting and fixing of 50W Solar Street Light, 15 W 2 in 1 Luminary (Lithium ION Battery), 50 W Solar Panel GI Pole (20 feet) Galvanised complete with Structure Automatic Dusk to Dawn) complete as directed by Engineer-in-chage. |
| 448 | Supply fitting and fixing wall/table fan with all necessary attachment and accessories as required |
| 449 | Supply fitting and fixing exhaust fan double bearing self lubricating type single phase 50Hz 250V. AC operated complete with supporting frame, fan blade, nuts and bolts and other petty accessories as required: Dosmestic fan-250mm |
| 450 | Construction of Transit camp at Myntdu Leshka |
| 451 | Earthwork in excavation by manual means up to a depth of 2m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils: In All kinds of soil (ordinary soil/ hard soil/ dense soil) |
| 452 | Earthwork in excavation by Mechanical means up to a depth of 2 in below the existing ground level tor foundation, trenches of foundations, footings of column/ walls,etaining walls,septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils.In All kinds of soil (ordinary soil hard soil/dense soil) |
| 453 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete: Stone Soling: 100mm thick |
| 454 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level: In Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 455 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately): In mix 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) |
| 456 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation etc in layers not exceeding 20 cm thick including breaking of clods, consolidating each layer by ramming and watering, lead up to 50 m and lift up to 1.5 m with available excavated earth |
| 457 | 65 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 15 mm thick cement hardener consisting of mix 1 :2 (1 cement hardener mix: 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture\"s specifications. This includes cost of cement slurry, complete |
| 458 | Supplying, fitting and fixing in position reinforcement bars up to 1st floor level, conforming to relevant I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Thermo-Mechanically Treated bars |
| 459 | Supplying, fitting and fixing in position reinforcement bars up to 1st floor level, conforming to relevant I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Mild steel and Medium Tensile steel bars |
| 460 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: In Foundations, footings, bases of columns, etc. for mass concrete (using steel) |
| 461 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: In Lintels, beams, plinth beams, girders, bressumers and cantilevers (using steel). |
| 462 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: In Columns, Pillars,Piers,Abutments, Posts and Struts (using steel) |
| 463 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: In slabs, roofs, landings, balconies and access platform, shelves (using steel). |
| 464 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level: M15 or Prop.1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) |
| 465 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level: M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 466 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, fillets, columns,pillars, posts and struts etc. above plinth level up to first floor level, excluding cost of centering, shuttering, finishing and reinforcement: In mix M20 or 1 :11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 467 | Reinforced cement concrete work in beams, slabs, roofs having slope up to 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to first floor level, excluding the cost of centerlng, shuttering, finishing and reinforcement: In mix M20 or 1 :11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 468 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc„ including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 469 | Providing and fixing pre-coated galvanised iron profile sheets (size, shape and pitch Of corrugation as approved by Engineer-in-charge) 0.50 mm(+O.05 a/o) total coated thickness with zinc coating 120 grams per sqm as per ls:277, in 240 Mpa steel grade, 5-7 microns epoxy primer on both side of the shect and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 mcter or as desired by Engineer-in charge. The sheet shall be fixed using selfrdrilling/ self tapping screws of size (5.5x55 mm) with EPDM seal,complete up to any pitch in horizontav vertical or ciirved surfaces, excluding the cost of purlins. rafters and trusses and including cutting to size and shape wherever required. |
| 470 | Providing and fixing pro-coated galvanised steel sheet rcofing accessories 0.50 mm (+0.05 a/a) total coated thickness, Zinc coating 120 grams per sqm as per lS:277, in 240 Mpa Steel grade, 5-7microns epoxy primer on both side of the shect and polyester top coat 15-18: Ridges plain (500-600mm) |
| 471 | Providing and fixing pro-coated galvanised steel sheet rcofing accessories 0.50 mm (+0.05 a/a) total coated thickness, Zinc coating 120 grams per sqm as per lS:277, in 240 Mpa Steel grade, 5-7microns epoxy primer on both side ff the shect and polyester top coat 15-18: Gutter (600 mm over all girth) |
| 472 | Providing wood work in frames of false ceiling, partitions, etc. sawn and fixed in position with necessary stainless steel screws etc.: With 1st class Local wood: Pooma/ Hollock/ Gamari and the like. |
| 473 | Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) : Natural colour insulating board 12 mm thick |
| 474 | Half brick masonry with common burnt clay (non modular) 1st class bricks in superstructure above plinth level up to first floor level: In Cement mortar 1 :4 (1 cement: 4 coarse sand). |
| 475 | Brick work with common burnt clay modular 1st class bricks in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement: 6 coarse sand): From ground level up to plinth level. |
| 476 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required diameter & length: With Teak wood / Sissu wood. |
| 477 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately): With Teak wood / Sissu wood, 35 mm thick shutters. |
| 478 | Providing, fitting and fixing steel windows (including ventilators) of standard rolled steel sections as per relevant I.S. Code, joints mitred and welded with 15x3x100 mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65 mm and not less than 15 mm wide) bolting device, steel handles, pegs, stays of 300 mm long etc. complete including providing 12x12 mm square bars duly welded to steel frame at not more than 12 cm c/c applying a priming coat of red-lead paint etc. complete as per drawing: Openable. |
| 479 | Providing and fixing M.S. grills Of required pattern in trames of windows, etc. with M.S. flats, square or round bars, etc. including priming coat with approved steel primer all complete: Fixed to openings/ wooden frames with rawl plugs screws etc. |
| 480 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS:7231, with all fi\"ngs and fixtures complete. including cutting and making good the walls and floors wherever required: In White Vitreous china Orissa pattern W.C, pan of size 580x440mm with integral type foci rests. |
| 481 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P, flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling Of approved design complete, including painting Of fittings and brackets, cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid |
| 482 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern. including painting of fittings and brackcts, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 483 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern. including painting of fittings and brackcts, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps. |
| 484 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per ls:13983 with C.I. brackets and stainless steel plug 40 mm, including painting Of fittings and brackets, cutting and making gcod the walls wherever required : Kitchen sink with drain board: Size 510xl040 mm bowl depth 250 mm |
| 485 | Providing and fixing CP brass Single Lever Telephonic wall mixer of quality & make as approved by Engineer-in-charge |
| 486 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washer complete. |
| 487 | Providing and fixing toilet paper holder: C.P. brass |
| 488 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 in spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge: Concealed work, including cutting chases and making good the walls etc: 15 mm nominal outer diameter pipes. |
| 489 | Providing and fixing brass bib cock of approved quality 15 mm nominal bore |
| 490 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: 150 mm diameter |
| 491 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to lS:8931: 15 mm nominal bore |
| 492 | Providing and fixing PTMT pillar cock of approved quality and colour: 15 mm nominal bore, 107 mm long, weighing not less than 110 gins |
| 493 | Providing and laying vitrified floor tiles in different sizes (thickness to be specif led by the manufacturer) with water absorption less than 0.08% and conforming to ls:15622, of approved make, in all colours and shades laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete: Size of Tile 600x600 mm. |
| 494 | Tile work in skirting, risers of steps and dado up to 2 in height over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm., including pointing in white cement mixed with pigment of matching shade complete. |
| 495 | 12 mm cement plaster of mix::4 (1 cement : 4 fine sand) |
| 496 | 20 mm cement plaster of mix 1 :4 (1 cement: 4 fine sand) |
| 497 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including water thinnable priming coat with cement primer. |
| 498 | Applying priming coat: With ready mked pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)/ with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood |
| 499 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding: Painting wood work with Deluxe Mufti Surface Paint of required shade. Two or more coats applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 Itr/10 sqm of approved brand and manufacture |
| 500 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding: Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 501 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 5.5 mm thick glass panes |
| 502 | Providing and fixing soil, waste and vent pipes 100mm dia Sand cast iron S&S pipe as per IS: 1729 |
| 503 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete 100mm dia Sand cast iron S&S pipe as per IS: 1729 |
| 504 | Constructing soak pit 1.20x1.20x1.20m in filled with brickbats including S.W. drain pipe100mm diameter and 1.20m long complete as per standard design. |
| 505 | INTERNAL WIRING:Wiringin looping system with copper PVC cable 250/440 volt grade of size 1.5sqmm of approved quality using PVC casing capping including 5 amperes switch Indian best quality ceiling rose etc. capable to the highest point: Wall Light point in short point wiring upto 3 mts |
| 506 | Wiringin looping system with copper PVC cable 250/440 volt grade of size 2x2.5sqmm of approved quality using PVC casing capping including 5/15 amperes switch/socket Indian best quality complete to a light Plug point when fixed elsewhere with continous earth wire complete: Short point wiring upto 3 mts. |
| 507 | Wiringin looping system with copper PVC cable 250/440 volt grade of size 2x4sqmm of approved quality using PVC casing capping including 15 amperes switch/socket Indian best quality complete to Power Plug point with continous earth wire complete : Short point wiring upto 3 mts. |
| 508 | Wiringin looping system with copper PVC cable 250/440 volt grade of size 2x2.5sqmm of approved quality using PVC casing capping including 5/15 amperes switch/socket Indian best quality complete to Ceiling fan/ Exhaust fan point: Short point wiring upto 3 mts. |
| 509 | Drawing of main and sub main line with DGSD approved VIR or PVC 250/440 Volts grade copper conductor in PVC casing complete with all accessories. With 2x4mm2 Copper conductor |
| 510 | Drawing of 3 phasemain line 4 wire withDGSD approved VIR or PVC 660 Volts grade copper conductorcasing cappingwith all accessories. With 4x4mm2 Copper conductor |
| 511 | Drawing of 3 phasemain line 4 wire withDGSD approved VIR or PVC 660 Volts grade copper conductorcasing cappingwith all accessories. With 4x16mm2 Copper conductor |
| 512 | Supplying fitting andfixing of industrial type 15 Amp complete with all necessary accessories as required 15 Amp type socket |
| 513 | Suppyingfitting and fixing Metal box of following sizes on surface or in recess with suitable size of Phendie laminated sheet cover in the front including painting etc as required: (75mmx75mm x 60mm deep) |
| 514 | Suppyingfitting and fixing Metal box of following sizes on surface or in recess with suitable size of Phendie laminated sheet cover in the front including painting etc as required: (100mmx100mm x 60mm deep) |
| 515 | Suppyingfitting and fixing Metal box of following sizes on surface or in recess with suitable size of Phendie laminated sheet cover in the front including painting etc as required: (150mmx150mm x 60mm deep) |
| 516 | Suppying and fitting of ceiling fan AC operated type 220/250 volt. Complete with 3 Nos of blades down rod canopy haning shackle & 30mm length of down rod supplied with the fan by the dealer but the extra length will be charged @ Rs 25.00/mtrs.: AC ceiling Fan \"600\"mm sweep |
| 517 | Supplying fittings and fixing complete heavy duty double break fuse switches- HBC fuse type in sheet enclosure 50 Hz.415V. 3 pole with Neutral (T.P.N): 63Amp capacity |
| 518 | Supplying fitting and fixing of distribution board,ETPN DB\"s for MCB, Isolator, RCCB and RCBO: IP 30-#1K 08 : 8 ways 8+24 modules |
| 519 | Supplying and fixing of load Kontaket Miniature Circuit Breakers DX3 MCB\"s for AC application till 63A : Double pole 415 V (b) 6-32 Amp |
| 520 | Supplying fitting and fixingof DX3 Isolators for AC applications upto 125A: Double pole 240 V : 63Amp |
| 521 | Supplying fitting and fixing of water Heater (Geyser) of 1.5KW/3KW with pressure release valve including all necessary accessories as required: 15 litres capacity. |
| 522 | Supplying fitting and fixing of water Heater (Geyser) of 1.5KW/3KW with pressure release valve including all necessary accessories as required: 3 litres capacity. |
| 523 | Supplying, fitting and fixing earthing with copper earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipeetc. with charcoal/ coke and salt etc complete as required |
| 524 | Supplyingfitting fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED bulb surface or wall mounted with all necessary accessories: Bulb - 23W |
| 525 | Supplyingfitting fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED bulb surface or wall mounted with all necessary accessories : Bulb - 3W |
| 526 | Supplyingfitting fixing of LED batten surface or wall mounted with all necessary accessories: with polycarbonate housing & integrated electronic driver : 20W (1150x 25x40mm) |
| 527 | Suppling fitting and fixing of LED PANEL LIGHTING surface or wall mounted with all necessary accessories : 2x2 (595x595x65)mm luminaire - 24W |
| 528 | Supply, installation, testing & commisioning of advanced Lightning protection system by using high pulse Ion generator of E.S.E. lightning conductor made of high quality stainless steel, as specified and directed by the deptt. [ as per NFC17-102], Make: PROTART or SCHIRTEC with lightning strike counter & lightning conductor Tester chemical earthing electrode copper coated 50mm Dia. & 2.0m length with ERIC grounding material, 75mm single core copper wire with all accessories for installation etc. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy