Tender for Ortho Implant Items Supply , Ortho Implant , Cruciate Retaining (Cr) Tkr(With Cocr Femoral Componenttibia Base Plate (Titanium/Cocr), Vitamin E Enriched Polyethylenee Liner (Regular Cr/Ultracongruent) And All Poly Patella , Posterior Stabilized (Ps) Tkr(With Cocr Femoral Component , Tibia Base Plate (Titanium/Cocr), Vitamin E Enriched Polyethylene Stabilized Liner And All Poly Patella Button). , Revision Tkr Semi Constraint Total Knee Prosthesis Including Femoral Component + Constrained Poly+ Tibia + Tibial Rod) , Tibial Component With Ability To Accept Various Offset And Sizes Tibial (Augmentation Blocks), Wedges & Offset Extension, , Semi Constraint Tibial Knee Inserts -All Sizes , Metal Tibial Wages-Step, Hemi & Full Of Various Sizes And Thickness , Tibial Extension Stem-Various Offset & Sizes For Cemented And Uncemented, Partially Coated , Thr (Uncemented Metal On Poly ) , Primary Uncemented Partially/Fully Coated Femoral Stem (Titanium Alloy)-12/14 Taper, Collared And Collarless Option Reduced Lateral Shoulder Taper, Wedge Type, With A Option Of Variable High Offsets And Various Size. Thickness Of Coating (135Mm To 180Mm), Stem Sizes (0 To 9), Stem Tip – Rounded. Metal Head – Metal Femoral Head Is Made From Highly Polished Cobalt Chrome Alloy (Cocr) Comes With 28,32,36Mm Options And Has A 12/14 Taper, Attach To A Corresponding Tapered Femoral Stem And Articulates With A Polyethylene Liner With Modularity In Head Size With Neck Length – At Least 4. Uncementedacetabular Cup Component – Titanium Porous Coated (Pore Size 200-300 Micron) (Thickness Of Coating 140 To 180Mm) Acetabular Hemispherical Uncemented Component With Tapered Locking Mechanism For Liner Multiple Locking Screws Options Od-38 To 64Mm With 2Mm Of Increment Acetabular Highly Crosslinked Poly Cup – Highly Crosslink Polyethylene Option Of Neutral, 10*Lpw, Lateralized Liner.6.5 Mm Self Tapping Cancellous Titanium Screws For Acetabular Cup (Uncemented Cup Size 42 To 68 Size Cup) , Thr (Uncemented Ceramic On Poly) , Primary Uncemented Partially/Fully Coated Femoral Stem (Titanium Alloy)-12/14 Taper, Collared And Collarless Option Reduced Lateral Shoulder Taper, Wedge Type, With A Option Of Variable High Offsets And Various Size. Thickness Of Coating (135Mm To 180Mm), Stem Sizes (0 To 9), Stem Tip – Rounded. Ceramic Head-Comes With 28,32,36Mm Options And Has A 12/14 Taper, Attach To A Corresponding Tapered Femoral Stem And Articulates With A Polyethylene Liner With Modularity In Head Size With Neck Length – At Least 4.Uncementedacetabular Cup Component – Titanium Porous Coated (Pore Size 200-300 Micron) (Thickness Of Coating 140 To 180Mm) Acetabular Hemispherical Uncemented Component With Tapered Locking Mechanism For Liner Multiple Locking Screws Options Od-42 To 68Mm With 2Mm Of Incrementacetabular Highly Crosslinked Poly Cup – Highly Crosslink Polyethylene Option Of Neutral, 10*Lpw, Lateralized Liner. 6.5 Mm Self Tapping Cancellous Titanium Screws For Acetabular Cup (Uncemented Cup Size 42 To 68 Size Cup) , Thr (Cemented Metal On Poly) , Cemented Femoral Stem, Double Tapered)- 12/14 Taper,Collarless, Reduced Lateral Shoulder Taper, Wedge Typemetal Modular Head 28Mm, 32Mm, 36Mm, (12/14 Taper) With At Least 4 Variable Neck Length Cemented 10° Acetabular Cup With Lpw Various Sizes Lpw Cemented Acetabular Cup Femoral Cement Restrictor Femoral Cement Centerlizer Withdisposable Cement Gun & Pulsatile Lavage. , Thr (Hybrid Metal On Poly) , Cemented Femoral Stem(Titanium Alloy, Double Tapered)- 12/14 Taper,Collarless, Metalmodular Head 28Mm, 32Mm, 36Mm. (12/14 Taper) With At Least 4 Variable Neck Length Uncementedacetabular Cup Component – Titanium Porous Coated (Pore Size 200-300 Micron) (Thickness Of Coating 140 To 180Mm) Acetabular Hemisphericaluncemented Component With Tapered Locking Mechanism For Liner Multiple Locking Screws Options Od-38 To 64Mm With 2Mm Of Incrementacetabular Highly Crosslink Polyethylene Cup Liner (28/32/36 Mm Id) With 10° Option And Various Sizes Femoral Cement Restrictor , Femoral Cement Centerlizerdisposable Cement Gun & Pulsatile Lavage.(Uncemented Cup Size 42 To 68 Size Cup) , Thr ( Hybrid Ceramic On Poly) , Cemented Femoral Stem(Titanium Alloy, Double Tapered)- 12/14 Taper,Collarless, Reduced Lateral Shoulder Taper, Wedge Type With A Option Of Having Same Instrument Can Be Used For Cemented And Uncementedmetalmodular Head 28Mm, 32Mm, 36Mm. (12/14 Taper) With At Least 4 Variable Neck Lengthuncementedacetabular Cup Component – Titanium Porous Coated (Pore Size 200-300 Micron) (Thickness Of Coating 140 To 180Mm) Acetabular Hemispherical Uncemented Component With Tapered Locking Mechanism For Liner Multiple Locking Screws Options Od-38 To 64Mm With 2Mm Of Incrementacetabular Ceramicliner Various Sizes Femoral Cement Restrictor Femoral Cement Centerlizer Disposable Cement Gun & Pulsatile Lavage.(Uncemented Cup Size 42 To 68 Size Cup) , Revision Cemented Hip System , Revision Cemented Highly Polished Triple Taper Collar Less Stem With Length (Upto 300Mm) With Options Of Sizes From 200 – Upto 300 (Long Stem)Cemented 10 Degree Acetabular Cup With Lpw Variable Neck Length Femoral Cement Restrictor Femoral Cement Centerlizerdisposable Cement Gun And Pulsatile Lavage. , Revision Cementless Hip System , Uncementedrevisonacetabular Cup Component- Highly Scratch Fit Porous Coted Titanium Acetabular Hemispherical Uncemented Component (Size 42 Upto 68 Mm) With, Tapered Locking Mechanism For Linerlocking Screws Options Of Multi Hole ,With The Option Of Peripheral Locking Screw To Accommodate 22,28,32,36Mm Head With Same Cup, Option Of Vip Taper ,Anti Rotational Device Mechanism For Locking Of Different Type Of Liners Acetabular Highly Crosslinkedpolycup-Highly Crosslink Polyethylene Option Of Neutral,10* Lpw,Lateralized Liner Metal Head Od 28,32,36Mm Stem Must Have Fluted Tapered,Proximal Coating With Holes With Conical Implant Design Polished Distal Tip Polished Should Be In Diffrentlength Of 190,225,265 And 305 Mm With Diameter Of 12 Mm To 23 Mm) , Long Stem Uncemented Modular Bipolar , Stem Must Have Fluted Tapered ,Proximal Coating With Holes With Conical Implant Design Polished Distal Tip Polished Should Be In Diffrentlength Of 190,225,265 And 305 Mm With Diameter Of 12 Mm To 23 Mm)Cemented Femoral Stem(Titanium Alloy, Double Tapered)- 12/14 Taper,Modularity Inhead With Dif Size Option With Bipolar Cup Size From 39 To 55 Size , Reverce Hybrid Thr Cemented Cup,Metal Head , Uncemented Stemcemented Cup Which Can Accomodate 28,32,36 Heads According To Size Of Cups Metalmodular Head 28Mm, 32Mm, 36Mm. (12/14 Taper) With At Least 4 Variable Neck Lengthuncementedacetabular Cup Component – Titanium Porous Coated (Pore Size 200-300 Micron) (Thickness Of Coating 140 To 180Mm) Acetabular Hemispherical Uncemented Component With Tapered Locking Mechanism For Liner Multiple Locking Screws Options Od-42 To 68 Mm With 2Mm Of Increment (Uncemented Cup Size 42 To 68 Size Cup) , Gown , Hip U Drape , Pulselavage , Dual Cut Blade , Cotery Pencil , Skin Stapler , Cling , Stimulan 10 Cc , Stimulan 5 Cc