|
| 1 | BOQ |
| 2 | Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect(UPPWD-2018/SI.No.647) |
| 3 | Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Double arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect.(UPPWD-2018/SI.No.648) |
| 4 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 85 watt to 90 Watt. Confirming to IP66 Protection complete in all respect. (Cat-AA).(UPPWD-2018/SI.No.1423) |
| 5 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.(UPPWD-2018/SI.No.501) |
| 6 | 16 sq. mm 4 core (i) |
| 7 | 50 sq. mm 3-1/2 core (L) |
| 8 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed. underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer Incharge.(UPPWD-2018/SI.No.503) |
| 9 | 50 sq. mm 3-1/2 core (L) |
| 10 | Supply and fixing of plain or pin type copper tin plated . cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge.(UPPWD-2018/SI.No.504) |
| 11 | 16 sq. mm |
| 12 | 25 sq. mm |
| 13 | 50 sq. mm |
| 14 | Numbering of poles with combination of yellow and black colour paint etc. complete in all respect as per direction of the Engineer-Incharge at SITE(SOR 42/FTS No.128181) |
| 15 | Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.1. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also).(UPPWD-2018/SI.No.702) |
| 16 | S/L of 90 mm dia DWC pipe for drawing of power cable across the road by drilling of 120 mm dia at 1 mtr. below the road level thereby doing the work of providing DWC pipe by trenchless method (SOR 53 FTS No.128181) |
| 17 | S/F of G.I. pipe 100 mm dia \"B\" class ZINDAL / TATA make including required material T&P etc. complete in all respect as per direction of the Engineer-Incharge at SITE (SOR 37/FTS No.128181) |
| 18 | S/F of MS rod for earting with 2.5 m long solid, 20 mm dia hot dipped galvanised MS rod buried till the top reaches 1.7 mtr. Below the GL complete with bolts & nuts & Gl earth wide 7/14.(SOR 41/FTS No.128181) |
| 19 | Supply and Wiring of submains with two nos. of 2.5 sq. mm.FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of the work as directed at site by Engineer in charge(UPPWD-2018/SI.No.289) |
| 20 | Supply and laying of 32 mm x 6 mm G.l. strip from earth electrode directly in the ground as required complete in all respect.(UPPWD-2018/SI.No.717) |
| 21 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. 140 Α ΤΡΝ(UPPWD-2018/SI.No.807-F(ii) |
| 22 | Part-2 |
| 23 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 85 watt to 90 Watt. Confirming to IP66 Protection complete in all respect. (Cat-AA)(UPPWD-2018/SI.No.1423) |
| 24 | Supply, delivery, testing, laying of Al. conductor HDPE /XLPE insulated 1100 V grade Arial Bunched Cable with Massenger wire as below on pole complete in All respect.(FTS134717) |
| 25 | 2C x 25 Sqmm. + 25 Sqmm. Massengewire |
| 26 | S/E of 410 SP-55, 11 Mtr. Long Steel Tubular Pole with 1/6 Over all length of pole groute with cement concrete in 1:3:6 (1 cement: 3 coarse 6 Stone ballas) including plinthing of pole 30 cm above the ground level, plastring of plinth including excavation back filling etc. The rates includes all materials labour & T&P. etc. required for proper completion of work as per direction of E/I.(GNIDA-2010/SOR 21(D) |
| 27 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.(UPPWD-2018/SI.No.501) |
| 28 | 16 sq. mm 4 core (i) |
| 29 | 25 sq. mm 3-1/2 core (j) |
| 30 | Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge.(UPPWD-2018/SI.No.504) |
| 31 | 16 sq. mm (d) |
| 32 | 25 sq. mm (e) |
| 33 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. 40 Α ΤΡΝ (UPPWD-2018/SI.No.807-F(ii) |
| 34 | Supply and wiring of submains with 2 nos. 2.5 sq mm & with 1 no earth wire of 1.5 sq mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing PVC conduit complete, including supply of all material, labour and T & P etc. required for proper completion of the work as directed by Engineer in charge.(UPPWD-2018/SI.No.291) |
| 35 | Supply & erection of \"D\" clamps of 50 mm x 6mm flat iron on steel tubular poles / steel rail poles with bolts, nuts etc. complete in all respects including painting with aluminium paint.(UPPWD-2018/SI.No.623) |
| 36 | Supplying and fixing of 40 mm dia 1.5 Mtr long G.I. pipe (\"B\" class) bracket with two nos. D Clamps 50 x 6 mm flat iron on steel tubular pole / steel rail pole / PCC pole with bolt, nuts etc. Complete in all respects.(DSR-E&M-2018/SI.No.11.6.2) |
| 37 | Supply & fixing of 75 mm x 90 mm shackle insulator /100 mm x 65 mm pin insulator including G.I. Bolts /spindle nuts etc. complete in all respect. (PS 2018/620)(UPPWD-2018/SI.No.620) |
| 38 | Dismantling of 70 watt LED Street Light Fitting. as required (PS 1422/2018)(UPPWD-2018/SI.No.634) |
| 39 | Fixing of 70 watt LED Street Light Fitting, as required (PS 1422/2018)(UPPWD-2018/SI.No.634) |
| 40 | Supply and burying of 600mm x 600mm x 6mm G.I. . plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also).(UPPWD-2018/SI.No.702) |
| 41 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect(UPPWD-2018/SI.No.716) |
| 42 | Supply and fixing of heavy duty cadmium plated copper connector with end plate complete in all respect.(UPPWD-2018/SI.No.1128-a) |
| 43 | Two way connector HKM 100 |
| 44 | S/F of Sintex type Junction Box of Size 338X304X170mm with hinges and locking arrangement & M.S. clamp made of 50x6 mm Flat, complete in all respect including 2 Nos. G.I. pipe 1.5\" dia having 1.0 meter length each and chuck nut for cable connection etc. as per direction of E/I(GNIDA-2010 SOR 44) |
| 45 | Numbering of Poles with combination of yellow and black colour paint etc. complete in all respects as per direction of E/l at site. (SOR 42 /)(GNIDA-2010 SOR 42) |
| 46 | Part-3 |
| 47 | Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect(UPPWD-2018/SI. No.647) |
| 48 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 35Watt. to 40 Watt. Confirming to IP 66 protection complete in all respect (Cat-AA)(UPPWD-2018/SI.No.1420) |
| 49 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.(UPPWD-2018/SI.No.501) |
| 50 | 16 sq. mm 4 core (i) |
| 51 | 16 sq. mm 4 core (i) |
| 52 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer Incharge.(UPPWD-2018/SI.No.503) |
| 53 | 16 sq. mm 4 core (i) |
| 54 | 50 sq. mm 3-1/2 core (L) |
| 55 | Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge.(UPPWD-2018/SI.No.504) |
| 56 | 16 sq. mm |
| 57 | 25 sq. mm |
| 58 | 50 sq. mm |
| 59 | Numbering of poles with combination of yellow and black colour paint etc. complete in all respect as per direction of the Engineer-Incharge at SITE(SOR 42/FTS No.128181) |
| 60 | Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also).(UPPWD-2018/SI.No.702) |
| 61 | S/L of 90 mm dia DWC pipe for drawing of power cable across the road by drilling of 120 mm dia at 1 mtr. below the road level thereby doing the work of providing DWC pipe by trenchless method(SOR 53 FTS No.128181) |
| 62 | S/F of G.I. pipe 100 mm dia \"B\" class ZINDAL / TATA make including required material T&P etc. complete in all respect as per direction of the Engineer-Incharge at(SOR 37/FTS No.128181) |
| 63 | S/F of MS rod for earting with 2.5 m long solid, 20 mm dia hot dipped galvanised MS rod buried till the top reaches 1.7 mtr. Below the GL complete with bolts & nuts & Gl earth wide 7/14.(SOR 41/FTS No.128181) |
| 64 | Supply and wiring of submains with 2 nos. 2.5 sq mm & with 1 no earth wire of 1.5 sq mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing PVC conduit complete, including supply of all material, labour and T & P etc. required for proper completion of the work as directed by Engineer in charge(UPPWD-2018/SI.No.291) |
| 65 | Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect.(UPPWD-2018/SI.No.717) |
| 66 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. 140 Α ΤΡΝ(UPPWD-2018/SI.No.807-F(ii) |
| 67 | Part-4 |
| 68 | Supply & fixing of 25 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 4 mm. Top dia minium 150 mm, Bottom dia 460 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 8 to 12luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 8 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect.(UPPWD 2018/SI.No.654) |
| 69 | Supply & fixing of 16 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip, heaving pole sheet thickness 3 mm. Top dia minium 150 mm, Bottom dia 360 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 12 5 Nos. luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect(UPPWD 2018/SI.No.652) |
| 70 | Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 200 Watt. Confirming to IP 66 protection complete in all respect (Cat-AA)(UPPWD 2018/SI.No.1455) |
| 71 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.(UPPWD 2018/SI.No.501) |
| 72 | 16 sq. mm 4 core (i) |
| 73 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer Incharge.(UPPWD 2018/SI.No.503) |
| 74 | 16 sq. mm 4 core (i) |
| 75 | Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc complete in all respect as per direction of the Engineer-Incharge.(UPPWD 2018/SI.No.504) |
| 76 | 16 sq mm |
| 77 | Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia GI pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia GI pipe up to switch board (from appron to switch board the cost of G.I pipe and GI wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also)(UPPWD 2018/SI.No.702) |
| 78 | S/L of 90 mm dia DWC pipe for drawing of power cable across the road by drilling of 120 mm dia at 1 mtr. below the road level thereby doing the work of providing DWC pipe by trenchless method(SOR 53 FTS No.128181) |
| 79 | S/F of GI pipe 100 mm dia \"B\" class ZINDAL / TATA make including required material T&P etc. complete in all respect as per direction of the Engineer-Incharge at(SOR 37/FTS No.128181) |
| 80 | Supply and wiring of submains with 2 nos. 2.5 sq mm & with 1 no earth wire of 1.5 sq mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing PVC conduit complete, including supply of all material, labour and T & P etc. required for proper completion of the work as directed by Engineer in chargeUPPWD 2018/SI.No.291) |
| 81 | Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect.(UPPWD-2018/SI.No.717) |
| 82 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive - alkalı and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. 140 Α ΤΡΝ(UPPWD 2018/SI.No.807-F(ii) |
| 83 | Labour Cess and GST will be paid extra as per govt. orders |