| 1 | Part \"A\" Civil Work |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil |
| 3 | Anti termite treatment of floor using Imidacloprid 30.5% EC non repellent, odorless, low dose, environmentally safe terniticide with rapid action non corrosive stain free, by drilling 12mm diameter holes 300mm apart injecting the emulsion as per specification and plugging with cement mortar 1:2 ( 1 cement : 2 coarse sand) in the whole floor area DPE 12mm diatermitube system with required number of junction boxes are to be installed. The termitube will run all along the perimeter wall both inside and outside. In the middle area the termitube to be installed at an interval of 1.00 Mtr. or less both ways as required with sufficient number of junction boxes to pump the emulsion. After successful testing of termitube, pesticide emulsion of imidacloprid 30.5% EC mixed with water in the ration of 1:474 will be pumped by a motorized spray pump from the junction box in specified manner. The plinth area of the area treated will be measured for payment. |
| 4 | Excavating trenches by mechanical/ manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 8 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) |
| 9 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases for columns |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 12 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour& pattern over 50mm thick compacted bed of sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filing the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 100 mm thick C.C. paver bock of M-50 grade with approved colour design and pattern. |
| 13 | Front Elevation mirror work (Design Attached) |
| 14 | Mezzanine Flooring (Design Attached)Mezzanine Flooring – First Floor (PEB Work Area) |
| 15 | MFMA-Certified Maple Wood Flooring for 2 CourtsEstimate for Two Badminton Courts with MFMA-Certified Maple Wood Flooring |
| 16 | Providing and fixing aluminium work for doors, windows, ventilators, and partitions in the Indoor Sports Complex (area: 120 ft × 75 ft, including 10 toilet units) shall be carried out using extruded built-up standard tubular sections conforming to IS: 733 and IS: 1285. This includes both fixed portions and openable shutters using powder-coated aluminium sections (minimum coating thickness 50 microns), fixed with dash fasteners, cleat angles, EPDM rubber/neoprene gaskets, stainless steel screws, and accessories as per architectural drawings. (The estimated quantity for fixed portions is 130 kg at a rate of ₹351/kg, and 390 kg for shutters at ₹381/kg. Additional works include fixing 10 sqm of 5 mm thick float glass for glazing at ₹902/sqm, and 42 sqm of 12 mm prelaminated particle board paneling at ₹1,092/sqm. The total estimated cost for the aluminium works for the entire complex.) |
| 17 | providing and fixing lst quality MAT finished c,eremic tilesize 300x300mm confirming to IS : 13755 and IS : 15622colour such as white, grey, ivory, fume red br:own, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cosl of cement mortar bed 1:4). Extra for using size above 200x300mrn in glazed tiles and for using 400mm x 400mm MlrT finished tiles in place of 300mm x 300mm size. |
| 18 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 19 | 20mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) |
| 20 | Providingand applyingwhite cement based putty over plasterd surface to prepare surface even & smooth New surface. Three or more coat |
| 21 | Distempering with oil bound washable distemper of approved brand & manufacture give even shade including .All scaffolding New work( two or more coat ) includingscrapping & priming coat with cement primer |
| 22 | Part \"B\" Sanitary Work |
| 23 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever requiredOne urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 24 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap |
| 25 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge |
| 26 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm |
| 27 | Providing and fixing toilet paper holder : C.P. brass. |
| 28 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete |
| 29 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal outer dia Pipes. |
| 30 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes |
| 31 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes |
| 32 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 40 mm nominal dia Pipes Note: this item includes all types of fittings, brass threaded fittings, sluice valve, gate valve, ball valveof size from 15mm to 160 mm in CPVC |
| 33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 65 mm nominal dia Pipes .Note: this item includes all types of fittings, brass threaded fittings, sluice valve, gate valve, ball valveof size from 15mm to 160 mm in CPVC |
| 34 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore |
| 35 | Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 36 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 37 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore |
| 38 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore |
| 39 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore |
| 40 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore |
| 41 | Part \"C\" ELECTRICAL WORK |
| 42 | The electrical work shall include the supply, installation, testing, and commissioning of complete internal and external electrical systems for the Indoor Sports Complex having a built-up area of 120 ft × 75 ft, inclusive of two badminton courts, 10 toilets, and associated common areas. The scope includes providing main LT panel, sub-distribution boards, internal wiring with FRLS copper cables in PVC conduits, modular switches and sockets, lighting fixtures including high-bay LED lights for the badminton courts ensuring 500–750 lux levels, LED panel and downlights in toilets and common areas, external lighting with high mast poles (12m height) fitted with 4×200W LED floodlights, street/pathway lighting, earthing system as per IS 3043, lightning protection system, and necessary cabling works. Provision for exhaust fans, hand dryers, and water heaters in toilets is also included. All materials, equipment, and workmanship shall conform to relevant IS standards, the National Building Code, and local statutory regulations, ensuring energy efficiency, safety, and functional reliability throughout the complex. Description of Electrical WorksBuilt-up Area: 120 ft × 75 ft (Approx. 9000 sq. ft.) |
| 43 | Part \"D\" PROVIDING, FABRICATING, TRANSPORTING, AND ERECTING A COMPLETE PREFABRICATED BUILDING FRAME (AS PER DRAWING ATTACHED) |
| 44 | Providing, fabricating, transporting, and erecting a complete prefabricated building frame (as per drawing attached) made of pre-engineered steel components, including all primary and secondary structural members such as columns, rafters, jack beams, C & Z purlins, girts, clits, and bracings, fabricated using E350 grade structural steel conforming to IS 2062, sourced from approved manufacturers such as TATA, JSW, AMNS, or SAIL. The scope includes detailing, cutting, drilling, welding, bolting, shot blasting, and the application of one coat of zinc chromate primer followed by two coats of anti-corrosive epoxy or PU paint. C & Z purlins shall be hot-dip galvanized with 120 GSM zinc coating, formed to required sizes. All hardware including anchor bolts, base plates, connecting plates, stiffeners, cleats, gusset plates, and fastening systems shall be included, using 8.8 grade high-tensile bolts, nuts, washers, and self-drilling screws with EPDM washers. Roofing shall comprise Bare Galvalume AZ150 sheets, and wall cladding shall consist of Colour Coated Galvalume AZ150 (Off White), both with minimum 0.47 mm TCT, trapezoidal profile, installed with proper overlaps and sealants. The item also includes supply and installation of 600 mm turbo ventilators with FRP/metallic base plates, placed as per design for natural ventilation; double-layer air bubble insulation with aluminum foil on both sides, fixed beneath roofing sheets for thermal efficiency; and galvanized steel deck sheets (minimum 0.8 mm thick) used as permanent shuttering for composite floor slabs. Further, the work includes providing and fixing polycarbonate sheets (minimum 2 mm thick, UV-stabilized, multiwall or solid type as per design) for natural daylighting in roofing or wall areas, fixed using self-drilling fasteners and compatible sealing systems. Also included are polycarbonate louvers (fixed or operable type), framed in aluminum or steel channels, installed at designated locations to facilitate ventilation and daylight while maintaining weather protection. All materials and workmanship shall conform to IS codes and manufacturer specifications, and the structure shall be completed in all respects to the satisfaction of the Engineer-in-Charge. (Approx.quantity 160 ton) |