Tender For Purchase Of Physiotherapy Equipments For Rajiv Gandhi Sports Medicine Center, Thiruvananthapuram-- 1 Physiotherapy Equipment 12% GST 2 OD25630/2025-2026: Combination therapy unit- Electrotherapy and Ultrasound1. Combination therapy unit having facility of electrotherapy and ultrasound2. Should have medical encyclopaedia into the system with anatomical library, and Informative screens.3. Should have facility for pre- programmed protocol selection through list navigation/quick Protocols/body part navigation.4. Should have large colour touch screen display5. Should have large number of pre-programmed indications for electrotherapy (more than 70), ultrasound (more than 50) - total more than 100 pre-set programs6. Should have the facility of up-grading the firmware in future7. Should be able to treat 2 patients at the same time with independent therapies or same patient with 2 different indications.8. Should have possibility to operate ultrasound simultaneously/independently while giving 4 pole electrotherapy treatment or two 2- pole treatments and 1 ultrasound therapy simultaneously.9. Should have ISO certification with CE or FDA certification.10. Should have option for operation through battery.Electrotherapy unit1. Should have 2 channel electrotherapy with both independent channels2. Should have the following currents: Galvanic, Faradic, Neofaradic, Diadynamic currents, TENS currents (sym, asym, alt), interferential currents(2 pole, 4-pole, isoplanar and dipole vector field), micro currents, high voltage therapy, H-wave, Leduc current, Medium Frequency surges, exponential pulses, exponential pulses with rise, combined pulses, interrupted pulses, rectangular pulses, Traebert pulses, Russian stimulation, Stimulation pulses, Rectangular pulses, Triangular pulses, Interrupted pulses and Medium frequency surges, Spastic stimulation - Hufschmidt, Spastic stimulation - Jantsch, HVT, IG pulses, Modulated pulsed current, VMS current, Kotz current, EPIR.3. Should have electro-diagnostics (measuring of I/T curves in user defined number of points, free programme position for I/T curve storing, determination of motor point, calculation of rheobasis and chronaxie, measuring of the accommodation coefficient).4. Should have facility for Constant Voltage/ constant Currents modes5. Should have facility of plotting and storing SD curves for comparison and future reference.6. Should have:Mains supply: 230V/50-60Hz, 115V/50-60HzClass according to MDD 93/42/EEC : IIbUltrasound therapyFunctional features:1. Should have ergonomic heads with facility for visual accessory identification/visual patient contact indicator on screen as well as on treatment head.2. Should have head warming facility for treatment head.3. Should have facility to connect 2 US heads at the same time and same should be available for selection while setting up parameters for treatment through software saving operators time and effort.4.Should have large ultrasound applicator and simultaneous treatment with 1&3MHz for future upgrade.Technical features1. Ergonomic Multi frequency treatment head for 1& 3 MHz treatment (Standard-ERA 5cm2 and Optional- 1 cm2 )2. Alternating frequencies 1 and 3 MHz allowing simultaneous treatment with 1 and 3 MHz3. Duty factor of 5-95%, in steps of 1%4. modular frequency: 10-150Hz.5. Peak intensity of0-2 W/cm² - duty cycle 100% in continuous mode0-3 W/cm² - duty cycle < 100% in pulsed mode.6. beam non-uniformity ratio<57. Head warming facility.8. Treatment time of 0-30 minutes 3 OD25631/2025-2026:Combination therapy unit- Electrotherapy and Ultrasound with hands free ultrasound applicator1. Combination therapy unit having facility of electrotherapy and ultrasound2. Should have medical encyclopaedia into the system with anatomical library, and Informative screens.3. Should have facility for pre- programmed protocol selection through list navigation/quick Protocols/body part navigation.4. Should have large colour touch screen display5. Should have large number of pre-programmed indications for electrotherapy (more than 70), ultrasound (more than 50) - total more than 100 pre-set programs6. Should have the facility of up-grading the firmware in future7. Should be able to treat 2 patients at the same time with