Tender For Repair To Walls And Painting To Certain Bldgs & Infrastructure, Improvement Of External Electric Supply And Provn Of Glow Sign Board And Repair/Maint Of Various Street Lights For Road Lighting, Fan Repair And Connected Itmes At 652 Coy Asc (Civ, hasimara-West Bengal

Military Engineer Services has published Tender For Repair To Walls And Painting To Certain Bldgs & Infrastructure, Improvement Of External Electric Supply And Provn Of Glow Sign Board And Repair/Maint Of Various Street Lights For Road Lighting, Fan Repair And Connected Itmes At 652 Coy Asc (Civ. Submission Date for this Tender is 07-07-2025. Wall construction Tenders in hasimara West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

49444510
Corrigendum : Tender For Repair To Walls And Painting To Certain Bldgs & Infrastructure, Improvement Of External Electric Supply And Provn Of Glow Sign Board And Repair/Maint Of Various Street Lights For Road Lighting, Fan Repair And Connected Itmes At 652 Coy Asc (Civ
Tender
Indian
West Bengal
Hasimara
07-07-2025

Tender Details

REPAIR TO WALLS AND PAINTING TO CERTAIN BLDGS & INFRASTRUCTURE, IMPROVEMENT OF EXTERNAL ELECTRIC SUPPLY AND PROVN OF GLOW SIGN BOARD AND REPAIR/MAINT OF VARIOUS STREET LIGHTS FOR ROAD LIGHTING, FAN REPAIR AND CONNECTED ITMES AT 652 COY ASC (CIV GT) IMTRAT UNDER GE (AF) HASIMARA; 1 M&L forpreparation old surfaces of plastered or unplasteredold decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of white/lime wash on walls including cornices, pilasters etc, complete all as specified and directed. 2 M&L forpreparation old surfaces of plastered or unplasteredold decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of white/lime wash on walls including cornices, pilasters etc, complete all as specified and directed. 3 All as per item No. 2.00 here-in-before but on ceiling surfaces, complete all as specified and directed. 4 M&L forpreparation old surfaces of plastered or unplasteredold decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of distemper oil emulsion on walls including cornices, pilasters etc, complete all as specified and directed. 5 All as per item No. 4.00 here-in-before but on ceiling surfaces, complete all as specified and directed. 6 M&L forcomplete removal ofexisting treatment fromwalls by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of oil bound distemper on walls including cornices, pilasters etc, complete all as specified and directed. 7 All as per item No. 6.00 here in before but on ceiling surfaces, complete all as specified and directed. 8 M&L for preparation of old painted wood andwooden surface any description not otherwise described and exc 10cm width or girth and applying one coat of synthetic enamel paint (1st grade quality) , complete all as specified and as directed. 9 M&L for preparation of old painted steel or iron surfaces any description not otherwise described and exc 10cm width or girth and applying one coat of synthetic enamel paint (1st grade quality), complete all as specified and as directed. 10 M&L for preparation of old painted steel or iron surfaces any description not otherwise described and exc 10cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) , complete all as specified and as directed. 11 M & L for complete removal of existing treatment and applying a coat of 1.5mm thick of wall care putty in wall etc. rubbing with sand paper to obtain smooth & plain surface, complete all as specified and directed. 12 M&L for preparation of newly applied wall surfaces wall care putty and applying two coats of distemper oil emulsion, complete all as specified and directed. 13 M&L forpreparing old surfaces of plastered or unplastered surfaces of walls by brooming down and applying one coat of cement base paint, complete all as specified and directed. 14 M&L forcomplete removal of existing treatment from plastered or unplastered surfaces including washing, rubbing down and scrapping smoke, soot, moulds, moss and greasing spots with steel wire brush and applying two coats of cement base paint, complete all as specified and directed. 15 M & L for preparing old decorated surfaces of walls and applying one coat of 100% acrylic weather proof exterior emulsion paint of approved colour and shade, complete all as specified and directed. 16 M & L for complete removal of existing wall treatment and applying two coats of acrylic weather proof exterior emulsion paint colour and pattern, complete all as specified and directed. 17 M & L for complete removal of existing wall treatment and applying two coats of plastic emulsion paint over a coat ofputtyon wall/ceiling surface with any colour and pattern, complete all as specified and directed. 18 M & L for writing letters or figures (Block, Roman, Italic or Indian) not exceeding 30cm high, complete all as specified and directed. 19 All as per item No 18.00 here-in before but stops, commas, short lines, dashes, hyphens, brackets, etc., complete all as specified and directed. 20 Taking down cement plaster on brick or concrete surfaces including racking out joints, hacking for key, scrubbing downwith water etc, complete all as specified and directed.. 21 M&L 15mm thick rendering in CM (1: 6) on fair faces of brick work or concrete surfaces finished surfaces even and smooth without using extra cement, complete all as specified and directed. 22 M & L for rendering 15mm thick in two coats (10mm under layer + 5mm top layer) on fair faces of brick work or concrete surfaces of wall in CM (1:4),mixed with water proofing compound on top layer as per manufacturers instructions and finished the surface even and fair without using extra cement, complete all as specified and directed. (Note : WPC shall be measured and paid separately) 23 Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification, complete all as directed. 24 M&L for preparing newly plastered surfaces of walls etc and applying two coats of distemper oil emulsion over a coat of alkali resitant primer, complete all as specified and directed. 25 M&L for preparation of newly plastered wall surfaces and applying two coats of cement base paint over a coat of chalkwhiting, complete all as specified and directed. 26 Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil removing shrubs, small trees height up to 1m, removing the grass from route, complete all as specified and directed.Note : (i) Rate includes all waste materials and grass not exc. 50m distance from installation, depositing where directed at a level not exceeding 1.5 metre above the starting point and cleaning of yard.(ii) Cleaning should repeat in same installation in every three months. 27 S & F in repair LED aviation light on overhead tank with light dependent sensor IP 66 protection with all electric connection, complete all as specified and directed. 28 S & F 3 corePVC insulated sheathed multistranded copper conductor cable of size 1.5 Sqmm passing through PVC conduit from junction box to fittings, complete all as specified and directed.(Note: PVC conduit shall be measured and paid seperately.) 29 Excavation in trenches n. exc. 1.5m wide and n. exc. 1.5m in deep for foundation etc. or for cable/CI/PP-R/GI pipe, shaft, wells, cesspits, manhole, pair house etc. n. exc. 10 Sqm on plan and getting out in any type of soil, complete all as specified and directed. 30 Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed. 31 Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed. 32 Supply, installation, testing and commissioning factory fabricated feeder pillar (outdoor type) weather dust and vermin proof fabricated out of 3.15mm thick CRCA steel sheet outer portion AC 415 volts, 50 HZ of size 1200mm x 600mm x 300mm mounted on PCC foundation and inner portion of size 2.0mm thick suitable size of MS channel supports and and with suitable size of angle iron legs for grouting steel sheet powder coated paint internally and externally and locking arrangementincluding all incoming and outgoing connection with suitable size of lugs and glands dismantling existing unserviceable panel and including the following:-Incoming :-(i) MCCB 160 Amp, 4 pole with adjustable thermal and fixed magnetic type - 01No. (ii) Digital Voltmeter -01 No.(iii) Digital Ammeter -01 No.(iv) Indication lamp-01 No(v) Aluminium busbar 3 phase 4 wire for rating 200 Amps for phase and neutral 04 Nos.Outgoing:- (i)MCCB 125 Amp, 4 pole with adjustable thermal and fixed magnetic type-01 No(ii) MCCB 63 Amp, 4 pole with adjustable thermal and fixed magnetic type-02 Nos. (iii) Indication lamp-01 No 33 Supply, fabricating, installation, testing and commissioning of back-lit signage boardincluding embedding the board firmly with the wall/MS angle frame/as per approved art work and nomenclature as under :- Box with frame :- 25 x 25mm square pipe (18 gauge) frame with cross supports @ spacing not exceeding 1.0m on the box length including 20mm x 20mm MS Square pipe (18 gauge) stiffeners duly painted with two coats of white synthetic enamel paint (1st grde quality) over a coat of zinc oxide iron primer, depth of box should not be less than 165mm. Side, Top, Back and bottom Panels :- Made out of 24 gauge chemically treated GI Sheets duly powder coated with white matt finish coating on both inner and outer surfaces. Top panel made out of 24 gauge chemically treated GI sheet, duly powder coated, drip