| 1 | M&L in replacement for point wiring with 1.5 sqmmFRLSH, PVC insulated stranded copper conductor single core including non metalic PVC conduit medium grade (MMS ISI) of size not less than 20 mm dia(or as site requirement) concealed in wall/over ceiling, pressed steel concealed terminal boxes of required size and with top cover 3 mm thick of plastic laminated sheet of reqd colour, painting terminal boxes inside and out side with one coat red oxide primer complete with all accessories and all as specified including 1.5 sqmm FRLSH PVC insulated sheathed multistranded copper earth conductor to common earth and connected to earth dollyfor light / fan/ bell point controlled by one switch.Note:- (i) Cost of PVC conduit, steel terminal boxes, plastic laminated sheet cover etc; are deemed to be included in the quoted rate.(ii) M&L for cutting chases on walls / ceilingand making good disturbed surfaces including finishing with cement mortar (1:3) etc; are deemed to be included in the quoted rate. |
| 2 | All as per item 1.0 above but for 3 pin 5 Amps switch socket combination on independent board with 1.5 sq mm copper cable complete all as specified and directed. |
| 3 | All as per item 1.0 above but for 3 pin 16 Amps switch socket combination on independent board with 2.5 sq mm copper cable complete all as specified and directed. |
| 4 | All as per item 1.0 above but for 5 Amps socket point on the same board controlled by one switch complete all as specified and directed. |
| 5 | All as per item 1.0 above but for one light point controlled by two, two way switch with 1.5 sq mm copper conductor cable complete all as specified and directed. |
| 6 | M&L in replacement for point wiringwith 1.5 Sqmm multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including PVC casing caping of 25/32 mm wide, with double locking type, includingall accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, PVC terminal box and PVC board making good disturbed surface to match with the existing surface for one light /fan/bell point controlled by oneswitch complete all as directed by Engineer-In-charge. |
| 7 | All as per item 6.0 above but for One 3 pin socket outlet 5 Amps on same board complete all as specified and as directed. |
| 8 | All as per item 6.0 above but for One 3 pin socket outlet 5 Amps on indpendent board complete all as specified and as directed. |
| 9 | All as per item No.6.0 above but with 2.5 sqmm single core multistranded copper conductor FRLSH cable for 3/5 pin 15 Amp socket outlet on independent board complete all as specifided and directed |
| 10 | All as per item 6.0 above but for one light point controlled by two, two way switch with 1.5 sq mm copper conductor cable complete all as specified and directed. |
| 11 | S&F in replacement of switch piano (flush button type) single pole, one way, 5 Amps complete all as specified and directed. |
| 12 | S&F in replacement of switch socket combination 2 in one, 5 pin , 5/6 Amps, 240 Volts flush type,complete all as specified and directed. |
| 13 | S&F in replacement of switch socket combination 2 in One , 5/6 pin, 5/6/16 Amps flush type complete all as specified and directed. |
| 14 | S&F in replacement of socket out let, 5 pin 5 Amps flush typecomplete all as specified and directed. |
| 15 | S&F in replacement of switch flush type, 5 Amps, SP, two way complete all as specified and directed. |
| 16 | S&F in replacement of switch bell push flush type 5 Amps complete all as specified and directed. |
| 17 | S&F in replacement of call bell, Ding dong type, AC 230 Volts single pole complete all as specified and directed. |
| 18 | S&F in replacement of ceiling rose polycarbonate typethree terminals complete all as specified and directed. |
| 19 | S&F in replacement of step type electronic fan regulator 120 wattsingle pole 240 Volts complete all as specified and directed. |
| 20 | S&Fin replacement of Lamp holder PVC/Polycarbonate type with cord grip cap suitable for pendent fitting complete all as specified and directed |
| 21 | S&F in replacement of LED bulb of 10W with Lumen output 950 lm and Colour Temp 6500K B22 type fitted suitable for PVC /Poly Carbonate type complete all as specfied and directed. |
| 22 | S&F in replacement of LED Tube light luminaires, 20-22 watts, lumen output not lessthan 2000 (4 feet), made of anodised extruded aluminium housng, with high transmissivity diffuser, high lumen output, with suitable integrated electronic driver, and operated in single phase, 230 volts, 50HZ, all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable offrom connector and ceiling rose, complete all as specified and directed. Make :- Philips model SmartBright or equivalent in Wipro / Crompton |
| 23 | S&F in replacement of mirror light batten type 10/11 W 230V AC, 50Hz, Pf >0.98, THD <10% on wall complete all as specified and directed by Engineer in charge. Make :- Philips model Lineaor equivalent in Wipro / Crompton |
| 24 | S&F in replacement of LED bulk head wall light fixture 6 Watt , pressure die cast housing , IP 66 protection and IK 09 impact resistance suitable for surface and wall mountingcomplete all as specified and as directed. Make Philips(Cat No:- WT202W LED6S CW PSU S2 PC) or equivalent in Wipro / Crompton. |
| 25 | Taking down carefully water heater storage type of any capacity from its position for repair/ overhauling by disconnecting complete electric/water supply connections, taking out geyser assembly repairing re-assembling the geyser and refixing the same by connecting electric / water supply connections and testing complete all as specified and directed. Note: (spares will be measured and paid separately) |
| 26 | Supply and fixing in replacement of decorative wall light fixture metalic body single head wall light suitable for 20 watt maximun wattagecomplete all as specified and as directed. Make Philips(Model No - Grace wall light ) or equivalent in Wipro / Crompton. |
| 27 | S&F in replacement of LED recess mounted CW/WW light(2\"x2\" size flat panel) luminaire which provide soft light and glare free symmertical illumination suitable for armstrong/grid ceiling of 36Watt,(Lumen output not lessthan 3600K) complete all as specified and directed.Make Philips or equivalent in Wipro/Crompton. |
| 28 | S&F in replacement of Recess/ceiling mounted round glow type LED light 7 Watt down light aluminum die cast housingwhite/warm, dust free and zero maintainence complete all as specified and as directed by Engr in charge.Make Philips(Cat No:- DN091B LED6S - 6500 PSU WH) or equivalent in Wipro / Crompton.. |
| 29 | S&F in replacement of ultra bright LED PLL with high efficacy 18 W operated in single phase, 230 volts, 50HZ, suited for installation in existing 2G11 lamp holders complete all as specified and directed. |
| 30 | S&F in replacement of new generation energy saving and environmental friendly long life 25 W LED wall/building security light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top Opening seperate driver compartment with IP66 protection and impact resistance of IK07including necessary brackets (made out of suitable bore GI pipe light grade appx 0.6 meter long bend to shape) nuts, bolts, etc fixed on walls with MS clamp complete all as specified and directed . Make:- Philips/ Wipro / Crompton. |
| 31 | S&F in replacement of new generation energy saving and environmental friendly long life 35W LED wall street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top Opening seperate driver compartment with IP66 protection and impact resistance of IK07complete all as specified and directed. Make:- Philips of Model -SmartBright Street or equivalent in Wipro / Crompton. |
| 32 | Taking down ceiling fan any type/ size from hook and dismantling cable and blades and bring in to contractor store for repair and hanging ceiling fan in position after repair, greasing etc. with existing flexible copper cable complete all as directed. (rewinding of fan, painting and spare parts required shall be deemed to be included in the quoted rate) |
| 33 | Taking down exhaust fan any type/ size from wall and dismantling sealing cable and dismantling blades and bring in to contractor store for repair and fixing exhaust fan in position after repair, greasing etc. with existing flexible copper cable complete all as directed. (rewinding of fan, painting and spare parts required shall be measured and paid separately) |
| 34 | M&L for rewinding of ceilingfan 1200/1400 mm sweep after dismantlingand taking out the burnt winding coils and rewinding with super enamelled copper winding wire of suitable size and gauge including insulation, Varnishing, drying etc complete and refixing the same after rewinding and testing complete all as specified and directed. |
| 35 | M&L for rewinding of exhaustfan 280 to 450 mm sweep after dismantlingand taking out the burnt winding coils and rewinding with super enamelled copper winding wire of suitable size and gauge including insulation, Varnishing, drying etc complete and refixing the same after rewinding and testing complete all as specified and directed. |
| 36 | S&F in replacement of brass bush for ceiling fan / exhaust fan as existing size complete all as specified and directed. |
| 37 | S&F in replacement of bearing suitable for ceiling fan 1200 mm to 1400 mm /exhaust fan of bearing No- 6201/6202 complete all as specified and directed. |
| 38 | S&F in replacement of capacitor 2.5 MFD for ceiling fan. complete all as specified and directed. |
| 39 | Supply and fixing in replacement of capacitor 3.15 MFD for ceiling fan complete all as specified and directed. |
| 40 | Supply and fixing in replacement of rubber real with bolts, nuts and clamps of suitable for ceiling fan complete all as specified and directed. |
| 41 | Supply and fixing in replacement of PCB Circuitfor BLDC ceiling fan suitable ofmake Orient/Crompton/Havells or on site complete all as specified and directed. |
| 42 | Supply and fixing in replacement of PVC insulated flexible copper cable 3 core of size 23/0.0076 complete all as specified and directed. |
| 43 | S&F in replacement ofold u/s element and fixing of new heating element of capacity 1.5/2 KW of anytype (as per sample) complete all as specified and directed. Make: Bajaj/CG/USHA/JAGUAR/as per sample. |
| 44 | Supply and fixing in replacement old u/s thermostate for geyser and fixing of new thermostate adjustable between 30 degree to90 degree celcius of any size /type as per existing (ISI marked) complete all as specified and directed. |
| 45 | S&F in replacement of of insulation tape 25mm 18mtr roll suitable for 1100V all complete as specified and directed. |
| 46 | Supply and fixing in replacement of PVC connection pipe heavy duty 450mm long with 2 nuts brass at both ends suitable for hot water for GI pipe 15 mm dia complete all as specified and directed. |
| 47 | S&F in replacement of MS anchor fastener heavy duty 12mm dia 10 cm long complete all as specified and directed. |
| 48 | S&F in replacement of plug top, AC 230 Volts, 6 Amps complete all as specified and directed. |
| 49 | S&F in replacement of plug top, AC 230 Volts, 16 Amps complete all as specified and directed. |
| 50 | Supply and fixing in replacement of hylam sheet cover 3 mm thick for fixing switches,sockets, regulators etcof size 10 x 12 (Inches) on existing metal box complete all as specified and directed. |
| 51 | S&F in replacement of PVC conduit medium grade (MMS) with fittings, ISI marked, 25 mm size complete all as specified and directed. |
| 52 | S&F in replacement oft PVC casing & capping medium grade with fittings, ISI marked, 25 mm size complete all as specified and directed. |
| 53 | S&F in replacement of PVC switch boards, closed recessed suitable for surfaces, sizes 4 X 4 (Inches) complete all as specified and as directed. |
| 54 | S&F in replacement of PVC switch boards, closed recessed suitable for surfaces, sizes 4 X 7 (Inches) complete all as specified and as directed. |
| 55 | S&F in replacement of PVC switch boards, closed recessed suitable for surfaces, sizes 8 X 6 (Inches) complete all as specified and as directed. |
| 56 | S&F in replacement of PVC switch boards, closed recessed suitable for surfaces, sizes 8 X 10 (Inches) complete all as specified and as directed. |
| 57 | Supply and fixing in replacementold u/s indicator lamp and fixing of new indicator lamp of suitable capacity including its electrical connection complete all as specified and directed. |
| 58 | Supply in replacement of PVCinsulated copper conductor Cable, FRLSH, single core, 1100 Volts,2.5 Sq mm with colour coding complete all as specified and directed. |
| 59 | Supply and fixing in replacement of PVCinsulated copper conductor Cable, FRLSH, single core, 1100 Volts,6.0 Sq mm with colour coding complete all as specified and directed. |
| 60 | Supply and draw submain wiring with two single core 6 sq mm FRLSH PVC insulated copper cable 1100 volts grade multi stranded, sheathed conductor in concealed PVC conduitincluding 6 sq mm multi-strand FRLSHPVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface including taking down existing sheet complete all as specified and directed.Note:- Cost of PVC conduit, cutting chases on walls and making good disturbed wall surfaces including finishing with cement mortar (1:4) matching with the existing shade / tint are deemed to be included in the rates quoted. |
| 61 | All as per item no 60above but on surface PVC casing caping medium grade of 20-25 mm wide, with double locking type, includingall accessoriesincluding taking down existing sheet complete all as specified and directed. |
| 62 | Supply and draw submain wiring with two single core 4 sq mm FRLSH PVC insulated copper cable 1100 volts grade multi stranded, sheathed conductor on wall surface PVC casing caping medium grade of 20-25 mm wide, with double locking typeincluding 4 sq mm multi-strand FRLSHPVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface including taking down existing sheet complete all as specified and directed.Note:- Cost of PVC casing caping onwalls and making good disturbed wall surfaces matching with the existing shade / tint are deemed to be included in the rates quoted. |
| 63 | Supply and fixing in replacement of single pole and neutral enclouser with atwo pin and earth plug and socket complete with one pole MCB 20 Amps complete all as spd and directed. |
| 64 | Supply and fixing in replacement of sheet metal enclosuredouble door for DBs SPN 4 way 240 V completedouble door, flush mounted all as specified and as directed |
| 65 | Supply and fixing in replacement of sheet metal enclosure double doorfor MCB DBs SPN 8 way 240 V amps rated bus bar SPN, complete flush mounted all as specified and as directed. |
| 66 | Supply and fixing in replacement of sheet metal enclosure double doorfor MCB DBs SPN 12 way 240 V, complete flush mounted all as specified and as directed. |
| 67 | Supply and fixing in replacement of sheet metal enclosure double door for MCB DBs VTPN 04 way 415 V, suitable for 63/100 Amp MCCB as incomer complete flush mounted all as specified and as directed. |
| 68 | Supply and fixing in replacement ofMCB single pole (SP) 5 to 40 Amps,240 volts , C curve , AC , 50 Hz ,10 kA complete all as specified and directed. |
| 69 | Supply and fixing in replacement of MCB Single pole & neutral (SPN)32-40 Amps, 240 volts , C Curve, AC , 10 kA complete all as specified and directed. |
| 70 | S&F in replacement of PVC insulated copper conductor cable, FRLSH, single core, 1100 Volts,1.5 Sq mm with colour coding complete all as specified and directed. |
| 71 | S&F in replacement of PVCinsulated copper conductor Cable, FRLSH, single core, 1100 Volts,4.0 Sq mm with colour coding complete all as specified and directed. |
| 72 | S&F in replacement of MCB Four pole 63 Amps,415 volts , C curve , AC , 50 Hz ,10 kA complete all as specified and directed. |
| 73 | S&F in replacement of MCB Single pole & neutral (SPN)63 Amps, 240 volts , C Curve, AC , 10 kA complete all as specified and directed. |
| 74 | M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Metre below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 15 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as shown on electrical plate No. 3 of SSR part - I , including taking out old U/s complete alll as specified and directed . |
| 75 | S&F in replacement of Modular switch1 way6/10 Amp,sp,1 module complete all as specified and directed |
| 76 | S&F in replacement of modular switch16A, 1 module single pole, one waycomplete all as specified and directed. |
| 77 | S&F in replacement of modular step type electronic fan regulator ,two module 120 watt single pole 240 Volts complete all as specified and directed. |
| 78 | S&F in replacement of Modular bell push 6A 2 module complete all as specified and directed. |
| 79 | S&F in replacement of of modular socket outlet 5 pin ,6 Amps,2 module, 240 Volts complete all as specified and directed. |
| 80 | S&F in replacement of Modular Socket 6 A /16 A-2/3 pincombined 2 module complete all as specified and directed. |
| 81 | S&F in replacement of metal flushbox 10/12 module complete all as specified and as directed. |
| 82 | S&F in replacement of metal flushbox 8 module complete all as specified and as directed. |
| 83 | S&F in replacement of metal flush box 6 module complete all as specified and as directed. |
| 84 | S&F in replacement of metal flush box 3 module complete all as specified and as directed. |
| 85 | S&F in replacement of white cover plate with frame 10/12 module complete all as specified and as directed. |
| 86 | S&F in replacement of modular white cover plate with frame, 8 modules complete all as specified and as directed. |
| 87 | S&F in replacement of modular white cover plate with frame, 6 modules complete all as specified and as directed. |
| 88 | S&F in replacement of modular white cover plate with frame, 3 modules complete all as specified and as directed. |