Tender For Stage contract for Division Pahalgam Adv. Cost=₹ 20.00 Amount without GST= ₹ 16.95 GST amount= ₹ 3.05 -- 1 Earthwork in excavation by mechanical means in foundation trenches, drains, pipes and asbles etc (not exceeding 1.5 Mir In of 10 Sahin plant including dressing of sides and ramming of bottoms, lit upt 15 Mr Including griting out anated tod and disposal of surplus soil as directed and lead up to 50 Mtrs. 2 Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared. 3 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. 4 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m in -All kinds of soil. 5 Providing and laying hand packed stone soling in foundation under floors etc incl ramming, watering and consolidating complete.cort al carriages of all materials involved upto site of work complete job. 6 Providing and laying in position cement concrete of specified grade M-7 5 excluding the cost of centering and shuttering-All work at all levels in 1:48 (1 Cement 4 coarse sand 8 graded stone aggregate 40 mm nominal size) including cost and carriage of all materiali involved upto site of work complete job. 7 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design imis, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of RMC from transit mixer to site of laying excluding the cost of centering, shuttering finishing and forcement including cost of admixtures in recommended proportions as per 15 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability na per direction of the Engineer in charge Note Cement content considered in this item is @ 330 kg/ cum. Excess less cement used as per design mis is payable recoverable separately All works upto plinth level, complete job. 8 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement control as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS 9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer in charge Note Cement content considered in this item is 330 kg/ cum. Excess/ less cement used as per design mix is payable recoverable separately All works above Plinth Level & Upto Floor V Lvl, complete job. 9 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering 1.2.4 (1 cement 2 coarse sand 4 graded stone aggregate 20 mm nominal size), incl. carriages, complete. 10 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level, Thermo-Mechanically Treated bars of grade Fe-500D or more. 11 Brick masonry with FPS bricks of class designation 75 in super structure upto floor V level in cement mortar 1:6 (1 Coment: 6 course sand) comp-ete as per the directions of EIC including cost & carrings of all materials involved to site of work, complete job. 12 Brick masonry with FPS bricks of class designation 75 in foundation and plinth in cement mortar 1:6 (1 Coment: 6 course sand) comp-ete as per the directions of EIC including cost & carrings of all materials involved to site of work, complete job. 13 Providing and fixing Ist quality ceramic glazed Wall Tiles high gloss conforming to IS:13753 of miniumum thickness to min of approved make like NITCO, ORIENT, SOMANY KAJARIA or equivalent make in all colours, shades exceps begundy, bottle green, black of any size as approved by the Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick hed of Cement Mortar 1:3 (1 Cement 3 Coarse sand) and jointing with grey cement slurry @3.3kg per sqm including pomtang in white cement mixed with pigment of matching shade complete sample to be approved by Engineer-in- Charge Sizeof Tile 450 x 300 mm (including cost of all material, leads, lifts and carriages etc upto site of work complete) 14 Providing and fixing lat quality ceramic glazed Floor Tiles conforming to 15:13753 of miniumum thickness 6 mm of approved make like NITCO, ORIENT, SOMANY, KAJARIA or equivalent make in all colours, shades except begundy, bottle green, black of any size as approved by the Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of Cement Mortar 1:3 (1 Cement: 3 Coarse sand) and jointing with grey cement slurry @3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete sample to be approved by Engineer-in-charge. Size of Tile 300 * 40 num (including cost of all material, leads, lifts and carriages etc upto site of work complete). 15 Steel work in built up trusses etc, including cutting, hoisting, fixing in position and applying a priming coat of approved steel pruner, including welding andbolted with special shaped washers etc. complete 16 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 17 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 18 Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 19 Providing and fixing plained eaves boarding of (250*32mm) N/S with necessary grooves and chamfer as per detailed drawing) (Second Class Kail Wood) incl cost of nails 20 PF of 12mm thick T&G planks made of imported wood (New zealand pine or equivalent) for roof soffits & Ceiling on wood work in false ceiling, partitions sawn and putup in position in budloo wood (Ceiling Joists), including cost of necessary adhesive 35&cost of nails etc with necessary comice of required size complete job. incl cost of nails / screws all complete as approved by Engineer-in-charge (including cost of all material, leads, lifts and carriages ete upto site of work complete). Soffits 21 P/L pinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm (Nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand includingfinishing the top smooth. 22 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 liter/6 liter (adjustable to 4 liter/8 liters), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 23 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 24 Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 25 Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 26 15mm dia braided connection pipe. (of approved brand) 27 Providing and fixing of liquid soap dispenser with brackets fixed to wooden cleats with CP brass screws of approved brand. 28 Providing and fixing of CP brass Health faucet with 8mm dia 1 mir. Long PVC tube and wall hook fixed to wall with rawi plugs and CP brass screws complete of approved brand. 29 Providing in position storage type Hot Water electrical horizontal heaters with copper container, insulation, and stove enameled MS jacket, thermostatically controlled immersion heater, with pilot lamp, 15/20mm dia inlet with non return valve and 15/20mm dia outlet including making connections complete in all respects. (wall mounted with suitable M.S bolts and nuts) Capacity 50 Litte of approved brand. 30 Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required (For soil, waste, vent & rain water pipes) Nothing extra will be paid for supports. Make: Pipe & fittings:of approved brand110 mm outer dia 31 150 mm outer Dia. 32 Providing and fixing 3 layer PP-R(Poly propylene Random copolymer) pipes SDR 7.4 UV stabilized & anti-microbial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain and brass threaded 150mm outer dia polypropylene random fittings i/c fixing the pipe with clamps at 100m spacing. This includes the cost of cutting clases and making good the same including testing of joints complete as per direction of Engineer-in- charge of approved brand. 33 PN-16 Pipe 20mm OD 34 PN-16 Pipe 25mm OD 35 PN-16 Pipe 32mm OD 36 Carpenter for set right of existing doors, windows, wire gauge shutter i/c cost of Screws, Complete Job. 37 P/f of imported wooden 12mm thick (T&G) panelling fixed on 12mm ply board l/c f frame work of budloo wood incl. all carriages compelete-job Incl. Polishiong with two or more coats. 38 Providing and fixing of KHATAM BANDI ceiling of first class budloo/fir wood including the cost of frame work and applying coats of polish.Chaar Gul. All complete 39 P/F of wooden flooring of a class laminated wooden flooring (8mm) thick fixed on foam with proper resin material as per sample (MF-84 A with beading and door profiles 40 P/F Of file racks l/c 19mm plywood and dunmica 1-6 Deep with fixtures all complete. 41 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead. For thickness of tiles 10 mm to 25 mm 42 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. Size of tile 600*600 mm. 43 Providing & laying 16 mm minimum thick pre-polished (best quality) Granite stone slabs (non water absorbing) in counters, vanities etc on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand)/12mm thick backing of cement mortar 1:3 (1 cement: 3 coarse sand) and joined with white cement slurry mixed with pigment or with standard tile made compound to match the shade of the slab. Including rounding, rubbing, clamping, curing, moulding, granite polish & making grooves as required complete (Note: The stone slab shall be cut to required size and laid to the required pattern including rounding, chamfering, bull nosing of the edges as directed. Actual area of slab, as laid shall be measured) Sample to be approved by Engineer-In-charge. (including cost of all material, leads, lifts and carriages etc upto site of work, complete job. 44 P/F of 3.5mm hick glass panes with all fittings complete job. 45 P/f wall paper i/c carriage all complete job. 46 Providing and fixing PTMT brass bib cocks OF APPROVED QUALITY AND COLOUR. 15 mm bore, 122mm long, complete job. 47 P/F LOW level flushing cistern with manually controlled device. With all fittings and fixture complete. 48 P/F of PVC connection all complete. 49 Engagement of JCB for clearence of site, earthwork in excavation, removal of malba etc 50 Engagement of labour for one day 51 Engagement of skilled labour for one day 52 Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:: All kinds of soil 53 Providing and laying in position cement concrete of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including curing & carriage of material but excluding the cost of centring and shuttering. All work upto plinth level 54 Providing and laying in position reinforced cement concrete of 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) including curing & carriage of material but excluding the cost of centring and shuttering, complete 55 Providing and laying in position cement concrete of 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) including curing & carriage of material but excluding the cost of centring and shuttering, complete. 56 Centering & shuttering including strutting, propping etcincluding removal of form work for :Foundations, footings, bases for columns, plinth etc 57 Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 58 Lintel, beams, plinth beams, girders, bressumers and cantilevers. 59 Suspended floors, roofs, landings, balconies and access platforms. 60 Providing wood work in frames of doors windows, clerestory windows and other frames wrought framed and fixed in position with hold fasts lugs or with dash fasteners of required dia and length (hold fasts lugs or dash fasteners shall be paid for separately (imported Kail wood) including all carriages complete. 61 Providing and fixing 35panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (imported wood ) 62 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws , including panelling with Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side, Grade I, Type II . ( For Doors) 63 P/F and fixing 35mm thick wire gauze shutters using galvanized MS wire guaze of average width for aperture 1.4mm with wire of Dia 0.63mm for doors, windows and clerestory windowsincluding ISI marked bright finished or / and black enameledMS but hinges with necessary screws including all carriages complete (imported wood) 64 Providing and fixing of 4 mm thick glass panes (Weight not less than 10 kgs/Sam) including cost of wooden beadings 65 Providing and fixing of 0.5mm thick colour coated iron profile sheet roofing accessories in ridges, valleys etc (500 to600 MM wide) of approved profile and colouras approved by Engineer-in-Charge with self drilling /self tapping screws of size(5.5 x 55mm) with EPDM seal of same colour matching the shadeof ridges/valleysincluding carriage of same upto site of work complete. 66 12mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand) including Carriage complete 67 12mm Cement plaster on the rough side of single or half brick wall of mix: 1 :6 ( 1 cement : 6 fine sand) including Carriage complete 68 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand) including Carriage complete 69 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 :6 ( 1 cement : 6 fine sand) including Carriage complete 70 Providing/applying White cement based putty of average thickness 2mm of approved brand and manufacture over plastered wall surface to prepare the surface even and smooth including all carriages complete. 71 Providing and fixing of Hardware Fixtures toShutters of Doors & Windows:Brass Finished bright of std make :Tower Bolts 100mm length 72 Handles 100 mm 73 150 mm 74 L Drop(250mmx16mm) 75 Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete,complete. 25mm thick with 12.5 mm nominal size stone aggregate 76 40mm thick with 20 mm nominal size stone aggregate. 77 50 mm thick with 20mm nominal size stone aggregate. 78 Providing and laying of 50mm thick Coloured interlocked rubber moulded cement concrete tiles of required colour and manufactured in M20 Grade ( sample to be got approved by incharge engineer at site) laidover and including a Bed of 50 mm thick sand cusion with all carriages up to site of work 79 Providing and fixing of 18 mm thick plywood of approved brand and quality with all necessary fitting andfixtures and scafflolding all complete as per directions 80 Providing and fixing of 12 mm thick plywood of approved brand and quality with all necessary fitting andfixtures and scafflolding all complete as per directions 81 Providing and fixing of 6 mm thick plywood of approved brand and quality with all necessary fitting andfixtures and scafflolding all complete as per directions 82 Providing and fixing wooden moulded corner beading of size 50x50 mm (base and height) of triangular shape to the junction of paneling etc. with iron screws, plugs and priming coat on unexposed surface etc. Complete second class kail wood 83 Applying priming coat:With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 84 With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works 85 Painting with synthetic enamel paint two or more coats of approved brand and manfacturer on wood work 86 Painting with synthetic enamel paint two or more coats of approved brand and manfacturer on wood workon old work 87 Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) 88 Painting with aluminum paint of approved brand and manufacture to give an even shade. Two or more coats on new work 89 French spirit polishing, Two or more coats on new works including a coat of wood filler 90 Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats 91 Distempering with dry distemper of approved brand and manufacture (one or more coats) and of required shade on old work to give an even shade 92 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 93 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade, one or more coats on old work. 94 Painting with aluminum paint of approved brand and manufacture to give an even shade, one or more coats on old work. 95 French spirit polishing, one or more coats on old work 96 Providing/Fixing CP Brass fittings of standard quality and make (Jaguar/ equivelant standard make)Wall Mixer 97 Basin Mixer 98 Towel rod 99 Towel ring 100 Ball Value, 15 mm of C.P Brass 101 Ball Value, 20 mm of C.P Brass 102 Ball Cock 103 Tanky nipple 104 soap case 105 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 106 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 18.2.1 W.C. pan with ISI marked white solid plastic seat and lid 107 Providing/Fixing of PVC pipes and fittings ofprince make or equivelant including jointing / testingcomplete(B Type )Pipe 100mm dia 108 Pipe 75mm dia 109 Door Tee 100mm 110 Door Tee 75mm 111 Plain Tee 100mm 112 Plain Tee 75mm 113 Reducer 75 x100mm 114 Providing/Fixing of GI pipes and fittings ofapproved brand including jointing / testingcomplete(Medium Type )15mm dia 115 Pipe 20 mm 116 Pipe 25 mm 117 Union 15mm 118 Union 20 mm 119 Union 25mm 120 P/F of looking mirror of superior glass of approved make and required shape and size with plastic moulded frame with 6mm thick hard board backing size( 1.25x2.0 ) 121 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 127101 marked indicating the BIS licence no. with cover and suitable locking arrangements and making necessary holes for inlet, outlet and overflow pipes All complete 122 Construction of Brick masonry Man hole in cement mortat 1:4 with MS frame and cover including palasteringthe internal surface with 12 mm thich palster in 1:4( Size 1.5 x 1.5x1.5 ) all complete as per the directions of incharge engineer at site 123 P/l of wall-to- wall of superior quality including 10 mm thick thermocoal ( sample to be got approved from incharge engineer at site ) with all carriages, complete as per directions of EIC 124 Construction of wardrobe1.5 deep wardrobes cabin with 19 mm thick plywood and 10 mm thick plywood on back side ,plywood shutters fixed with denmica of std make on expopsed surfaceswith all fittings and fixtureslike handles, locks , catchers etc including carriage of materialall complete as per the directions of incharge engineer at site (Face area to be measured) 125 Construction of wardrobe2 deep ward robeswith 19 mm thick plywood and 10 mm thick plywood on back side ,plywood shutters fixed with denmica of std make on expopsed surfaceswith all fittings and fixtureslike handles, locks , catchers etc including carriage of materialall complete as per the directions of incharge engineer at site (Face area to be measured) 126 Providing and laying of pre cast RCC rings for soakage pitof dia 4 and height 7 including earth work in execution including all carriages all complete as per directions of EIC 127 P/fof pre castcement concrete slab for the soakage pitincluding all carriages all complete as per directions 128 Providing and laying of matting including cost of 10 mm thick foam including all costs complete job. 129 Providing and fixing of PVC panelling of approved pattern over and including base of 10mm thick plywood with frame work of budloo wood and finishing exposed surface with two coats of touchwood polish including cost of nails, adhesive material etc and all carriages complete. 130 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.)Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15) 131 Providing anf fixing of 4mm thick ACP board flat pressed in panelling fixed in aluminium doors, windows shutters and partition frames with CP brass/ stainless steel screws etc complete as per drawings and directions of EIC. 132 Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge:1:3:6 or richer mix (i/c equivalent design mix) 133 Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. 134 Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar 135 Providing and installing heating element of gyser including all costs complete 136 Dismantling steel work manually/by mechanical means in built up sections without dismembering and stacking within 50 meters lead as per direction of Engineer-in-charge 137 Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of : G.S. Sheet 138 Providing of plastic chairs of approved brand / make 139 Providing of sofa set3+1+1 ofapproved brand with cloth lining AND TABLENOT LESS 4X 3 140 P/F of queen size bed of standard make 141 P/F of VIP/Official chair of approved brand / make 142 P/F of BEDDING INCLUDINGDUNLOP 150 MM BED SHEET QUILT , BLANKET NOT LESS THAN 5.OO KGCUSHION FOR QUEEN SIZE BED 143 P/F of Wallpapers incl. All fixtures,Complete job. 144 Supply of Utensils (All items related to daily usage), complete job. 145 P/F of Curtains,including curtains rods, all fixtures.complete job 146 Providing and fixing of LED TV24 of standard brand and manufacture , wallmount ISI marked,complete. 147 P/f of Led lights, MCBs, Sockets incl. all fixtures.Complete job. 148 Providing and fixing of ceiling/table Fans incl. all necessary fixtures complete job. 149 Providing and fixing of Dustbins (20 ltr of good quality), complete job. 150 Harpic 151 Wiper 152 Phenyl 153 Colin 154 Toilet brush 155 Jug 156 Bucket 157 Standing Mop 158 Broom (Jadhu) 159 Providing and laying chisel dressed Devri Stone of size 300x200 mmface with 150 mm depth in cement mortar 1: 6 (1 cement : 6 coarsesand) upto plinth level including curing.One face dressed -Fine chiseldressed 160 Providing and laying chisel dressed Devri Stone of size 300x200 mmface with 150 mm depth in cement mortar 1: 6 (1 cement : 6 coarsesand) upto plinth level including curing.One face dressed -Rough chiseldressed 161 Providing and fixing of .5 mm thick high rib cgi sheets roofing of approved profile as approved by the engineer incharge inc carriage of same upto site of work complete the sheets should have proctective firm of 25 microns to avoid scratches while transformation and should be supplied in single length up to 12 mtrs 162 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid 163 P/F ofCP brass fittings of standard quality and make (Jaquar or equivalent)A)Sink Mixer 164 B)Wall mixer 165 C)Health Faucet 166 P/F of First class deodar wood in planks 167 S/F of Executive table of approved make as directed by EIC,Dimensions (In Centimeters)H 74 x W 180 x D 89, Primary Material Engineered Wood Warranty 36 Months Warranty of min weight 61 Kgs 168 Chequerred terrazzo tiles 22mm thick with graded marble chips of size upto 6mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, polishing and curing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) Light shade using white cement 169 P/F of devri stone fine chiselled pedestal 24x24 x24 in 1:6 mix inc pointing in 1:2 mix and also moulding of the edges and top slop cornice pedestal with depressed portion to hold the wooden post as per the approved design and pattern inc cost of stones and all carriages upto site 170 P/F of ornamental type vertical posts of ist class deodar wood of approved pattern and design inc P/applying 2 or more coats of touch wood polishing etc complete size 9x9 dia 12 heigh inc all carriages complete 171 Providing and fixing kitchen sink including making all connections excluding cost of fittings : 18.26.1 White glazed fire clay sink of size 600x450x250 mm 172 Supplying, fitting and fixing 8mm thickAC4 Grade Waterproof Laminated wooden Flooring Work including cornice of required size with plank size not less than 1218mm x 193mm) mm (with unilin/tongue-groove locking arrangement) having 0.2mm thick top abrasive layer over a decorative layer followed by a High-density fibreboard (HDF) having density > 850 kg/m3 substrate core over a resin saturated backing layer and installing through unilin or tongue- groove system (having locking strength not less than 1000 kg/m) over a 2 mm thick underlayer polyurethane foam on polythene sheet 250 microns, over a smooth, flat, hard subfloor free from moisture (<8%), grease etc. complete in all respect with requisite accessories like end profile, transition profile, reducer T profile etc. wherever required and preparation of base including all other incidental works as per direction & satisfaction of Engineer in charge 173 Providing and applying Duco paint finish on approved wood or metal surfaces, including surface preparation, filling, priming, undercoating, and top coating with high-quality nitrocellulose-based Duco paint by spray application to achieve a smooth, hard, high-gloss finish as per manufacturer’s specifications and instructions of Engineer-in-Charge 174 Electric Part 175 Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Group-A) 176 Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI box earthing the point with 1.5 sq. mmFRLS PVC insulated copper conductor single core cable etc as required (Group-A) 177 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. (Group-A) 178 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc.as required. 179 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 amps & 15/16 amps. modular socket outlet and 15/16 amps modular switch connection etc. as required. 180 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. 181 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. 182 Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 183 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 184 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 185 Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.2x1.5Sq.mm+ 1 x 1.5Sq.mm earth wire 186 2x2.5Sq.mm+ 1 x 2.5Sq.mm earth wire 187 2x4.0Sq.mm+ 1 x 4.0Sq.mm earth wire 188 2x6.0Sq.mm+ 1 x 6.0Sq.mm earth wire 189 2x10.0Sq.mm+ 1 x 6.0Sq.mm earth wire 190 2x16.0Sq.mm+ 1 x 6.0Sq.mm earth wire 191 4x6.0Sq.mm+ 2 x 6.0Sq.mm earth wire 192 4x10.0Sq.mm+ 2 x 6.0Sq.mm earth wire 193 4x16.0Sq.mm+ 2 x 6.0Sq.mm earth wire 194 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). 195 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.1 x 1.5 sq. Mm 196 2 x 1.5 sq. Mm 197 3 x 1.5 sq. Mm 198 1 x 2.5 sq. Mm 199 2 x 2.5 sq. Mm 200 3 x 2.5 sq. Mm 201 1 x 4.0 sq. Mm 202 2 x 4.0 sq. Mm 203 3 x 4.0 sq. Mm 204 4 x 4.0 sq. Mm 205 5 x 4.0 sq. Mm 206 6 x 4.0 sq. Mm 207 1 x 6.0 sq. Mm 208 2 x 6.0 sq. Mm 209 3 x 6.0 sq. Mm 210 4 x 6.0 sq. Mm 211 5 x 6.0 sq. Mm 212 6 x 6.0 sq. Mm 213 1 x 10.0 sq. Mm 214 2 x 10.0 sq. Mm 215 3 x 10.0 sq. Mm 216 1 x 16.0 sq. Mm 217 2 x 16.0 sq. Mm 218 3 x 16.0 sq. Mm 219 Supplying and drawing following pair 0.5 mm dia FRLS PVCinsulated annealed copper conductor, unarmored telephonecable in the existing surface/ recessed steel/ PVC conduit as01 pair 220 02 pair 221 04 pair 222 Supplying and fixing of ceiling fan offollowing sweep with 2.25 mfd condenser and 1-6 down rod on the existing fan hook with necessary connection from ceiling rose to fan using twin core copper wire. 900 mm sweep 223 1200 mm sweep 224 Supplying & fixing of Pedestal Fan 400 225 Supplying and fixing of 400 mm sweep wall mounting fan (oscillating type)on wall with necessary connection as required. 226 Supplying and fixing of following sizesexhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan.150 mm/ 6” sweep exhaust fan 227 200 mm/ 8” sweep exhaust fan 228 225 mm / 9 sweep exhaust fan 229 300mm/12 sweep exhaust fan 230 380mm/15 Heavy duty 231 Supplying and fixing of fan hook (U hook) on ceiling with 2 nos. of anchor fastener on both ends with necessary bolts andnuts and masonry work as required. 232 Supplying & fixing of following way single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess complete with tinned copper busbar neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 6 way (Double door) 233 8 way (Double door) 234 12 way (Double door) 235 16 way (Double door) 236 Supplying & fixing of following way horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper bus bar neutral buss bar, earth bar, din bar interconnection ,powder painted including earthing etc. as required. 4 Way (4+12), (Double door ) 237 6 Way (4+18), (Double door ) 238 8 Way (4+24), (Double door ) 239 12 Way (4+36), (Double door ) 240 Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 2 meter length, with 3mm thick the electrode should be hot-dip galvanized. The GI Electrode shall bepre-filled with Crystalline Conductive Material (CCM). The GI electrode shall be surrounded withBEE MOIST compound to provide maximum contact between the electrode and compound should be eco-friendlyGI Electrode Earthing should be maintenance free and does not requireregular manual addition of water . The earthing pit should be covered with PVC cover. 241 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. 242 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 243 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 244 Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minimum 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compound. The compound should be eco-friendly The earthing pit should be covered with PVC cover. 245 Earthing with copper earth plate 600 mm X 600 mm X 3 mmthick including accessories, and providing masonry enclosurewith cover plate having locking arrangement and watering pipeof 2.7 meter long etc. with charcoal/ coke and salt as required. 246 Providing and fixing of 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. 247 Providing and fixing 4.00 mm dia copper wire on surface or inrecess for loop earthing as required. 248 Supplying and fixing of following sizes of PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI Make).20 mm dia. 249 25 mm dia. 250 32 mm dia. 251 40 mm dia. 252 Supplying and fixing of Following light fitting on ceiling/ wall with necessary connection from as required.Post Light 35 watts 253 20/22 watt LED 4 feet tube light fitting/fixture 254 Decorative LED Hanging Light for officer table as approved by site Engineer 255 LED Batten Tube fitting 600mm size 10/11 watt 256 600 mm x 600 mm size recessed mounted LED Luminaries 34/36 watt. havingminimum 3600 Lumens with minimum lumens efficiency 110 Lumens/watt (Commercial type) 257 Mirror light LED fitting with 9/11W LED lamp 258 Providing and fixing of LED Lamp.5W 259 9W 260 12W 261 15W 262 18W 263 20W 264 Providing and fixing of E-27 LED Light 9 watt (warm) 265 9 watt (White) 266 12 watt (warm) 267 12 watt (White) 268 Supply and fixing of following LED type Street / flood lights including GI pipe bracket and connections etc as required. 45-50 watt 269 60-70 watt 270 90 -100watt 271 Supplying and installation of recessed/surface mounted slim circular/square type down lighter of following rating.(Aluminum body)9/10 watt 272 12/15 watt 273 18/22 watt 274 Providing & fixing of following accessories. 5/6 Amp. 3 pinTop 275 5/6 Amp 2 pin Top 276 15/16 Amp 3 pin top 277 Insulation Tape (ISI brand) 278 Electronic Step Type fan Regular (Piano type) 279 Ceiling Rose 280 2.2/3/3.5 mfd fan condenser 281 Brass batten/angle holder includingconnection etc. as required. 282 Dimmer Type Regulator (with numbering) 283 5/6 Amp SS combined 284 15/16 Amp SS combined 285 Toolkit comprises of plier, screw driver and Phase tester 286 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm x 75mm) 287 3 Module (100mm x 75mm) 288 4 Module (125mm x 75mm) 289 6 Module (200mm x 75mm) 290 8 Module (125mm x125mm) 291 12 Module ( 200mm x 150mm) 292 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module 293 3 Module 294 4 Module 295 6 Module 296 8 Module 297 12 Module 298 Supplying and fixing following piano type switch/ socket on the existing box/ cover including connection etc. as required.5/6 amp switch 299 15/16 amp switch 300 3 pin 5/6 amp socket outlet 301 6 pin 15/16 amp socket outlet 302 Telephone socket outlet 303 TV Antenna socket outlet 304 Bell push 305 2 pin socket outlet 5 Amp. 306 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required. 5/6 amps switch 307 2 way 5/6 amps switch 308 15/16 amp switch 309 3 pin 5/6 amp socket outlet 310 6 pin 15/16 socket outlet 311 Telephone socket outlet 312 TV Antenna socket outlet 313 Bell push 314 2 pin socket outlet 5 Amp. 315 Rewinding of the following fans using enameled copper wire of required gauge, varnishing oiling greasing etc. The workmanship shall up to the satisfaction of the Engineer in charge.900mm /1200mm / 1400mm sweep AC ceiling fan 316 Up to 300mm sweep exhaust fan 317 Servicing of the Geyser etc. as required. 318 Supplying and replacement of the suitable size and rating of the following in the storage water heater and making the geyser in good working condition. (Make as per the geyser installed).Heating Element 319 Thermostat with control 320 Replacement of Assembly complete job 321 Supplying, installation, testing and commissioning of Cubical type Indoor/OutdoorLT Panel Board Suitable for 415 V 3 Phase 4 wire 50 Hz AC supply system with provision for housing incomers, Out Going, COS, Bus Bars etc. as required but excluding the cost of MCCBs, Bus Bars and Change over as per the following Description (IP:42) General Floor Distribution Panel. The successful tenderer shall take prior approval for the panel builder/fabricator along with G.A drawing wiring diagrams, single line diagram before start of fabrication of LT panel Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating. Thepanel Builder shall be CPRI/ERDA/ANY NABL ACCREDITED LAB approved. 322 Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type).100 Amp, 30 KA, FP MCCB ICU = 100% ICS 323 160 Amp, 36 KA, FP MCCB ICU = 100% ICS 324 200 Amp, 36 KA, FP MCCB ICU = 100% ICS 325 250 Amp, 36KA, FPMCCB ICU = 100% ICS 326 320 Amp, 50 KA, FPMCCB ICU = 100% ICS 327 400 Amp, 50 KA, FPMCCB ICU = 100% ICS 328 ON Load Change Over Switch FP 100 amp. (Front operated) 329 ON Load Change Over Switch FP 200 amp. (Front operated) 330 ON Load Change Over Switch FP 250 amp. (Front operated) 331 Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Bus Bar Indicating Lamp, CT Set etc. 332 Providing and fixing of PCB in wall fans (Remote control type) having sweep 400 mm of make Havells/ CG. 333 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminum power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 10 sq. mm 2 core 334 16 sq. mm 2 core 335 25 sq. mm 2 core 336 35 sq. mm 2 core 337 50 sq. mm 2 core 338 16 sq. mm 4 core 339 25 sq. mm 3.5 core 340 35 sq. mm 3.5 core 341 50 sq. mm 3.5 core 342 70 sq. mm 3.5 core 343 95 sq. mm 3.5 core 344 120 sq. mm 3.5 core 345 150 sq. mm 3.5 core 346 185 sq. mm 3.5 core 347 240 sq. mm 3.5 core 348 300 sq. mm 3.5 core 349 400 sq. mm 3.5 core 350 Supplying and fixing of twin core aluminum cable all along the wall surface unarmoured.6 sq. mm 351 10 sq. mm 352 16 sq. mm 353 25 sq. mm 354 35 sq. mm 355 Labour charge for electrician 356 Labour charge for Helperelectrician 357 Supplying & Drawing of Co- axial TV cable RG-6 grade, 0.7 mm solid copper conductor. 358 Supplying & Drawing of UTP 4 point Cat-6 cable (1 run cable) (D-Link, Schneider, Systimax) 359 Supplying ofRemote Bells 360 Supplying & fixing of following PVC Gang Box.One way 361 Two way 362 1 + 1 way 363 3 + 1 way 364 4 + 1 way 365 6 + 1 way 366 1 + 1 way (Power) 367 Supplying & fixing of Electrical AccessoriesPVC Casing and Caping (Batten).Casing Caping 1 368 Casing Caping 3/4 369 Deep Box 370 Fan Box 371 Concealed Box 372 Junction Box (Metal) 373 Supplying and fixing ofPhenolic Laminated Sheet 9 x 11including cutting the space for switches/socket etc. 374 Supplying and fixing of Phenolic Laminated Sheet 9 x 6 including cutting the space for switches/socket etc. 375 Supplying and fixing of Phenolic Laminated Sheet 4 x 4 including cutting the space for switches/socket etc. 376 Supplying and fixing of Phenolic Laminated Sheet 11 x 13 including cutting the space for switches/socket etc. 377 Supply and fixing of single phase of following rating self priming for pumping water including connections etc as required.(Copper winding)0.5 HP 378 1.0 HP 379 Rewinding of 1 phase (0.5 HP) motor for water lifting (Copper winding) 380 Rewinding of 1 phase (1 HP) motor for water lifting (Copper winding) 381 Supply & installation of following type inverters.Inverter 850VA-1050 VA 382 Inverter 1450VA-2000 VA 383 Supplying & fixing of Battery 12 Volt. Tubular 150/180 AH with36 months Guarantee Note.:- (Rs.2500 /Battery has to be deduct for the scrap of old batteries from allotted rate in case of replacement of battery is out of warranty period. 384 Supplying & fixing of PVC Trolley for housing single battery inverter 385 Supplying & fixing of PVC Trolley for housing double battery inverter 386 Repair to PCB of inverter850 VAto 1050 VA 387 1450 VA to 2000 VA 388 Replacement of PCB of inverter850 VAto 1050 VA 389 1450 VA to 2000 VA 390 Full HD 2/3/4 MP 1080P D&N IP IR Dome/Bullet Camera (with SD Card Slot) 391 Full HD 5 MP 1080P D&N IP IR Dome/Bullet Camera (with SD Card Slot) 392 Supply Installation Testing & Commissioning of 3 Core Power Cable 1.5 sqmm. 393 Supply, Installation, Testing and commissioning of 8 port Layer ‑2 un- managableSwitch with Power on Ethernet (PoE) enabled, with 8 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe Port for copper/fibre uplink, 20 Gbps switching capacity, 14.88 MPPS Forwarding performance , maximum power consumption 64 watt. 394 Supply, Installation, Testing and commissioning of 24 port Layer ‑2 un- managable Switch with Power on Ethernet (PoE) enabled, with 8 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe Port for copper/fibre uplink, 20 Gbps switching capacity, 14.88 MPPS Forwarding performance , maximum power consumption 64 watt. 395 Supplying ,installation testing and commissioning of 32 Channel Network Video Recorder (NVR) minimum 4 sata. 396 Supplying ,installation testing and commissioning of 16 Channel Network Video Recorder (NVR) minimum 4 sata (as per specification enclosed). Make:-Bosch, Pelco, Samsung, Sony, Honeywell, AXIS 397 6 TB surveillance Hard disk storage device. 398 4TB surveillance Hard disk storage device. 399 Micro SD/SDHC Card 128 GB 400 1 mtr. Cat 6 Networking patch cord cable. 401 Supply offollowing electrical /networking components.ADSL Modem Router Double Antenna 402 8 Port Switch (Networking Switch) 403 16 Port Switch (Networking Switch) 404 24 Port Switch (Networking Switch) 405 24 Port Patch Panel 406 Adaptor for charger 407 RJ 45 Jack complete 408 PVC I/O Box with RJ 45 jack outlet connection (Modular) 409 HDMI Cable 3 Mtrs. 410 HDMI Cable 10 Mtrs. 411 HDMI Cable 20 Mtrs. 412 Supply Installation Testing & Commissioning offollowing sizesEquipment Rack with provision for housing all control equipment with front & rear door, Blower for cooling, power Distribution Paneland proper locking arrangements.4 U Rack 413 6 U Rack 414 Supplying, installation, testing and commissioning of 1 KVA offlineUPS with minimum backup of 20 minutes and having over load, short circuit protection. 415 Supplying, fixing & commissioning of Storage Water Heater (Geyser)of following capacity along with PVC Pipes etc as required.5/6 Ltr (instant) 416 15 Ltr 417 25 Ltr 418 35 Ltr 419 50 Ltr 420 Supply ofHalogen Electrical heaters (3 Rods) 421 Supply ofHeating Convector (Blower) 422 Supply ofPillar Heater 423 Supply ofRod for Pillar Heater 424 Supply of following electrical appliances.Electric Fly Catcher 425 Electric Kettle above 1 Ltr. Upto 2 Ltr. Capacity. 426 Supplying of extension Card for bearing load upto 4 KW 427 Repairing & Servicing of D.G set by way of changing of the oil, filters and other repairs as required to make the Gen set in good working condition 428 Supplying, installation, testing and commissioning of following type of water purifiers along with PVC connecting pipes as required.(RO + UV + UF mineral control with TDS control ) 429 UV purifier for water cooler 430 Supplying, installation, testing and commissioning of1.5 Ton Inverter type SplitACs (copper) (3 star) Hot/ Cold (all weather) type of minimum capacity following sizes as detailed below. Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features.Repairs made to wall wherever required. Complete withwall stand outdoor etc.Warrantee.:-a). Warrantee shall be provided for 12 month from the date of installations. b). The compressor shall be warranted for 5 years from the date of installation. 431 Supplying, installation, testing and commissioning of2.0 Ton Inverter type SplitACs (copper) (3 star) Hot/ Cold (all weather) type of minimum capacity following sizes as detailed below. Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features.Repairs made to wall wherever required.Warrantee.:-a). Warrantee shall be provided for 12 month from the date of installations. b). The compressor shall be warranted for 5 years from the date of installation. 432 Supplying, installation, testing and commissioning of1.5 Ton Inverter type SplitACs (copper) (3 star)Cold type of minimum capacity following sizes as detailed below. Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features.Repairs made to wall wherever required. Complete withwall stand outdoor etc. Warrantee.:-a). Warrantee shall be provided for 12 month from the date of installations. b). The compressor shall be warranted for 5 years from the date of installation. 433 Supplying, installation, testing and commissioning of1.5 Ton Inverter type SplitACs (copper) (5 star) Hot/ Cold (all weather) type of minimum capacity following sizes as detailed below. Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features.Repairs made to wall wherever required.Warrantee.:-a). Warrantee shall be provided for 12 month from the date of installations. b). The compressor shall be warranted for 5 years from the date of installation. 434 Supplying, installation, testing and commissioning of2.0 Ton Inverter type SplitACs (copper) (5 star) Hot/ Cold (all weather) type of minimum capacity following sizes as detailed below. Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features.Repairs made to wall wherever required.Warrantee.:-a). Warrantee shall be provided for 12 month from the date of installations. b). The compressor shall be warranted for 5 years from the date of installation. 435 Supplying, Installation, Testing & Commissioning of 4KVA capacity automatic voltage stabilizer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary.Warrantee.:-2 Years from the date of installation. 436 Supplying, Installation, Testing & Commissioning of 5KVA capacity automatic voltage stabilizer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary.Warrantee.:-2 Years from the date of installation 437 Supplying, Installation, Testing & Commissioning of 2-3KVA capacity automatic voltage stabilizer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary.Warrantee.:-2 Years from the date of installation. 438 Supplying & fixing of M.S Wall Stand duly powder coated for outdoor unit of Split AC 439 Supplying & fixing of drain pipe for indoor unit 1 440 Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 1.5 Ton AC 441 Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 2.0 Ton AC 442 Supply, erection, testing and commissioning of compressor suitable for 1.5/2 Ton split /window type A.C with Gas charging and other required accessories to get A.C workable. 443 Provision of Gas charging of 1.5/2.0 Ton split/ window type A.C including valve etc if required. 444 Installationof 1.5/2.0 Ton window A.C 445 Installation of 1.5/2.0 Ton split A.C 446 Servicing of Split AC of All Capacities 447 Servicing of Window AC of All Capacities 448 Replacement of defective motor of 1.5 /2.0 Ton Split /Window A.C Outdoor 449 Replacement of defective capacitor for 1.5 /2.0 Ton Split /Window 450 Providing & fixing of Blades of 1.5/2.0 Ton Split / Window A.C 451 Providing & fixing of Blower drum (Split AC)1.5 Ton Split A.C 452 1.5 Ton Window A.C 453 Supply, erection, testing and commissioning compressor suitable for 150/150 ltrs. Water cooler with gas charging and other required accessories to get water cooler workable. 454 Supply, erection, testing and commissioning compressor suitable 40/80 ltrs. Water cooler with gas charging and other required accessories to get water cooler workable. 455 Provision of Gas charging of water cooler 150/150 ltr. 456 Provision of Gas charging of water cooler 40/80 ltr. 457 Removing of existing Split AC & reinstallation of Split AC with gas top up 458 Removing of existing Window AC & reinstallation of Window AC. 459 Removing of existing Split AC of All Capacities 460 Removing of existing Window AC of All Capacities 461 Repair ofPCB of Split/Window AC 1.5/2.0 Ton 462 Servicing of Water purifier by replacing candles. (R.O type) 463 Servicing of Water Purifierby replacing Candles of water cooler 464 Supplying, installation, testing and commissioning of 12 V 65 AH-SMF -VRLA batteries for UPS of 10 KVA. 465 Repair to the existing Audio system LED display installed in Conference/ meeting Hall by way of repair/replacement of delegate /chairman unit, amplifier, mixer, andall other equipments so as to make it fully functional. 466 Repair to the existing UPS by way of replacement of master card and other items . 467 Supply and installation of following ratings of MCB/ DP/TPN ,incl. Necessary connections, but excl. Cost of DB. (Havells/ Legrand/ L&T/ Schneider)6A/ 10A /16A / 25A/ 32AMCB 468 32ADP 469 40ADP 470 63ADP 471 40ATPN 472 63ATPN