}

Providing Of Lighting Luminaries And Fitting, Fixing At River Bed And Lowering, Withdrawing Of Submersible Pump Set At Shemalya Pump House Under Shemalya W/S Scheme., Paschim Bardhaman-West Bengal

Public Health And Engineering Department has published Providing Of Lighting Luminaries And Fitting, Fixing At River Bed And Lowering, Withdrawing Of Submersible Pump Set At Shemalya Pump House Under Shemalya W/S Scheme.. Submission Date for this Tender is 23-06-2025. Tube Light Tenders in Paschim Bardhaman West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

49529128
Providing Of Lighting Luminaries And Fitting, Fixing At River Bed And Lowering, Withdrawing Of Submersible Pump Set At Shemalya Pump House Under Shemalya W/S Scheme.
Tender
Indian
West Bengal
Paschim Bardhaman
23-06-2025

Tender Documents

Tender Details

Providing Of Lighting Luminaries And Fitting, Fixing At River Bed And Lowering, Withdrawing Of Submersible Pump Set At Shemalya Pump House Under Shemalya W/S Scheme.- 1 Supply and delivery of following materials at site:- 2 4 Core X 10 Sqmm, 1.1 KV Grade XLPE insulatedAl.Ar Cable.(From DB Box to Pole to Pole)(Make-Approved Make) 3 3 Core X 2.5 Sqmm industrial flexible copper cable wire/dia-30/0.25 PVC insulated with PVC sheathed.(Make:Approved Make)(For 4 Nos Flood Light ) 4 200 Watt High efficiency IP:66 LED flood light with pressure die cast aluminium housing in rectangle shape and toughened glass in the front. Best suitable for area lighting.(Make-Approved Make) 5 11.0 Mtr. Long swaged and welded steel tubular pole as per IS-2713-1980 with CI Base Plate & CI Cap.(Make:-Approved Make)(For Lowlift Pumping Machineries) 6 Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly. 7 Above 9.0 mtr. Size 0.6x0.6x1.91 mts. 8 Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below,Comprising of one 250 V,15 A Kit-Kat fuse unit, one NL on,porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1)after dismantling the damaged looping cable box etc. where necy. incl. painting. 9 (250 x 250 x 100mm) (For 2 Nos Flood light 11 Mtr. Pole) 10 Connecting the pole to earth busbar including S & F GI(Hot Dip) wire of size as below,spiral on pole body as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. 11 No. 12 SWG. 12 Earthing with GI earth spike(1822mmX20 mm) and grouted the same under the ground level as per direction. 13 Laying of one No. 4 Core X 10 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection onthe top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.( From Pole to Pole) 14 DBs to Pole to Pole. 15 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 16 4 Core X 10 Sqmm. 17 Fixing only Floodlight Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure. 18 Supply and fixing of 3 Blade 1200 mm Sweep ceiling fan, 220V-240V,50 Hz, AC.(Make:-Approved Make) 19 Supply of 300 mm Sweep exhaust fan 220V-240 V,50 Hz, Single phase.(Make:-Approved Make) 20 Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. 21 4 Module. 22 Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required. 23 Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/ perspex top cover by screw incl. making necy. connections etc. 24 Supply and fixing of Modular type indicator. 25 Distribution wiring in 1.1 KV single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make) incl. necy. fittings as required. 26 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC. 27 Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 300mm.(At Toilet) 28 Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.(From Pole to Chlorine Room) 29 RBTWs repairing Portion:- 30 Supply and delivery at site of vertical submersible pumping machinery directly coupled with wet winding type suitable size submersible motor with following specification:Capacity 33m3/Hr. at a head of 26 mtrs.,Motor submersible type-3.7 kW/5 HP, 3 phase,50 Hz, ± 3% ,415 Volt ± 6% , 2900 RPM as per Technical Secification. (DOL Starter)(Make:-KSB/Texmo/Other approved make) 31 Supply and delivery and storageat site 3 Core X 10 Sqmm Al.Ar. Cable , XLPE Insulated 1.1 KV Grade conforming to IS 7098(I)and as per Technical Specification.(Test certificate and guarantee certificate is to be submitted at the time of delivery) 32 Withdrawing of submersible pumping machineries from old river bed Tube Well along with Column pipe after disconnection of all pipe line and power line connection with the help of Derrick and Chain Pulley arrangement by engaging skilled technician as per direction of EIC.(From 3 & 7 Nos RBTW) 33 Earth work in excavation of Cable line trenches, in all sorts of soil including removing, spreading or stacking the spoils within a lead of 75 m. as directed &filling the same with excaveted soil including ramming dressing after all complete. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom,bailing out water as required complete.Depth of excavation not exceeding 1,500 mm. 34 Laying 3 Core X 10 Sqmm through existing soil trench. 35 Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm.including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)With earth obtained from excavation of foundation. 36 Supply and delivery of GI wire for cable binding. 37 Laying of 3 Core X 10 Sqmm Al. Ar. Cable along the length of G.I. collecting line including binding with supplied GI wire at a suitable interval so as to prevent sagging of cable complete as per direction of EIC. 38 Making straight through joint between 1.5 mm2 or 2.5 mm2(motor cable) and 3 core X 4 mm2 flat submersible copper cable for extension of motor cable up to required lengh by supplying necessary seal kit to make joints leak proof all complete as per direction. 39 Making straight through joint between 3 core 6 mm2 flat submersible cable and 3 Core X 4 sqmm Al Armoured cable by supplying necessary seal kit and hardener to make joints leak proof all complete as per direction.(With Out Kit) 40 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials for 3 Core X 10 Sqmm cable.(To connect feeder terminal) 41 Straigh through Jointing of cable of different size by compound jointing kit including S&F ferrul, tapes and jointing materials (Brand approved by EIC)(4 Core X 10 Sqmm) 42 Lowering of Submersible pump Motor set along with 80 mm dia Column pipe part by part in the existing Tube Wells with an arrangement of Derrick and Chain Pulley arrangement, making Pipe line connection etc. all complete as per direction of EIC.( In Newly sunk RBTWs No-1,2 & 3)(Other Pump taking from RBTW No-03) 43 Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment.(4 Way) 44 Supplying and fixing, FP, 40 Amp, 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.(Make:-Havells) 45 Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required. 46 Supply and fitting, fixing of 4.5 KW/6.0 HP DOL starter relay range 6-10 Amp, 415 Volt AC-3 Phase,50 Hz, with coil voltage-360V-W (200V-400V).(Make-L & K, Model No-MK1.i, Cat No-CS91646SOVO) 47 Add GST @ 18% 48 Add CESS @ 1%

Key Value

Document Fees
Refer document
EMD
INR 18000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail