Rate Contract For Supply Of Material For Ht/Lt Network In Divisional Store Rate Contract For Supply Of Material For Ht/Lt Network In Divisional Store Under The Jurisdiction Of Electric Division Vijaypur Jpdcl, Jammu , Al. Thimbles , 95Mm2 , 120Mm2 , 185 Mm2 , 240Mm2 , 300Mm2 , 400Mm2 , 630Mm2 , G.I Wire 8 Swg Conforming To Relevant Is Code , Guy Wire Conforming To Relevant Is Code , 7 Swg , 14 Swg , Lt Shackle Insulator Conforming To Is:1445 Of 1977 Ammended Upto Date. Having Size 90X75 Mm, Hole Dia 15 Mm, Creepage Distance Of 63 Mm. , 11 Kv Disc Porcelain Insulator Having Electro- Mechanical Strength Of 45 Kn, Net Weight Approximately 5Kgs, Minimum Creepage Distance Of 320Mm And Preferably Make Of Bihar Ceramics/ Hindustan Ceramics/Ri Conforming To Relevant Is Code 731 Of 1971 (With Latest Ammendment) , (I) B&S Type , (Ii) T&Ctype , 11 Kvploymer Disc Insulator Having Electro- Mechanical Strength Of 45 Kn,Minimum Creepage Distance Of 320 Mm Conforming To Relevant Is Code. , (I) B&S Type , (Ii) T&C Type , 11 Kv Disc Fittings Suitable Foracsr Sq./ Weasel/ Rabbit Conductor Conforming To Relevant Is Code , (I) B&S Type 1.200 Kg (Porcelain/Polymer) , (Ii) T&C Type 0.800 Kg (Porcelain/Polymer) , 11 Kv Disc Fittings Suitable Fordog Conductor Conforming To Relevant Is Code , (I) B&S Type 1.200 Kg (Porcelain/Polymer) , (Ii) T&C Type 0.800 Kg (Porcelain/Polymer) , 11 Kv G.I Pin Having Minimum Falling Load Of 5 Kn & Length Of 315 Mm. , (I) 0.800 Kg , (Ii) 0.850 Kg , 11 Kv Pin Insulator Having Minimum Falling Load Of 5 Kn And Minimum Creepage Distance Of 230Mm, Net Weight Approxmately 1.5 Kg Preferably Make Of Bihar Ceramics/ Hindustan Ceramics/ Ri Conforming To Iss-731 Of 1971 (With Latest Ammendments) , Porcelain Type , Polymer Type , 11 Kv Link Set Post Insulator (Polymer) Mounted Type Consisting Of Three Poles Having Two No. 11 Kv Post Insulator For One Poleconforming To Relevant Is Code Having Voltage Of 12 Kn, Knife Size 50X6mm. Fixed Contracts:- Copper Aluminium Alloy (Having Thefacility Of Replacing Of Damaged Copper Contacts) & Should Hold Knife. The Knife As Well As The Hinge Should Be Of Copper/Copper Aluminium Alloy With Circular Hook At The Top For Easy Operation Suitable Flexible Copper Bondign Wire To Be Provided With Clamps And Knife At Bottom Side.Channel Iron:-75X40x6 Mm , 11 Kv Link Set Post Insulator (Porcelain) Mounted Type Consisting Of Three Poles Having Two No. 11 Kv Post Insulator For One Poleconforming To Relevant Is Code Having Voltage Of 12 Kn, Knife Size 50X6mm. Fixed Contracts:- Copper Aluminium Alloy (Having Thefacility Of Replacing Of Damaged Copper Contacts) & Should Hold Knife. The Knife As Well As The Hinge Should Be Of Copper/Copper Aluminium Alloy With Circular Hook At The Top For Easy Operation Suitable Flexible Copper Bondign Wire To Be Provided With Clamps And Knife At Bottom Side.Channel Iron:-75X40x6 Mm , 11 Kv Porcelain D.O Set Alongwith Mesh With Insulators On Channel Iron 75X40x6 Mm Conforming To Relevant Is Code , 11 Kv Polymer D.O Set Alongwith Mesh With Insulators On Channel Iron 75X40x6 Mm Conforming To Relevant Is Code , Nuts And Bolts Of All Sizes Conforming To Relavant Is Code , (I) 1/2 X5, 6, 7,8, 9(Half Thread) , (Ii) 1/2X 2, 3, 4, 5 (Full Thread) , Pvc, Al. Single Core, Grade 1.1 Kv Levellt Cable Conforming To Relevant Is Code. , 25Mm2 , 35Mm2 , 50Mm2 , 95Mm2 , 120Mm2 , 185Mm2 , 240Mm2 , 300Mm2 , 400Mm2 , 630Mm2 , Pvc, Al. Un Armoured 3 1/2 Core, Lt Cable Conforming To Relevant Is Code. , 35Mm2 , 50Mm2 , 95Mm2 , 120Mm2 , 185Mm2 , 240Mm2 , 300Mm2 , Xlpe Insulated Screened & Pvc Sheated Armoured Electric Power Cable Heavy Duty With Aluminium Conductor 3-Core For 11 Kv , 35Mm2 , 50Mm2 , 95Mm2 , 120Mm2 , 185Mm2 , 240Mm2 , 300Mm2 , Cable Joining Kit, Outdoor For Termination Heat Shrinkable Suitable For 3-Core 11 Kv Cable , 35 Mm2 , 50 Mm2 , 95 Mm2 , 120 Mm2 , 185Mm2 , 300Mm2 , 630Mm2 , Straight Through Joint Kit For Heat Sinkablefor 3 Core 11 Kv Xlpe/Ab Cables , 35 Mm2 , 50 Mm2 , 95 Mm2 , 120 Mm2 , 185Mm2 , 300Mm2 , 630Mm2 , Al. Bus Bar Strip Of Sizes , 40X6 Mm , 50X6 Mm , 50X10 Mm , 50X12 Mm , 75X12 Mm , Porcelain Type Bus Bar Insulator Working On Lt 0.44 Kv Conforming To Relevant Is Code , Porcelain Type 11 Kv Guy Insulator Conforming To Relevant Is Code , Porcelain Type L.T Guy Insulator Conforming To Relevantis Code , 11 Kv Lightning Arrestor Stations Type Conforming To Relevant Is Code. Make:- Obelum/ Abb/ Siemens Alongwith Test Certificate , Station Type (Porcelain) , Station Type (Polymer) , Line Type(Porcelain) , Line Type(Polymer) , 11 Kv Porcelain G.O Set 400 Amp. Triple Pole Gang Operated Outdoor Type, Single Throw Single Breaktilting Type, Manually Operated, Air Break Per Phase I.E. 9 No. Post Insulator Per Switch Of Standard Make Conforming To Relevant Is Code Alongwith Rod, Handle Etc. , 11 Kvploymer G.O Set 400 Amp. Triple Pole Gang Operated Outdoor Type, Single Throw Single Breaktilting Type, Manually Operated, Air Break Per Phase I.E. 9 No. Post Insulator Per Switch Of Standard Make Conforming To Relevant Is Code Alongwith Rod, Handle Etc. , Manila Rope , 3/4 , 1 , Pp Rope , 1/4 , 1 , Chain Pulley Block With Rope 6 Mtr. And Lift 8 Mtr. , 1Mt , 2 Mt , 3 Mt , 5 Mt , Lt Spacer With Conductor Holding Clips And Best Suitable For , Single Phase, Two Wire , Two Phase, Three Wire , Three Phase, Four Wire , Three Phase, Five Wire , 11 Kv Ct/Pt Unitof All Ratio With Meter Conforming To Relevant Is Code , Earth Plate (M.S) , 300X300x6.3 Mm , 600X600x6.3 Mm , Common Salt Of Good Quality , Charcoal Dust Of Good Quality , Drill Bits , 6 Mm , 8 Mm , 10 Mm , 16 Mm , 20 Mm , Al. Ladder (Collapsible/Foldable)Conforming To Relevant Is Code , 8 Mtr. Long , 10 Mtr. Long , 12 Mtr. Long , Bamboo Ladder , 8 Mtr. Long , 10 Mtr. Long , 12 Mtr. Long , Hand Gloves For Operation Of 11 Kv Conforming To Relevant Is Code , Insulated Plier 8 Inch (Toparia/Topai) , Pvc Twin Cable 1.1 Kv Lt Servicecable Conforming To Relevant Is Code , 4 Mm2 , 10 Mm2 , 16 Mm2 , Red Oxide Paint (First Quality) , Al. Paint (First Quality) , Mccb, 4 Pole, 415V With Complete Accessories , 63 Amp. , 100 Amp. , 200 Amp. , 250 Amp. , 400 Amp. , 630 Amp. , Safety Belt Conforming To Relevant Is Code , Safety Jacket Conforming To Relevant Is Code , Safety Helmet Conforming To Relevant Is Code , Gumshoes Conforming To Relevant Is Code , Common Metering Instrument For Downloading Of Ct/Pt And Prodigy Meter (Sands Make) , Earthing Ppe3.0 Mtr. Long As Per Rec Norms , Megger 1 Kv(Wacco) , Megger 5 Kv (Wacco) , Prodigy Meter , Rain Coat , Screw Driver , Test Pin , Electrical Cutter Blades , Link Operating Insulatee Rod Conforming To Relevantis Code And Tested Working Voltage 11 Kv. , Rated Fuse Wire Of Different Rating , Clamp Meter/ Tong Tester , Gi Strip For Earthing , 50X6 Mm , 25X3 Mm , 40X6mm , Bi Metallic Clamps Withdouble U Binding Clamps , 12 Mm , 20 Mm , 25 Mm , 30 Mm , Pg Clamps , For Squirrel Conductor , For Weasel Conductor , For Rabbit Conductor , For Dog Conductor , Clamps For Ab Cable Suspension/Tension Full Assembly , Post Insulator , Polymer , Porcelain , Lt Ab Cable , 35 Sqmm , 50 Sqmm , 95 Sqmm , 120 Sqmm , 185 Sqmm , Ht Ab Cable , 35 Sqmm , 50 Sqmm , 70 Sqmm , 95 Sqmm , 120 Sqmm , 185 Sqmm , 240 Sqmm , I.P.C , 50 Mm2 , 120Mm2 , 185Mm2 , 240Mm2 , Led Bulb , 5 W , 10 W , 15 W , 65 W , Fuse Wire , 10 Amp , 20Amp , Single Phase Energy Meter Hpl Make 10-60 A , Threephaseenergy Meter Hpl Make 20-80 A , Anti Climbing Devicefor 11/33 Kv Level , Danger Plates For 11/33 Kv Level , U-Clamps (40X6mm) , Bus Bar Insulator , Ledflood Lights , 50 Watt , 100 Watt , 120 Watt , 150 Watt , Gi Mesh , Barbed Wire , Turn Buckle Rod (Complete Set ) 20 Mm , Guy Rod(Complete Set) 20 Mm , Earthing Rod 20 Mm , Meter Seals , 11/0.433-0.250Kv;50Hz, 25 Kva Aluminium Wound Distribution Transformer Of Latest Energy Efficiency Level-2 (New), Is1180 Part-I; 2014 As Per Latest Upto Date Amendment With Externally Fitted Mccb With Cable Box And 4X4 Mtrs. Suitable Cable Of Ratings. (Aluminium Wound Upto 200Kva, Copper Wound For 250Kva Or Higher Kva Ratings) , 11/0.433-0.250Kv;50Hz, 63 Kva Aluminium Wound Distribution Transformer Of Latest Energy Efficiency Level-2 (New), Is1180 Part-I; 2014 As Per Latest Upto Date Amendment With Externally Fitted Mccb With Cable Box And 4X4 Mtrs. Suitable Cable Of Ratings. (Aluminium Wound Upto 200Kva, Copper Wound For 250Kva Or Higher Kva Ratings) , 