Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #49474985

Tender For Provn Of Aluminum Partition Kitchen Cabinet And Misc Works, Repair/Maint Of Coolig Appliance And Addn/Altn To Lt Ug Xlpe Cables And Allied Works At 652 Coy Asc (Civ Gt) Imtrat Under Ge (Af) Hasimara

Issued by Statutory Bodies & Commissions/Committees · hasimara, West Bengal
Tender Value
28.50 Lakhs
Estimated cost
Bid Submission
01 Jul 2025
0 days left
EMD
57000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
hasimara → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Provn Of Aluminum Partition Kitchen Cabinet And Misc Works, Repair/Maint Of Coolig Appliance And Addn/Altn To Lt Ug Xlpe Cables And Allied Works At 652 Coy Asc (Civ Gt) Imtrat Under Ge (Af) Hasimara

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 24-Jun-2025 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-Jul-2025
2 14-Jun-2025 CORRIGENDUM TO BOQ BOQ 24-Jun-2025

BOQ

Nature of Work : COMPREHENSIVE MAINT TO CERTAIN BLDGS INCL FENCING REPAIR AND MISC WORKS, REPAIR/MAINT TO EM INSTALLATION AND REPAIR/MAINT OF WATER SUPPLY LINES INCL CHLORINATION & MISC WORK AT 652 COY ASC (CIV GT) IMTRAT UNDER GE (AF) HASIMARA
Sl. No. Item Description
1S&F powder coated aluminium frame (minimum thickness of powder coating 50 micron) for doors, windows / ventilators and partitions etc., with one or more rebates including joining cleat for fixing etc., complete all as directed and specified.
2S&F powder coated anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber, neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc., complete all as directed and specified.(Note:- Glass/ other filling material in panels shall be measured and paid separately)
3S&F powder coated coloured (minimum 15 micron) aluminium sliding window shutter frame comprising of 3 track sliding window made out of aluminium extruded section of bottom frame of weight not less than 1.175 kg/RM, top and side frame of weight not less than 0.423 Kg/RM, top and bottom rail ofshutter of weight not less than 0.336 Kg/RM, in two panel and shutter with and including 5mm thick selected quality tinted glass and third one with and including stainless steel wire mesh and overall aluminium decogrill of size 100 x 100 x 8mm as approved by GE with standard aluminium channel out side, with and including handles, cleat glazing clips, special auto lock, dry set rubber gasket, complete all as specified and directed.
4S&F 12mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination fixed with aluminium frame partition or aluminium door, complete all as specified and directed.
5S&F 18mm thick prelim wooden finished PVC plastic celluka ply for cupboard, shelf etc including all required joining accessory, complete all as specified and directed.
6S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of brass polished, complete all as specified and directed.
7S&F stainless steel concealed hinges of any colour with fixing arrangement, complete all as specified and directed.
8S&F continuous (piano) hinges, mild steel, bright finish or electrogalvanized width of flap (whwn open) 30mm, complete all as specified and directed.
9S&F ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed, complete al as specified and directed.
10S&F plain sheet glass 4.8mm thick, of any colour and glazing with and including anodised aluminium snap beading or rubber/reopen bead, fixed in aluminium frame or door frame, complete all as directed and specified.
11S&F 3 to 5mm thick ACP sheet in panels of aluminium partition, aluminium door exc. 0.5 Sqm in each pane with rubber beading, complete all as directed and specified.
12S&F floor door stopper, 150mm long of aluminiurn alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and directed.
13S&F 200mm long aluminium anodised tower bolt of extruded section, complete all as directed and specified.
14M&L for 4mm thick pre-painted E-fibre board, designer/decorative,fixed or laid/inserted to GI snap grid frame size 605x605 mm work for false ceiling hangers with 4mm to 6mm dia. G.I. (length as required) adjusting level, fixed to roof slabs/truss by means of ceilling cleats made out of G.I. flat 40 x 3mm size 60mm long and expansion hold fasteners, 12.5mm dia, 40mm long, complete all as specified and directed.
15Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backin), removing serviceable tiles to store and rubbish off the premises,complete as specified and directed.
16M&L glazed ceramic coloured tiles7 to 8mm thick each area in vertical surface 350 x 250 x 7mm/450 x 300x 7mm thick set and jointed in neat cement slurry such as skirting dados and risers to steps etc, and pointed in white or colour cement to match over and including 10mm thick rendering in CM (1:4), complete all as specified and directed.
17M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement of match the surfaces over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed.
18Taking down and servicing of split type AC of 1.5 to 2 TR capacity, any type/size/make/model cleaning and washing of condenser assembly with chemical andhigh pressure jet pump, checking and retightening of all electrical connections, replacement of nuts, bolts, screws, washers, internal wiringand refixing properly after servicing, complete all as specified and directed.Note : (i) Spare parts & gas charging shall be measured & paid seperately under respective items.
19Taking down and servicing of window type AC of 1.5 to 2 TR capacity, any type/size/make/model cleaning and washing of condenser assembly with chemical andhigh pressure jet pump, checking and retightening of all electrical connections, replacement of nuts, bolts, screws, washers, internal wiringand refixing properly after servicing, complete all as specified and directed.Note : (i) Spare parts & gas charging shall be measured & paid seperately under respective items.
20Taking down and servicing of refrigerators of 165 Ltr to 320 Ltr capacity, any type/size/make/model including replacement of unserviceable parts and cleaning, washing, condenser assembly, retighening all electrical connections, replacement of nuts, bolts, screw, washers, internal wiring, fixing properly bracket housing of capacitors and reassembling properly after repair, complete all as specified and directed.Note : (i) Spare parts & gas charging shall be measured & paid seperately under respective items.
21M&L for testing leakage of gas and replacement of damaged portion of copper pipe of any dia upto 30cm length, brazing by oxyaccetelene gas welding and good quality copper brazing rods or soldering damaged portion, flaring copper pipe, replacement of flare nut and pouring the nitrogen gas flushing to check the leakage in copper pipe lines, recharging suitable gas fully after complete removal of nitrogen gas on satisfactorily completion of leak test, reassembling and testing cooling of wholerefrigerator of any capacity/type and make, complete all as specified and directed.
22All as per item No 21.00 here-in-before but for window type AC with R-22 gas of any capacity/make/type/model, complete all as specified and directed.
23All as per item No 21.00 here-in-before but for water coolerwith R-134 gas of any capacity/make/type/model, complete all as specified and directed.
24All as per item No 21.00 here-in-before but for split type AC with R-22/134/410A gas of any capacity/make/type/mode/model, complete all as specified and directed.
25Dismantling and taking down from existing position split type AC of capacity 1.5/2 ton and refixing the same in new position including necessary cutting opening, fixing, connecting, testing andmaking good disturbed surface of old position and new position etc, complete all as specified and directed.Note : Necessary gas charging, mounting stand, drain pipe and copper tube shall be paid and measured seperately.
26Taking down and dismantling the unserviceable blower motor from 1.5/2 TR window/split AC of any type including opening all outer caseand rewinding,heat varnishing the blower motor with super enamel copper wire of suitable gauge by taking out burnt winding and cleaning the iron core, complete all as specified and directed.
27All as per item No 26.00 here-in-before but blower motor of water cooler of capacity 40 to 80 Ltr, complete all as specified and directed.
28S & F in replacement of door gasket suitable for deep freezer 300/320 ltr & 310/286/165 lty capacity refrigator, complete all as specified and directed.
29S & F in replacement of freezer including necessary capilary suitable for 165 lty capacity refrigator, complete all as specified and directed.
30S & F in repair cooling coil assy suitable for 180 to 310 Ltr capacity refrigerator, complete all as specified and directed.
31S & Ffan motor, single phase 230 Volt, 50 Hz suitable for window AC, complete all as specified and directed.
32S & F in repairharmetic sealed type compressor suitable for window AC of capacity 1.5 TR, complete all as specified and directed.
33S & F in repair rotary compressor of 1.5/2 ton capacity suitable for split type AC of any make/model 1.5TRcapacity, complete all as specified and directed.
34S & F in repairoutdoor fan motor, single phase 230 Volt, 50 Hz suitable for split AC 1.5/2.0 TR capacity, complete all as specified and directed.
35S & F in repair strainer of condenser coil set suitable for windoe type AC of 1.5 ton capacity, complete all as specified and directed.
36S & F of swing motor fot split AC fited in internal unit capacity 3 to 5 watt, 5 to 8 RPM suitable for 1.5/2.0 TR capacity with wiring kit and thimble, complete all as specified and directed.
37S & F in replacement of air filter for split AC as per sample suitable for 2.0 ton capacity, complete all as specified and directed.
38S & F in repair multi terminal capacitor (50 + 6/50 + 4mfd) suitable for split AC (stating, running and fan combined), complete all as specified and directed.
39S & Fin repair 15mm dia PVC drain pipe, medium grade, for split AC as per existing, complete all as specified and directed.
40S & Fin repair PCB for outdoor unit of invertor AC model and make as per existing, complete all as specified and directed.
41S & F in repair PCB for indoor unit of invertor AC model and make as per existing, complete all as specified and directed.
42Supply and filling of refrigerant gas R-22/32 in factory sealed cylinder, complete all as specified and directed.
43Supply and filling of refrigerant gas R-134a factory sealed cylinder, complete all as specified and directed.
44Supply and filling of refrigerant gas R-410A factory sealed cylinder, complete all as specified and directed.
45S & F in repair blower motor, Indoor unit, single phase 230 V suitable for window type AC 1.5/2 ton, complete all as specified and directed.
46S & F in repair in repair copper tube 1/4\", complete all as specified and directed.
47S & F in repair in repair copper tube 1/2\", complete all as specified and directed.
48S & F in repair in repair insulation tube 1/4\", complete all as specified and directed.
49S & F in repair in repair insulationtube 1/2\", complete all as specified and directed.
50S & F in repair in repair copper tube 5/8\", complete all as specified and directed.
51S & F in repair in repair insulation tube 5/8\", complete all as specified and directed.
52S & F in repair harmetic sealed compressor suitable for cooling capacity 40/80Ltr water cooler, complete all as specified and directed.
53S & F in repair condensor unit assembly suitable for split AC 1.5 /2 ton capacity, complete all as specified and directed.
54S & F in repair split AC outdoor mounting stand as per existing, complete all as specified and directed.
55Supply and installation 10 Mtr hot dip galvanised octagonal poles with 155mm bottom & 70mm top A/F made up of 3mm thick HT sheet alongwith base plate of size 250 x 250 x 16mm (Door with Hinge) with 4 Nos of M24 x 750mm high \"J\" type EN 8 grade Including foundation of PCC (1:3:6), & bolts along with template, complete all as specified and directed.
56Supply and fixing of 1.5m long Hot dip galvanised single arm bracket made up of 40 NB dia GI pipe suitable to mount on pole having top 70 mm A/F, complete all as specified and directed.
57M&L for PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in pole pedestal (PCC) including necessary formwork, complete all as specified and directed.
58Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
59S & F junction box made from SMC/FRP sheet ready made size of junction box 295x195x100mm with aluminium bus bar of 50Amp capacity for RYB andhalf for neutral made in suitablesize fixed inside the junction box with necessary supporting insulators fixed on hylem sheet, MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete , entire assemblyfixed to pole /Wall with MS clamp 25 X 5 mm and nuts & bolts,including MCB SP 6 Amp 10 KA 240 V - 1 No, with necessary sizecopper lugs for connecting cables from junction box to fittings, completeall as specified and directed.
60Supplying, installing, testing and commissioning ofoutdoortype LT feeder piller box made out of 3.0mm thick CRCA sheetout doortype, CPRI approved ,totally enclosed weather dust and vermin proof as per ISwith front and rear 400 Amp capacity for RYB and half for neutral and insulated with insulators,including connecting incoming and outgoing cables necessarymade out of 50 x 50 x 6mm angle iron grouted at floorabove 30cm from ground level including PCC, (1:3:6)in foundation comprising the following including taking down old unserviceble LT feeder piller box, complete all as specified and directed. Incoming :- (i) MCCB of 4 poleof capacity 160 Ampswith breaking capacity of 36 KA-01 No. Outgoing :-(i) MCCB of 4 poleof capacity 100 Ampswith breaking capacity of 16 KA-03 Nos(ii) MCB of 4 poleof capacity 32 Ampswith breaking capacity of 10 KA-04 NosNote: Cost includes necessary internal wiringfor meters, indication lamps etc and rigid bus bar connections from bus bar to MCCB terminals connectionbus to MCCB/MCB connections.
61Supply and fix in replacement for electronic Timer for 24 hrs , top mounting for all contactors (frame 1 to 4) suitable for street light, complete all as specified and directed.
62S&F 50mm bore GI pipe for fixing to street light poles, made out, medium grade bend to shape inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paint, complete all as specified and directed.
63S & F 3 corePVC insulated sheathed multistranded copper conductor cable of size 2.5 Sqmm passing through PVC conduit from junction box to fittings, complete all as specified and directed.(Note: PVC conduit shall be measured and paid seperately.)
64S & F in replacement rigid 20mm dia PVC non metalic conduit on pole with necessary bend elbow, couplers, check nuts, FI clamp 40 x 4mmpolesand nuts & bolts, PVC flexible conduit, connected to junction box to fitting etc, complete all as specified and directed.
65S & F ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity200 Amps with barrier, handle and door locking kit system and necessary connection between two power sources as per site requirement, complete all as specified and directed.
66M & L for painting steel tubular polecomplete with standard color shades in bottom of poles complete along with two coats ofpriming with red oxide and one finishing coat of synthetic enamel paint complete after cleaning the pole surface, complete all as specified and directed.Note: Colorshall be as directed by Engineerin charge during the commencement of work.
67S&F in replacement LED bollard light 10 watt with soft 360 degree light distribution, IP-65, inverted pyramid tripod type with PCC & fixing all arrangemnts, complete all as specified and directed.
68S&F of MCCB 160 Amps AC 3 pole 415 Volt 36 KA breaking capacity as per IS/IEC 60947-2with thermal magnetic releaseincluding providing new thimble / lugs of suitable size andtaking down old unserviceable one, complete all as specified and directed.
69S&F of MCCB 200 Amps AC 4 pole 415 Volt 36 KA breaking capacity as per IS/IEC 60947-2with thermal magnetic releaseincluding providing new thimble / lugs of suitable size andtaking down old unserviceable one, complete all as specified and directed.
70S&F of MCCB 200 Amps AC 4 pole 415 Volt 50 KA breaking capacity as per IS/IEC 60947-2with thermal magnetic releaseincluding providing new thimble / lugs of suitable size andtaking down old unserviceable one, complete all as specified and directed.
71S&F of MCCB 100 Amps AC 4 pole 415 Volt 25 KA breaking capacity as per IS/IEC 60947-2with thermal magnetic releaseincluding providing new thimble / lugs of suitable size andtaking down old unserviceable one, complete all as specified and directed.
72S&F of MCCB 250 Amps AC 4 pole 415 Volt 25 KA breaking capacity as per IS/IEC 60947-2with thermal magnetic releaseincluding providing new thimble / lugs of suitable size andtaking down old unserviceable one, complete all as specified and directed.
73S&F of MCCB 400 Amps AC 4 pole 415 Volt 36 KA breaking capacity as per IS/IEC 60947-2with thermal magnetic releaseincluding providing new thimble / lugs of suitable size andtaking down old unserviceable one, complete all as specified and directed.
74M&L for switch of Air break gang operated triple pole mechanically operated vertical type 12 insulators and with galvanised frame, operated from ground level including operating rod, handle locking mechanism, current carrying capacity 400Amps 11000 volts, drop outfuse including nuts bolts and washers required to fix and testing, complete all as specified and directed.
75Excavation in trenches not exceeding 1.5 metre wide and not exc 1.5 metre in depth for foundation of pole, or cable trenches etc. n. exc. 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed.
76Supply only screw driver tool kit battery powered with dual mode and LED working light (fwd - reverse button),3.7 volt for power house emergency use contains 46* 1-1/8\" bits, 6* 1-3/4\" bits, 1* Thimble & Mini Suction Cup, 6* Sockets, 1* Magnetizer, 1*Triangular Tablet, 1* Screw Storage Box, 1*Flexible Extension Bar, 1* Metal Crowbar, 1* Cleaning Brush, 1* Magnetic Extension Bar, 1* Plastic Crowbar, 1* Screwdriver Handle, 1* Straight Tweezer, 1* Curved Tweeze, complete all as specified and directed. Make : HYCHIKA or equivalent
77Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed.
78Removing of excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed.
79M&L for sand cushioning for protection of underground cable, consolidatedandcompacted with clean and dry, complete all as specified and directed.
80M&L for sub class ‘B’ old size bricks, burnt clay bricks, laid flat, dry in trenches for cable protection, complete all as specified and directed.
81Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 core including taking down old unserviceable UG cable, complete all as specified and directed.
82All as per item No 81.00 here-in before but size 150 Sqmm 4 core, complete all as specified and as directed.
83All as per item No 81.00 here-in before but size 50 Sqmm 3.5 core, complete all as specified and as directed.
84Note: An amount of Rs.21,290.00 on account of Credit Schedule for schedule \"A\" part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
85Supply and fixing energy efficient ‘LED Flood Light120 W LED luminairewith Aluminium dia cast housing, toughened glass cover with IP 66 protection, CCT 5700 K including fixing arrangment on wall/pole / surface and connecting cable up to nearest ceilign rose into flexible PVC conduit. Make : Crompton/Havells/ Surya/Philips

AI Tender Summary

OUR REF NO 49474985
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 28.50 Lakhs
LAST DATE 01-07-2025
Authority
Authority Name Military Engineer Services
Work Description Provn Of Aluminum Partition Kitchen Cabinet And Misc Works, Repair/Maint Of Coolig Appliance And Addn/Altn To Lt Ug Xlpe Cables And Allied Works At 652 Coy Asc (Civ Gt) Imtrat Under Ge (Af) Hasimara
Basic Detail
Tender No C/8883/2025-26/E8
Bidding Type Tender
Location
City hasimara
State West Bengal
Key Dates
Publish Date 24 Jun 2025
Submission Date 01 Jul 2025
Open Date 03 Jul 2025
Finance
Tender Value 28.50 Lakhs
Tender Fee 500
EMD 57000
Exemption Available
Document List
Tender8883..pdf
Tendernotice_1.pdf
593dae51-3b03-4733-aa66-4cd80d769d78.html
BOQ_797380.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 24, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 01, 2025
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 24, 2025
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 01, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 03, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓

Tender8883..pdf

pdf

Tendernotice_1.pdf

html

593dae51-3b03-4733-aa66-4cd80d769d78.html

xls

BOQ_797380.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender