| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in deep; and getting out in soft/loose soil complete all as specified and directed |
| 2 | M&L forcement concrete 1:4:8 type D2 ( using 40mm graded stone aggregates ) as in foundation filling and mass concrete complete all as specified and as directed. |
| 3 | M&L forRCC1:2:4 type B1 using 20 mm graded stone aggregate in foundation , including rafts, footing , foundation beams, plinth beam , bases for column, slab for culvert etc complete as specified and directed by Engr-in-Charge |
| 4 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams in flat and similar work; vertical or to batter rough finished surfaces of concrete complete all as specified and as directed. |
| 5 | M&L for RCC1:2:4 type B1 using 20 mm graded stone aggregate in Columns, pillars, piers, posts and struts etc complete as specified and directed by Engr-in-Charge |
| 6 | Use and waste of form work to faces of sides of pillars, posts, struts, piers, columns and stanchions in flats vertical rough finished surfaces complete all as specified and directed. |
| 7 | M&L forRCC1:2:4 type B1 using 20 mm graded stone aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span etc complete as specified and directed by Engr-in-Charge |
| 8 | Use and wasteof Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams fair finished surfaces , etc complete all as specified and directed |
| 9 | M&Lfor Mild steel (TMT) bars10mm dia and over, cut to length, bent to shape required,including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and asdirected |
| 10 | M&Lfor Mild steel (TMT) bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders , cut to length, bent to shape required,ncluding cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 11 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 12 | M&L for Brickwork with Fly ash bricks, straight or curved on plan exc 6m mean radius in CM (1:4)complete all as specified and directed |
| 13 | M&L forRendering 15mm thick in CM (1:4) on fair faces of brick/concrete wall surfaces and finished the surface even and smooth without using extra cement complete all as specified and as directed. |
| 14 | Providing & Fixing of 4mm ThickAluminum Composite Panel ( ALSTONE Make) EXTERIOR GRADE ( Ten Years Warranty ) Solid Color( BLUE & WHITE )usingTray Fixing Methodon the backup Aluminum / MS structure of (1.5”x1”)AL. Rectangular Tube having 1.3 mm thick, (1.5”*1”) / (2”x1”) AL. Angle , G.I Bracket , Bolt , MS Base Plate , Hole Charges , Welding Rod , Cutting Wheel , Primer & Paint , Fasteners along with necessary Hard wares Like Screws , Pop Rivet (6x19) , Weather Silicone( WACKER WN ) ,Masking Tape Carrying & Labor Charges Including scaffoldingall complete in all respectas per specifieciation and direction of Engineer -in-Charge |
| 15 | Providing & Fixing of 4mm ThickAluminum Composite Panel ( ALSTONE Make) EXTERIOR GRADE ( Ten Years Warranty ) WoodenColor usingTray Fixing Methodon the backup Aluminum structure of (1.5”x1”)AL. Rectangular Tube having 1.3 mm thick, (1.5”*1”) / (2”x1”)AL. Angle , G.IBracket , Bolt ,MS Base Plate , Hole Charges , Welding Rod , Cutting Wheel, Primer & Paint ,Fasteners along with necessary Hard wares Like Screws including scaffoldingcomplete all as specified and directed by Engr-in-Charge. |
| 16 | S&F steel work in tubular including special shaped washer etc complte using ERW or induction butt welded tubes conforming to IS 1161-1979St grade St-240 complete all as specified and directed |
| 17 | S & Fplates(plain or chequered) FE-290 grade E-165 channels, square cut or notched(ordinary and counter shunk) forming holes, without any attachement fixed with and including nutwasher completed all as specified and directed |
| 18 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cmcomplete all as specified and directed |
| 19 | Removing excavated material exc. 1.50 km but n exc. 5 km and depositing complete all as specified and directed |
| 20 | M&L for installation ofGate water fountain, unit with toughened Glass height 8Ft, width 14ft , depth 15\" . FRP fountain fully weather proof and water proof (Colour as per direction by Engr-in-Charge) complete all plumibing work required for fountain and all electric work , Submersible pump & Power LED light to highlight the fountain at the night time with all installationcomplete all as specified and directed Make : Wave fountain |
| 21 | S&F for 3 dimentional steel letter (English) in SS golden coated on the wall size 12\" height including fixing the letters on ACP panel with complete all as specified and directed by Engr-in-Charge |
| 22 | S&F for 3 dimentional steel letter (Hindi) in SS golden coated on the wall size 12\" height with back side LED light, including background ACP box suitable size for fixing the letters in wall with complete all as specified and directed by Engr-in-Charge |
| 23 | Taking down the existing SS letter from the gate of any height without damaging it and deposited to the store yard of AGE b/R Haldia and fixing the same at location as decided by Engineer-in-Charge complete all as specified and as directed. |
| 24 | M & L two coat of synthetic enamel paint over a coat of red oxide primer on steel surfaces including preparation of steel surface width or girth exc 10cm all as specified and directed. |
| 25 | M & L for preparation of new decorated surfaces of walls Providing and applying walls with approved shade and manufacturer protective and decorative modified acrylic smooth exterior water based paint with silicon additives (two coat applied @ 5.5 sqmtr per ltr) over and including one coat of water thinable cement primer of approved brand and manufacturer on wall surface by using brush/roller, cleaning etc. including scaffolding works(Use of tubular steel scaffolding shall be mandatory for buildings over three storey high) as directed by engineer in charge complete all as directed. |
| 26 | M & L forconcealed point wiring including necessary chase cutting of wall for one light/fan/call bell point with two runs of1.5 sqmmPVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts gradecontrolled by one way switchincluding one run of 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including Rigid 20mm dia PVC conduit and making good the distrubed surfaces as per the existing complete all as specified and as directed.Note: A. Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.B. The Rate of point wiring includes the following :-(i)Copper wire(ii)PVC Conduit with accessoreis(iii) Chase cutting |
| 27 | M&L forConcealed sub main wiring with two single core PVC insulated unsheathed , 1100 Volts grade, (FR-LS) copper cable two runs of2.5 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface conduit medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade,cable one run of2.5 sqmm copperconductor and connected to common earth dolly completecomplete all as specified and as directed.Note :-(i) One run of PVC conduit, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit.(ii) Quoted rate is incluive of chase cutting, laying of conduit and making good the surface with proper plaster all as directed. |
| 28 | M & L Switch Modular type single pole, one way 6 Ampcomplete all as specified and as directed. |
| 29 | S & F Modular White cover plate with frame 8/12 Modulecomplete all as specified and as directed. |
| 30 | S & F Metal/PVCflush boxfor 8/12 module complete all as specified and as directed. |
| 31 | Supply and fixing SP 6-32 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed. |
| 32 | Supply and fixing SPN 40-63 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed. |
| 33 | Supply and fix 8 way SPN Double door DB with 200 amps rated bus bar complete with connection testing and commissioning complete all as specified and as directed. |
| 34 | Supply and fixing round shape 30 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete complete all as specified and as directed. |
| 35 | Supply,Installation,comissioningof 12W Spot Luminaire IP66 ,Mono Colour (Warm White/pure white/colour as per site requirement) with CCT options andcomplete all as specified and directed.Note: 1.The lights will be installed on the outer wall and front side of the gate quoted rate is inclusive of all labour,fixing charges.2. The rate is including of all fixing to wall, testing and connecting to the MCB/DB/driver as per site requirement. |
| 36 | Supply,Installation,comissioning of 12W - 15 W UP/DOWN Cylindrical Luminaire withIP65 Rated,with Monocolour(Warm White/pure white/colour as per site requirement) with CCT options and various beam angles . Housing features a customised base bracket for angle adjustment to illuminate desired structural elements including all accessories, connections in main LT panel box/DB box and Encased in an EMC package, and comply with CE & ROHS certifications. IP66 rated, includes a BIS & ROHS compliant power supply, lens-based design with customized lens options, and equipped with a Surge Protective Device (SPD) for added safety complete all as specified and directed.Note: 1.The lights will be installed on the outer wall and front side of the gate quoted rate is inclusive of all labour,fixing charges.2. The rate is including of all fixing to wall, testing and connecting to the MCB/DB/driver as per site requirement. |