Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-06-2025 | REVISED BOQ | BOQ | 19-06-2025 |
| Sl. No. | Item Description |
| 1 | Taking down chowkats or frames with shutter (without taking off shutter from the frames) n. exc 1.50 Sqm each complete all as specified and directed. |
| 2 | Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc. 1.50 Sqm n.exc 4 Sqm each complete all as specified and directed. |
| 3 | Taking down shutters of any descriptionexc. 1 Sqmbut n. exc. 2.0 Sqm each complete all as specified and directed. |
| 4 | Resecuring or easing & adjusting of shutters without taking down of shutters of any description not exc 2.0 Sqm each complete all as specified and directed. |
| 5 | S&F factory madesolid PVC door frame of size 50 mmx47 mm made out of 5mm thick wood grain printed PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with printed sheet reinforced MS square tube supplying & fixing in opening as per specification & drawing complete all as specified and directed. |
| 6 | S&FFactory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. supplying & fixing in frame at site as per specifications and drawing of page no 146 of SSR Part -II complete all as specifiedand directed. |
| 7 | S&F 2nd class hardwood plain solid, straight chowkat and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints all as specified inanddirected. |
| 8 | S&F 35 mm thick, 2nd class hardwood glazed and skeleton shutters, open rebated and prepare to receive gauge etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for secruing glass/gauge etc size of member of shutter as specified in SSR Part-I Section 8 Clause 8.20 (a), fitted to chowkats complete all as directed. |
| 9 | S&F 30 mm thick flush shutters solid core construction, with particle board core and ply wood face panels commercial type on both sides complete all as specified and as directed. |
| 10 | S&F35mm factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces.The size of rail and stile as per IS-1003 (Part - I) kiln seasoned and chemically pressure treated (35 mm thick with 2nd class HW rail and style) complete all as specified and directed. |
| 11 | S&F Stainless Steel butt hinges medium weightof size 100 mm complete all as specified and directed. |
| 12 | S&F MS butt hinges medium weight cold rolled of size 100 mm complete all as specified and as directed . |
| 13 | S&F in repair MS butt hinges medium weight cold rolled of size 100 mm complete all as specified and as directed . |
| 14 | S&F 250 mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixingclips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified directed, |
| 15 | S&F in repair250 mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixingclips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified directed, |
| 16 | S&F 150 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed. |
| 17 | S&F in repair 150 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed. |
| 18 | S&F Extruded aluminium alloy handles 150 mm long fabricated type anodised complete all as specified and directed. |
| 19 | S&F in repair Extruded aluminium alloy handles 150 mm long fabricated type anodised complete all as specified and directed. |
| 20 | Resecuring or easing & adjusting of shutters without taking down of shutters of any description exc 2.0 Sqm each complete all as specified and directed. |
| 21 | S&F in repair stainless steel door stopper with solid stem and rubber end fixed to doors all as specified and as directed including taking down old one. |
| 22 | Hacking out old broken glass (any thickness, size, quality or description)from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beadsarea exceeding 1.5 sqm complete all as specified and directed. |
| 23 | S&F sheet glass 4.8 mm thick ordinary quality and glazing with oil putty or glazing pins / spring clip in square, rectangle exc 0.5 sqm in each pan all as specified and as directed. |
| 24 | S&F in repair sheet glass 4.8 mm thick ordinary quality and glazing with oil putty or glazing pins / spring clip in square, rectangle exc 0.5 sqm in each pan all as specified and as directed. |
| 25 | S&Finstainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or stainless steel wire staple complete all as specified and directed |
| 26 | S&Fin repairs stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or stainless steel wire staple complete all as specified and directedincluding down old one. |
| 27 | Cutting holes in brick walls exc one brick but not exc two brick in mud mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required |
| 28 | S&F mild steel flat iron as in hold fast for door window frames or chowkat etc. cut to length or drilled hole and fixed with screw etc. complete all as directed grade of steelconforming to Fe-290 Gde-E-165 |
| 29 | S&F in repair 10 Ltr capacity PVC valveless syphonic action type flushing cistern low level white, with inlet, ball valve, float and handle including PVC flush pipe and brackets complete fixed in wall and floor to trap of WC as required and as directed including taking down old one |
| 30 | S&F in repair angular stop cock (chromium plated fancy type) 15 mm dia, cast copper alloy, screwed down, high pressure with crutch or butterfly handles, screwed both end for iron pipe or for unions complete all as specified and directed including taking down old one. |
| 31 | S&F in repair 15 mm bib tap, cast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed including taking down old one |
| 32 | S&F in repairtubular Towel rail chromium plated 20mm dia \"D\" type 600 mm long including brass screws and wooden / plastic cleats complete all as specified and directed including taking down old one. |
| 33 | S&F in repair corner/wall mounted sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed |
| 34 | M&L in rpair Vitreous China wash basin, white, flat back, size 550x400 mm includingsuitable size of CI brackets, brass chromuum plated waste fittings 32 mm dia with long screw shanks and fly nuts, chain and plug and porcelain stopper but including brackets complete all as specified and as directed including taking down old one. |
| 35 | S&F15mm dia pillar tap fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed including taking out old one. |
| 36 | S&F in repair 15mm dia pillar tap fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed including taking out old one. |
| 37 | S&F in repair chromium plated hand shower helth faucet ABB body with 8 mm dia. 1.00 m long CP flexiable pipe 15 mm borewith wall hook complete all as specified and directed including taking down old one. |
| 38 | S&F in repair chromium plated shower roses withswivel joints, 125mm size including fixing to steel pipe or union all as specified and directed |
| 39 | S&F in repair CP grating round of size 125mm dia with waste hole of approved design complete all as specified and as directed including taking out old one. |
| 40 | S&F in repair 32 mm dia low density poly ethylene pipes (LDPE) of pressure rating 6 kg/ cm2 as waste pipe of suitable length etc. completeall as specified and directed including taking down old pipe. |
| 41 | S&F in repairplastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. |
| 42 | S&F in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed. |
| 43 | S&F in repair stainless steel kitchen rack of size 750mm x 600mm x 300mm with 2 shelf, made out of 0.8 mm thick sheet fixed with suitable size cromium plated screws complete all as specified and directed including taking out old one. |
| 44 | S&F in repair 25mm dia stainless steel curtain rod with catrip type with hooks/brackets fixed on walls complete all as specified and directed including taking down old one. |
| 45 | M&L preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 46 | Demolition of brick work or stone/boulder masonry, built in lime mortar including all quoins, arches, pillars, ect but excluding dressed stonework and precast concrete articles. |
| 47 | M&L brickwork with subclass \"B\" bricks, straight or curved on plan exc 6m mean radius built in CM1:4 all as specified. |
| 48 | Taking down cement plaster on brick or concrete wall/ceiling etc including racking out joint hacking for key, scrubbing down with water etc. complete all as specified and as directed. |
| 49 | M&L 15mm thick plastering in cement mortaron brick/concrete wall surfacesin CM (1:6) and finishing the surfaces even and smooth without using extra cement complete all as specified & directed. |
| 50 | M&L rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilingsand finishing the surfaces even and smooth without using extra cement complete all as specified & directed. |
| 51 | M&L preparing new surfaces of walls and applying two coats of oil emulsion distemper over a coat of alkali resistant primer complete all as specified and directed. |
| 52 | M&L preparing new surfaces of ceiling and applying two coats of oil emulsion distemper over a coat of alkali resistant primer complete all as specified and directed. |
| 53 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 54 | M&L coloured printed glazed ceramic tilesin vertical surface 450 x 300 x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick plastering in cement mortar 1:4 brick or on concrete surfaces of wall and finishing the surfaces fair and even without using extra cement all as specified and directed as in backing of tiles complete all as specified and directed. |
| 55 | S&F Non skid ceramic coloured tiles 7 to 8mm th area of each tile exceeding 0.06sqm but not exc 0.11 sqm in floors etc. set and joined in neat cement slury and pointed in coloured cement to match including screed bed or bedding layer 15 mm thick in cement mortar 1:4 on floors for laying floor finish all as specified and as directed. Make : Johnson |
| 56 | M&L vitrified ceramic tiles 10mm thick (Square/rectangular) polished, area of each tiles not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or colured cement to matches light shed including screed bed or bedding layer 15 mm thick in cement mortar 1:4 on floors for laying floor finish complete all as specified and as directed. |
| 57 | M&L vitrified ceramic tiles 10mm thick (Square/rectangular) polished, area of each tiles not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or colured cement to matches light shed including rendering10 mm thick in cement mortar 1:4 on floors for laying floor finish complete all as specified and as directed. |
| 58 | M&L PCC 1:2:4 type B1(20 mm graded stone aggregate) as in bed block for embedding hold fast of doors, window frames or chowkats including necessary form work complete all as all as specified directed. |
| 59 | M&L for cleaning of aluminium windowsliding channels oiling to roller, tightning to lock, hinges, rubber gasket etcall as specified and as directed. |
| 60 | S&F in repair600 x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed including taking out old one. |
| 61 | Taking down aluminium window/ventilator with side hung,top hungor fixed type, sliding shutter of any description. |
| 62 | S&F anodised aluminiumdoor/ window / ventilator shutters, sliding typewith styles, rails, sash bar, sliding frame etc. all are made from anodised aluminium section all are made from anodised aluminium section weighting 0.55 kg / m including necessary jointing cleats, glazing clips, rubber packing, anodised, aluminium snap beadings, screws , aluminium handles, locking system etc complete all asspecified and directed. |
| 63 | Dismantling water tanks capacity exceeding 1000 ltr but not exceeding 2000 ltr and removing to store. |
| 64 | S&F Rotational moulded polyethylene water storage tanks capacity 1000 Ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I® complete all as specified and as directed |
| 65 | S&F Rotational moulded polyethylene water storage tanks capacity 2000 Ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I® complete all as specified and as directed |
| 66 | Dismantling ofstone slabs & tiles of any description or thickness in floor, aprons etc. complete all as specified and as directed. |
| 67 | M&L Granite (of any type) slab, 20 mm thick machine cutlaid over cement screed as in floor and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of the granite stone including cutting and polishing complete all as specified and directed (Note :- Screed bed shall be measured and paid separately under respective item) |
| 68 | S&F in repair anodised aluminium grill, having mesh size 100mmx100mm made out 4mm wide and 3mm thick aluminium section with MS hooks of 6mm round bars two numbers each side insert into the jambs/cill complete all as specified and directed including taking down old one. |
| 69 | M&L in repair for replacement of old spindle / washer including head for 15 mm dia brass wall mixer / basin mixercomplete all as specified and directed. |
| 70 | S&F in repair32 / 40 mm dia 1150 mm long PVC corrugated waste pipefixed to wallscompleteall as specified and as directed including taking down old one. |
| 71 | S&F in repair 15 mm dia PVC connections, 450 mm long with PTMT nuts of suitable size at two end complete all as specified and directed including taking out old one. |
| 72 | S&F in repairBall valves high pressure of PTMT with PTMT arm & highdensity plastic ball screwed for PVC Connection and fixed in cistern of 25mm dia pipe all as specified and as directed including taking down old one. |
| 73 | S&F in repair 25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends inpipe line and fixed including taking down old one. |
| 74 | S&F in repair 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends inpipe line and fixed including taking down old one. |
| 75 | S&F in repair vitreous China Wash down water closet pan (Pedestal Pattern), white fixed with brass screwswith necessary connection with water line and sewer line etc. complete including PVC seat cover for pedestal pan complete all as specified and directed including taking out old one. |
| 76 | S&F in repair vitreous china squatting pan, Orissa Pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) with CI trap of suitable size ( P or S type) including connection to trap and to flushing pipe, anti syphonic pipe etc completeincluding provision of lime concrete bedding & making good to floor complete all as specified and directed including taking out old one. |
| 77 | Supplying and laying in repair of 20mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified including taking down old pipe. |
| 78 | M&L CPVC Brass fittings like Brass elbow / Tee / Sockets / Reducing sockets / MBTA / FBTA / Union / Adaptor etc. suitable for fixing with steel pipe 20 mm dia CPVC pipe fixed in wall / floor complete all as specified and directed. |
| 79 | Taking up or down 15mm steetubing and connections including cleaning for re fixing or removal to store all as specified and directed. |
| 80 | M&L Tubes, \"medium grade\" 15mm galvanised,with all fitting and fixed complete to walls and ceilings or laid in floors all as specified and directed. |
| 81 | Taking up or down 20mm steetubing and connections including cleaning for re fixing or removal to storeall as specified and directed. |
| 82 | M&L Tubes, \"medium grade\"20mmgalvanised,with all fitting and fixed complete to walls and ceilings or laid in floors upto 4th storeyall as specified and directed. |
| 83 | M&L Tubes, \"medium grade\"20mmgalvanised,with all fitting and fixed complete to walls and ceilings or laid in floorsupto 5th to 8th storey all as specified and directed. |
| 84 | M&L Tubes, \"medium grade\"20mmgalvanised,with all fitting and fixed complete to walls and ceilings or laid in floors upto 9th to 12th storey all as specified and directed. |
| 85 | Taking up or down 25mm steetubing and connections including cleaning for re fixing or removal to store all as specified and directed. |
| 86 | M&L Tubes, \"medium grade\"25mmgalvanised,with all fitting and fixed complete to walls and ceilings or laid in floors upto 4th storeyall as specified and directed. |
| 87 | M&L Tubes, \"medium grade\"25mmgalvanised,with all fitting and fixed complete to walls and ceilings or laid in floorsupto 5th to 8th storey all as specified and directed. |
| 88 | M&L Tubes, \"medium grade\"25mmgalvanised,with all fitting and fixed complete to walls and ceilings or laid in floors upto 9th to 12th storey all as specified and directed. |
| 89 | S&Fin repair cast iron (sand cast) soil, waste and vent pipe 100 mm bore in any length, with or without ears, with cement joints, fixed with stack clamps out of 25x5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed including taking down old pipe upto 4th storey incl taking out old one |
| 90 | -ditto- but above item Nowork from 5 th to 8 th storied incl taking down old one. |
| 91 | -ditto- but above item Nowork from 9 th to 13 th storied incl taking down old one. |
| 92 | S&F in repair100 mm dia CI branch piece double, (equal or unequal) ordinary orinverted spigot or socketed type with oval access doors all as specified and directed including taking down old one. |
| 93 | S&F in repair 100 mm dia CI branch piece single, (equal or unequal) ordinary orinverted spigot or socketed type with oval access doors all as specified and directed including taking down old one. |
| 94 | S&F inrepair cast iron bends 100mm bore of pipe (any radius )with ducks foot or heel rest all as specified. |
| 95 | S&F in repair Cast iron floor trap 100 mm, setting and jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed including taking out old one. |
| 96 | S&F inrepair 100mm diameter of outletcast iron Nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) all as specified. |
| 97 | Dismantling boarding, anydescription, fixed in any position with nails |
| 98 | M&L for veneered decorative plywood, grade 1, 12mm thick (with BWR resin) with decorative faces veneers on one faces, fixed with screws to timber frame work |
| 99 | S&F110mm dia pipe for PVC (SWR) pipes single socketed/double socketed in any length with rubber ring joints, laid in trenches or in floor all as specified including taking down old pipe upto 4th storey incl taking out old one |
| 100 | S&F110mm dia pipe for PVC (SWR) pipes single socketed/double socketed in any length with rubber ring joints, laid in trenches or in floor all as specified including taking down old pipe upto 5 th to 8 th storied incl l taking out old one |
| 101 | S&F110mm dia pipe for PVC (SWR) pipes single socketed/double socketed in any length with rubber ring joints, laid in trenches or in floor all as specified including taking down old pipe upto 9 th to 12 th storied incl l taking out old one |
| 102 | S&F 110mm dia for PVC (SWR) bends any radius |
| 103 | S&F 110mm dia for PVC (SWR) branch piece single (single Y) equal or unequal |
| 104 | Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, (including unscrewing from boards/out-let boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc.), removing materials off the site of work and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 105 | Material and labour for (concelaed Type) point wiring including necessary chase cutting of wall for one light/fan/call bell point with 1.5 sqmmPVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts gradecontrolled by one way switchincluding 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC conduit and making good the distrubed surfaces as per the existing complete all as specified and as directed.Note:A. Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.B. The Rate of point wiring includes the following :-(i)Copper wire(ii)PVC Conduit with accessoreis(iii) Chase cutting |
| 106 | All as per item No 2 above but for one light point controlled by two 2 -way switches complete including taking down old unserviceable one all as specified and directed. |
| 107 | All as per item No 2 above but for one three pin socket outlet on same board all complete including taking down old unserviceable one all as specified and directed. |
| 108 | All as per item No 2 above but for one three pin socket out let 5 amps on independent board complete including taking down old unserviceable one all as specified and directed. |
| 109 | M & L for concealed type point wiring with 2.5 sqmm (Nominal Area) FRLSPVC insulated un sheathed multi stranded copper conductor, 1100 Volts grade, in and including PVC conduit medium duty (ISI marked)not less than 20 mm diawith accessories such as bends, cross, elbow, tees etc. of suitable size including continuous earth wire FRLSPVC insulated unsheathed 2.5 Sq mm(nominal area) copper multi-stranded conductor, 1100 Volts grade, connecting to common earth and earth dolly for 16 Amp socket complete all as specified and as directed. |
| 110 | All as per Item No 6 but point wiring of size 4.00 Sqmm copper conductor cable |
| 111 | Material and labour for point wiring including necessary PVC Casing and caping of size not less than 25 mm of wall for one light/fan/call bell point with 1.5 sqmmPVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts gradecontrolled by one way switchincluding 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC casing and making good the distrubed surfaces as per the existing complete all as specified and as directed.Note:A. Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.B. The Rate of point wiring includes the following :-(i)Copper wire (ii)PVC Casing and caping with accessoreis (iii) Chase cutting |
| 112 | All as per item No 8 above but for one light point controlled by two 2 -way switches complete including taking down old unserviceable one all as specified and directed. |
| 113 | All as per item No 8 above but for one three pin socket outlet on same board all complete including taking down old unserviceable one all as specified and directed. |
| 114 | All as per item No 8 above but for one three pin socket out let 5 amps on independent board complete including taking down old unserviceable one all as specified and directed. |
| 115 | M & L for Casing and caping point wiring with 2.5 sqmm (Nominal Area) FRLSPVC insulated un sheathed multi stranded copper conductor, 1100 Volts grade, in and including PVC conduit medium duty (ISI marked)not less than 20 mm diawith accessories such as bends, cross, elbow, tees etc. of suitable size including continuous earth wire FRLSPVC insulated unsheathed 2.5 Sq mm(nominal area) copper multi-stranded conductor, 1100 Volts grade, connecting to common earth and earth dolly for 16 Amp socket complete all as specified and as directed. |
| 116 | All as per Item No 12 but point wiring of size 4.00 Sqmm copper conductor cable |
| 117 | S&F Switch piano flush type single pole one way 5A SP 230 Volts complete including taking down unserviceable one all as specified and as directed. |
| 118 | S&F Switch piano5A SP 230 Volts 2 way complete including taking down unserviceable one all as specified and as directed. |
| 119 | S&F Switch piano15A SP 230 Volts one way complete including taking down unserviceable one all as specified and as directed. |
| 120 | S&F Ceiling rose PVC surface type 3 terminalscomplete including taking down unserviceable one all as specified and as directed. |
| 121 | S&F Fan Regulator electronicstepped type, 230 voltscomplete including taking down unserviceable one all as specified and as directed. |
| 122 | S&F Lamp holder PVC/Polycarbonate type complete including taking down unserviceable one all as specified and as directed. |
| 123 | S&F Call bell, multi music type and connection complete including taking down unserviceable one all as specified and as directed. |
| 124 | S&F Bell push switch piano flush type 5 Amp SP one way completeincluding taking down unserviceable oneall as specified and as directed. |
| 125 | S & F 6 Amps one way single pole switch modular type completeincluding taking down unserviceable oneall as specified and as directed. |
| 126 | S & F 16 Amps one way single pole switch modular type completeincluding taking down unserviceable oneall as specified and as directed. |
| 127 | S & F bell push for calling bell 5 amps flush modular type completeincluding taking down unserviceable oneall as specified and as directed. |
| 128 | S & F fan regulator step type electronic flush 2 modular type completeincluding taking down unserviceable oneall as specified and as directed. |
| 129 | S & F modular metal box 1 way complete including taking down unserviceable one all as specified and as directed. |
| 130 | S & F modular metal box 2 way complete including taking down unserviceable one all as specified and as directed. |
| 131 | S & F modular metal box 3 way completeincluding taking down unserviceable one all as specified and as directed. |
| 132 | S & F modular metal box 4 way complete including taking down unserviceable one all as specified and as directed. |
| 133 | S & F modular metal box 6 way complete including taking down unserviceable one all as specified and as directed. |
| 134 | S & F modular metal box 8 way complete including taking down unserviceable one all as specified and as directed. |
| 135 | S & F modular white cover plate with frame 1 way complete including taking down unserviceable one all as specified and as directed. |
| 136 | S & F modular white cover plate with frame 2 way complete including taking down unserviceable oneall as specified and as directed. |
| 137 | S & F modular white cover plate with frame 3 way complete including taking down unserviceable oneall as specified and as directed. |
| 138 | S & F modular white cover plate with frame 4 way completeincluding taking down unserviceable oneall as specified and as directed. |
| 139 | S & F modular white cover plate with frame 6 way completeincluding taking down unserviceable oneall as specified and as directed. |
| 140 | S & F modular white cover plate with frame 8 way complete including taking down unserviceable one all as specified and as directed. |
| 141 | S&F Switch Socket combination outlet 2 in 1 3/5 pin 5 and 15 Amps flush type complete including taking down unserviceable one all as specified and as directed. |
| 142 | S&F Switch Socket combination outlet 2 in 1 3 pin 5 Amps Flush type completeincluding taking down unserviceable one all as specified and as directed. |
| 143 | S&F Socket outlet 2 in 1,2/3 pin, 5 Amps Flush type completeincluding taking down unserviceable oneall as specified and as directed. |
| 144 | S&F Socket outlet 2 in 1,5/6 pin, 15 Amps Flush type completeincluding taking down unserviceable oneall as specified and as directed. |
| 145 | S & F socket outlet 6A - 2/3 pin combined 2 module, modular type completeincluding taking down unserviceable one all as specified and as directed. |
| 146 | S & F socket outlet 6A/16A - 2/3 pin combined 2 module, modular type completeincluding taking down unserviceable one all as specified and as directed. |
| 147 | S & fix LED Bulbtype 12 Watt in warm white/natural white including taking down old unserviceable/fused one complete all as specified and as directed. |
| 148 | M & L for 1 X 20 wattLED ceiling/wall mountedlighting fixture with Lamp Lumen not less than 100 lum/watt polycarbonate ,enviornmental friendly ,energy efficient fixed to wall/ ceilling & connecting upto ceiling rose with three core twisted flexible 1.5 sqmm PVC copper conductor cable with earthing including taking down complete all as specified and as directed. |
| 149 | M & L for 1 X 10 wattLED ceiling/wall mountedlighting fixture with Lamp Lumen not less than 100 lum/watt polycarbonate ,enviornmental friendly ,energy efficient fixed to wall/ ceilling & connecting upto ceiling rose with three core twisted flexible 1.5 sqmm PVC copper conductor cable with earthing complete including taking down all as specified and as directed. |
| 150 | S & F LED surface mounted, glare free uniform illumination with longer life and less maintenance, 18 W with minimum lumen capacity 100 Lum/W complete all including taking down old one all as specified and as directed. |
| 151 | S & F LED recessed/surface mounted full open 2 ft x 2 ft tile, glare free uniform illumination with longer life and less maintenance, 36/24 W with minimum lumen capacity 100 Lum/W complete including taking down old one all as specified and as directed. |
| 152 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. |
| 153 | S & F LED round/square recessed/surface mounted full open, glare free uniform illumination with longer life and less maintenance, 15 W in warm white/cool white complete including taking down old one all as specified and as directed. |
| 154 | S&F PCB of BLDC ceiling fan of any make/model/sweep/wattage all as specified and as directed. |
| 155 | Supply only remote of BLDC ceiling fan of any make/model/sweep/wattage all as specified and as directed. |
| 156 | Supply and fixing ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. Note : Unservicable fan deposited to MES store. |
| 157 | S & F Wall mounted FanHi speed 400 mm sweep, including all fitting arrangement and all necessary fittings complete all as specified and as directed.Note : Unservicable fan deposited to MES store. |
| 158 | M&L for repair of wall mounting fan of any make/model/sweep including removal of existing burnt winding carefully from slots, cleaning the slots throughly with suitable cleaning agent, applying slot insulation and rewinding with super enamelled copper conductor of same gauge/same number of turns as that of existing and connecting the coil suitable to operate on 230 V, single phase, AC supply, permanent capacitor type, tying the winding and applying air drying the winding throughly and all as specified and directed. |
| 159 | Supply & fix air circulator of size 1200 mm complete and accessories 230 V,. BEE 5 star rated complete all as specified and as directed. Note : Unservicable fan deposited to MES store. |
| 160 | Taking down ceiling fan of any make/model and sweep for ovehauling/servicing, cleaning and lubricating movable parts with suitable lubricating oil/grease and refixing at site and connection complete from ceiling rose to connector with new flexible cord of suitable size, testing after completion of the workall as specified and as directed.Note : The accessories such as bearing and capacitor will be measured and paid seperately under relevent item. |
| 161 | Supply and fix Capacitor 2.5 mfdsuitable for ceiling fan of any make/model and sweepall as specified and as directed . |
| 162 | Supply only Lower and Upper Ball bearing No 6201/6202/6203 suitable for ceiling fan of 1200 mm sweepall as specified and as directed . |
| 163 | M&L for rewinding of ceiling fan of any make/model/sweep including removal of existing burnt winding carefully from slots, cleaning the slots throughly with suitable cleaning agent, applying slot insulation and rewinding with super enamelled copper conductor of same gauge/same number of turns as that of existing and connecting the coil suitable to operate on 230 V, single phase, AC supply, permanent capacitor type, tying the winding and applying air drying the winding throughly and all as specified and directed. |
| 164 | M&L for painting to ceiling fan with one coat of synthetic enamel paint of approved quality and colour (spray painted) after preparing the surface throughly and refixing at site at same/different locationall as specified and as directed . |
| 165 | Taking down exhaust fan of any make/model and sweep for ovehauling/servicing, cleaning and lubricating movable parts with suitable lubricating oil/grease and refixing at site at same/different location and connection complete from ceiling rose to connector with new flexible chord of copper of suitable size, testing commissioning after completion of the work.Note : The accessories such as bearing and capacitor will be measured as supply only. |
| 166 | Supply and fix Capacitor 2.5 MFD 230 Volt suitable for exhaust fan of any make/model and sweepall as specified and as directed . |
| 167 | Supply only Ball bearing suitable for exhaust fan of any sweepall as specified and as directed . |
| 168 | M&L for rewinding of exhaustfan of 250/300mmincluding removal of existing burnt winding carefully from slots, cleaning the slots throughly with suitable cleaning agent, applying slot insulation and rewinding with suer enamelled copper conductor of same gauge/same number of turns as that of existing and connecting the coil suitable to operate on 230 V, single phase, AC supply, permanent capacitor type, tying the winding and applying air drying the winding throughly and all as specified and directed. |
| 169 | M&L for painting to exhaust fancomplete with one coat of synthetic enamel paint of approved quality and colour (spray painted) after preparing the surface throughly and refixing at site at same/different locationall as specified and as directed . |
| 170 | Supply and fix Louver for exhaust fan of existing typeincluding taking down old one all as specified and as directed. |
| 171 | Supply and fix Air Ventilating fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm including taking down complete all as specified and as directed.Note:(i)The rate of materials used for scafolding works shall be deemed to be included in the quoted rate, materials also be arranged by the contractor and also shall be taken back safely by the workers employed by the contractor at his own risk.(ii) Unservicable fan deposited to MES store |
| 172 | Supply and fix Air Ventilating fan, steel body (Industrial type) AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers including taking down complete all as specified and as directed.Note :(i)The rate of materials used for scafolding works shall be deemed to be included in the quoted rate, materials also be arranged by the contractor and also shall be taken back safely by the workers employed by the contractor at his own risk.(ii) Unservicable fan deposited to MES store. |
| 173 | M & L for sub main wiring with two single core PVC insulated unsheathed , 1100 Volts grade, (FR-LS) copper cable 2 X 4 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface conduit medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade,cable 1 X 4 sqmm copperconductor and connected to common earth dolly complete including taking down old submain wiring as directed . Note :-(i) One run of PVC conduit, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit.(ii) Quoted rate is incluive of chase cutting, laying of conduit and making good the surface with proper plaster all as directed. |
| 174 | M & L for sub main wiring with two single core PVC insulated unsheathed , 1100 Volts grade, (FR-LS) copper cable 2 X 2.5 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface conduit medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade,cable 1 X 2.5 sqmm copperconductor and connected to common earth dolly completeincluding taking down old submain wiring as directed . Note :-(i) One run of PVC conduit, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit. (ii) Quoted rate is inclusive of chase cutting, laying of conduit and making good the surface with proper plaster all as directed. |
| 175 | M & L MCB FP \"B\" series 40-100 Amps including taking down complete all as specified and as directed. |
| 176 | M & L MCB FP \"B\" series 16-32 Amps including taking down complete all as specified and as directed. |
| 177 | M & L MCB DP \"C\" series 6-40 Amps including taking down complete all as specified and as directed. |
| 178 | M & L MCB SP \"C\" series 5-32 Amps including taking down complete all as specified and as directed. |
| 179 | Supply and fix sheet steel enclosure 4 way TPN DB with suitable size bus bar with provision for TPN MCBas incomer, double door type all as specified and as directed. |
| 180 | S & F sheet metal DB 12 way double door with suitable size rated bus bar single pole with neutral including taking down complete all as specified and as directed. |
| 181 | S & F sheet metal DB 8 way double door with suitable size rated bus bar Single pole with neutral including taking down complete all as specified and as directed. |
| 182 | S & F sheet metal DB 4 way double door with suitable sizerated bus bar Single pole with neutral including taking down complete all as specified and as directed. |
| 183 | Taking down water heater (geyser) 25 ltrs capacity for servicing and scraping, cleaning including brazing of inner vessel of the geyser at leakage point to made it leak proof including testing pressure and assembling of all component refixing complete including supply and fixing of minor spare parts all as specified and as directed. |
| 184 | S & F heating element 1000-2000 Watt ISI marked for gyser as per existing size with all connecting accessories including taking down complete all as specified and as directed. |
| 185 | S&F for thermostat switch of geyser 230V, 30 degree to 90 degree centigrade temp range to be set at 70 degree to 50 degree centigrade suitable for water heater complete including taking down old unserviceable all as specified and as directed |
| 186 | S&F SS connecting pipe set for geyser of best quality of suitable size and length including taking down old one complete all as specified and directed. |
| 187 | S& F Air release valve 15 mm dia for geyser including taking down all as specified and directed. |
| 188 | S&F for PVC insulated unsheathed three core flexible copper cable of size 2.5 sq mm complete including taking down old unserviceable all as specified and as directed |
| 189 | Supply and fix 15 Amp plug top with indicator for geyser including taking down old oneall as specified and as directed. |
| 190 | S&F copper/SS inner shell of electric geyser of cap 25 ltr 2 mm thick sheetincluding taking down old unserviceable all as specified and as directed |
| 191 | Supply and fix electric water heater, storage type steel body with suitable size and quality inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. |