cap (fixed with pop rivet or machine moulded to shape) of 25mm on front and side to prevent damages due to rain etc.The bottom panel should be provided with access door fixed with stainless steel screws and suitable housing for LED drivers.LED Module :-LED 12V module beam angle >=150 degrees with IP rating >= 64, 0.72 W/70 lumens per module of 3 LEDs with 7000 to 8000 K colour temperature.LED configuration :- 29 LED modules per Sqm (equal division on spacing based on height of box) and one module every 0.20 m on running length of box.LED power supply :-Input 230 V AC, power supply should be CPCC (constant power constant current) of 30W/60W/120 W.Graphics :-Graphics shall be computer plotter cut with translucent cast vinyl matching the colour specification of the installation. 34 M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paint complete for base support frame for watertanks at roof top/ground floor including dismantling old unserviceable cross arm of any MS section, complete all as specified and directed. 35 M &L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized wire of size 4mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part -1, including necessary excavation and earth work, P.C.C (1:3:6) type C-1 with 50mm thick Pre-cast R.C.C. (1:2:4) type B1 cover slab (reinforced with 8mm dia deformed bar 15cm C/C both ways and suitable handle of 10mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15cm compacted thickness all around the earth electrode, with funnel and 20mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, Gl earth wire protected by 15mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion including dismantling of old unserviceable earthing of any descriprtion, complete all as specified and as directed.Note : Proper earthing pit should be provided with pit cover. 36 All as per item No 35.00 here-in before but using galvanised iron strip 32 x 6mm as earting lead, complete all as specified and directed 37 Horizontal boring under the road (with manual method) below 1mtr from the road surface and dia of hole not exc 100mm, without damaging the existing road, getting out and disposal of materials to a distance not exceeding 50m from the site of work, complete all as specified and directed. 38 S&F GI tubing 80mm bore (light grade) with all fittings for protection of cables, laid in trenches including making good to the distrurbed surface,complete all as specified and directed (Note : Excavation and earth work shall be measured and paid separately) 39 S&F MCB distribution board (DB), TPN with sheet metal encloser, double door, IP 43 protection & IK 09, 240 volts, 4 way, as per IEC 61439-3 with necessary lugs for incomming and outgong connections, fixed on wall,single pole andneutral, with 200 Amps rated busbar (as per OEM), neutral link for fixing MCBs/Isolators including taking down old unserviceable MCB DB of any rating, complete all as specified and directed. 40 S&F in repair MCB Tripple Pole Neutral (TPN) of capacity 40 to 63 Amps, 415 Volts, breaking capacity 10 KA, ‘C’ series, as per IS/IEC 60898-1, fixedin proper position, complete all as specified and directed. 41 S&F in repair MCB Single Pole (SP) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, as per IS/IEC 60898-1, fixedin proper position, complete all as specified and directed. 42 S&F in replacementpost top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light, IP 65 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed. 43 S&F LED constant current driver above 45 Watt and upto 60 Watt light fittings, complete all as specified and directed. 44 S&F LED constant current driver above 60 Watt and upto 150 Watt light fittings, complete all as specified and directed. 45 Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core including taking down old unserviceable UG cable, complete all as specified and directed. 46 Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core including taking down old unserviceable UG cable, complete all as specified and directed. 47 Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core including taking down old unserviceable UG cable, complete all as specified and directed. 48 Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core including taking down old unserviceable UG cable, complete all as specified and directed. 49 Supply and laying double walled corrugated (DWC) HDPE duct pipe of 20mmdia conformingto IS, approved colour complete with fittings for cable protection, complete all as specified and directed. 50 Supply and laying double walled corrugated (DWC) HDPE duct pipe of 40mmdia conformingto IS, approved colour complete with fittings for cable protection, complete all as specified and directed. 51 Supply and laying double walled corrugated (DWC) HDPE duct pipe of 90mmdia conformingto IS, approved colour complete with fittings for cable protection, complete all as specified and directed. 52 S&F 40mm bore, GI pipe bracket, medium grade, of required length not less than 1.20m consisting mounting bracket made out of mild steel FI 40 x 6mm requied shape (two Nos. per GI pipe bracket) duli fitted with 4 Nos. mild steelnuts, bolts and washers in walls/poles etc. including painting with oneof synthetic enameled paint (1st grade quality) over a coat of red oxide primer including taking down old unserviceable GI bracket of (any shape/size) from pole, complete all as specified and directed. 53 S&F in replacement of capacitor of ceiling fans with capacitor having capacity 2.5mfd, 240 Volts, complete all as specified and as directed. 54 M & L for replacement of short circuit /over heated winding from stator of ceiling fan of any make having 1200mm sweep with matching gauge and turns of super enamelled copper winding wire complete with leathered paper, glass sleeves, varnishing, baking, heating, drying, cleaning fan bearing/bushes, greasing, oiling, complete re asssembling of ceiling fan with testing etc including taking down old unserviceable one, complete all as specified and directed. 55 M & L for disconnecting burnt end or portion of UG cable, removing the cable from loop including necessary excvation and earth work, relaying and reconnecting the cable by removing burnt portion of cable and preparing fresh terminal for cable of cross sectional area 10 Sqmm 2 core to 95 Sqmm 3.5 core of LT cable to pole, main switch, LT panel etc, complete all as specified and directed. 56 S&F in repair KIOSK box weather proof made out of PVC and including one piece mounted SMC base and door pole mounted hinged door size 333 x 233 x 200mm out side and 300 x 200 x 105mm inside dimension comprising of aluminum bus bar 4 strips for 3 phase and neutral 63 Amp and 10 Amp MCB for controlling the street light fitting including FI clamps 30 x 4mm with necessary MS nuts bolts and washer including embossing/painting of danger notice of size not less than 10cm x 7.5 cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body, complete all as specified and directed. 57 S&F LED street light fittings 60 watt 230 v AC outdoor type with high pressure dia cast aluminium housing and heat-resistant complete with driver, lamp bracket with impact and corrision resistant, IP 65/66 protection including taking down old unserviceable LED light fittings, complete all as specified and directed. 58 S&F LED street light fittings 70/72 watt 230 v AC outdoor type with high pressure dia cast aluminium housing and heat-resistant complete with driver, lamp bracket with impact and corrision resistant, IP 65/66 protection including taking down old unserviceable LED light fittings, complete all as specified and directed. 59 S&F LED street light fittings 90 watt 230 v AC outdoor type with high pressure dia cast aluminium housing and heat-resistant complete with driver, lamp bracket with impact and corrision resistant, IP 65/66 protection including taking down old unserviceable LED light fittings, complete all as specified and directed. 60 S&F LED street light fittings 120 watt 230 v AC outdoor type with high pressure dia cast aluminium housing and heat-resistant complete with driver, lamp bracket with impact and corrision resistant, IP 65/66 protection including taking down old unserviceable LED light fittings, complete all as specified and directed. 61 M & L for LED constant current driver for 45 watt light fittings, complete all as specified and directed. 62 Note: An amount of Rs.22,750.00 on account of Credit Schedule for schedule A part - II shall be deducted from the total amount of BOQ to arrive at the contract sum. 63 Supply and fixing energy efficient ‘LED Flood Light120 W LED luminairewith Aluminium dia cast housing, toughened glass cover with IP 66 protection, CCT 5700 K including fixing arrangment on wall/pole / surface and connecting cable up to nearest ceilign rose into flexible PVC conduit. Make : Crompton/Havells/ Surya/Philips

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 03-07-2025 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 07-07-2025
2 11-06-2025 CORRIGENDUM TO BOQ BOQ 21-06-2025
3 21-06-2025 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-06-2025
4 28-06-2025 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-07-2025

Key Value

Document Fees
INR 500 /-
EMD
INR 56000.0 /-
Tender Value
INR 28 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail