}

Supply & Installation Of Ill:1 Service And Lan Structuring Networking Setup For Connectivity Type Ill 10Mbps 1:1 At Jda Building Vikas Bhawan Jammu(5Th Time), jammu-Jammu And Kashmir

Department Of Housing And Urban Development has published Supply & Installation Of Ill:1 Service And Lan Structuring Networking Setup For Connectivity Type Ill 10Mbps 1:1 At Jda Building Vikas Bhawan Jammu(5Th Time). Submission Date for this Tender is 09-06-2025. LAN Tenders in jammu Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

49401599
Supply & Installation Of Ill:1 Service And Lan Structuring Networking Setup For Connectivity Type Ill 10Mbps 1:1 At Jda Building Vikas Bhawan Jammu(5Th Time)
Tender
Indian
Jammu And Kashmir
Jammu
09-06-2025

Tender Details

Supply & Installation of ILL:1 Service and LAN Structuring Networking Setup for Connectivity type ILL 10Mbps 1:1 at JDA Building Vikas Bhawan Jammu(5th Time)- 1 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as pre approved by Executive Engineer in charge. 2 Providing & fixing of Router (Nic Complaint) complete job. (Specifications as per Annexure C of this e-NIT) All as pre approved by Executive Engineer in charge. 3 Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required (Specifications as per Annexure C of this e-NIT). All as pre approved by Executive Engineer in charge. 4 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulationdisplacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications including modular/MS Boxes along with necessory connections as required. All as pre approved by Executive Engineer in charge. 5 Supply Installation Testing & Commissioning offollowing sizesEquipment Rack with provision for housing all control equipment with front & rear door, Blower for cooling, power Distribution Paneland proper locking arrangements. 6 12 U Rack 7 42 U Rack 8 Supply, installation, testing and commissioning of Patch Panel Cat 6 UTP Keystone type- 24 port - fully loaded with all accessories as required in complete respect as technical specification mentioned in compliance. Complete Job as per site requirment. 9 Supplying and fixing of following sizes of PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI Make). 10 25 mm 11 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP). All as per pre approved by Engineer in charge.Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 12 1 Mtr 13 3 Mtr 14 6 Mtr 15 Supply Installationtesting and commissioningof 5 KVA/ 4 KW True Online , DSP Controlled online UPS with1 phase AC input 50Hz and 1 phase AC outputwith60 minutesbackup on12V SMF batteriesBank withRack along with inter connecting battery cables and cable from UPS to Battery bank.The UPS should bewith IGBT Based Rectifier and Inverterand with LCD/LEDdisplay for monitoring of its statusalong withinbuilt Galvonic Isolation Transformer.UPS should have followingFeatures: UPSpower factor : Input PF should be0.99 AND output PF not less than 0.9 , Efficiency:up to 97% without Isolation ,Communication interface :RS232/USB portand optional SNMP compatibility for remote Monitoring, Audible Alarm : Mains Failure/Low battery / UPS Warning / Overload / Fault & By-pass Mode,THDI: notmore than 5%, Noise Levelless than 70db, CERTIFICATIONS& Standard : ISO-9001-14001 Certified,Compatibilitywith DG Genset , Built in Automatic & Maintenance Bypass Switch,Warranty: 2 Years on UPS as well as on Batteries, Battery Make : Exide /Amaron/QuantaMake Preferred/Approved Brand : APC-Schneider/Emerson –Vertiv/Legrand-Numeric.OEM should have own service center in the district (Need to furnish the service centre address & contact details of at least 2 engineers for better services. 16 Supply Installation Testing and Commisioning of 3 X 2.5 sq.mm FRLSTypePower Cable along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 17 Supplying of extension Card 18 5 Amp. 19 Providing & FIXING WIFI Dual Band/AP 20 Supply, Installation, & Testing of Indoor duplex Singlemode patch cord (9/125 μm (OS1/OS2) made of glass fiber optic with LSZH jacket, F8 2.0x4.1 mm, yellow, singlemode G652.D (9/125 μm (OS1, OS2) Mounted on both sides with ST/E-2000/SC/LC/MT-RJ/PC type Duplex connectors in acc. with IEC 61754-20. Zirconia (ceramic) ferrule with a PC polished endface geometry, connectors should be tuned in accordance with IEC 61755-3-1 and qualified in acc. with IEC 61753-1 for category U (uncontrolled environment, duplex clip and white plastic dust cover, should comply to delta IL < 0.2 dB after 500 mating cycles, there should be an optional Visual coding, mechanical coding and lock protection on the patch cords which can be added on later stage. patch cordss performance should be acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, as per requirements. All as pre approved by Executive Engineer in charge. 21 Single Mode Patch Cord 1 Mtr. 22 Single Mode Patch Cord 3 Mtr. 23 Electrical Works / Point Installation with all accessories (as per requirement at site) 24 Connectivity type ILL 10Mbps1:1 with Media OFC /ARC & OTC completeJob.

Key Value

Document Fees
INR 1000 /-
EMD
INR 55320.0 /-
Tender Value
INR 27.66 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail