Power Government Departments Closing in 0 days TDR #49514195

Tender For Renovation Of Control Room Building, Switchyard And Boundary Wall And Construction Of Fencing And Control Cable Trench Along With Allied Civil Work Of Dinhata 33/11 Kv Substation Under Dinhata Division Wbsedcl

Issued by Government Departments · dinhata, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
18 Jun 2025
0 days left
EMD
56540
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
dinhata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Renovation Of Control Room Building, Switchyard And Boundary Wall And Construction Of Fencing And Control Cable Trench Along With Allied Civil Work Of Dinhata 33/11 Kv Substation Under Dinhata Division Wbsedcl

BOQ

Name of Work: Renovation of control room building, switchyard and boundary wall and Construction of fencing and control cable trench along with allied civil work of Dinhata33/11 KV substation under Dinhata Division WBSEDCL
Sl. No. Item Description
1Dismantling all types of masonry excepting cement concrete, plain or reinforced, stacking serviciable materials at site and removing rubbish as directed within a lead of 75.00 metre.a) In Ground Floor including roof ground floor
2Dismantling RC Floor, Roof, Beams etc. including cutting rods and removing rubbishas directed within a lead of 75.00 metre including stacking of steel bars.a) In Ground Floor including roof
3Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.In ground floor including roof.(a) upto 150 mm. thick
4Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm.
5Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation.
6Filling in foundation or plinth by silver sand in layers not exceeding 150 mm. as directed and consolidating same by thorough saturation with water ramming complete, including the cost of supply of sand. (Payment to be made on measurement of finished quantity).
7Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
8Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm. nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes.b) River bazree.
9Screed concrete on roof with cement concrete (4:2:1) including admixture of damp proof materials as per manufacturers specification laid in panels as directed including cleaning, chipping and applying cement sluury @ 1.75 Kg/SqM. Providing ghoondies at junctions with parapet etc. shapping and finishing at mouths of rainwater pipes complete with top finishing with cement punning not more than 1.5mm thick , curing complete as per direction of Engineer-in-charge.[Artificial Stone Flooring (Sl. no. 3 at Page no. 41) minus Neat Cement Punning (Sl.15 at Page no. 192)= Rs. 344.00 - Rs. 34.00 = 310.00].Average 35 MM thick.
10Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer\"s specified rate) for concrete of various grades.
11Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips(20 mm.nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes.River bazreei) In ground floor and foundation.
12Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor).(f) 25mm. to 30mm. shuttering without staging in foundation etc.
13Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bennding to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation, basement and uptoroof of ground floor / upto 4m.(i) Tor steel/Mild steel In Ground Floor and Foundation.II)JSW/JSPL/SHYAM/SRMB/BMASL/ELECTROSTEEL/SSL
14Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc.NOTE: Cement 0.152 cu. M. per sq.m.
15Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.
16(II) Cement concrete with 30 mm down graded shingles excluding shuttering.N.B. VarietyIn ground floor and foundation.(A) Stone metal.(a) 6:3:1 proportion
17Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth
18(b) In superstructure, ground floor
19125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. i)In super structure ground floor.
20Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.](i) With 1:6 cement mortar(c) 15 mm. thick plaster.For Outer walls.In ground floor.
21(b) 20 mm. thick plasterInternal wallIn ground floor.
22(iii) With 1:4 cement mortar(c) 10 mm. thick plasterFor Ceiling Works.In ground floor.
23Stripping off worn out plaster and raking outjoints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directe
24Removing loose scales, blisters etc. from old painted surface and thoroughly smoothening the surface to make the same suitable for receiving fresh coat of paint.
25Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)Ground floor
2618 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]
27Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame excluding cost of concrete, Iron Butt Hinges and M.S. clamps. (The quantity shoud be corrected upto three decimals).(d) Sal : Local.In ground floor.
28Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood vveneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.(a) 35mm thick shutters (single leaf)1)In Ground floor.
29Supplying, fitting and fixing M.S. clamp for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction.(c) 40mm. X 6mm, 125mm. Length.
30Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete.(iii) 300mm x 16mm dia. bolt.
31Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed withcadmium plated screws:(vii) 100 x 75 x 4.0mm.
32Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal/ Round rod)(ii) 100 mm grip x 10 mm dia rod.
33Providing and fixing PVC Door Frame of size 50x47mm with a wall thickness of 5mm (± 0.2 mm) made out of single piece extruded PVC profile, with mitred cut joint sand joint with 2 nos. of PVC bracket of size 190 mm x 100 mm long arms ofcross section size 35 mm x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The doorframe to be fixed to the wall using 8 x100mm long anchor fasteners complete, all as per manufacturer‟s specification and direction of Engineer -in- charge.
34PVC Door Shutter-30 mm thick:Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of 59 mm x30 mm section with 2.0 mm (+/-0.2 mm) wall thickness.Horizontal & vertical section shall be fixed to each other by self tapping screws and 1 solid polymeric or M.S. galvanised tubular \"L\" shaped bracket 100mm x 200mm in each corner of the shutter frame for placing hinges.Polymer based multicavity hollow section of 120 mm x30mm with 2.0 mm (+/- 0.2 mm) wall thickness will be fitted in the middle, reinforced by solid polymer bar of 200 mm long at both ends and screws from both sides as lock rail. The section frame will then be fitted in by PVC panels of size 100 mmx25 mm with wall thickness of 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials, labour, and hire of tools and plants and appliancesi/c carriage of all materialstaxes and all other incidental charges complete.
35Applying Exterior grade Acrylic Primer of approved quality and brand on plastered or concretesurface old or new surface to receive decorative textured (mat finish) or smooth finish acrylic exterior Immersion paint including scrapping and preparing the surface thoroughly, complete as per manufacturer\"s specification and as per direction of E.I.C(ii)One coat on new surface.In ground floor.
36Protective and decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required.The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.(a) Normal Acrylic EmulsionIn ground floor.
37Applying Interior grade Acrylic Primer of approved quality and brand on plastered or concretesurface old or new surface to receive distemper/Acrylic emulsion paint including scrapping and preparing the surface thoroughly, complete as per manufacturer\"s specification and as per direction of E.I.C(ii)One coat on new surface.Water based interior grade Acrylic primerGround floor
38Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats)i) Standard QualityGround floor
39Priming one coat on timber or plastered or surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.)
40Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.)
41(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary.(a) On timber or plastered surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
42(b) On steel or other metal surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
43Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials.(i) CPVC Pipes Class-1, SDR-1115 mmFor Exposed Work15mm
4420 mm
4525 mm
46Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.A) UPVC Pipes:(ii) 110 mm. Dia.
47B) UPVC Fittings: For Exposed Work ( Rain water Pipes ).a) Plain Tee, 110 mm dia
48b) Plain Y, 110 mm dia
49c) Bend 87.5 degree, 110 mm dia
50d) Shoe, 110 mm dia
51Preparation of drainage spout on roof for bituminous waterproofing treatment after required grading and shaping of the under bed with Cement Concrete (1:2:4) or Cement Mortar (1:4) as directed, Chamfering and moulding the parapet wall to form a bell mouth entry, if required and providing full course treatment with bituminous felt to facilitate quick and smooth drainage of watwr into the down pipes complete including cost of all materials and labour according to satisfaction of the Engineer - in - Charge
52Supplying, fitting and fixing bib cock or stop cock.(a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
53(b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
54Supplying, fitting and fixing pillar cock of approved make.a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
55Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specificatioons with P.V.C. fittings completre, C.i. brackets including two coats of painting to bracket etc.
56Refixing wash basin with brackets with or without waste fittings
57Supplying, fitting and fixing Waste fittings complete.(ii) 32 mm
58Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only)a) 40mm dia.
59Supplying, fitting and fixing windows and ventilators with or withoutintegrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.In Ground floorFlash butt welded windows and ventilators(No shop priming will be allowed to facilitate inspection ofworkmanship)Without integrated grills.(a) Fixed type steel windows as per IS sizes with horizontal glazingbars.
60(b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only]
61(iv) Two point nose steel handle including fitting and fixing.
62(vi) steel peg stay 300 mm long including fitting and fixing.
63Easing and oiling, cleaning collapsible gate and repairing tolocking arrangements.
64Labour for taking out steel door and window frame for repairs and re-fixing the same (or replacement by new one) including mending good damages (excluding the cost of repair of damages) and applying a protective coat of paint.Upto one sq.m.area of frame
65Renewing hinge of steel shutter including taking out old one by cutting and fixing new hinges by welding and mending good damages complete
66Renewing steel plated or oxidised casement stay or peg stay of steel window frames including painting two coats with approved paint complete
67Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall)(i) 3 mm thick (weighing 7.4 kg/Sq.m)
68Renewing worn out putty of glass panes :b) Panes exceeding 0.2 Sq.m but not exceeding 0.5 Sq.m
69Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.(c) 300mm long.
70Taking out old damaged tarfelt from the roof, parapet etc. preparing the roof surfaces by removing all spoils, blisters, moss etc. from the working site and disposal of the same beyond the compound and cleaning the site in all respect asper direction of Engineer-in-Charge.
71Application of priming coat for standard bituminous waterproofing treatment over flat roof with Bitumen primer of approved brand fufilling the provision of I.S. 1346 - 1991 & 3384 - 1986 applied @ 0.27 Liters /Sq.m. over clean and prepared roof surface complete as per satisfaction of theEngineer - in - Charge.
72Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturer\"s specification on smooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage,complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.).Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N: 300 (longitudinal), 200 (transverse) (Ref: Sl. No. 97 of (U) Additional Items, Page no. 302 of PWDSOR for Building works w.e.f. 01.12.2015)
73M.S structural works in columns ,beams etc.With simple rolled strual members (e.g. joists, angle, channel sections conforming to IS:226, IS:808 & SP (6)1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in charge complete including cutting to requisite shape and length, fabrication with neceassry bolting metal arc welding conforming to IS:816-1956 and IS:1995 using electrodes of approved make and brand conforming to IS:814-1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.I) For structural members of specified sections weighing less than 22.5 Kg./m
74Labour for picking up existing gravels spreaded withinthe switchyard to an averagedepths upto 100mm including screening,washing the gravels and cleaning the switchyard from plants,jungle,shrubs,mud,slurry etc. and stacking the same for re-spreading within a lead of 75 meter within the sub-station area.Including Respreading the same gravels over Plain cement concrete in the switchyard premisesto an averagedepths upto 100mm.
75Supplying gravels/ shingles of North Bengal Variety and stacking at site including cost of materials, carriage, loading, unloading all complete including all taxes and duties and incidental charges as per direction of Engg-In- Charge
76Labour for spreading gravel shingles around the sub-station structures in the switchyard premises in uniform thickness of 100 mm including carriage of materials from the stack as per direction of Engg-In-Charge.
77Supplying, fitting galvanised 3 ply 12 gauge / 4 points line of barbed wire in fencing (holes already made in the body of the post) or fixed by staples tightening and fixing the wires in taut condition with straining bolts including the cost of cutting and of lapping joints in the wire as necessary but excluding the cost of galvanised staples,straining bolt and binding wire where necessary.
78Supplying P.V.C. water storage tank of approved quality with closed topwith lid (Black) - Multilayer1000 litre capacity
79Labour for hoisting plastic water storage tank.(i) Upto 1500 litre capacity.(a) Upto 1st story from G.L.
80Labour for punching hole in plastic water storage tank upto 50 mm dia.
81(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq.mtr.1)In Ground floor.
82Spplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified color / natural) matt finished conformating to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work).(A)In 10-12 Micron thickness Annodizing film1) Natural whiteg) Fixed Glazingi)Top,bottom and side member
83ii)Mullion
84iii)Glazing clip
85k) Movable door shutter.i) Door frame. (Top & sides).
86ii) Shutter :Top rail.
87Bottom rail.
88Lock rail
89Door vertical.
90Glazing cleap.
91Labour charge for fabrication and installation of composite door, window, partition made from extruded alloy aluminium sections for the following units:-(B) Partly glazed partly panelled or fully glazed single leaf alunminium swing door made of extruded and annodized alloy aluminium sections, fabrication including cutting to proper shape and size, drilling and aligning, fitted with heavy duty hydraulic action floor sping placed in the floor with mending damages,with top pin assembly of approve make and brand, fitted with in built locking arrangement, flush bolt, glazing clips and all other necessary fittings, fixtures, dhesives and joineries, cutting glass of approved make to requisite shape and size fitting with dry set neoprene or EPDM gasketing, cutting to requisite shape and size panel board (prelaminated particle block) fixing them with glazing clips as per drawing, specification and direction of Engineer in charge.The rate includes the hire charge of all tools and plants, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded alumium sections, glass, panel boards neoprene / EPDM gasket, locking arrangement, weather gasket / wool pile, floor spring, top pin, handle, tower bolt, glazing clips etc. (10% rate reduction has to be made for swing doors or partitions where floor sping is not used. 10% enhancement of rate is to be made where door frame of extruded aluminium sections has to be fitted and fixed to masonry wall. 5% rate enhencement may be allowed for double leaf swing door. Payment shall be made for the shutter area only exept where door frame is fixed the entire opening shall be taken to consideration. Payment for door frame sections are to be paid seperately).For Double leaf swing doorIn ground floor(wall)
92Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.iii) 5mm thick clear glass.
93Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge.iii) weather gasket / wool pile for door vertical.
94b) \"U\" shaped EPDM gasket for frames.
95(ii) Door stopper (Anodised aluminium)
96Supplying heavy duty hydraulic double action floor spring along with top pin/set of pivots conforming to IS: 6315 or any approved make as per direction of Engineer in charge.
97Supplying 4 lever mortice lock or anyapproved make and brand as per direction of the Engineer- in -charge.I) 100 mm.
98Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP)(a) 3mm thick (0.25mm Al.+2.5mm LDPE +0.25mm Al. PVDF coating)
99M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.
100Bottom curved rail of M.S. flat with necessary clamps under the curved M.S.flats and fixing them after cutting holes with cement concrete (1:2:4) with stone chips and mending good damages to run smooth the heavy iron gated door or G.C.I. Sheet door or gate. (i) 50mm x 6 mm M.S. flat
101W.I. or M.S. wheel or roller of steel door or gate fitted and fixed with neceessary clamps and nuts and bolts and erected complete.(i) Above 50 mm.
102Supplying, fitting and fixing Fan Hook for ceiling with 1 metre long 16mm.dia rod complete including mending damages. Payment for damage andrepair to be made separately

AI Tender Summary

OUR REF NO 49514195
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 18-06-2025
Authority
Authority Name West Bengal State Electricity Distribution Company Limited
Work Description Renovation Of Control Room Building, Switchyard And Boundary Wall And Construction Of Fencing And Control Cable Trench Along With Allied Civil Work Of Dinhata 33/11 Kv Substation Under Dinhata Division Wbsedcl
Basic Detail
Tender No RM/CRO/Civil/e-TENDER/2025-26/ 07 Date 27.05.2025
Bidding Type Tender
Location
City dinhata
State West Bengal
Key Dates
Publish Date 04 Jun 2025
Submission Date 18 Jun 2025
Open Date 20 Jun 2025
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 56540
Exemption Not Available
Document List
4ffd9052-058e-4036-9ac8-bd758c0de0f1.html
BOQ_1908879.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 04, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 18, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 20, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

4ffd9052-058e-4036-9ac8-bd758c0de0f1.html

xls

BOQ_1908879.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail