| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes foundations of poles/stays/pipes etc. not exc 10 Sqm area on plan and getting out in soft/loose soil, complete all as specified and directed by Engr-in-charge |
| 2 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well rammingin layers n. exc. 25 cm thick, complete all as specified and directed by Engr-in-charge. |
| 3 | Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engr-in-charge. |
| 4 | M&L for cement concreate 1:2:4 type D-2 (using 40 mm graded stone aggregate) as in coping etc including necessary form work and finishing the surface with cement mortar 1:4, 5mm thick finished to the portion of PCC muffs above ground level, complete all as specified and directed by Engr-in-Charge. |
| 5 | M&L for PCC 1:4:8 type D-2 (using 40 mm grade stone aggregrate in foundation, mass concrate) as in foundation of poles & stay etc, complete all as specified and directed by Engr-in-Charge. |
| 6 | Material & Labour for dismantling of perished unserviceable ACSR conductor of any size from position care fully with out damaging the exiting PCC pole, complete all as specified and directed by Engr-in-charge |
| 7 | S&F double walled corrugated (DWC) pipe of size 90 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground, complete all as specified and directed by Engr-in-charge |
| 8 | S&F double walled corrugated (DWC) pipe of size 120 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground, complete all as specified and directed by Engr-in-charge |
| 9 | S&F double walled corrugated (DWC) pipe of size 180 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as spd and directed. |
| 10 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16sq mm 4 core, complete all as specified and directed by Engr-in-charge |
| 11 | Description all as per Item No 10.00 here-in-before but size 70 sqmm 3.5 core, complete all as specified and directed by Engr-in-charge |
| 12 | Description all as per Item No 10.00 here-in-before but size 150 sqmm 3.5 core, complete all as specified and directed by Engr-in-charge |
| 13 | Description all as per Item No 10.00 here-in-before but size 300 sqmm 3.5 core, complete all as specified and directed by Engr-in-charge |
| 14 | Supply, Laying, jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 2.5Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable, complete all as specefied and directed by Engr-in-charge. |
| 15 | Supply and fix High performance LED street light, contemporary designed housing made of die-cast aluminium, with street optic lens, for uniform light distributions rated 90WIP 66, complete all as specefied and directed by Engr-in-charge. |
| 16 | Supply and fix 11 Watt IP 65Bollard, made of extruded aluminium housing, to redfine landscapes with better light quality and enhance architectural design, complete all as specefied and directed by Engr-in-charge.Note :- Rate quoted is deemed to be inclusive of PCC foundation/pedestrian and connected earth work. |
| 17 | S&F in replacement of automatic street light control switch of 8 KW three phase using Infrared sensor based Nature Switch for automatic switching of street light. Nature switch operation should be based on Natural Light Lux*level. Reqd illuminance level also have part night operation facility for min 4 hrs to max 12 hrs. The sensor along with suitabe rating power contractor (s), one Incoming and three Outgoing MCBs rating of 20-32 Amps & main load circuit wiring (copper) of min 10 sqmm should be enclosed in a pole/wall mountable rust proof, electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure conforming to IP66 protection class-2 (Hansel make). The circuit should be also have provision for manual operation (i.e. sensor by pass option), complete all as specefied and directed by Engr-in-charge. Model No SWADEEP 66- 8 KW3P or L&T or Havells. |
| 18 | M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth wire 4 mmas earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common salt including PCC pit in PCC 1:2:4 type B-1, RCC covermade out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle andangle iron 40x40x5mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 20 mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion, complete all as specified and directed by Engr-in-Charge.Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge. |
| 19 | Dismantling of unserviceable steel tubular pole swaged pole/PCC pole including PCC complete with acessories, complete all as specified and directed by Engr-in-Charge. |
| 20 | Supply and installation in replecement of Supply and fix steel tubular swaged poles Type 410SP-31(9.0 meter long) Swan Neck Type complete with CI base plate and finial and double swan neck, Including foundation and coping.with necessary Foundation RCC 1:1:5:3 with 8Nos.16 mm dia tor bar as main bars and 8mm dia.Tor bars strips@190mm c/c as this reinforcement shall confirm to IS : 1786 latest edition.The foundation shall extend above surroundings ground/drive way level for 200 mm and have DWC 63 mm dia,PVC sleeve cast foundation for cable entry,Excavation,RCC and reinforcement etc as per manufacturer recommendation and the cost ofnecessary foundation, steel bars, strip as per Manufacturer instructions, complete all as specefied and directed by Engr-in-charge. |
| 21 | S&F in replacement modular boxof size 333 x 233 x 120 mm made of FRP inpact resistance plastic & heat resistant materials including MCB SP 6 A, Connector terminal block 4 pole 16 A capacity and fixing to the street light or post top light pole with suitable sizes of clamps, nuts and bolts, complete all as specefied and directed by Engr-in-charge. |
| 22 | Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system,dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entryand locking arrangement complete including taking downold U/S LT panel/busbar with following, complete all as specefied and directed by Engr-in-charge:- |
| 23 | Incoming(a) MCCB 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, 125 Amps ,with thermal adjustable and fixed magnetic setting with extended terminals-01 No Make:-L&T,Legrand, Scheineiders, Havells(b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 200 Amp,4 pole, not less than 75 cm long mounted on insulators 01 setOutgoing (a) MCCB 4 pole , Ics=100%Icu-25/26 KA, 415 Volts, 63 Amps ,with thermal adjustable and fixed magnetic setting with extended terminals-02 Nos.Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work.(ii) Panels shall be placed above 0.6 mtr from ground level (iii) Outgoing MCCBs shall be fed with solid busbar connectors (iii) Cables shall be terminated using gun metal /SS glands.(vi) includingsuitable thimbles/lugs, nut bolts ,washersfitted the cables(v) cable glands for incoming LT cable 50 sqmm -01 Nos and out going cables 25 sqmm -03 Nosis including rate quated by vendover |
| 24 | Supply, Installaiton, commosioning and testing LT panel outdoor cubical floor mounted type made out of 3.15 mm thick CRCA sheet dulypowder coated complete with Aluminium bus bar having rating of 1000A for 3 phase 4 wire 415volts 50Hz power supply system fixed on angle iron of size 40x40x6mmpanelembedded in 40mm thick PCC 1:2:4 type B-1 (using 20mm graded aggregate) and suitable to accommodate and including the following, complete all as specefied and directed by Engr-in-charge:- |
| 25 | Incoming(a)MCCB 400 amps, 4 pole, 50Hz ,415 V with rupturing capacity 35/36 KA-01 NoL&T /Scineiders/C&S/ABB or Equivelent(b) Bus bar electrolytic grade copper600 amps 4 pole and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators not less than 1 Mtr long mounted on insulators for incomming supply 01 No.Outgoing(a)MCCB 250 amps, 4 pole,35/36 KAwith adjustable thermal over load release50 Hz, 415 volts grade - 01 Nos.(b)MCCB 160 amps, 4 pole, 25 KAwith adjustable thermal over load release50 Hz, 415 volts grade - 02 Nos. (c)MCCB 125 amps, 4 pole, 25 KAwith adjustable thermal over load release 50 Hz, 415 volts grade - 01 Nos.Note:- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestrian and connected earth work. (ii) Panels shall be placed above 0.6 mtr of ground level(iii) Outgoing MCCBs shall be fed with solid busbar connectors.(iv) Cables shall be terminated using gun metal /SS glands.(v) cable glands for incoming LT cable 240 sqmm -1 Nos and out going cables 185 sqmm -01 Nos and 95 sqmm - 02 Nos is including rate quated by vendover |
| 26 | M & L for providing earthing with GI earth plate electrode 600 X 600 X 3.15 mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 25x4 mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR 1996 part 1 ,including necessary excavation and earth work in any strata of soil,comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc, complete all as specefied and directed by Engr-in-charge Note:- All the joints shall be made with welding to get proper conductivity. |
| 27 | Supply & fixfor XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 10 sq mm 4 core, laid in trenches/ducts/through pipe, complete all as specefied and directed by Engr-in-charge |
| 28 | Supply & fixfor XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 120 sq mm ,3.5 core, laid in trenches/ducts/through pipe, complete all as specefied and directed by Engr-in-charge |
| 29 | Supply & fixfor XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 50 sq mm ,3.5 core, laid in trenches/ducts/through pipe, complete all as specefied and directed by Engr-in-charge |
| 30 | Supply & fixfor XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 35 sq mm ,3.5 core, laid in trenches/ducts/through pipe, complete all as specefied and directed by Engr-in-charge |
| 31 | Supply and lay DWC (Double wall corruguated) pipe attachments like coupler, snap-fit and any additional attachmentssuitable for DWC pipe of120/103 mmconforming to IS: 14930/ IS 16205 for protection of LT Cable 150/120 sq.mm, complete all as specefied and directed by Engr-in-charge. |
| 32 | Supply and lay DWC (Double wall corruguated) pipe attachments like coupler, snap-fit and any additional attachmentssuitable for DWC pipe of77/63 mmconforming to IS: 14930/ IS 16205 for protection of LT Cable 35/50 sq.mm, complete all as specefied and directed by Engr-in-charge |
| 33 | Supply and lay DWC (Double wall corruguated) pipe attachments like coupler, snap-fit and any additional attachmentssuitable for DWC pipe of50/38 mmconforming to IS: 14930/ IS 16205 for protection of LT Cable 16 sq.mm, complete all as specefied and directed by Engr-in-charge . |
| 34 | Pole mounted junction box (Street light box) sliding type doors fits to base by 3 phase busbar insulator - 04 Nos (in repair)for street lighting system with nuts and bolts with fixing arrangment, outdoor type of dismension 240 x 130 x 110 mmwith suitable screen printed skull and bones for danger notice on middle and top cover of the box, complete all as specified and directed by Engr-in-Charge.Make - Sintex product code No GSJB-2817or its techno commercial or equivalent from the list of makes given in particular specfification. |
| 35 | Plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate)as in foundations filling and mass concrete, complete all as specefied and directed by Engr-in-charge |
| 36 | Plain cement concrete 1:2:4 type B-1(using 20 mm graded stone aggregate) for coping of poles complete including necessary form work, complete all as specefied and directed by Engr-in-charge |
| 37 | LED street light fitting, 90 Watt, 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts, complete all as specefied and directed by Engr-in-chargeNote: (a) Brackets required for fixing of fitting are inclusive of ratequoted.(b) Necessary grouting/making good on existing surfaces in inclusive of rate quoted.(c) GI pipe of required dimensions if required at site shall be provided by the contractor. |
| 38 | LED Floodlight fitting, 150 Watt, 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts, complete all as specefied and directed by Engr-in-chargeNote: (a) Brackets required for fixing of fitting are inclusive of ratequoted.(b) Necessary grouting/making good on existing surfaces in inclusive of rate quoted.(c) GI pipe of required dimensions if required at site shall be provided by the contractor. |
| 39 | Post top lantern, LED, type 40 watt , 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, complete all as specified and directed by Engr-in-Charge.Note: (a) Brackets required for fixing of fitting are inclusive of ratequoted.(b) Necessary grouting/making good on existing surfaces in inclusive of rate quoted.(c) GI pipe of required dimensions if required at site shall be provided by the contractor. |
| 40 | Supply and erecting steel tubular swaged poles erected to truly vertical or planted as strut complete with 6mm thick mild steel base plate(300mmx300mm), welded to pole, finial taper plug, bolts, nuts, and screws. Poles made out of ERW MS tubing conforming to IS-2713 Part-II Type 410 SP-31, 9.0mtr long including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bitumenous paintinternally and portion embedded in concrete, making five black & white bands at lower portion of pole each 300mm wide alternately upto the height of 1.5 m and marking pole No. with black paint at suitable height including making two nos holes of suitable size in steel tubular pole by gas welding for passing PVC cable connection from junction box to security lights through pole where junction box to be fitted in pole, complete all as specified and directed by Engineer-in-Charge. |
| 41 | S&F in replacement of automatic street light control switch of 18-21 KW three phase(40 Amp per phase) having protection IP-66 using Infrared sensor based Nature Switch for automatic switching of street light. Nature switch operation should be based on Natural Light Lux*level. Reqd illuminance level also have part night operation facility for min 4 hrs to max 12 hrs. The sensor along with suitable rating power contractor (s), one Incoming and three Outgoing MCBs rating of 40 Amps & main load circuit wiring (copper) of min 10 sqmm should be enclosed in a pole/wall mountable rust proof, electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure conforming to IP66 protection . The circuit should be also have provision for manual operation (i.e. sensor by pass option), complete all as specefied and directed by Engr-in-chargeMake - Navdeep with smart timer Model no -Navdeep-66-18kw3or equivalent from the list of makes given in particular specfification. |
| 42 | Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder changeover pillar boxout door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system,dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings and base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entryand locking arrangement complete with following, complete all as specefied and directed by Engr-in-charge :- |
| 43 | Incoming(a) Onload changeover switch 250 amps, 4 pole, 35 KA , with adjustable thermal over load release50 Hz, 415 volts grade - 01 Nos.Make :- L&T,Legrand, Scheineiders, Havells(b) Bus bar electrolytic grade copper600 Amp,4 pole, not less than 1.5 Mtr long SMC insulators mounted on insulators - 01 set(c) MCCB 320amps, 4 pole,35/36 KAwith adjustable thermal over load release 50 Hz, 415 volts grade-01 Nos.Make :- L&T,Legrand, Scheineiders, Havells |
| 44 | Outgoing(a) MCCB 160amps, 4 pole,35/36 KAwith adjustable thermal over load release 50 Hz, 415 volts grade-01Nos.Make :- L&T,Legrand, Scheineiders, Havells(b) MCCB 125 amps, 4 pole,35/36 KAwith adjustable thermal over load release 50 Hz, 415 volts grade-03Nos.Make :- L&T,Legrand, Scheineiders, HavellsNote:- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connection of cables ,connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level(iii) Outgoing MCCBs shall be fed with solid busbar connectors.(iv) Cables shall be terminated using gun metal /SS glands. |
| 45 | Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feederpillar boxout door type, wall mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system,dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings and base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entryand locking arrangement complete with following, complete all as specefied and directed by Engr-in-charge :- |
| 46 | Incoming(a) MCCB 100 amps, 4 pole,35/36 KAwith adjustable thermal over load release 50 Hz, 415 volts grade-03Nos.Make :- L&T,Legrand, Scheineiders, Havells(b) Bus bar electrolytic grade copper200 Amp,4 pole,SMC insulators mounted on insulators - 01 setNote:- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connection of cables ,connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level(iii) Outgoing MCCBs shall be fed with solid busbar connectors.(iv) Cables shall be terminated using gun metal /SS glands. |
| 47 | Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feederpillar boxout door type, wall mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system,dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings and base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entryand locking arrangement complete with following, complete all as specefied and directed by Engr-in-charge :- |
| 48 | Incoming(a) MCCB 63 amps, 4 pole,35/36 KAwith adjustable thermal over load release 50 Hz, 415 volts grade-03Nos.Make :- L&T,Legrand, Scheineiders, Havells(b) Bus bar electrolytic grade copper200 Amp,4 pole,SMC insulators mounted on insulators - 01 setNote:- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connection of cables ,connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level(iii) Outgoing MCCBs shall be fed with solid busbar connectors.(iv) Cables shall be terminated using gun metal /SS glands. |
| 49 | Supply, install,150 amp copperBus barwith enclouser wall mounted size 300 mmX250 mm ,suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system,dust and vermin proof, made of 2 mm CRCA MS sheet for cable entryand locking arrangement, complete all as specefied and directed by Engr-in-charge |
| 50 | S&F double walled corrugated (DWC) pipe of size 77 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground, complete all as specefied and directed by Engr-in-charge |
| 51 | Supply and fix High performance LED street light, contemporary designed housing made of die-cast aluminium, with street optic lens, for uniform light distributions rated 90 WIP 65, complete all as specefied and directed by Engr-in-charge |
| 52 | Supply, Laying, jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 2.5Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable, complete all as specefied and directed by Engr-in-charge. |
| 53 | Supply, install, commissioning and testing of commercial Air Curtain of door opening size 40\" x 78\" unit for prevention of dust and conditioned air losses, single phase, 220V, 50Hz, made out of CRCA sheet of minimum thickness 1.024 mm finished with two coats of red oxide primer and final coat of synthetic enamel paint(oven baked) with MS-CRC 1.024 mm square perforated suction grills, aluminium alloy fans and single phase electric motor, nozzles, etc., completewith fittings and accessories so as to produce 1-1.5 m/s air velocity at floor level for door opening as specified, complete all as specefied and directed by Engr-in-charge. |
| 54 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVCinsulated copper conductor, single core cable in surface/recessed of size 2 x 2.5 sq. mm. + 2.5 sq. mm earth wire(in PVC casing caping), complete all as specefied and directed by Engr-in-charge. |
| 55 | Switch socket combiation 16 Amp, 6 pin, 3 Module, complete all as specefied and directed by Engr-in-charge. |
| 56 | One switch socket Gang Box, complete all as specefied and directed by Engr-in-charge. |
| 57 | Supply, installation, testing and commissioning of 160 KVA, AMF Panel, indoor type, factory made, (C.P.R.I. Approved) suitable of 415 volts, 3 Phase, 4 Wire, 50 HZ, AC Supply, dust weather and vermin proof,, made oout of 2 mm thick sheet, openable front and back side, base angle frame 50X50X6mm, Aluminium bus bar 600 amp. Mounted on SMC/DMC insulators and enclosed on all sides, (Bus bar cross section area 1 sqmm = 1 amp.) for panel shall be powder coated with Siemens grey shade, internal wiring with PVC insulated, strand copper conductor cable on adequate size but not less than 2.5 sqmm and approved manufracturer of L.T. Panel including follwing accessories, complete all as specefied and directed by Engr-in-charge.Make : SMS Panels and Switchgear or equivalant |
| 58 | (a) AC voltmeter 0-500 volts flush type - 01 No Make : AE/IMP/MECO(b) Suitable voltmeter selector switch having ON/OFF- 01 No Make: AE/ IMP/MECO(c) frequency Meter 100 mm square flush type-01 No. Make- AE/IMP/ MECO(d) Ammeter 0-500 amps with CTS flush type- 01 No, Make - AE/IMP/MECO(e) SMPS Battery charger one number. Make: AE/Havells(f) Main supply air break contactor 3 pole 250 AmpMake: Siemens /L&T ABB(g) Alternator air break contactor 4 pole 250 Amp with a separate over load delay for oover load protectio. Make: Siemens/ L&T/ ABB(h) Set of Microprocessor AMF control relays and timer-01 set(i) Mode selector swithch off/auto main test.(j) Set of push buttions starter/stop/acknowledger/test/main/breaker/close trips-01 set.(k) Audion alarm hootere-01 set.(l) KW meter flush type-01No Make: Havells/ Capital/ Jaipur.(m) Power factor meter-01 Nos. Make: Havells/AE/L&T(n) Suitable Rating 4 pole MCCb-02 Nos |
| 59 | Supply and laying in trenches/wall/air armoured cable 100 Vold multi stranded copper conductor calbe of size 2.5sqmm X 8 core for connection fof AMF panel to DG set, complete all as specefied and directed by Engr-in-charge. |
| 60 | Supply and installation Deep freezer hard top 100 litre capacity having single door. (single phase),capacity 100 Liters BEE 3 Star rated capacity,complete all as specefied and directed by Engr-in-charge. |
| 61 | Supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type and disigned for input voltage 130V to 280V with output voltage 230V with accuracy of +- 2.5% andsuitable for Deep Frezer 110 Ltrs,complete all as specefied and directed by Engr-in-charge. |