| 1 | Taking down carefully copper/aluminium point wiring complete (light,fan, plug point & power complete alongwith fittings (switches, ceiling roses, tube light fittings, bulk head fitting regulator, sockets main switches, DB removing materials to store & making good of disturb surfaces of wall/floors etc complete all as specified & directed. |
| 2 | M& L for Point wiring with 1.5 Sqmm PVC insulated andunsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLSH type drawn through and including PVC casing caping/conduit (ISI marked) of adequate size and its accessories with sunk cast iron/pressed steel terminal boxes of size 1.2 mm thick,one light or one fan point controlled by one switch incl 1.5 Sqmm (nominalarea) copper conductor cable (multistrand), FRLSH type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metalic bodies of luminaires/ fan at other end complete all as specified and directed for the following:- |
| 3 | One light point / one fan point controlled by one, one way swtich. |
| 4 | All as per item No 2.0 here in before but for one 5 Amp 5 pin socket outlet point on same board with other switches including earth wire complete all as specified & directed. |
| 5 | All as per ser item No 2.0 here in before but on independent board complete all as specified & directed. |
| 6 | All as per ser item No 2.0 here in before but with 2.5 SqmmPVC copper stranded cable FRLS type for one 15 Amp 6 pin socket outlet point including PVC cable 2.5 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to commen earth & earth terminals including boards for mounting purposes complete all as specified & directed. |
| 7 | All as per ser item No 2.0here in before but one light point controlled by 2 way switches complete all as specified & directed. |
| 8 | All as per ser item No 2.0here in before but one bell/buzzer point controlled by one push button on the same board with other switches or independent complete all as specified & directed. |
| 9 | Supply and fixing in replacement of switch piano flush button 5 Amp single pole one way 230 volts white finish complete all as specified & directed. |
| 10 | Supply and fixing in replacement of bell push, 230 volts white finish complete all as specified & directed. |
| 11 | Supply and fixing in replacement of bell ding dong type AC, 230 volts, single phase complete all as specified and directed. |
| 12 | Supply and fixing in replacement of step type fan regulator complete all as specified and directed. |
| 13 | Supply and fixing in replacment of ceiling rose of size (65x50) mm surface bakelite 240 Voltsthree terminal complete all as specified & directed. |
| 14 | Supply and fixing in replacement angle type Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 15 | Supply and fixing in replacement switch socket combination 2 in 1, 5 pin, 6 Amps flush type complete all as specified & directed. |
| 16 | Supply and fixing in replacement switch socket combination 3 pin , 16 Amp flush type,complete all as specified & directed. |
| 17 | Supply and fixing in replacement of switch piano flush button 5 Amp single pole 2 way 230 volts white finish complete all as specified & directed. |
| 18 | M&L for point wiring complete as specified with 1100 V grade with 1.5 Sq mm single core PVC insulated unsheathedFRLSHcable, copper conductor multistrandedpassing through including pvc concealed conduitwith concealed modularboxsuitable for logic modular switches , sockets , etc and logic modular white plates, sorroundingsof suitable sizeas required atsitewith PVC insulated FRLSHunsheathedstranded copper conductor of size 1.5 sq mmas earth wireconnected to common earthdully as specified complete all as specified and directed for the following:- Note: - (i) Rate quoted shall include for cost of making MS box and concealed in wall including cutting and sinking of boxes and making good tothe walls (No extra payment will be made for the same)(ii) Provision of blank plates shall be included in quated rate, as per site requirement (No extra payment will be made for the same) |
| 19 | One light point / one fan point controlled by one, one way swtich complete all as specified & directed. |
| 20 | All as per item No 12 here in before but for 5 Amp switch socket on the same board complete all as specified & directed. |
| 21 | All as per item No 12 here in before but for 5 Amp switch socket on independent board complete all as specified & directed. |
| 22 | All as per item No 12 here in before but size of cable 4sq mm with earth wire of 4sq mm complete all as specified & directed. |
| 23 | Alas per item no 12.0 here in before but for 2 way point wiring with cable of size1.5 sq mm with 1.5 sq mm earth wire suitable forlight points at stair case.( Staircase lights) complete all as specified & directed. |
| 24 | All as per ser item No. 12.0here in before but one bell/buzzer point controlled by one push button on the same board with other switches or independent complete all as specified & directed. |
| 25 | Supply and fixing Switch modular type, single pole, one way, 5/6 Amp, one module, complete all as specified & directed. |
| 26 | Supply and fixing Switch modular type, single pole, 2 way, 5/6 Amp, one module, complete all as specified and directed. |
| 27 | Supply and fixing Switch modular type, single pole, one way, and 15/16 Amps, one module complete all as specified & directed. |
| 28 | Supply and fixing socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, two module, modular type complete all as specified and directed. |
| 29 | Supply and fixing socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin 5/6 Amp, modular type complete all as specified and directed. |
| 30 | Supply and fixing Switch modular type, single pole, Bell push, 5/6 Amp, one module, complete all as specified and directed. |
| 31 | Supply and fixing Fan Step Regulator modular type, two module,complete all as specified and directed. |
| 32 | Supply & Fixing in repair Modular White cover plate with frame, 2 modulecomplete all as specified and as directed. |
| 33 | Supply & Fixing in repair Modular White cover plate with frame, 4 modulecomplete all as specified and as directed. Make :- Carbtree/Legrand/Indo Asian/C&S. |
| 34 | Supply & Fixing in repair Modular White cover plate with frame, 6 modulecomplete all as specified and as directed. Make :- Carbtree/Legrand/Indo Asian/C&S. |
| 35 | Supply & Fixing in repair Modular White cover plate with frame, 8 modulecomplete all as specified and as directed. Make :- Carbtree/Legrand/Indo Asian/C&S. |
| 36 | Supply & Fixing in repair Modular White cover plate with frame, 12 modulecomplete all as specified and as directed. Make :- Carbtree/Legrand/Indo Asian/C&S. |
| 37 | Supply & Fixing in repair Modular Metal flush box 2 module complete all as specified and as directed. Make :- Carbtree/Legrand/Indo Asian/C&S. |
| 38 | Supply & Fixing in repair Modular Metal flush box 4 module complete all as specified and as directed. Make :- Carbtree/Legrand/Indo Asian/C&S. |
| 39 | Supply & Fixing in repair Modular Metal flush box 6 module complete all as specified and as directed. Make :- Carbtree/Legrand/Indo Asian/C&S. |
| 40 | Supply & Fixing in repair Modular Metal flush box 8 module complete all as specified and as directed. Make :- Carbtree/Legrand/Indo Asian/C&S. |
| 41 | Supply & Fixing in repair Modular Metal flush box 12 module complete all as specified and as directed. Make :- Carbtree/Legrand/Indo Asian/C&S. |
| 42 | Supply and fixingin repair building securitylighting ofLED 35watts high efficennt lighting solutionanodisedwith heat resistance with accessoriesprovidedincluding necessary electric connection with all accessories required for fixing/mounting with nut bolt washer & clamp support on GI pipe1.5 meters long of suitable diametercomplete all as specified and as directed. Make-Cat No:ENDCITYLITPLAT+SL35WLED757 SASYBOPCWOSPD make of Havells or equivalent in make in Crompton/Syska. |
| 43 | Supply and fixing in repairs Aviation yellow painted die-cast aluminium alloy housing, red coloured polycarbonate dome and accessories including suitable dia GI pipe for fixing of light with all fixing arrangementincluding PCC, electrical connections complete all as specified and as directed. Make : Cat No 24973 BJAOL 2 BC make ofBajaj or equivalent make as approved by GE. |
| 44 | Supply & fixing inLED tube 20 W Tube light fitting LED Batten with aluminum housing and integrated electronic driverwith square profile extruded connecting up with three core flexible copper conductor cable of suitable size from ceiling rose up to 1.5m length complete all as specified and as directed.Make: Havells/Philips/Wipro |
| 45 | Supply & fixing inLED 9/10 W Tube light fitting LED Battenextrudedand polycarbonate connecting up with three core flexible copper conductor cable of suitable size from ceiling rose up to 1.5m length complete all as specified and as directed.Make-Havells/Philips/Wipro |
| 46 | Supply and fixing of LED 36 Watt recessed mounted fitting, energy efficient, decorative type suitable for armstrong/grid ceiling, with its super bright LED complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.Make- Cat Part No.VENUSNEO2X2PLR36WLD 857G2make of Havellsor equivalent in make in Wipro/philips |
| 47 | Supply and fixing in repacemnt MCB DB double door with necessarylugs for incomming and outgong connections up to Copper/Aluminium conductor og 16 sq mm fixed on wall surface/concealedafter taking down the existing DB of any make/ rating from any height for the following Way |
| 48 | MCB DB SPN4WayMake : Legrand/ L & T/Indo Asian/Standard |
| 49 | MCB DB SPN8WayMake : Legrand / L & T/Indo Asian/Standard |
| 50 | MCB DB SPN12WayMake : Legrand / L & T/Indo Asian/Standard |
| 51 | MCB DB TPN 4way Make : Legrand/ L & T/Indo Asian/Standard |
| 52 | Supply andfix in replacementMCB of following rating complete all as specified and directed.Make: Legrand/L &T/ Standard Havell\"s |
| 53 | MCB SP6 to 40 Amp |
| 54 | MCB DP/SPN6 to 40 Amp |
| 55 | MCB TP6 to 40 Amp |
| 56 | MCB TPN 40 to 63 Amp |
| 57 | S&F VTPN prewired distribution board TPN-DPX 160 MCCB including one No MCCB 160 Amps as incomer and suitable SPN/TP MCBs as outgoing double door type sheet metal enclosure 415V with 200 Amps rated standard busbar of suitable size plate and common neutral link without MCBs with blank plate suitable for 6 way complete all as specified and as directed.Make: Cat Part No. 5077 5712 wayDPX³ 250+36 of make of Legrand or equivalent in make in Schneider/ABBNote : Rates of MCCB and MCB SPN/SP/TP shall be paid under respective item |
| 58 | Supply and laying or fixing inreplacementtwinsub maincable with (2 x 4) Sqmm multistrand PVC insulated unsheathedcopper conductorPVC cable including continouse earth wire (1 x 4) Sqmm copper conductor insulatedunsheathed complete all as specified and directed as following:- |
| 59 | In PVC concealed conduit |
| 60 | In PVC casing caping |
| 61 | Supply and laying or fixing inreplacementtwinsub maincable with (2 x 6) Sqmm multistrand PVC insulated unsheathedcopper conductorPVC cable , in pvc casing caping including contineous earth wire (1 x 6) Sqmm copper conductor insulatedunsheathed complete all as specified and directed: |
| 62 | In PVC concealed conduit |
| 63 | In PVC casing caping |
| 64 | S & F in replacement of PVC rectangular block of sizes of following size for mountingswitches, sockets, fan regulator, etc bypunching required slots for switches/Sockets /Regulators as per site requirementincluding taking down the existing metal/PVC/Wodden boxes with back and top complete all as specified and directed. |
| 65 | 100 mm X100 mm square,50 mm deep |
| 66 | 175mmX100 mm , 50 mm deep |
| 67 | 200mmX150 mm, 50 mm deep |
| 68 | 250mmX200mm50 mm deep |
| 69 | M&L industrial laminated sheet board/hylem sheetof size 6 mm thick of anysize forfor mountingswitches, sockets, fan regulator, etc bypunching required slots for switches/Sockets /Regulators as per site requirement including taking down the existinglaminated top cover complete all as specified and directed. |
| 70 | Supply and fixing in replacement 15 Amps 3 pin plug topcomplete all as specified and directed. |
| 71 | Supply and fixing in replacement 5 Amps 3 pin plug top complete all as specified and directed. |
| 72 | Supply and fixing in power unit up to 25 Amps including sockets 25 Amps, 04 module box for mounting of power unit and power socket complete as specified and directed power unit complete all as specified and directed. Make - Legrand/Havells/Anchore. |
| 73 | Comprehensive repair/maintenance of storage type electric heater (geyser) vertical/horizontal type of capacity 25/50 ltrs comprising of the following works complete all as specified and directed:-(a) Inspection, taking down or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank upto the entire satisfection of Engr-in-Charge(b) Checking of all stop cock, pressure release valve, fusible plug etc to ensure free functioning of the parts including Supply and replacement of washer/gasket, nuts etc as required.(c) Inspect overflaw and vent pipes and remove blockages (if any)(d) Checking and rectify earth continuity of the electrical circuits of the geyser and power points(e) Check, maintain and re-fixing thermostat and re-adjust(f) Visual examination of of fusible plugs for its serviceability(g) De-scaling the immersion type heating element and siphon assembly with diluted hydrochloride acid or cear pedette solution(h) Checking of indicator lamp for its serviceability(j) Re-assembling the geyser, re-installed and testing complete(Note: (i) Spare parts/components of geysers shall be measured and paid seperately as \"supply only\" under respective items here-in-below. (ii) Any minor parts required for smooth functioning of the geyser shall be provided by the contractor without any extra cost to the Govt.) |
| 74 | Supply only heating element, 2KW capapcity, AC 230 volts, pressed/screw/ triangular/ ceramic type, ISI marked complete all as specified and directed. |
| 75 | Supply only heating element, 1.5KW capapcity, AC 230 volts, pressed/ screw/triangular/ ceramic type, ISI marked complete all as specified and directed. |
| 76 | Supply only thermostate element type EST, 11/20 Amp 250 Volt ISI Marked complete all as specified and directed. |
| 77 | Supply only thermostate element type EST, 7/15 Amp 250 Volt ISI Marked complete all as specified and directed. |
| 78 | Supply only hot and cold flexible pipe, high pressure with both end brass adopter 18\" long ISI marked complete all as specified and directed. |
| 79 | Supply onlyPVC inlet connector pipe 450mm long for geyser, heavy duty,with brass coupling both endssutiable to fix inlet of geyser complete all as specified and directed. |
| 80 | Supply only porclain Heating Element ceramic type suitable for 2 KW geeyser complete all as specified and directed. |
| 81 | Repairing / testing Ceiling fan 1200/1400 mm sweepincluding rewinding, bush, bearing and fan blade suitable for 240V, ISI marked, 50HZ with regulator complete with all accessories and connection as per manufacturer instruction complete all as specified and directed . Note-1)all fans must have 1.5 Sq mm copper cunductor multicore twin twisted wire of 01 Mtr length 2) Spare parts should be measured and paid separately . |
| 82 | Supply only capacitor of capacity 2.5/4 mfd complete all as specified and directed. |
| 83 | Supply only Gun Metal bush suitable for any type of fan complete all as specified and directed. |
| 84 | Supply only ball bearing of No. 6200/ 6201/ 6202/ 6203 complete all as specified and directed. |
| 85 | Repairing / testing exhaustfan/wall mounted fan upto 600 mm sweepincluding rewinding, bush, bearing and fan blade suitable for 240V, ISI marked, 50HZwith all accessories and connection as per manufacturer instruction complete as directed . Note-1)all fans must have 1.5 Sq mm copper cunductor multicore twin twisted wire of 01 Mtr length 2) Spare parts should be measured and paid separately . |