Tender For ATF FACILITIES AT ARMY UNIT TUTING, DISTRICT - UPPER SIANG, ARUNACHAL PRADESH--TANK INSTALLATION & GUARD WALL 2 INTERNAL PAINTING OF PRODUCT TANKS (FOR ATF TANK)INZONE- A and ZONE- B :FIRST TIME PAINTING/FULL RE-PAINTING Applicable for ATF Storage Tank; painting area as per IOCL specification Note : 1. Application for External / Internal painting for all product tanks shall be carried out by means of AIRLESS SPRAY PAINTING SYSTEM only. 2. The item rates for above should include provision of double staging scaffolding with MS pipes, drawing to be approved by Site-Engineer. i. Surface Preparation as per SA 2½ ii. Primer : P2- Polyamide cured Epoxy Zinc Phosphate - Single Coat, DFT 70-75µ iii. Intermediate Coat : P5- Epoxy Zinc Phosphate - Single Coat, DFT35-40µ iv. Finish Coat : F3- Amine adduct cured HB Epoxy Liner - 2 Coats (100-125µ each), DFT 200-250µ Total Min DFT 305µ 3 Transportation of equipmentfrom one location to another location including enroute all taxes, leviesand unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank sameshall be loaded by the tank fabricationcontractor) 4 iii) 15/20 KL Tank with fittings : 0 - 30 Km 5 iv) 15/20 KL Tank with fittings: Add extra for each addtnl. Km above 30km 6 Loading/unloading charges for 10/15/20/ 50/70 KL tanks. 7 ii) Loading/unloading charges for 15/20 KL Tank 8 Installation of supplied 20 KL Tank as per specified drawings as per work description but excluding all works of kerb wall and Gasket for manhole including painting / doping with Shalimastic HD as applicable as per specifications complete. RCC works wherever mentioned shall be of grade M20 9 ii) In earth pit with RCC matt raft as per standard Drg. ENG/314 10 Conversion of MS/HSD tanks into ATF tanks by fixingfollowing fittings 11 Modification of MS/HSD tank into ATF tank by S/F SS SAMPLING POINTS, SS SUMP, SS NOZZELS, SS DIP PLATE & PIPE Etc As Per IOC approved Drawing. 12 Supply & Installation of 100 mm dia SS floating suction assembly (installation as per OEM provided drawing) with SS float, SS swivel joint, SS Arm, SS flange of class 150#, ANSI B16.5 and all other components of SS, testing pressure 5 Kg/Cm2, all complete as perspecifications including packing, forwarding, insurance, and third party inspection, loading, unloading, transportation and stacking at site, , all complete as per specifications. Note :Test Certificate of the manufacturer & TPI report shall be required to be submitted at the time of supply. Note: IOC approved OEM are 13 SUPPLY/INSTALLATIONOF 80MM DIA SS GUAGE HATCH FORATF TANKS As Per IOC approved Drawing 14 SUPPLY /INSTALLATION OF SS VENT HOOD 80 MM DIA FORATF TANKS As Per IOC approved Drawing 15 GUARD WALL & TANK TOP CONCRETING 16 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: 17 vi) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 40mm) 18 Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level 19 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm 20 Centering and shuttering including strutting, propping etc. and removal of form for : 21 iv) Lintels, beams plinth beams,girders bressumers and cantilevers 22 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels 23 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 24 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth 25 i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand)IN FOUNDATION AND PLINTH 26 Providing and laying cement plaster on surfaces with fine sand including curing etc. 27 iii) 15mm Cement plaster of mix 1:4 (1 cement: 4 fine sand) on rough side of half or single brick wall 28 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: 29 iv) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 40mm) 30 Finishing walls with textured exterior paint of required shade (2 or more coats applied @ 3.28 ltr/10 sqm, over and including priming coat of exterior Primer applied @ 2.20kg/10 sqm) 31 TANK ACCESSORIES 32 Supply/Layingof 80 mm Dia SS Pipe confirming to material ASTM A312 TP 304 , SCH 40 Seamless with plain end confirming to dimension ASME B36.19 33 S/Fabrication of SS SORF flange # 150,80 mm Dia 34 Supply of 90 Degree SS304 40 S L.R. Elbow (1.5D) 80mm 35 Supply, fabrication, laying and testing of MS, BLACK, ERW, Welded pipes, heavy class conforming to IS 1239, PART I as per IOCL Specifications including pipeline fittings like bends, tee etc as required and as directed for Above Ground pipeline including surface preparation according to standard SSPC ST2 and painting with 2 coats of red oxide zinc phosphate primer and 2 coats of Synthetic enamel / aluminium finish paint as per IOCL specifications 36 ii) S/L Threaded A/G HD MS Pipes of 80 mm dia with fittings,Painting 37 Painting of AG & UG Pipeline 80 mm Painting Specification for AG & UG GI piping i. Surface Preparation as per St-2 ii. Primer : Etch Primer : Single Coat iii. Primer : P4 - Self Priming HB Epoxy Mastic Coating : One Coat : DFT 100-125µ iii. Finish Coat :F1-Two Pack Acrylic Poly-Urethane(PU) : Single Coat: DFT-40-50µ iv. Total Min DFT 200µ 38 PUMPING MODULE INSTALLATION 39 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 40 ii) Ordinary rock 41 i) All kinds of Soil 42 Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks 43 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: 44 vi) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 40mm) 45 Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level 46 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm 47 Centering and shuttering including strutting, propping etc. and removal of form for : 48 iii) Suspendedfloors,roofs,landings,balconies, access platform and Shelves (Cast in situ) 49 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels 50 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 51 INSTALLATION OF ROTATING EQUIPMENT (PUMP/ MIXER/COMPRESSOR/TURBINEETC.)(INCLUDING HEAVY EQUIPMENT CHARGES) 52 Transportation of rotating equipment with drives (including all types of pumps/mixers/compressors/turbines etc.) and accessories from owners storage points to work site, assembly of parts/sub-assemblies, installation of base plates for foundations, placing the equipment on prepared foundations, levelling with machined and tapered metallic wedges and tack welding grouting, carrying out alignment, trial runs and startup runs and providing manpower for testing, rectifying and defect and completion of works in all respects including earthing protection by way of fixing strips and electrodes as per drawings and specifications. 53 Supply & installation of catherine type Hose Reel for mounting/winding 50mm aviation hose of minimum length 20 mtr. as per EI-1529 54 Supply and Installation of 50 mm dia Aviation Hose Pipe as per IS 5797 without end connections 55 Supply and installation of end connections (both sides) for 50mm aviation hose 56 Supply and fixing of underwing Nozzle 2.5 inch dia with adopter (parker type), as per IOC approved specs and OEM 57 Supply and fixing of overwing Nozzle 1.5 inch dia with adopter (parker type), as per IOC approved specs and OEM 58 Supply and Installation of 80 mm dia Aviation Hose Pipewith end connections for TT decantation 59 REFUELLER DECANTATION/TOPPING UP SHED 60 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 61 ii) Ordinary rock 62 i) All kinds of Soil 63 Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks 64 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: 65 vi) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 40mm) 66 Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level 67 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm 68 Centering and shuttering including strutting, propping etc. and removal of form for : 69 i) Foundations,footings,bases of columns, etc. for mass concrete 70 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels 71 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 72 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: 73 Steel work in built up tubular (round,square or rectangular hollow tubes etc) trusses etc. including cutting,hoisting fixing in position and applying a priming coat of approved steel primer, including welded and bolted with special shaped washers etc. complete. 74 i) Hot finished welded type tubes 75 Providing and fixing Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of Cold rolled steel confirming to IS:513-2008 of base metal thickness 0.50 mm, having Yield Stress of Min. 275 MPa. Steel surface shall have hot dip metallic coating of Al-Zinc alloy comprising 55% Alluminium, 43.5% Zinc and 1.5% Silicon as per the ASTM-A792M, with total mass of coating on both sides shall be 150 gms/sqm. The steel shall have organic coating with Silicon Modified Polyester (SMP) /Super Durable Polyester (SDP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns SMP /SDP paint over 5-7 microns epoxy primer) and back side 8-10 Microns SMP/SDP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.58 MM. Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m or as desired by Engineer-in-charge. 76 i) Profile Sheet for roofing 77 ii) Plain Sheet for Ridges (500 - 600mm). 78 iv) Plain Sheet for Gutter (600 mm over all girth) 79 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. 80 ii) 110 mm diameter 81 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. 82 PMCC & DG SHED 83 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 84 i) All kinds of Soil 85 ii) Ordinary rock 86 Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks 87 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: 88 v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) 89 Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level 90 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm 91 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m 92 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. 93 i) Local Fine Sand within grading zone IV 94 Providing & Laying Reinforcedcementconcreteworkinwalls (Any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level UP TO FLOOR V LEVEL excluding cost of centering, shuttering, finishing and reinforcement : 95 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm 96 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels 97 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 98 Centering and shuttering including strutting, propping etc. and removal of form for : 99 i) Foundations,footings,bases of columns, etc. for mass concrete 100 v) Columns, Pillars, Piers, Abutments, Posts and Struts. 101 iii) Suspendedfloors,roofs,landings,balconies, access platform and Shelves (Cast in situ) 102 iv) Lintels, beams plinth beams,girders bressumers and cantilevers 103 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth 104 i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand)IN FOUNDATION AND PLINTH 105 x) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement:4 coarse sand in superstructureABOVE PLINTH level & UP TO FLOOR V LEVEL 106 40mm Thick Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand:4 stone aggregate of 20mm nominal size) finished with a floating cement coat of neat including cement slurry, but excluding the cost of nosing of steps etc. complete. 107 Providing and laying cement plaster on surfaces with fine sand including curing etc. 108 iii) 15mm Cement plaster of mix 1:4 (1 cement: 4 fine sand) on rough side of half or single brick wall 109 25mm Thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade ofthe slab including rubbing and polishing complete. with baseof cement mortar 1 : 4 (1 cement : 4 coarse sand) 110 Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete 111 Finishing walls with Acrylic Smooth exterior paint of required shade (2 or more coat applied @ 1.67 ltr/10 sqm over & including priming coat of exterior Primer applied @ 2.20kg/10 sqm) 112 Finishing walls with Deluxe Multi surface paint system for interiors & exteriors using Primer as per manufacturers specifications with two or more coats applied on wall @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm 113 Painting top of roofs with residual type petroleum bitumen of grade VG10 of approved quality at 17kg per10sqm impregnated with a coat of coarse sand at 60 cudm per 10sqm including cleaning the slab surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil complete. 114 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws including fixingall complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately) 115 i) Fixed Glazing with Powder coated aluminium (minimum thickness of powder coating 50 micron) sections 116 iii) For shutters of doors, windows & ventilators with Powder coated aluminium sections including providing fixing hinges/ pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 117 Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass/stainless steel screws etc. complete as per directions ofEngineer in charge 118 i) Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side 119 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): 120 iii) With float glass panes of 8.0 mm thickness (weight not less than 20kg/sqm) 121 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. 122 i) With stainless steel cover plate 123 Providingandfixingaluminiumcasementwindowsfastenerof required length for aluminium windows with necessary screws etc. complete. 124 i) Powder coated minimum thickness 50micron aluminium 125 Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-in- charge 126 i) Powder coated minimum thickness 50 micron aluminium 127 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth 128 Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Tiles of dark shade pigment using ordinary cement 129 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. 130 i) 75 mm diameter 131 DG SHED 132 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 133 ii) Ordinary rock 134 i) All kinds of Soil 135 Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks 136 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: 137 vi) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 40mm) 138 Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level 139 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm 140 Centering and shuttering including strutting, propping etc. and removal of form for : 141 i) Foundations,footings,bases of columns, etc. for mass concrete 142 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels 143 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 144 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: 145 Steel work in built up tubular (round,square or rectangular hollow tubes etc) trusses etc. including cutting,hoisting fixing in position and applying a priming coat of approved steel primer, including welded and bolted with special shaped washers etc. complete. 146 i) Hot finished welded type tubes 147 Providing and fixing Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of Cold rolled steel confirming to IS:513-2008 of base metal thickness 0.50 mm, having Yield Stress of Min. 275 MPa. Steel surface shall have hot dip metallic coating of Al-Zinc alloy comprising 55% Alluminium, 43.5% Zinc and 1.5% Silicon as per the ASTM-A792M, with total mass of coating on both sides shall be 150 gms/sqm. The steel shall have organic coating with Silicon Modified Polyester (SMP) /Super Durable Polyester (SDP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns SMP /SDP paint over 5-7 microns epoxy primer) and back side 8-10 Microns SMP/SDP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.58 MM. Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m or as desired by Engineer-in-charge. 148 i) Profile Sheet for roofing 149 ii) Plain Sheet for Ridges (500 - 600mm). 150 iv) Plain Sheet for Gutter (600 mm over all girth) 151 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. 152 ii) 110 mm diameter 153 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. 154 25mm Thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade ofthe slab including rubbing and polishing complete. with baseof cement mortar 1 : 4 (1 cement : 4 coarse sand) 155 RCC HARD STANDING WORKS 156 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 157 i) All kinds of Soil 158 ii) Ordinary rock 159 Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mixer plant at Optimum Moisture Content, carriage of mixed material by tippers to work site, for all lead and lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface & compacting with vibratory power roller to achieve the desired density, complete as per specification & direction of Engineer-in-charge. 160 ii) With material confirming to grade-II (size 53 mm to .075 mm) having CBR value -25,Thickness as desired 161 Extraforcompaction of earth work in embankmentunder optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). 162 Supply and laying of water bound macadam of 100 mm consolidated thickness for subbase with 90 to 45 mm stone aggregate,11.2mm size screenings, chippings of stone and murrum spreading, watering and consolidating in camber with power roller complete as/specifications. 163 Supply and laying of water bound macadam in layers, each of 75 mm thick (consolidated) with 63 mm to 45 mm stone aggregate. Each layer shall be consolidated by power roller after watering, spreading chippings of stone and murrum complete as per specifications. Item includes supply of murrum 6 mm thick, watering and rolling with power roller complete with preparation of surface. Rate per Layer 164 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: 165 iv) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 40mm) 166 Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level 167 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm 168 Centering and shuttering including strutting, propping etc. and removal of form for : 169 i) Foundations,footings,bases of columns, etc. for mass concrete 170 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels 171 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 172 ELECTRICAL WORKS 173 PANEL BOARDS AND DISTRIBUTION BOARDS Supply, installation, testing and commissioning of cubicle type power and motor control centre panel fabricated out of 14 SWG sheet steel undergone 7 tank process,dust & vermin proof, floor mounting type, suitable for indoor use having cable entry from the bottom and having following specific components complete, control wiring etc. as per enclosed standard drawing. Any other components/hardware required to complete the panels but not mentioned here shall also be provided. Note: Both incomers should have mechanical interlock for proper & safe operation. The MCCB used for incomer feeder shall have short circuit, overload and earthfault protection and also shunt coil for ESD operation. The Bus Bar support shall be DMC/ SMC/Epoxy moulded. All equipment/components shall be mounted logically to have free access for maintenance, tightening of connections & visual inspection. All the metering equipment shall be Digital & mounted on the panel and size of meter shall be 96 mm x 96 mm. The Bus Bar shall be provided with heat shrunk PVC sleeves & all power terminals shall be stud type with properly shrouding to avoid accidental contact. Neoprene type gasket shall be provided at the doorof the panel. The enclosure of the Panel shall have IP52 degree of protection. 2 Nos earth terminal shall be provided at the Panel frame with extension link for earthing connections. Painting:The under surface shall be prepared by applying a coat of phosphate paint and coat of yellow zinc chromate primer. The under surface shall be made free from all imperfections before undertaking the finishing coat. After preparation of the under surface, the switchboard shall be spray painted with two coats of epoxy based final paint or shall be powder coated. Colour shade of final paint shall be RAL 7032. 174 Medium RO, Standard drawing No. ENG/IOCL/PDIL-2. List of Componets are: (a) 1 No. MCCB (3P+N) of 100 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-100A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 100 A, Manually Operated Change over switch suitable for connection of Mains supply and 30 KVA DG Set /5 KW Solar system with required No. of MCCB (100 A,35 KA,3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 100A, 35 KA with UV coilO/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 100/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KAfor supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 125 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4 (l) 9 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 3 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-3 (o) 8 Nos TP MCB of 16 A, 10 KA & 1 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement ofIOCL. 175 GENERATORS Supply and installation, testing and commissioning of air cooled Diesel Generator in Acoustic Enclosure with all necessary accessories including Control panel, residential silencer, exhaustline, fuel line, anti vibration mounting pads,diesel tank, electric starterwith battery and seperate battery chargeretc in an aquostic enclosure (70 db +/ -5 from 3 m distance) as required complete. 176 vii) 50KVA 177 Design, supply, installation, testing and commissioning of AMF panel suitable for following rating DG set(Silent type) as per specification 178 ii) 50 KVA 179 Supply, installation, testing & Commissioning of wall mounted switchboard in sheet enclosure consisting of 110 A, 4P, 50 kA, Contactor, 230V AC trip coil, START / STOP Push button, ON / OFF Indication lamp(LED), Auxiliary contactors, Power & Control Terminals. Push buttons and indication lamps shall be mounted on front door. 2 Nos. of SP 6A MCB shall be mounted on front door. MCB shall get incoming supply from incomer terminal of Contactor. Outgoing from MCBs shall be wired uptoterminals inside enclosure. The enclosure shall have 6 nos. of cable entry, 2 nos. suitable for 3.5Cx35 sq mm cable & 4 entry suitable for 3Cx2.5 sq mm cable. The work includes supply and installation of enclosure, Contactor, MCBs lamp, Push buttons, terminals, internal wiring (Contactor Make: L&T/GE/C&S/Siemens/ABB). 180 Supply and Installation of Flame Proof ESD Push Button 181 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items 182 xviii) 3.5 Core x 50 sq. mm Aluminium Cable FRLS 183 xiv) 4 Core x 16 sq. mm Aluminium Cable FRLS 184 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS 185 FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. 186 vii) 3 Core x 2.5 sq. mm 187 xiv) 4 Core x 16 sq. mm 188 xviii) 3.5 Core x 50 sq. mm 189 LIGHTING FIXTUREFLAME PROOF- BAJAJ/BALIGA/FCG/OR EQUIVALENT (TYPE NO. :LW 51125, 60W LED,FLAME PROOF ENERGY EFFICIENT LED FITTING,FCG MAKE OR EQV.) 190 AREA LIGHT POLES Supply, erection and painting of area light poles of following types including 38/50mm dia tubular arm, MS base plate, earth boss, including concrete foundation (M 15) of approx. size 0.5M x 0.5M and depth varying from 1.25M to 1.5M as per IS:2713 (Part II) and as per site condition, all complete as per site direction. Pole painting tobe done with two coats red oxide primer and two coats of alluminium paint. 191 i) S/E 7M long SINGLE ARM Pole of designation 410-SP-3, as per specifications and direction of Engineer in charge 192 Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. 193 Supplying & drawing inside the poles 3 core 2.5 sq.mm PVC insulated flexible copper conductor, fixing of junction box at the pole base (excluding supply of JB), making all connections on both ends, all complete as per specification and direction of Engineer In-charge. 194 ii) L Pole 195 Providing, fixing, testing and commissioning of FLPjunction box of approved make for cable connection/ jointing. 196 i) For cables 2.5 to 4 sqmm XLPE / AYFY 197 CABLE BRICK DUCT Providing & constructing underground brick duct 650mm below GL for laying of 3 cables of max. diameter 70mm, complete with supply and laying of sand, bricks & including Excavation and backfilling in all kind of soils 198 ii) 225 mm (16 Bricks & 0.0195 cum per Mtr) 199 Providingand laying class-B 50mm dia GI pipe for cable routing under flooring/ EB post leading including sealing both ends with jute and Bitumen 200 Supplying, fabricating and installing following sizes of perforated GI cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling and/or fix to steel/RCC columns, beams or any other structure members with MS suspenders, angles, channels, etc complete as per the direction of IndianOil 201 i) 150mm x 100mm x 2mm 202 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 203 ii) Ordinary rock 204 i) All kinds of Soil 205 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: 206 vi) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 40mm) 207 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: 208 SAFETY ITEMS 209 PROVISION OF EARTHING 210 PIPE ELECTRODE EARTH PIT - Supply, installation & testing of earth electrode with following sizes:80 mm dia, 3.8 M long heavy duty perforated GI pipe electrode(Galvanisation is 910 gms/sq. mtr.) as per IS:3043 providing suitableearth bus for interconnection, providing a mixture of salt & charcoal,making RCC/ Brick earth pit chamber with chequered plate cover as per Drwng. No. HO/ENGG/EM/1111 all complete as per specification & direction ofSite-In-charge.Item also includes Supply and fixing of Earth resistance display board of size 300 X 230 mm with 3mm thick Aluminium CompositeMaterial (ACM)/ Aluminium Composite Panel (ACP) bolted to 25 X 25 X 5 mm(with 2 bolts MS angle section, 60 cm long (minmum 200 mm embedded inground). The rate shall also include supply and pasting of UV resistantvinyl sticker having details as per Site-in-charge. 211 Supply & drawing/laying, jointing, connecting, testing and commissioning ofearth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : 212 iii) 50 x 6 mm G.I. Strip 213 ii) 32 x 6 mm G.I.strip 214 ix) 6 S.W.G. Cu. Wire 215 Providing & fixing flexible copper cable PVC insulated of 16sqmm for connecting the earth grid/earth strip with the crocodile clip i/c cost of 1 no. crocodile clip (for tanker earthing & other job) 216 Supplying & Fixing of following items for electrical safety in switch rooms/DG rooms etc 217 i) Electrical insulating mats made of PVC Elastomer 3mm Thick & 1 mtr wide near swichboards, etc as per direction of Engineer In charge. Mat should conform to IS 15652 Class A - suitable for safe working voltage of upto 33 kV. Test certificate to be provided with supply. Mats top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. Mats top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. 218 ii) 6 mm thick chequered plate on cable trench inside swtich room, DG room, earthing pit including cutting, painting, lifting hooks, etc 219 iii) Supply and fixing of shock treatment chart in English, Hindi & local language framed in glass framework. 220 iv) 11 KV grade hand gloves, ISI mark 221 Supplying and fixing of 9kg DCP portable,cartridge type Fire extinguisher of approved make,Conforming to IS15683:2006,Body Carbon Steel as per IS:513,EDD grade with no vertical weld joint on the body Neck ring of seamless mild steel tube conforming to IS 1239 part-1, Valve assembly conforming to SS 316 grade or forged brass as per IS 6912 grade FLB, Inlet and outlet siphon tubes of SS 316 grade or of brass as per IS 407, Discharge nozzle of SS 316 grade of forgedbrass as per IS 6912, 500mm long discharge hose of EDPM rubber, powder coated wall mounting mild steel bracket,stainless steel safety Pin of SS 316 grade, Dry Chemical powder ( potassium bi-carbonate & Minimum 90% of the total chemical), ISI marked CO2 Gas cartridge of 200 gms, dia of the body 175mm +/- 10mm & overall height less than 650mm.Extinguisher shall have anticorrosive treatment of phosphating by hot dipping process to thickness not less than 0.012mm both internally & externally. Epoxy polyester powder coating of minimum 50 micron to all metallic external parts with two bands of yellow colored fluorescent adhesive tape of minimum 20mm thickness of body. Finish of the paint to be PO red as per shade 538 ofIS:5 222 Supplying and fixing of 4.5kg CO2 fire extinguisher of approved make Conforming to IS 15683, portable high pressure type. Body seamless Manganese Steel, ISI marked conforming to IS 7285, discharge valve conforming to IS 324,polyethylene flat discharge horn with diffuser,1m wire braded rubber hose, powder coated wall mounting mild steel bracket,stainless steel safety pin of SS 316 grade, CO2 gas with 99.5% purity. Extinguisher shall have anti corrosive treatment of phosphating by hot dipping process to thickness not less than 0.012mm both internally and externally. Epoxy polyester powder coating of minimum 50 micron to all metallic external parts with two bands of yellow colored fluorescent adhesive tape of minimum 20mm thickness of body. Finish of the paint to be PO red as per shade 538 ofIS:5 223 Supply of Galvanised Fire buckets of 9 litre capacity, painted white inside and red outside with letters fire in black, conforming to IS 2546-1974. 224 Supplying Fire bucket stand- 4 buckets hanging arrangement 1 meter height, made of 50x50x6mm angle frame, painted with 2 coats of primer and 2 coats of Red, synthetic enamel paint. 225 Providing Earthing box for decantation (excluding 16sqmm PVC insulated copper cable & 01 no. Crocodile clip) 226 Preparation of single Line diagram - Electrical Layout 227 Preparation of single Line diagram - Earthing Layout