independent therapies therapies or same patient with 2 different indications.8. Should have possibility to operate ultrasound simultaneously/independently while giving 4 pole electrotherapy treatment or two 2- pole treatments and 1 ultrasound therapy simultaneously.9. Should have ISO certification with CE or FDA certification.10. Should have option for operation through battery.Electrotherapy unit1. Should have 2 channel electrotherapy with both independent channels2. Should have the following currents: Galvanic, Faradic, Neofaradic, Diadynamic currents, TENS currents (sym, asym, alt), interferential currents(2 pole, 4-pole, isoplanar and dipole vector field), micro currents, high voltage therapy, H-wave, Leduc current, Medium Frequency surges, exponential pulses, exponential pulses with rise,combined pulses, interrupted pulses, rectangular pulses, Traebert pulses, Russian stimulation, Stimulation pulses, Rectangular pulses, Triangular pulses, Interrupted pulses and Medium frequency surges, Spastic stimulation - Hufschmidt, Spastic stimulation - Jantsch, HVT, IG pulses, Modulated pulsed current, VMS current, Kotz current, EPIR.3. Should have electro-diagnostics (measuring of I/T curves in user defined number of points, free programme position for I/T curve storing, determination of motor point, calculation of rheobasis and chronaxie, measuring of the accommodation coefficient).4. Should have facility for Constant Voltage/ constant Currents modes5. Should have facility of plotting and storing SD curves for comparison and future reference.6. Should have:Mains supply: 230V/50-60Hz, 115V/50-60HzClass according to MDD 93/42/EEC : IIbUltrasound therapyFunctional features:· Should have ergonomic heads with facility for visual accessory identification/visual patient contact indicator on screen as well as on treatment head.· Should have head warming facility for treatment head.· Should have facility to connect 2 US heads at the same time and same should be available for selection while setting up parameters for treatment through software saving operators time and effort.· Should have large hands free ultrasound applicator-4 crysta( 12 cm2) with rotary field technology and simultaneous treatment with 1&3MHz for future upgrade.Technical features:· Ergonomic Multi frequency treatment head for 1& 3 MHz treatment (Standard- ERA 5cm2 and Optional- 1 cm2 )· Alternating frequencies 1 and 3 MHz allowing simultaneous treatment with 1 and 3 MHz · Duty factor of 5-95%, in steps of 1%· modular frequency: 10-150Hz.· Peak intensity of0-2 W/cm² - duty cycle 100% in continuous mode0-3 W/cm² - duty cycle < 100% in pulsed mode.· beam non-uniformity ratio<5· Head warming facility.· Treatment time of 0-30 minutes 4 OD25629/2025-2026: Super Inductive System Therapy Device Intensity of Electro Magnetic field - up to 2.5 TeslaFrequency - 1 to 150HzFunctions & Technical Characteristics1. Highly-effective, non-invasive treatment for Pain, Joint Mobilization, Spasticity reduction, Fracture healing2. The systems should have Multi-language user interface3. The unit must have Built-in Therapeutic encyclopedia - description and images explaining application of all pre-programmed treatment programs4. Should have Pre-programmed protocols5. The device must have Large Touch Color screen display - 8.4 inches6. The device must do Self-identifications of accessories and accessories maintenance check7. The device must have only one single universal applicator8. The focused field applicator must have intensity in range of 0.7 to 2.5 Tesla9. Frequency range must be from 1-150 Hz (Should be able to operate from 1Hz to 150 Hz frequency)10. screen pen pointer should be available Touch11. The device must have single Applicator arm with Cable holder12. For holding the applicator, it should have 6 Joint arm installation set13. The device must provide hands free, therapist independent application though the holder14. Mains supply voltage 100-230V / Frequency 50-60Hz15. Class according to MDD 93/42/EEC - II a16. Should have ISO certification with CE or FDA certification 5 Trolley 18% GST 6 OD25632/2025-2026 : Supply of Trolley for Combination therapy unit with atleast 6 drawers for storage ofaccessories as per the direction of Engineer in Charge