| 192 | Servicing of Split/window type AC unit of capacity 1.5/2.0 TR that includes cleaning of air filters, indoor un it grilss & filters through air blower, cleaning of indoor unit body by wiping out dust etc. with wet cloth, cleaning of blower and condensor fan, cleaning of evaporator & condenser coils, graseing/oiling of motors and all moving marts and checking various parts of AC for proper functioning.Note: (i) All major parts or spares as mentioned below will be measured separately. (ii) Charging of gas to be measured separately. (iii) Rate of all minor spares deemed included in the rate. |
| 193 | S & Charging R-134A / R-410A refrigerant gas complete all as specified and as directed. |
| 194 | Supply & fixing only Hermeatically sealed unit of compressor for AC of 1.5/2.0 TR capacity including charging gas R-134A/ R-410A complete including taking down all as specified and as directed. |
| 195 | S & F Electronic circuit board as existing type for 1.5 TR/2.0 TR capacity split type AC complete including taking down all as specified and as directed. |
| 196 | S & F display board as existing type for 1.5 TR / 2.0 TR capacity Split / window type AC complete including taking down all as specified and as directed. |
| 197 | S & F Capacitor combined type 50 MFD capacity for 1.5 TR / 2.0 TR split/window type AC complete including taking down all as specified and as directed. |
| 198 | S & F running capacitor for 1.5 TR/2.0 TR window/ split type AC as per existing type complete including taking down all as specified and as directed. |
| 199 | S & F starting capacitor for 1.5 TR/2.0 TR window/ split type AC as per existing type complete including taking down all as specified and as directed. |
| 200 | S & F Capilary tube copper 1.5 TR/2.0 TR window/ split type AC as per existing type complete including taking down all as specified and as directed. |
| 201 | S & F Blower fan motor for indoor unit 1.5 TR/2.0 TR window/ split type AC as per existing type including taking down complete all as specified and as directed. |
| 202 | S & F outer fan motor for outdoor unit 1.5 TR/2.0 TR window/ split type AC as per existing type including taking down complete all as specified and as directed. |
| 203 | S & F swing motor for indoor unit 1.5 TR/2.0 TR window/ split type AC as per existing type including taking down complete all as specified and as directed. |
| 204 | S & F 3 core copper cable 4.0sqmm for connection outer to inner unit of split type AC including taking down complete all as specified and as directed |
| 205 | S & F copper tube 3/8\" or5/8\" size thickness 0.7 mm for connection to outer to inner unit for 1.5 TR / 2.0 TR capacity split type AC including taking down complete all as specified and as directed. |
| 206 | S & F insulation cover/tape for thermally insulated copper tube for 1.5 TR / 2.0 TR capacity including taking down complete all as specified and directed |
| 207 | Supply & Fixing medium grade PVC Conduit for drain water of size 15 mm dia including taking down complete all as specified and as directed. |
| 208 | S & F Fan blade existing type for window / split type AC including taking down complete all as specified and as directed. |
| 209 | Supply only remote for spilit/window type AC as per site/ordered model complete all as specified and as directed by Engr-in-Charge. |
| 210 | Supply and fix condensor coil for spilit/window type AC as per site/ordered model complete all as specified and as directed by Engr-in-Charge. |
| 211 | M&L for shifting of existing AC unit any type/any capacity to any location within the area with testing including making good of disturbed surfaces all as specified and as directed.(Note: PVC conduit pipe, copper tube, insulation cover and flexible copper cable to be measured separately.) |
| 212 | S&F stand for outdoor AC unit made up of powder quoted MS angle including removal of old stand and making good the disturbed surafaces all as specified and as directed. |
| 213 | M&L for filter of existing of AC unit any type/any capacity to any location within th area with testing all as specified and as directed. |
| 214 | Repair/maintenance and fitment of existing water Cooler of existing capacity including repair/replacement of spares with proper cleaning of water storage space, cooling coil, supply and charging of refrigerent, maintenance of compressor etc for proper functioning complete all as specified and as directed. |
| 215 | Supply & fixing only Hermeatically sealed unit of compressor for Water cooler of 120 Ltr capacity including charging gas R-22 complete including taking down all as specified and as directed. |
| 216 | Supply and fixing single phase KWh meter with LCD display, 5-40A with box, including connection wire and grouting of nut, bolts, complete all as specified and directed. |
| 217 | M&L for power unit6 module flush type with starter, DP MCB & Plugtop with indicator including taking down complete all as specified and as directed. |
| 218 | S&F PVC Sign Board with details acrylic sandwich sheet board waterproof for display with 10 mm thickness and of suitable size complete all as specified and as directed.Note: Subject material to be provided by the department. |
| 219 | Supply and fix Surface PVC box of suitable suitable size for mounting of switches ,sockets ,regulators MCB\"s etc complete all as Specified and directed. |
| 220 | Supply and Lay PVC Conduit pipe 20 mm dia for laying of wires in case of emergency electric connections all as specified and directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail