Necessary arrangement for Electrical Installation work at Paediatric Ward and SNCU at Rampurhat Govt. Medical College and Hospital, Rampurhat, Birbhum. (Electrical Work) Project ID - HF252634813S000- 1 S&F Timer Control Unitforsingle phase AC Machine assembled with - 12-way SPN DB Box (L&T / Cabtree/Legrand/Siemens/ABB)- 1 no. 32 A DP MCB Isolator (Make: Siemense / Legrand / L&T)- 01 no. Digital 24 hour time switch (GIC/L&T) - 1 no.32A three pole contactor (L&T)- 01 no. Centre off2 way toggle switch - 1 no.32Amp. Barirrer type terminal- 1 no.LED indicating lamp(L&T: SIL R 240V) - 01 No.2X4sqmm+2.5sqmm copper wire0.5 Mtr.with complete interconnection with auto-mannual bypass arrangementwith locking arrangement incl. making/cutting door of SPN DB box for fixing arrangement of toggle switch, Locking arrangement, LED indicator etc. as required as per direction of EIC. [ For AC ] 2 Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish.Average run 8 mtr [PWD/GS Page: E - 24 Item: 1 ] 3 Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish On board[PWD/GS Page: E-20 Item: 3 ] 4 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. 2 x 4 sq mm + 1X 2.5 sqmm [VTPN/HTPN DB To Split AC & Geyser] 5 Do………………Do………………..Do………….2 x 2.5 sq mm + 1X 1.5[For Power Socket/Lift shaft light & socket] 6 Do…………………..Do…………………Do……………...3 x 1.5 sq mm 7 Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes 2 x 4 sq mm + 1X 2.5 sqmm [VTPN/HTPN DB To Split AC & Geyser] 8 Do………………Do………………..Do………….2 x 2.5 sq mm + 1X 1.5[For Power Socket/Lift shaft light & socket] 9 Do…………………..Do…………………Do……………...3 x 1.5 sq mm 10 Supplying and fixing 20 mm PVC Rigid Conduit FR [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. [PWD/GS Page: E-16 Item: 7/a ] 11 Supply & Fixing 240 V, 3 nos. 6 A, 3 pin Modular type plug socket & 1 nos. 6/16 A, 3 pin Modular type plug socket with 3 nos. 6A Modular type switch& 1 nos. 6/16 A, 3 pin Modular type switch (Brand approved by EIC), without plug top on 2 row 12 Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[PWD/GS Page: E-17 Item: 1,3, 4] 12 Supply & Fixing240 V, 2 nos. 6 A, 5 pin Modular type plug socket (Brand approved by EIC) with separate 2 nos. 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plateflushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc 13 Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [For AC + Geyser] [PWD/GS Page: E-17 Item: 5a] 14 Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc [PWD/GS Page: E-19 Item: 17] 15 Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. [For AC] [PWD/GS Page: E-17 Item: 5b] 16 Supply & Fixing 240 V, 1200 mm, 18/20 W, 110 lm/W single LED light fitting incl. LED Tube light (Fibre Body), suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.[Supply of light fittings/Light - Non-Schedule Item, Fixing of Light - PWD/GS Page: C-2 Item: 17 ] [Make Havells/ Wipro/Crompton/Bajaj/Philips] 17 Supply & Fixing 240 V, 1200 mm, 18/20 W,Double LED light fitting incl. 2 nos. LED Tube light (Fibre Body), suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.[Supply of light fittings/Light - Non-Schedule Item, Fixing of Light - PWD/GS Page: C-2 Item: 17 ] [Make Havells/ Wipro/Crompton/Bajaj/Philips] 18 Supply & Fixing 240 V, 1200 mm, 36-40 W, SUSPENDED/SURFACE MOUNTED LED light fitting incl light (Fibre Body), suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.[Supply of light fittings/Light - Non-Schedule Item, Fixing of Light - PWD/GS Page: C-2 Item: 17 ] [Make Philips - SM270C LED 30S 6500 PSU WH/ Crompton - LCTLRN-40-CDL(1X4)/Bajaj] 19 Supplying and Fixingof Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S & F 12mmdia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box.[PWD/GS Page: D-14 Item: 31 ] 20 Supply & Fixing 240 V, <50 W, 320 RPM, 1200 mm sweep ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessaryconnection as required by 2x1.5 sqmm flexible copper wire.(Make - Orient/Crompton/Havells)[Supply of Fan - Non-Schedule Item, Fixing of Fan - PWD/GS Page: C-3 Item: 21/a ] 21 Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.[PWD/GS Page: E-18 Item: 10] 22 Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required[PWD/GS Page: E-4 Item: 12] (a) 240 mm x 200 mm x 65 mm 23 (b) 150 mm x 100 mm x 65 mm 24 Supply & Fixing 240 V 6 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [PWD/GS Page: E-5 Item: 14] 25 Do…..............Do…......16/20A 26 Supply & Fixing 240 V, 6A plug socket (Brand approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover byscrews after making housing for plug by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. [PWD/GS Page: E-5 Item: 15] 27 Do…..............Do…......20A 28 Supplying & Fixing 240 V AC/DC superior type Multitune (min 10 nos. tune) Call Bell (Anchor) with selector switch for single/Multi Tunes mode, Battery operated on HW board incl. S&F HW board.[PWD/GS Page: D-13 Item: 20/c ] 29 Note:- Labour welfare Cess @ 1% and GST @ 18% on Bill amount will be deduct.