11/0.433-0.250Kv;50Hz, 100 Kva Aluminium Wound Distribution Transformer Of Latest Energy Efficiency Level-2 (New), Is1180 Part-I; 2014 As Per Latest Upto Date Amendment With Externally Fitted Mccb With Cable Box And 4X4 Mtrs. Suitable Cable Of Ratings. (Aluminium Wound Upto 200Kva, Copper Wound For 250Kva Or Higher Kva Ratings) , 11/0.433-0.250Kv;50Hz, 250 Kva Copper Wound Distribution Transformer Of Latest Energy Efficiency Level-2 (New), Is1180 Part-I; 2014 As Per Latest Upto Date Amendment With Externally Fitted Mccb With Cable Box And 4X4 Mtrs. Suitable Cable Of Ratings. (Aluminium Wound Upto 200Kva, Copper Wound For 250Kva Or Higher Kva Ratings) , 11/0.433-0.250Kv;50Hz, 400 Kva Copper Wound Distribution Transformer Of Latest Energy Efficiency Level-2 (New), Is1180 Part-I; 2014 As Per Latest Upto Date Amendment With Externally Fitted Mccb With Cable Box And 4X4 Mtrs. Suitable Cable Of Ratings. (Aluminium Wound Upto 200Kva, Copper Wound For 250Kva Or Higher Kva Ratings) , 11/0.433-0.250Kv;50Hz, 630 Kva Copper Wound Distribution Transformer Of Latest Energy Efficiency Level-2 (New), Is1180 Part-I; 2014 As Per Latest Upto Date Amendment With Externally Fitted Mccb With Cable Box And 4X4 Mtrs. Suitable Cable Of Ratings. (Aluminium Wound Upto 200Kva, Copper Wound For 250Kva Or Higher Kva Ratings) , Lt Distribution Box With Mccb At Incomer And Sfu At Outgoings A Per State Practice For 25 Kva Dt , Lt Distribution Box With Mccb At Incomer And Sfu At Outgoings A Per State Practice For 63/100 Kva Dt , Lt Distribution Box With Mccb At Incomer And Sfu At Outgoings A Per State Practice For 250 Kva Dt , Acsr Conductor Ofsize 20 Sqmm , Acsr Conductor Ofsize 30 Sqmm , Acsr Conductor Ofsize 50 Sqmm , Acsr Conductor Ofsize 100 Sqmm , Capacitor Bank 0F 30 Kvar For Automatic Power Factor Correction , Capacitor Bank 0F 75 Kvar For Automatic Power Factor Correction , Capacitor Bank 0F 100 Kvar For Automatic Power Factor Correction , 11Kv, Single Core 120 Mm2 Aluminium Round Wire Armoured Xlpe Cable , Frls , 11Kv, Single Core 185 Mm2 Aluminium Round Wire Armoured Xlpe Cable , Frls , 11Kv, Single Core 300 Mm2 Aluminium Round Wire Armoured Xlpe Cable , Frls , 11Kv, Single Core 400 Mm2 Aluminium Round Wire Armoured Xlpe Cable , Frls , Gi Pipe 150 Mm Dia With Required No Of Collars For Road Crossing Including Termination Points , Rcc Protective Cover Of Size 300 Mm (Width) X 300Mm (Length) X 60 Mm (Thickness) For Underground Cables , Route Marker , Warning Tape , Fault Detector For Under Ground Cable Network , Chemical Earthing Electrodes (40 Mm Dia And 4 Mm Thickness) And Chemical , 8 Mtr Long Pcc Poles Of 200 Kg Working Load , 9 Mtr Long Pcc Poles Of 300 Kg Working Load , 8 Mtr Long Steel Tubular Poles Of St-410Sp-15 Working Load , 9 Mtr Long Steel Tubular Poles Of St-410 Sp33 Working Load