| 1 | Taking down carefully old unserviceable aluminum/ copper point wiring (light, fan, socket or power) complete, including fittings & fixtures such as switches, ceiling roses, lamp holders, pendants, regulators sockets,junction/terminal boxes etc;removing from site and making good disturbed surfaces of walls, floors etc., to match with existing surrounding surfaces complete all as specified and as directed. |
| 2 | Taking down existing unserviceable main switches/ distribution boards/Fuse Units of any description alongwith MCBs/MCCBs and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed. |
| 3 | Taking down carefully old unserviceable light fittings only and removing from site complete all as specified and as directed. |
| 4 | Taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed. |
| 5 | M&L for Point wiring two single core 1.5 sqmm size PVC insulated, unsheathedFRLSH multistranded copper conductor cable and one single core 1.5 sqmm size green colour PVC insulated FRLS multistranded copper conductor cable as earth continuity conductor, 1100 volt grade (with proper colour coding Red/Blue/yellow for phase, black for neutraland green for earth) complete drawn through and including PVC casing and caping not less than 25 mm width with all fittings, surface on wall/roof /floor including including sunk pressed steel terminal boxesflush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with suitable size of modular cover plates complete in making good the existing surface with existing colour coding as required at site complete all as specified for the following : Note :- The unit rate quoted shall deemed to include the cost of following :- |
| 6 | ONE LIGHT/FAN point controlled by one, one way 5 Amps switch. |
| 7 | ONE 5A SOCKET OUTLET point controlled by one, one way 5 Amps switch on independent board. |
| 8 | ONE 5A SOCKET OUTLET point controlled by one, one way 5 Amps switch on same board. |
| 9 | ONE BELL point controlled by one, one way5 Amps switch. |
| 10 | Description same as per item Sl No 5above but point wiring with two single core 4.0 Sqmm size cables and one 4.0 sqmm green colour cable as earth continuity conductor for one 3 pin 15 Amps socket out let on independent board complete all as specified and directed. |
| 11 | M & L point wiring complete with 1100 volts grade, 1.5 sq.mm (nominal area), single core, FRLSH PVCinsulated ,unsheathed, multi stranded copper conductor cable drawn through and including medium grade, rigid , non-metallic PVC conduit (surface or concealed as required) of size not less than 20 mm dia, with all necessary fittings, in walls/ floor or surface on wall/ roof duly earthed with one run of single core cable of same size but green incolour as continuous earthing wire and connecting to common earth duly including suitable size of factory made fabricated MS sheet modular terminal box, flush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with suitable size of modular cover plates complete in making good the existing surface with existing colour coding as required at site complete all as specified for the following :- |
| 12 | ONE LIGHT/FAN point controlled by one, one way 6 Amps modular switch. |
| 13 | Two light point controlled by one switch 5 Amps one way complete all as specified and directed. |
| 14 | ONE 6A SOCKET OUTLET point controlled by one, one way6 Amps modular switch on independent board. |
| 15 | ONE 6A SOCKET OUTLET point controlled by one, one way6 Amps modular switch on same board with other switches. |
| 16 | ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps switch on independentbut below the switch board of light point with cable of 1.5 Sqmm size. |
| 17 | ONE BELL point controlled by one, one way 6 Amps modular switch. |
| 18 | Description same as per item Srl No.7.00 above but point wiring with 4.0 sqmm PVC FRLS insulated multistranded copper conductor suitable for one 3 pin 15 Amps socket out let and one run of 4.0 sqmm cable for earth in green colour on independent board complete all as specified and directed. |
| 19 | S & F for switchmodulartype, 6 Amps 1 module, 230 volts AC circuit complete all as specified anddirected. Make : Roma (Anchor) / Havells (Crabtree) / Legrand. |
| 20 | S & F for socket outlet modular type 1 way 6 Amps, 3 pin, 230 volts AC circuit complete all as specified anddirected. Make : Roma (Anchor) / Havells (Crabtree) / Legrand. |
| 21 | S & F for switchmodulartype, 16 Amps 1 module, 230 volts AC circuit complete all as specified anddirected. Make-Make : Roma (Anchor) / Havells (Crabtree) / Legrand. |
| 22 | S & F Socketoutlet 2 in 1 modular type,3 pin, 6 and 16, universal complete all as specified and directed. Make : Roma (Anchor) / Havells (Crabtree) / Legrand. |
| 23 | S & F modular bell push 5 Amps 1 modular 230v, 50Hz AC complete all as specified and directed. Make : Roma (Anchor) / Havells (Crabtree) / Legrand. |
| 24 | S & F for switchmodulartype, two way 6 Amps 1 module, 230 volts AC circuit complete all as specified anddirected. Make : Roma (Anchor)/ Legrand/ Havells |
| 25 | S & F stepped type modular fan regulator, 2 modular type complete all as specified and directed. Make : Roma (Anchor) / Havells (Crabtree) / Legrand. |
| 26 | S & F Switch piano, flush type, single pole one way 5 amps all as directed. Make: Anchor/Cona/Legrand |
| 27 | S & F Switch piano, flush type, single pole one way 15 amps all as directed. Make: Anchor/Cona/Legrand |
| 28 | S & Fsocket outlet 2 in 1, 3 pin 5 amp, flush type, universal all as directed. Make: Anchor/Cona/Legrand. |
| 29 | S&F Socketoutlet 2 in 1,3 pin, 5 and 15,flush type, universal all as directed. Make: Anchor/Cona/Legrand. |
| 30 | S & F bell push switch,flush type, single pole, 5 Amps, 240 volts ACall as directed. Make: Anchor/Cona/Legrand. |
| 31 | M&L for ceiling rose,three terminal, 65x20mm size, PVC/Polycarbonate, insulated body, 5A, 240 volts complete all as specified and as directed. |
| 32 | S&F in repairs switch socket combination box type 2 in 1, 5 pin, 5 Amps, flush type,universalcomplete all as specified and as directed. Make: Anchor/Cona/Legrand |
| 33 | S&F in repairs switch socket combination box type 2 in 1, 6 pin, 5 Amps & 15 Amps, flush type,universalcomplete all as specified and as directed. Make: Anchor/Cona/Legrand |
| 34 | S&F electric bell, ding dong type, AC, 230 volts complete all as specified and as directed. Make: Anchor/Cona/Legrand |
| 35 | S&F in repairs fan regulator, electronic socket two module step type 120W complete as specified. Make : Anchor/Cona/Legrand |
| 36 | S & Fin replacement of capacitor 2.5mfd, 230 Volts for ceiling fans including taking out old unserviceable one complete all as specified and as directed. Make:- Tibcon/ Universal or equivalent. |
| 37 | M & L Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface with or without reinforcement all as specified and as directed by Engineer-in- Charge. |
| 38 | Taking down carefully ceiling fan of any sweep/ cap/ make from its existing position of any height/ loaction after disconnecting from electricity, dismantling blades, opening upfor carrying out servicing/over hauling, examining for damaged worn out parts like shaft, ball bearings etc., and applying grease to bearings, assembling back, preparing painted surfaces by cleaning dust, grease etc., and by filling cavities with filler to receive spray paint using synthetic enamel paint of existing shade, fixing up blades and hanging back in position and providing and connecting up with 1.0 sqmm twin core twisted flexible copper conductor of suitable length from connector of fan to ceiling rose and testing complete all as specified and as directed. NOTE: Spare parts like ball bearings, shafts etc shall be replaced only if found damaged and certified by Engineer-in-charge. If spares are replaced, they shall be measured and paid separately as SUPPLY ONLY. |
| 39 | Description same as per item Sl No 28.00 above but, exhaust fan of any sweep/cap/type complete all as specified and directed. |
| 40 | Description same as per item Sl No 28.00 above but, wall mounted fan of cap 400 mm sweep complete all as specified and directed. |
| 41 | Description same as per item Sl No 28.00 above but, wall mounted Indusatrial fan of 600 mm sweep complete all as specified and directed. |
| 42 | Taking down of unsv flame proof exhaust fan of cap 380 mm sweep of any make from its existing position and rewinding by super enamelled copper winding wire of suitable gauge and size with Garware insulating paper, insulating varnish and oven drying for requisite insulation values including necessary PVC sleeves lead wires and testing after assembling in position in exhaust fan complete all as specified and as directed. |
| 43 | Description all as per item No 32.00 above but exhaust fan (except flame proof) of any size/make/cap (300 to 450 mm sweep). |
| 44 | Description all as per item No 32.00 above but wall mounted fan of cap 400 mm sweep. |
| 45 | Description all as per item No 32.00 above but wall mounted Industrial fanof cap 600 mm sweep. |
| 46 | Suplly only ball bearing suitable for ceiling fan with bearing No. 6201/6202 complete all as specified and as directed. |
| 47 | Suplly only shaft suitable for ceiling fan 1200mm/1400mm sweep complete all as specified and as directed. |
| 48 | S & F exhaust fan blade set of 250/300/380mm sweep (steel body) complete all as specified and as directed. |
| 49 | S & F Air ventilation fan blade set of 200/250 mm sweep (PVC body) complete all as specified and as directed. |
| 50 | Suplly onlywall mounted fan blade set of 400mm sweep complete all as specified and as directed. |
| 51 | M & L for repair/ replacement of exhaust fan supporting MS frame with legs suitable for exhaust fan of cap 300 mm sweep complete all as specified and directed. |
| 52 | S & F Fan motor not less than 1200 RPM, 230 volt, single phase for Air ventilation fan of cap 200/250 mm sweep (PVC Body)complete all as specified and as directed. |
| 53 | S & F Fan motor not less than 1400 RPM, 230 volt, single phase for Exhaust fan of cap 300-450 mm sweep (steel body) complete all as specified and as directed. |
| 54 | Taking down carefully ceilingfan of any make, size from its location, handed over to AGE E/M store yard without any damage |
| 55 | S & F BLDC 5 star rated ceiling fan metallic body ISI marked 1200 mm sweep, 220V AC, 50 Hz with all accessories alogwith providing and connecting up with 1.0 sqmm 3 core flexible copper conductor of suitable length from connector of fan to ceiling rose and testing complete all as specified and as directed by Engr In charge.Make: Usha , Model No TECHNIX or equivalent to CG/ Havells/ BajajLuker |
| 56 | Taking down carefully electric geysers of any make, type and capacity after disconnecting of electrical and water connections, opening of bottom cover, checking of all parts and taking out copper tank, checking of its leakage and removing the dust, brazing the leakage and painting of geysers with two coats of synthetic enamel paint, replacement of wornt out spares and reassembling the geyser and re-fixing back in its original position complete all as specified and as directed. NOTE: Spares shall be measured and paid separately under relevant items as SUPPLY ONLY. |
| 57 | S & F high speed air ventilating fan 300mm sweep single ph, 230 volt, steel body with louversincl all fixing arrangement complete all as specified and directed. |
| 58 | S & F air ventilating fan 200mm sweep single ph, 230 volt, PVC body with louversincl all fixing arrangement complete all as specified and directed. |
| 59 | Supply only heating element 1500 watts. |
| 60 | Supply onlythermostat switch. |
| 61 | SUPPLY ONLY pressure release valve. |
| 62 | SUPPLY ONLY thermal cut out. |
| 63 | SUPPLY ONLY indicator lamp RED/GREEN colour. |
| 64 | SUPPLY ONLY PVC connection 15mm size with PTMT nuts of length 600mm. Make:- Prayag/ Polytuff |
| 65 | Supply & fix Modular Ac Box With 20A DP MCB \"C\" Type, Metal Enclosure & Unbreakable Heavy Duty With ISI Plug Top, 240 volts AC supply for air conditioner, flush mounting in the wall complete all as specified and directed.Make : Anchor/ Legrand/ Havells. |
| 66 | M&L for Sub main wiring complete with four runs (3P+1N) of 10.0 Sqmm single core, PVC insulated unsheathed, FRLSH cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 10.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32 mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25 mm dia PVC conduit and conduit accessories fixed in concealed or on surface of wall/ceiling/roof/ floor complete all as specified and as directed. |
| 67 | Description same as per item Sl No 56.00 above but sub main wiring with four runs (3P+1N) of 4.0 Sqmm single core duly earthed with one run of single core cable of same size but green incolour as continuous earthing wire. |
| 68 | Description same as per item Sl No 56.00 above but sub main wiring with four runs (3P+1N) of 6.0 Sqmm single core duly earthed with one run of single core cable of same size but green incolour as continuous earthing wire.NOTE for item No 56 & 58: Four runs (3P+1N) of copper conductor, One run ofcopper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length. |
| 69 | Description same as per item Sl No 56.00 above but sub main wiring with two runs (1P+1N) of 6.0 Sqmm single core duly earthed with one run of single core cable of same size but green incolour as continuous earthing wire. |
| 70 | Description same as per item Sl No 56.00 above but sub main wiring with four runs (1P+1N) of 4.0 Sqmm single core duly earthed with one run of single core cable of same size but green incolour as continuous earthing wire. |
| 71 | Description same as per item Sl No 56.00 above but sub main wiring with two runs (1P+1N) of 1.5 Sqmm single core duly earthed with one run of single core cable of same size but green incolour as continuous earthing wire.NOTE for Item No( 59 to 61): Two runs (1P+1N) of copper conductor, One run of1.5 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length. |
| 72 | S & Fin replacement of DB VTPN 4 Way sheet metal enclosure double door IP 43 protection, door earthsuitable for incoming upto MCCB 100 Amps/ 200 Amps & outgoing MCB TP / SP/ TPN415 V, with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete and making good to the distrubed surface /walls all as specifiedanddirected. |
| 73 | Description all as above Item No 62.00 but VTPN 6 way. |
| 74 | S & Fin replacement of Triple pole and neutral sheet steel powder coated Distribution board IP -43 protection with door earthing for MCBs fitted with 200 Amps rated busbar , Neutral link ,Earth Bar and Din rail suitable for use on 415 V, 50 Hz supply doubledoor TPN DB system04 ways, and making good to the distrubed surface /walls complete all as specifiedanddirected. |
| 75 | S & Fin replacement of MCB DB, SPN, 12-way, double door, 240 Volts with 200 Amps rated bus bar, IP-43 protection, shrouded neutral bus bar, cement spill protector, concealed in wall and making good disturbed surfaces to match with surrounding surface complete all as specified and as directed. |
| 76 | Description same as per item Sl No 65.00 above but 8 way. |
| 77 | Description same as per item Sl No 65.00 above but 4 way. |
| 78 | S & F in replacement of MCCB, 4 pole, 125 Amps, 50Hz, 25KA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release alongwith copper separator terminals complete all as specified and as directed. |
| 79 | S & F in replacement of MCCB, 3 pole, 100 Amps, 50Hz, 25KA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release alongwith copper separator terminalscomplete all as specified and as directed. |
| 80 | S & F MCB TPN 40-100 Amps (`C’ series) having current rating 10 KA complete all as specified and directed. |
| 81 | S & Fin replacement of MCB, TP, \"C\" series, 230 volts, 25-63 Amps, 10 KA rupturing capacity complete all as specified and as directed. |
| 82 | S & Fin replacement of MCB, SPN, \"C\" series, 230 volts, 32 Amps, 10 KA rupturing capacity complete all as specified and as directed. |
| 83 | S & Fin replacement of MCB, SP, \"C\" series, 240 volts, 6 to 32 Amps, 10 KA rupturing capacity complete all as specified and as directed. |
| 84 | S & F in replacement of RCCB for earth leakage protection double pole, 240 volts, 40 Amps, 100 mA rupturing capacity complete all as specified and as directed. |
| 85 | S & F in replacement of RCCB for earth leakage protection four pole, 415 volts, 80 Amps, 100 mA rupturing capacity complete all as specified and as directed. |
| 86 | Supply and fixing Insulated Plug & Socket with single pole + neutral and earth encolsure with a three pin plug with socket complete with one MCB SPN of 32Amps (`C’ series) having current rating 10 KA all as specified and directed. |
| 87 | Supply and fixing Insulated Plug & Socket with three pole + neutral and earth encolsure with a five pin plug with socket complete with one MCB TPN of 20-32Amps (`C’ series) having current rating 10 KA all as specified and directed. |
| 88 | S & Fin replacement of 18 watts surface mounted LED light fitting , white/yellow colour as reuired as sitewith slim high perfomanance surfaced mounted LED light fittings, round/square shape as required at site made from die-cast aluminium and CRCA covering, powder coated in white colour complete all as specified and directed. MAKE : Havells/CG/Philips/Bajaj/ Luker. NOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting |
| 89 | S & Fin replacement ofof LED slim panel lighting fixture aluminium housing of 18 Watt recessmounted220V , 50Hzwith finished in premium white powder coating ,environmental friendly energy efficient fitting recessmounted round/squarein shape(Warm white/ white colour as per requirement of site complete) of light as required at site) complete all as specified and directed. Make : CG/ Philips/ Havells/Bajaj/ Luker |
| 90 | Description all as item No 79.00 above but 15 watt recessmounted. Make : Havells/CG/Philips/Bajaj/ Luker. |
| 91 | Description all as item No 79.00 above but 12 watt recessmounted. Make : Havells/CG/Philips/Bajaj/ Luker. |
| 92 | Description all as item No 79.00 above but 9 watt recessmounted. Make : Havells/CG/Philips/Bajaj/ Luker.NOTE for item No 79.00 to 82.00 : The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting. |
| 93 | S & F andtesting Tube light fittings aluminium housing 22 watts 4 feetincluding all accessories and fixing arrangements for fixing the light fitting complete all as specified anddirected. Make : Havells/CG/Philips/Bajaj/ Luker. |
| 94 | S & Fin replacement andtesting Tube light fittings LED 10 watts 2 feetincluding all accessories and fixing arrangements for fixing the light fitting complete all as specified anddirected. Make : Havells/CG/Philips/Bajaj/ Luker. |
| 95 | S & Fin replacement of LED tube of cap 20 watt, 4\" long suitable for flame proof light fitting or any light fittings installed at any position incl taking down of fitting and re-fixing of the same after replacing the tube all as specified and directed by Engr In Charge. Make : Havells/CG/Philips/Bajaj/ Luker. |
| 96 | S & Fin replacement of Decorative, wall mounting, champagne gold finish fixture with plastic body suitable for 9 W LED lamp B22 base all as specified and directed. Make- Havells model No LHFOECE1TZ1O014 or equivalent in Philips/CG/Bajaj. |
| 97 | S & Fin replacement of concealed cob/ spot LED light energy efficient of cap 4 watt(WH/WW/NW of colour) LED for low ceiling height applications round in shape, pressure die-cast aluminium housing, spring loaded clips for easy mounting complete all as directed. Make : Havells/CG/Philips/Bajaj/ Luker. |
| 98 | Description all as per per Item No 87.00 but 12 watt. Make : Havells/CG/Philips/Bajaj/ Luker. |
| 99 | Supply and fixing andtesting Mirrior light fitting of cap 20 watt with all fixing arrangements all as specified and directed. Make : Havells cat no LHLDESAARANC020or equivalent in Philips/ CG/Bajaj. |
| 100 | S & F of 30 watts surface mounted LED light fitting , white/yellow colour as reuired as sitewith slim high perfomanance surfaced mounted LED light fittings, round/square shape as required at site made from die-cast aluminium and CRCA covering, powder coated in white colour complete all as specified and directed. MAKE : Havells/CG/Philips/Bajaj/ Luker. |
| 101 | S & Fin replacement ofandtesting LED recessed mounted 595 mm x 595 mm luminarie with high transmitive diffuserof cap 40 watt, with longer life and less maintenance including all accessories and fixing arrangements for fixing the light fitting complete all as specified anddirected. Make :Havells/CG/Philips/Bajaj/ Luker.NOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting. |
| 102 | S & F Surface mounted general purpose square shaped luminaire with low height CRCA housing and high transmissivity diffuser of cap 40 watt of size 595 mm x595mm x 65 mm including all accessories and fixing arrangements for fixing the light fitting to any heighted indoor palces complete all as specified anddirected.Make :Havells/CG/Philips/Bajaj/ Luker. |
| 103 | S & Fin replacement ofLED, AC Rope Strip light,60 LED per metre, of any colour (WW/NW/CDL), including all fixing arrangment as per site requirement complete all as specified and as directed. Make: Havells model No -LHEHBQP5TN6F325 or equivalent to Philips /CG/ Bajaj. |
| 104 | S & F FUOCO track LED light 12 watt, (WH/WW/NW) on channel of suitable size of required lengthall as specified and directed by Engr In charge.. Make : Havells/CG/Philips/Bajaj/ Luker. |
| 105 | S & F Step Light LED light of cap 2 watt, recess mounted , aluminium housing 30 lm/watt complete all as specified and directed. Make : Philips model No -30974 or equivalent in Bajaj/CG/Havells. |
| 106 | Supply and fixing in replacement integral LED high bay light fittings not less than 120 watts of lumen output capacity with minimum system efficiency > 110/Lumens/watts of colour temperature 5700K, IP 65, heat proof silicon rubber righ high presure die cast aluminium high transmittance tempered glass cover, including driver and controll accessories complete set with operation voltage between 140w-270w AC PF>.95 with T&P and fitting accessories including 3 core copper cable of size 2.5sqmm connection complete including 3 meter suspension chain (heavy duty, capable of catering load of ibid fitting) all as specified and directed by Engineer-in-Charge.Make : Havells/CG/Philips/Bajaj/ Luker.Note :- (i) The rate is deemed with including fitting arrangement as per site requirement complete. |
| 107 | S & Fin replacement 30 wattsLED building security light fittings, IP 65 luminaire, Pressure die cast aluminium housing powder coated graphite grey and toughened glass including necessary fixing arrangements as per site requirements all as specified and directed by Engr In Charge. Make : Havells/CG/Philips/Bajaj/ Luker. |
| 108 | Taking down old corroded GI bracket of 25 mm dia and supply and fixing new GI brackets of GI pipe light grade of size 25 mm dia including nuts, bolts and washers for building secufity light all as specified and directed |
| 109 | M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level connected to 4mm dia GI earth wire as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steelall as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed.NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type RCC chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mmc/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. (2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. |
| 110 | Description all as item No 99.00 above but using GI strip of size 25 mm x 4 mm wire as earth lead. |
| 111 | Repair to LEDlight /PTLs of any model/make/rating in position including testing of serviceability of connected accessories, and wiring upto respective switch/control unit including and replacing unserviceable items such as drivers , holder and making light functional.Note: (i) All the spares such as drivers, holder, LED tubes etc including replacing will be will measured and paid separately (ii) The representative of the contractor shall report to Engineer-in-charge/JE on daily basis to carry out repairs to light fitting and completion report to be submitted all as specified and as directed. |
| 112 | S & Fin replacement of PVC insulated copper conductor cable of following sizes, 1100 Volts grade, Heavy Duty, served with inner sheathing (flexible) industrial cable complete all as specified. |
| 113 | 4.0 sqmm single core |
| 114 | 6.0 sqmm single core |
| 115 | 1.5 sqmm single core |
| 116 | Removing and refixing the following during Addn/ Altn/ modification of existing structure:- |
| 117 | Light fixture/ switch socket outlet of any type and any capacity. |
| 118 | Ceiling Fan/ Exhaust Fan of any sweep. |
| 119 | Split Air Conditioner of any capacity. |
| 120 | S & Fin replacement of only electronic drivers for 10 to 24 watt LED post top luminaire / LED light fittings operated at input AC voltage 85 to 265 Volts, 50Hz,output DC voltage 42 to 65 Volts, 300MA, P.F > 0.95 incl necessary fixing arrangment as per site requirement complete all as specified and as directed. Make : Philips/ CG/ Havells/ Bajaj. |
| 121 | S & Fin replacement of 7 Watts holder type(E22) LED lamp (E22) 230 Volts, 50Hz complete all as specified and as directed. Make : Philips/ CG/ Havells/ Bajaj |
| 122 | S & Fin replacement of 7 Watts retrofit holder type (E27)LED lamp 230 Volts, 50Hz complete all as specified and as directed. Make : Philips/ CG/ Havells/ Bajaj |
| 123 | M&L for Repair to point wiring for light/fan/socket by cutting, removing and replacing the burnt and unserviceable wire with new FRLS cable and conduitswith copper conductor 1.5/2.5 Sqmm size, jointing with same size wires, replacing the saddles, refixing the loose/hanging conduits/casing cappingproperly all as directed. Note:(i) Rate is inclusive for FRLS cable and other minor items (ii) The representative of the contractor shall report to Engineer-in-charge/JE on daily basis to carry out repairs and completion report to be submitted all as specified and as directed |
| 124 | M&L for taking down of unsv /damaged Casing & caping of size 25 mm x12mm from its existing location and s & f in replacement of the same alongwith connected accssories ,fixing with the wall, roof etc as specified and directed by Engr In Charge. |
| 125 | Description all as per item No 108.0 above but Conduit pipe of 25 mm dia. |
| 126 | Supply and fixing with wall, piller, wooden structure etc. UPVC Panel Trunking of size 60 mm (H) x 50 mm (W) for running of wire, cable of any type etc complete all as specified and directed by Engr In charge. Make :- Precision or equivalent to Supreme . |
| 127 | S & F in replacement of modular white cover plate with farme suitable for 3 module, refixing with the existing /new switches all as specified and directed by Engr In Charge. |
| 128 | Description all as per item no 111.00 above but suitable for 4 module. |
| 129 | Description all as per item no 111.00 above but suitable for 6 module. |
| 130 | Description all as per item no 111.00 above but suitable for 8 module.Note : for item No 111.00 to 114.00 : The new modular switch/sockets required will be measured and paid separately under relevant item of this schedule. |
| 131 | Supply and fixing in replacement ofAir termination, single pointed aluminium rod 12mm dia and 300mm long. Complete all as specified and directed. |
| 132 | Supply and fixing in replacement of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw. Complete all as specified and directed. |
| 133 | Supply and fixing in replacement of Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground. Complete all as specified and directed. |