Tender For Supply Installation Testing And Commissioning Of Silent Type Diesel Generator Set Along With Amf Panel And Required Accessories Of Capacity 140 Kva At Bg Dhand As Per The Latest Cpcb Iv Plus Norms 3Rd Call

Issued by Boards / Undertakings / PSU · dhand, Haryana
Tender Value
22.64 Lakhs
Estimated cost
Bid Submission
10 Jun 2025
0 days left
EMD
45285
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
dhand → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply Installation Testing And Commissioning Of Silent Type Diesel Generator Set Along With Amf Panel And Required Accessories Of Capacity 140 Kva At Bg Dhand As Per The Latest Cpcb Iv Plus Norms 3Rd Call

BOQ

Name of Work:Supply, installation, testing and commissioning of Silent type Diesel Generator set along with AMF panel and required accessories of capacity 140 kVA at BG Dhand as per the latest CPCB IV+ norms.(3rd Call)
Sl. No. Item Description
1Fabricating and supplying ‘Silent Type\" CPCB IV+ norms compliant Diesel Generating set alongwith Prime Power Rating of specified kVA as mentioned below depot wise, 415 voltsat 1500RPM,0.8 laggingpowerfactor at415Vsuitablefor50Hz,3 phasesystemandconsistingofthe followings as per OEM standards (a) Diesel Engine:CPCB IV+ compliant Dieselengine with 4 cylinder, 4strokewatercooled ,electric start, of minimum specified BHP as mentioned below depot wise at 100% Load factor at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH&at1000MeterMSLandconformingto BS 5514, BS 649, IS 10000 (with latest ammendments), capableof taking 10% over loading for one hour after 12 hours of continuousoperation.The enginewill be fitted complete with all the required accessories with charging alternator and battery charger.(b) Engine mounted Instrument Panel fitted with and having digital display for following:(i)Start-stop switch with key(ii) Water temperature indication(iii)Lubrication oil pressure indication(iv)Lubrication oil temperature indication(v) Battery charging indication(vi)RPM indication(vii)Over speed indication(viii) Low lubricant Oil trip indication(ix)Engine Hours indication(c) Alternator :Synchronous alternator rated at specified kVA as mentioned below depot wise, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging powerfactorat 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shallbehavingSPDPenclosure,brushless, continuous duty, self-excited and self-regulated through AVRconformingto IS:4722/BS2613 (with latest ammendments) for tropicalconditionsandwith class-H insulation.(d) Base Frame & Foundation:Both the engine and alternator shall be mountedon suitablebaseframe madeof MS channelwithsuitable amount ofreinforcement which shall be installed on suitablecementconcrete foundationand vibration isolationarrangement as per recommendations of manufacturer. (e) Fuel Tank:Dailyservicefueltank capable of giving minimum continuous run of 8 hours, fabricated out of minimum2 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MSclass\"C’ pipesofsuitabledia.Complete with valves,level indications&accessories as required as per CPWD specifications/OEM standards(f) Exhaust System:Dryexhaust manifold with exhaust silencer and Diesel Oxidation Catalyst.(g) Starting System:12VDCstartingsystem comprising ofstartermotors,voltage regulatorand arrangementfor initial excitation complete with suitable AH capacity battery (lead acid type) as required as per OEM standards.(h) Accousticandweatherproofenclosurewith arrangement for fresh air intake for cooling of the engine& alternator,extraction,discharging hot air in to the atmosphere as per CPWD specifications/OEM standards
2Prime Power rating 140 kVA, 175 BHP Diesel Engine, 140 kVA Alternator at BG Dhand
3Fabricating and supplying automatic mains failure control including auto by-passpanel,suitablefor specified kVA as mentioned below depot wise silent typeDGset completewith relays,timers,set ofCTsformetering&protectionandenergy analysertoindicatecurrents,phaseandline voltages,frequency,powerfactor, kWh, kVARh& provisionforoverload,short Circuit, restrictedearthfault,underfrequency,control cablingfrom AMFpaneltodiesel engineand elsewhereifrequired,allcompleteandinter locking including the following as per OEM standards:(a) 2Nos. of specified Amp. 3poleMCB/MCCB as mentioned below depot wise(b) Auto/Manual/Off selector switch(c) 2 Nos. over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay(d) 3 Sets of current transformers 15 P 10 accuracy protection and 15 VA class-I for metering(e) Energy analyser unit to indicate current voltage frequency power factor and kWh(I) Indicating lamps for load On mains and load on set(g) Fuse for instruments(h) Battery charger,complete withtransformer/ rectifier,D.C. voltmeter and ammeter, selector switchfortrickle,offandboostandcurrent adjustment.(i) Main supply failure monitor(j) Supply failure timer(k) Restoration timer(I) Control unit with three impulse automatic engine start/stop and failure to start lockout.(m) Impulse counter with locking and reset facility.(n) ON/OFF/Control circuit switch with indicator(o) Audio/Video annunciation for(i)High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv)Engine fails to start(v) Full load/maximum load warning
4Prime Power rating 140 kVA, 250 A MCCB at BG Dhand
5Construction of cement concrete floor / foundation PCC (1:2:4, M-20 grade) foundation of weight 2.5 times the operating weight of the Genset with enclosure or as recommended by the Genset manufacturer OEM/OEA, whichever is higher. The foundation should be min 300 mm high from the ground level. The length and breath of foundation should be at least 250mm more on all sides than the size of the enclosure comprising of following:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 fine sand derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) as sub-base foundation.
6At BG Dhand
7Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm. On plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m as directed by Engineer-in-Charge
8At BG Dhand
9Centering and shuttering including strutting, propping etc. and removal ofform for foundations, footings, bases of columns, etc, for mass concrete
10At BG Dhand
11Providing and laying in position cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) as foundation for the DG set.
12At BG Dhand
13Structural steel work riveted, bolted or welded in built up section, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coating of approved steel primer all complete.
14At BG Dhand
15Providingandfixingprecoatedgalvanisedironprofilesheets(size,shapeandpitchof corrugationasapprovedbyEngineer-in-Charge)oftotalcoatedthickness0.50mm(base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
16At BG Dhand
17Providingandfixingprecoatedgalvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screwscomplete:Ridges plain (500-600 mm)
18At BG Dhand
19Providing and laying in position cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) for the foundations of the steel struts.
20At BG Dhand
21Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required..
22At BG Dhand
23Providing and fixing 25 mm X 5 mm GI strip in 40 mm dia G.I. pipe from earth electrode including connection with GI nut, bolt, spring, washer excavation and re-filling etc. as required.
24At BG Dhand
25Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
26At BG Dhand
27Supply of PVC insulated and PVC sheathed XPLE power cable of 1.1 KV grade armoured UG aluminium conductor cable conforming to IS 7098 part 1 with up-to-date amendment of the following size as required.
28CABLE SIZE 3½ X 150 SQ.MM at BG Dhand
29Supply of PVC insulated and PVC sheathed XPLE LT control cable of 1.1 KV grade armoured copper conductor cable conforming to IS 7098 part 1 with up-to-date amendment of the following size as required. CABLE SIZE 10 x 2.5 SQ.MM
30At BG Dhand
31Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
32Above 95 sq. mm and upto 185 sq. mm. (clamped with 25x3mm MS flat clamp) at BG Dhand
33Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
34Above 95 sq. mm and upto 185 sq. mm. at BG Dhand
35Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. .direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.
3691 mm dia (OD-90 mm & ID-76 mm nominal) at BG Dhand
37Installation testing and commissioning of DG set of specified kVA and suitable AMF panel as mentioned below depot wise with all the necessary electrical connections as required.
38140 kVA at BG Dhand

AI Tender Summary

OUR REF NO 49442566
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 22.64 Lakhs
LAST DATE 10-06-2025
Authority
Authority Name Food Corporation Of India
Work Description Supply Installation Testing And Commissioning Of Silent Type Diesel Generator Set Along With Amf Panel And Required Accessories Of Capacity 140 Kva At Bg Dhand As Per The Latest Cpcb Iv Plus Norms 3Rd Call
Basic Detail
Tender No EE/29/2025-26
Bidding Type Tender
Location
City dhand
State Haryana
Key Dates
Publish Date 31 May 2025
Submission Date 10 Jun 2025
Open Date 11 Jun 2025
Finance
Tender Value 22.64 Lakhs
Tender Fee Ref. Documents
EMD 45285
Exemption Not Available
Document List
3e2d25e1-a43e-4726-93ba-8e62c2fc702f.html
BOQ_907018.xls
MTF.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 31, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 10, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 11, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

3e2d25e1-a43e-4726-93ba-8e62c2fc702f.html

xls

BOQ_907018.xls

pdf

MTF.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders