Supplying Installation Testing Commissioning And Providing Internal Electrification Of 40 Kva Silent Diesel Generator Set At Sdm Office Complex Belonia South Tripura
Tender Value
14.53 Lakhs
Estimated cost
Bid Submission
18 Jun 2025
0 days left
EMD
29071
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
belonia → Tripura
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
supplying Installation Testing Commissioning And Providing Internal Electrification Of 40 Kva Silent Diesel Generator Set At Sdm Office Complex Belonia South Tripura
BOQ
| Sl. No. | Item Description |
| 1 | Supplying , installation, testing and commissioning of 40 KVA DG set with STD panel, Acoustic enclosure i/c auto load transfer prime rating radiator cooled electric alternator with microprocessor based controller, residential silencer, Anti vibration mountings, Exhaust flexible connector, Fully charge batteries with neccessary cables complete with acoustic enclosure, extenstion of the silencer with necessary anti climate protection ( Upto 15m max) and standard Engine safety panel etc as required. |
| 2 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:- |
| 3 | Short Point :- |
| 4 | Medium Point :- |
| 5 | Long Point :- |
| 6 | Wiring for Circuit/Sub-main wiring with the following sizes PVC insulated copper conductor cable (FR) in PVC casing capping etc. as required:- |
| 7 | 2 X 1.5sq mm |
| 8 | 2 X 2.5sq mm |
| 9 | 2 X 4sq mm |
| 10 | 4 X 6 sq mm |
| 11 | 4 X 10 sq mm |
| 12 | Wiring for Circuit/Sub-main wiring with the following sizes of PVC insulated copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- |
| 13 | 1 X 1.5 sq mm |
| 14 | 2 X 4 sq mm |
| 15 | 2 X 6 sq mm |
| 16 | 4 X 16 sq mm |
| 17 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\"x 12\" having locking arrangement including CC work, holes on earth pipe etc. as required. |
| 18 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. |
| 19 | Proving and fixing / Drawing 4.06 mm dia (8 SWG) copperwire on surface or inexisting G.I / PVC / Polythene pipe for loop earthing as required. |
| 20 | Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of4.06mm (8SWG) dia G.I./ Copper wire forearth connection from earth electrodes etc as required. |
| 21 | Supplying & fixing of 1200 mm sweep white color AC ceilingfan capacitor typedouble ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR)(ISI marked, BEE 1star/minimum service value 4.0 m3/min/W) : - |
| 22 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
| 23 | Angle/batten holder |
| 24 | Ceiling rose |
| 25 | Supplying and fixing of the following PVC casing capping with all accessories etc. as required. |
| 26 | 20mm x 12mm |
| 27 | 25mm x 12mm |
| 28 | 32mm x 12mm |
| 29 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:- |
| 30 | Surface mounted integrated 20 watt LED batten with polycarbonate diffuser:- |
| 31 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 32 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 33 | 45 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 34 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:- |
| 35 | 100 amps 415 volts TPN main switch (rewireable):- |
| 36 | Supplying and installation of change over switch of following ratings with enclosure including necessary connection etc. as required:- |
| 37 | 100 amps FP on load change over switch (Front handle with enclosure): |
| 38 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connectionas required. |
| 39 | (2+6) / 8way SPN MCB DB (double door):- |
| 40 | (2+10) / 12way SPN MCB DB (double door):- |
| 41 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connectionas required:- |
| 42 | 6 to 32 amps SP MCB:- |
| 43 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:- |
| 44 | 40 amps DP isolator:- |
| 45 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:- |
| 46 | 63 amps 415 volts four strip Copper busbar chamber 4 ways of size (330 mm x 280 mm x 100 mm):- |
| 47 | 100 amps 415 volts four strip Copper busbar chamber 4 ways of size (455 mm x 330 mm x 120 mm):- |
| 48 | Supplyingandfixingoffollowing alluminum terminal ends: |
| 49 | 35 sq mm |
| 50 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 noslegs (25mmx25mmx5mm MS angle20 cm long) finishedwith red oxide and 2 coat synthetic enamel paintincluding necessary cc work, mending the damages & painting etc as required:- |
| 51 | Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per dirrection of Site Engineer :- |
| 52 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering,shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size):- |
| 53 | Centering shuttering including struttings, propping etc. and removal of form work for: Foundations, footings, bases for columns etc. for mass concrete with timber plank:- |
| 54 | 6 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete. In cement mortar 1 : 4 ( 1 cement : 4 fine sand ):- |
| 55 | Neat cement punning:- |
| 56 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required. |
| 57 | 3 core 4 Sq mm |
| 58 | 3.5 core 35 Sq mm |
| 59 | Drawing of armoured/un-armoured cable with proper saddeling etc as required:- |
| 60 | Providing beams including hoisting, fixing in position and applying wood preservative for the unexposed surfaces, etc. complete with :(SH:8.52-Page: 18,SoR 2023: PWD[Buildings] |
| 61 | Gamair Wood(SH:8.52.3-Page: 18,SoR 2023: PWD[Buildings] |
| 62 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required etc. complete as per direction of Engineer-in-charge.(SH//:11.1-Page: 9,SoR 2023: PWD[Buildings] |
| 63 | 0.63mm thick with zinc coating not less than 275gm/m2 (SH//:11.1.2-Page: 9,SoR 2023: PWD[Buildings] |
| 64 | Providing and fixing of 3 pin 6/10 amps plug point withmodulartype 6/10ampsswitch andsocketincludingconnectionwith 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modularswitch board, earthing the 3rd pin etc. as required:- |
| 65 | Providing and fixing of 3/6 pin 16/20 amps plug point withmodulartype 16/20ampsswitch andsocketincludingconnectionwith 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
AI Tender Summary
Tender Timeline
Jun 03, 2025
11:30 IST
Tender Published
Tender notice published.
CompletedJun 18, 2025
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJun 18, 2025
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender