| 1 | S&Fof 100 Amp. 415 V metal clad TPN HRC type switch fuse unit complete with HRC fuse on angle iron bracket complete in all respect. PWD SOR 2018 S.I. No. 328 Cat-B |
| 2 | S&Fof 63 Amp. 415 V metal clad T.P.N. rewireable type switch fuse unit on angle iron bracket complete in all respect. PWD SOR 2018 S.I. No. 316 Cat-B |
| 3 | Supply & fixing of75 mm x 90 mmshackle insulator /100 mm x 65 mm pin insulator including G.I. Bolts / spindle nuts etc. complete in all respect. PWD SOR No. - 620 / 2018 |
| 4 | Supply & erection of \"D\" clamps of 50 mm x 6mm flat iron on steel tubular poles / steel rail poles with bolts, nuts etc. complete in all respects including painting with aluminium paint . PWD SOR No. - 623 / 2018 |
| 5 | S/E of 35Sqmm. Single core aluminium conductor serve shethed PVC insulted Conductor cable complete as per direction of E/I. (Approved rate) |
| 6 | Making suitable earthing of street light pole with 2.5 M long 20 mm dia M.S Rod with 7/16 SWG GS wire in 15 mm dia 2.0 M long GI pipe duly clamped with 2 nos. of clamps and binding on pole including cost of labour & T&P etc required for proper completion (Approved rate) |
| 7 | S/F of 40Amp. T P N capacity of automatic street light cubicle control panel painted with anticorrosive alkali and acid proof paint consisting of timer switch TSO 100 series with contractors HRC fuses, is olating switch Metreing instrument and instrument box with CTs etc in case of TPN compelete in all respect. S.I. no. 807-F PWD SOR 2018 |
| 8 | Supply of 90 to 150watt. LED fittings drivers. With 2 year warranty. (Approved rate) |
| 9 | Supply, Fixing and Tasting of PVC Covering 2 Mtr. High around the pole complete as per direction of engineer at site. (Approved rate) |
| 10 | Supply and fixing pf 90-120 W LEDchip plate complete in all respectasper direction of Engineer incharge. (Approved rate) |
| 11 | Supply and fixing of 4 sqmm 2 core flat twin \"AL\" cable complete with labour T&P an dall taxes as per direction by E/I. (Approved rate) |
| 12 | Supply and burring of safe earthing electrode T-19 Zn-Zinc coated, length up to 2000 mm., outer pipe 48.4 mm. x 3.2 mm., inner pipe 26.9mm.x2.6 mm., terminal dia. 12 mm., coating 80-100 micron filled with crystallinc conductive mixture (CCM) having anti corrosive & conductive properly with 50 kgs. activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonry housing. (From electrode terminal to switch board, cost of25x3 G.I. strip will be extra). Make : As approved in U.P. P.W.D. & C.P.R.I. certified. PWD SOR 2018 S.I. No. 725-B |
| 13 | Supply and laying of 16 sqmm 4 core aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.PWD SOR 2018 S.I. No. 501-I |
| 14 | Supply and fixing offactory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 100 to 120 Watt. Confirming to IP 65 protection complete in all respect.CAT-AAA.PWD SOR 2018 S.I. No. 1453 |
| 15 | Repairing of PVC Covering. (MR) |
| 16 | Supply & errection of overhead line with G.I. wire no. 8to 4 SWG including binding etc. complete in all respect PWD SOR 2018 Si. No. 628 |
| 17 | Supply of skilled electrican with tool-kit . (Approved rate) |