| 1 | Taking down cement plaster of any description, on brick or stone walls or ceiling etc. including raking out joints, hacking for key, scrubbing down with water etc complete. |
| 2 | M & L for 15 mm thick rendering in cement mortar 1:4 on other than fair faces of brick or concrete surfaces or stone masonry surfaces of wall, finished even and smooth w/o using extra cement complete. |
| 3 | M&Lfor 15mm thick rendering in cement mortar (1:6) on fair faces of brick or concrete surfaces or stone masonry surfaces of wall,finished even and smooth w/o using extra cementcomplete. |
| 4 | Demolition of cement concrete (reinforced) in roofs,platforms, floors(otherthan ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed. |
| 5 | M & L for reinforced cement concrete type B-0, 1:2:4 (using 12.5 graded granite stone aggr) in Chajjas,column,beam, facia, staircase etc Complete all as spd and dir. |
| 6 | M&L for providing Micro concrete with MICROCRETE in Chajjas,column,beam, facia, staircase etc at the rate of 25kg per 0.0125 m3 with 20% properly graded 5mm to 10mm silt free aggregate as per manufacturer instructions and mixing concrete with mechanically electrically operated mixer machine etc all as specified and directed. Make: CICO MICROCRETE of CICO Technologies ltd or equivalent in Fosroc/STP/BASF |
| 7 | Rough finished flat form wok to Chajjas ,column,beam, facia, staircase, Chullah hoods, water troughs andsimilar items incl sdges and formwork incl necessary struts,scaffolding etc complete all as spd and dir. |
| 8 | M & L for Mild steel bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 9 | M & L for rendering 10mm thick in CM 1:3 on ceiling surface finishedeven and fair without using extra cement complete all as specified and directed. |
| 10 | M & L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as spd and dir. |
| 11 | M & L for prepariation of new plastered surfaces and applying two coats of cement base paint over a coat of alkali resitant primer on surfaces of walls any colour as approved by GE. |
| 12 | M & L for prepariation of new plastered surfaces and applying two coats of distemper oil emulsion including chalkwhitening preparatory to distempering on surfaces of walls. |
| 13 | M & L for prepariation of old surfaces by washing, rubbing down and stopping of painted surfaces and applying one coats of cement base paint (tinted) on surfaces of walls any colour as approved by GE. |
| 14 | M & L for prepariation of old surfaces by washing, rubbing down and stopping of painted surfaces and applying two coats of cement base paint (tinted) on surfaces of walls any colour as approved by GE. |
| 15 | M&L for preperation of old decorated or unplastered surfaces by brooming down and steel wire brushing , scrapping down smoke soot, moulds , moss and efflorescent salts and greasy spot etc, and applying one coat of white wash on wallsincluding all cornices etc. |
| 16 | Description all as per item 14 here - in - before but on ceiling |
| 17 | M & L for prepariation of old surfaces by washing, rubbing down and stopping of painted surfaces and applying one coat of tinted oil bound distemper on walls complete all as spfd. |
| 18 | Description all as per Ser item No 16 above but two coats |
| 19 | Description all as per Ser item No 16 above but on ceiling. |
| 20 | M&L for preperation of old decorated or unplastered surfaces by brooming down and steel wire brushing , scrapping , down smoke soot, and greasy spot etc, and applying one coats of exterior emulsion paint (Apex) on surfaces of walls/Floor surface (VVIP area) any colour as approved by GE |
| 21 | Description all as per Ser item No 19 above but two coats |
| 22 | M&L for preperation of old decorated or unplastered surfaces by brooming down and steel wire brushing , scrapping , down smoke soot, and greasy spot etc, and applying two coats of interior washable paint including one coat of 1mm wall putty complete on wall surfaceany colour as approved by GE |
| 23 | M&L for preparation of old painted wooden surface or wood based materials of any description, not otherwise described, over10 cms widths or girth and applying one coat of synthetic enamel paint complete all as specified any colour as approved by GE |
| 24 | Description all as per Ser item No 21 above but on steel surfaces. |
| 25 | M&L for writing letters or figures (Block, Roman, Italic or Indian) n.exc 15cm high & 2.5cm width with thick synthetic enamel paint over and including one base coat of synthetic enamel paint on plaster or concrete surface for writing of letter. |
| 26 | S & F for 5mm Alluminium composite panel of size n\"exc 0.3m x0.3m for building no of minium letter n\"exc 6 No\"s on a plate fixed with minium 02 nos of fasterners of stainless steel screw complete all as spd and dir by Engineer-in-charge.(colour of sheet/letter as per approval of GE) |
| 27 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 28 | M & Lfor Chequered cement concrete tiles 20cm x 20cm x 25mm thick(with gray cement and no pigment), set, jointed and pointed in neat cement slurry in floors including Screed bed or bedding layer of mortar 15 mm thickin CM 1:6. |
| 29 | M & L for machine pressed precast concrete interlocking paver block rubber moulding any shape and size with grey cement and pigment cnfirming to IS-15658-2006 of 60 mm thickness, M-35 grade over and including 25mm thick sand/stone dust complete all as spfd & directed by Engineer-in-charge. |
| 30 | Demolition of cement concrete unreinforced in groung floors, paving n.exc 15cm thickness (below or above ground level) and precast concrete articles as in kerb walls. |
| 31 | M & L for 75mm thick Plain cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in flooring,sub base,slab flooring, bedded completeas specified and directed by Engineer-in-charge. |
| 32 | M&L PCC1:2:4 typeB-1 (using 20mm graded stone aggregate) as in coping, benching etc incl necessary form work complete all as specified and directed |
| 33 | M & L in repairs for precast reionforced cement concrete 1:2:4 , Type B-0 (Using 12.5mm graded stone aggregate) in 50mm thick jallies or louvers incl all mouldings complete and set in CM 1:4 |
| 34 | S & F for 2mm thick plain/dimond cut factory made Polycarbonate sheet in any colour fix at site of any shape as specified fixing to MS framewith anchor fasteners (min 04 Nos fastener or more ) as per fixing requirment and manufacturer instruction at site complete all as spd and dir by Engineer-in-charge. |
| 35 | M & L Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths)as in other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, complete |
| 36 | M&L for cutting holes into or through brick/stone walls built in cement mortar (nexc 400mm thick), superficial area exc 400 Sqcm nexc 0.10 Sqm and making good in cement mortar 1:3 or PCC 1:2:4: type B-1 as required. |
| 37 | M &L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in Brick /stone wall. |