| 1 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 2 | S&F rolled mild steel section Fe 410 -W (Gde- E- 250) quality \"B\" framed work as in doors or gates with frame/chowkat with hand made holdfast made from angle of other section with gusset plates, rails braces, flat etc. complete drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings with sliding door bolts etc. (excluding steel covering which shall be measured and paid separately under respective items in this Schedule) and hanging fastening and fixing at any level in high raised bldg complete all as specified and directed by Engineer-in-Charge. |
| 3 | S&F Steel work in tubular trusses / Framed work including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 |
| 4 | S&F Mild steel bolts. purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. Exc 30cm long Exc 12 n. exc 20mm diameter of neck all as specified |
| 5 | M&L preparation of new or previously untreatedsteel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 6 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 7 | M&L brick work with sub class \"B\" bricks straight or curved in plan exc 6 mtr mean radius built in CM (1:6) using old size bricks complete all as specified and as directed. |
| 8 | Taking down cement plaster on brick or concrete wall/ceiling etc including racking out joint hacking for key, scrubbing down with water etc. complete all as specified and as directed. |
| 9 | M&L for rendering 15 mm thick on brick or concrete surfaces in CM 1:4 finished surface even and smooth without using extra cement complete all as directed. |
| 10 | Material & Labour for applying two coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. all as specified and directedfor work upto 4 th storied. |
| 11 | Cleaning of RCC roof tank of capacity more than 25000 ltrs by taking down existing inlet and outlet pipes and cleaning, rubbing down and removing all scales and dirt, mud and any other foreign materials etc from inside complete incl writing letter on RCC tank as TANK CLEANED ON ____ (Dt, Month and year) complete all as specified and as directed. |
| 12 | Demolition of cement concrete is reinforced ( reinforcement cut as required to facilitate demolition ) in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work ® |
| 13 | S&F Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 14 | M&L for RCC nominal mix M-20 type -A1 1:1.5:3 (20mm crushed stone aggregate) as in slab for footpath , ramp etc. including necessary form work complete all as specified and as directed. |
| 15 | Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 16 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 17 | M&L for Cement concrete 100 mm thick Type C1 (1:3:6) 20 mm graded stone aggregate as in floor finish concrete surface even and rough finish to receive topping layer. |
| 18 | M&L screed bed or bedding layer 15 mm thick in cement mortar 1:6 on floors for laying floor finish complete all as specified and as directed. |
| 19 | M&L for 12mm thick heavy duty industrial floors tiling of approved size and colour with minimum flexural strength of 38N/MM all as specified. |
| 20 | M&L for Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed with grey cement and no pigment and pointed in neat cement slurry in floors all as specified and as directed incl taking down old one |
| 21 | Dismantling of 100mm dia in pipecast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches or wallif required |
| 22 | S&Fcast iron (sand cast) soil, waste and vent pipe 100 mm bore in any length, with or without ears, with cement joints, fixed with stack clamps out of 25x5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed including taking down old pipe upto 4th storey incl taking out old one |
| 23 | S&Fcast iron (sand cast) soil, waste and vent pipe 100 mm bore in any length, with or without ears, with cement joints, fixed with stack clamps out of 25x5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed including taking down old pipe upto 5th to 8th storey incl taking out old one |
| 24 | S&F cast iron (sand cast) soil, waste and vent pipe 100 mm bore in any length, with or without ears, with cement joints, fixed with stack clamps out of 25x5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed including taking down old pipe upto 9th to 13th storey incl taking out old one |
| 25 | S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof bore of pipe in 100mm all as specified. |
| 26 | S&F 100 mm dia CI branch piece double, (equal or unequal) ordinary orinverted spigot or socketed type with oval access doors all as specified and directed including taking down old one. |
| 27 | S&F 100 mm dia CI branch piece single, (equal or unequal) ordinary orinverted spigot or socketed type with oval access doors all as specified and directed including taking down old one. |
| 28 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out |
| 29 | Demolition and breaking up drain pipes Internal dia of pipe in150mmmm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar |
| 30 | M&L for 150 mm thick Concrete bed to drain pipes in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate including packing under and haunching against the sides of pipes after they are laid and tested for 200 mm bore pipe complete all as specified and as directed. |
| 31 | S&F for reinforced concrete pipes 150 mm bore, class NP2 laid and jointed complete with collars |
| 32 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etcincluding move to store or otherwise complete |
| 33 | M&L Granite (of any type) 20mm thick work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 34 | Cutting into existing manhole, 225 mm bore pipe, for connecting new drains making good to pipe and removing cutting out existing benching for and forming branch channel in cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregates, smooth finish and re-forming benching complete all as specified and as directed |
| 35 | Material and labour including tools and plant required for cleaning of manholes using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual scavengers and their Rehabilitation Rules, 2013 and removing blockage if any and removing night soil/ silted sludge/ waste material outside MD land unprohibited by any authority and following the statutory law/ guidelines complete all as specified and as directed. |
| 36 | M&L including tools and plant required for cleaning of blockage of wash basin, floor trap , nahani trap , gully trap (GT) , kitchen, bath etc. (carrying slage ) in any length upto the first manhole by any means (using chemical or any mechanical device) & flushing with water complete UPTO 4th FLOOR all as specified. |
| 37 | M&L including tools and plant required for cleaning of blockage of wash basin, floor trap , nahani trap , gully trap (GT) , kitchen, bath etc. (carrying sludge ) in any length upto the first manhole by any means (using chemical or any mechanical device) & flushing with water complete UPTO 5th TO 8th FLOOR all as specified. |
| 38 | M&L including tools and plant required for cleaning of blockage of wash basin, floor trap , nahani trap , gully trap (GT) , kitchen, bath etc. (carrying slage ) in any length upto the first manhole by any means (using chemical or any mechanical device) & flushing with water complete UPTO 5th TO 12th FLOOR all as specified. |
| 39 | M&L including tools and plant required for cleaning of the drain pipes upto 150mm dia by roading from manhole and well flushing with water after cleaning and removing all sludge , dirt and solid contents to a distance n exc 100m and burried in ground (min 30cm below ground level) including necessary excavation returning filling and spreading of bleaching powder complete all as specified. |
| 40 | Supply and fixed in repairs 600 mm x 450 mm x 75mm thick precast RCPC perforated drain cover slab of 2 MT load bearing capacity with embossing RCPC 2MTcomplete all as specified and as directed including taking down old unserviceable cover. |
| 41 | Scrapping worn out tarfelt and bituminous compound of water proofing treatment over RCC roof by using wire brush and blow lamps including dismantling cracked/broken PCC (if requiredsweeping, cleaning washing down to remove dust etc and removing rubbish debris etc n.exc 50 m from the site (s) complete all as specified & directed. |
| 42 | M & L 20mm thick (avg min thickness) plastering in cement mortar 1:3, finishing the plastered surfaces even and smooth over cleaned RCC roof. The plastered surface shall be cured properly for ten days by ponding of water over roof. |
| 43 | Supplying and applying high build elastomeric water proofing coating based on pure, hydrophobic polyurethene, cold applied of spray / brush applied, smartcare PU Aqua membrane with an elangation of 450% and tensile strength>1.5 Mpa as per ASTM D 2370, crack bridging ability upto 4mm, solid content of 60% the system includes final base preparation, epoxy primer application and applying Smart Care PU Aqua or approved equivalent in two coats with a consumption of 2 Kg per Sqm on a primed surface with Apcoflor HFP 130 Primer, etc, Complete as per manufacturer specification. |
| 44 | S&F PVC safety net in three Braided layers for covering the dubries / concrete stone from bldg including taking down complete all as specified and directed |