| 1 | PCC Poles |
| 2 | PCC Pole 9 mtrs long (400 KG) |
| 3 | PCC Pole 9 mtrs long (200 KG) |
| 4 | Outdoor 11 KV O/D VCB KIOSK complete with accessories including use of special tools |
| 5 | Armoured Cable of size 2C X 4 SQ.MM. 1100 Volts PVC Insulated including supplyof ferrules |
| 6 | Control Cable of size 12C X 2.5 SQ.MM. 1100 Volts PVC Insulated including supply of ferrules |
| 7 | Overhead steel cored aluminum ACSR DOG[100SqMM(6+7) /(4.72+1.57)] conductor complete in all respect as per latest specification and drawing |
| 8 | Overhead steel cored aluminum ACSR Rabbit conductor in all respect |
| 9 | Earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length with GI wire and clamp as per latest specification and drawing adopted & approved by NIGAM. |
| 10 | MS earthing rod 20mm dia, 3 meter long for substation earthing |
| 11 | CTPT structure Set (Galvanized) |
| 12 | 11KV CT PT Set(200/5 Amp.) |
| 13 | MIP meter box for meter with TTB |
| 14 | GI Nut & Bolt assorted Size |
| 15 | GO double break without EB Isolator on existing bracket complete in all respect as required including hardware, nut, bolts & washer etc. |
| 16 | 11KV ( with 9 x 24 KV Post Insulator ) 400 Amp. |
| 17 | Horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc. |
| 18 | 11KV ( with 6 x 24 KV Post Insulator ) 1 Set=3 NOS |
| 19 | Supply of Insulators |
| 20 | 11KVPorcelain Disc.insulators B&S type 45KN |
| 21 | Hardware for 11KV disc insulator B&S type 45KN |
| 22 | Composite Polymer insulators |
| 23 | 11KV Polymer Disc.insulators T&C type 45KN |
| 24 | Hardware for 11KV disc insulator T&C type 45KN |
| 25 | 11 KVcomposite polymer Pin Insulator complete in all respect |
| 26 | PG clamps for suitable ACSR DOG Conductor |
| 27 | PG clamps for suitable ACSR Rabbit Conductor |
| 28 | 11 KV Danger plate of size 200 X 250 mm complete in all respect |
| 29 | Supply of Angle and Channel |
| 30 | M.S Channel 100x50x6 mm |
| 31 | M.S Channel 75x40x6 mm |
| 32 | M.S Angle 65x65x6 mm |
| 33 | M.S. Flat 50 X 6 mm (Galvanized) |
| 34 | 1.4 Mtr Channel bracket with clamp |
| 35 | Supply of Lightening arrestors |
| 36 | Substation type 9KV, 10KA station class (1Set=3 Nos.) lightening arrestors. |
| 37 | 11kV Double pole line structure set for cut point complete on existing poles in all respect with clamp, as required made from M.S.Channel 100 X 50 X ISMC ( 9.56 KG. PER MTR.) ISA M.S.Angle 65 X 65 X 6 MM, M.S.Angle 50 X 50 X 6 MM AND M.S.Flat 50 X 6 MM(Galvanized as per IS) |
| 38 | GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, |
| 39 | Strain/Guy insulator for stay set |
| 40 | 7/10 SWG GI Stay Wire |
| 41 | GI Wire 8SWG |
| 42 | UNDERGROUND CABLE FOR WORKING VOLTAGE OF 11KV ALUMINIUM CONDUCTOR (IS 7098) CABLE XLPE ARMOURED |
| 43 | Under ground Cable of Size 3X185 SQ.MM for 11 KV |
| 44 | G.I. PIPE OF 125 MM DIAMETER, B-CLASS (IS:1239 MARK) |
| 45 | GI PIPE for Cable Support at Pole ( Each 3.3 Mtr ) |
| 46 | CABLE FOR11 KV ALUMINUM CONDUCTOR XLPE ARMOURED HT CABLE |
| 47 | XLPE 3X185 SQ.MM H.S. ON OUTDOOR TYPE |
| 48 | XLPE 3X185 SQ.MM H.S.S.T. JOINT |
| 49 | 11.4 MTR. Long lattice tower made of 50 X 50 X 6 MM M.S. angle with 50 X 6 MM M.S. FLAT for bracing as per nigam specification |
| 50 | 11KV Cross Arm with Top Hamper with clamps made of MS Angle 65x65x6mm, clamp 50X6 mm, earth clamp 50X6 mm (Galvanized) |
| 51 | Fixing of 11/0.4 KV SubStation structure set for Three Phase 25 KVA transformer on double poles in all respect.weight(As per Specification and Drawing without GO channel) of Approx=166.67 kg (All galvanized as per relevant IS) |
| 52 | Fixing of 11/0.4 KV SubStation structure set for Three Phase 63 KVA transformer on double poles in all respect.Weight (As per Specification and Drawing with GO channel) Approx=219.54 kg (All galvanized as per relevant IS) |
| 53 | 11 /0.4 KV Al wound, Three Phase Distribution Transformer |
| 54 | 25 KVA (Completely self protected with provision of LT Bushing Box) |
| 55 | 63 KVA |
| 56 | 6.35/0.24KV S/S structure set for single phase transformer on single 9Mtr, 400KG PCC pole in all respects. |
| 57 | 11KV 100 Amp drop out cum isolator with 3.0 Amp. Fuse & 12 KV Post insulators. |
| 58 | LT XLPE Cable |
| 59 | Size 4CX70 SQ. mm |
| 60 | Size 4CX120 SQ. mm |
| 61 | Aerial Bunched Cable |
| 62 | Aerial Bunched Cable 1Cx25+1x25 Sqmm |
| 63 | Aerial Bunched Cable 3Cx25+1x25 Sqmm |
| 64 | Aerial Bunched Cable 3Cx50+1x35 Sqmm |
| 65 | LT Distribution pillar Box200A |
| 66 | Dead end (anchor) clamps for insulated or bare messenger + one Pole Bracket + 1.5 mtr S.S. (Stainless Steel) Strap + two SS Buckles as per NFC Standard suitable for AB Cable Complete in all respect (galvanized as per IS) |
| 67 | Suspension (anchor) clamps for insulated or bare messenger + one Pole Bracket + 1.5 mtr S.S. (Stainless Steel) Strap + two SS Buckles as per NFC Standard suitable for AB Cable Complete in all respect (galvanized as per IS) |
| 68 | LT insulation piercing connectors NFC Type A (main to tap) (main 16-50 mm2, Tap off 2.5-16 mm2) |
| 69 | LT insulation piercing connectors NFC type B ( main to main) (size 16-50 mm2) |
| 70 | LT Bracket with clamp 600mm (2Ft) |
| 71 | LT Shackle Insulator with hardware |