| 1 | Notes : (i) The work consists of 01 job as under:- JOB (A) : MAINT GRANT 2025-2026 (ii) Please refer schedule \"A\" notesbefore quoting the tender.(iii) Amount of Schedule of Credit shall be deducted off line by the department. |
| 2 | M & L for cleaning ,de-siltingand testing of manholes, septic tanks of any sizen.exc 1.50m deep by pumping manually with required rope, buckets and ladders anddepositing the sludge at distance n.exc 50mtr and then removing sludge outside MD land area complete all as specified and directedNote : The conractor shall remove the sewage / sludge and other foreign material from the site by mechanical equipment etc by or other any mean to outside MOD land in covered Vechiles i.e Vechile required for transformation of foul matters / gas etc and shall be disposed off as directed. The site shall be left by the contractor in neat and tidy condition before claiming his payment |
| 3 | All as per item No 1.01 above but depth of manholes / Septic tanks exceeding 1.5 Mtr complete all as specified and directed |
| 4 | M&L for pumping out sewage water / sludge from the blocked manhole/Septictank etcfor any depth for cleaning the existing sewage line through diesel pump set 7.5HP & disposal of sludge complete all as specified and directed |
| 5 | M&L cleaning of heavy blockage sewage line above 3.0 m depth by mechanically operated jetting / Suction machine with pressure water supply.Note :- The contractor shall remove the sewage / sludge and other foreign material from the site by mechanical equipment etc or by way or other any mean to outside MOD land in covered Vehicls ie Veh required for tpt of foul matters/gas etc and shall be disposed off complete all as specified and directed.The site shall be left by the contractor in neat and tidy condition before claiming his payment. |
| 6 | M & L Cleaning and testing of sewer line 150mm to 300mm internal dia depth upto 1.50m be removing blockage / chocking / obstruction of flow nad making free flow by rodding with steel rods and finally passing the rope through the line with jute cloth for cleaning the chocked/blocked sewer line complete all as specified and directed |
| 7 | All as per item No 1.05 above but depth of sewer line exceeding 1.5 Mtr complete all as specified and directed |
| 8 | Removing/cleaning blockage of WC, wash hand basin, floor/nahani trap, soil, waste & vent pipe, sewer line etc. of any height of bldg manually for day to day complaint with the help of vacuam pump or by rodding upto complete satisfaction of user\"s including opening and re-fixing of CI eye cover to bend and branch pieces(Tee bend) and finally cleaned with adequate quantity of water to make the job functional complete all as specified and directed |
| 9 | Demolition ofBrick work or stone/boulder masonry, build in cementmortar or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed |
| 10 | Demolition of cement concrete (unreinforced) of any description and in anyposition not otherwise specifically provided for complete all as specified and directed. |
| 11 | M & L for cement concrete 1:4:8,75 mm thick type D-1,(using 40mmgraded stone aggregates),andlaid in as floor subbase finished fair and even without using extra cement complete all as specified and as directed. |
| 12 | M & L for cement concrete 1:2:4,75mm thick type B-1,(using 20mm graded stone aggregates),andlaid in as floor finished fair and even without using extra cement complete all as specified and as directed. |
| 13 | Demolition of reinforcement cement concrete of any description and in anyposition not otherwise specifically provided for complete all as specified and directed. |
| 14 | Taking down cement or cement lime plaster of any descriptionon brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 15 | Excavation in trenches n.exc 1.50m wide and n.exc 1.5m deep forfoundation etc. for shafts, wells cess, pits manholes etcn exc 10 sqm on plan and n exc 1.5 m depth. in soft/loose soil and getting out complete all as specified and directed |
| 16 | Excavation in trenches n.exc 1.50m wideforfoundation etc. for shafts, wells cess pits, manholes etcn exc 10 sqm on plan andexc 1.5 mandn .exc 3.0mdepth. insoft/loose soil and getting out complete all as specified and directed |
| 17 | Returningand filling in of soft / loose in layyers n. exc 25CM thick each layer including spreading, leveling, watering and well ramming complete all as specified and directed |
| 18 | Removal of excavated material such as soils to a lead n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed |
| 19 | M&L for screed bed or bedding layer of mortar 20mm thick in CM 1:6for laying floor finishes complete all as specified and directed. |
| 20 | M&L for Chequered cement concrete tiles with grey cement and pigment of size 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors complete all as specified and directed |
| 21 | Demolition and breaking up drain pipes (SGSW)/RCC pipes set in CM including concretebed haunchingof any description for all as specified and directed for following :- |
| 22 | 150mm internal dia of pipes |
| 23 | 200mm internal dia of pipes |
| 24 | M&L for cement concrete (1:4:8) type D2bedding to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for :- |
| 25 | 150mm internal dia of pipes |
| 26 | 200mm internal dia of pipes |
| 27 | M&L for RCC ClassNP -2pipe laid in trenches, jointed as specified and as directed by Engineer-in-Chargefor:- |
| 28 | 150mm internal dia of pipes |
| 29 | 200mm internal dia of pipes |
| 30 | M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 31 | M&L Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment, set, jointed complete all as specified and directed |
| 32 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering cutting out existing benchingand forming branch channel in PCC (1:2:4) type B-1, smooth finished complete all as specified and directed |
| 33 | 150mm internal dia of pipes |
| 34 | 200mm internal dia of pipes |
| 35 | M&L for cement concrete 1:4:8 type D2 (40mm graded aggregate) in foundations etc filling & mass concrete complete all as specified and directed |
| 36 | M&L for brick work with sub class \"B\" bricks built in CM (1:4) straight orcurved on plan & exc 6 m mean radius with old size bricks complete all as specified and directed |
| 37 | M&L for cement concrete (1:3:6) type C1 using 20mm graded aggregate in manholes channles & drains and and all as specified and directed. |
| 38 | M&L for cement concrete 1:2:4 type B1 (20mm graded aggregate) as in coping,benching, kerb etc. rounded or chamfered on edges including necessary form work all as specified and directed. |
| 39 | M & L for rendering 15mm thick in cement mortar (1:4) on any face of brick work or concrete surafaces and finished the surface even and smooth with using extra cement complete all specified and directed. |
| 40 | M&L for providing precast cement concrete (1:2:4) type B-1 (20mm graded aggregate) as in manhole covers / slab set in cement mortar (1:4) all as specified and directed |
| 41 | M&L TMT bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia. or securing with clips complete all as specified and directed. |
| 42 | Taking down waste / soil pipes any size any pattern inludings cleaning or refixing or removal to store complete all as specified and directed |
| 43 | S&F PVC(SWR) 110mm dia soil / waste and rainwater drainage pipes (5 kgf / sqcm) single socketed with bends in any length with rubber ring joint laid in floor or fixed on wall incl branch piece, bend, socket etc complete all as specified and directed |
| 44 | S&F PVC(SWR) 75 mm dia soil waste and rainwater drainage pipes (5 kgf / sqcm) single socketed with bends in any length withrubber ring joint laid in floor or fixed on wallincl branch piece, bend, socket etc complete all as specified and directed |
| 45 | M & L PVC (SWR) floor trap, plain with grating including jointing with solvent cement of dia of outlet 75mm complete all as specified and directed |
| 46 | M & L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed |