Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #49383552

Tender For Repairs/ Maint/ Servicing To Various Type Of Fans And Repairs/ Maint/ Servicing To Cooling Appliances At Likabali Mil Stn Under Ge 872 Ews

Issued by Statutory Bodies & Commissions/Committees · likabali, Assam
Tender Value
36.30 Lakhs
Estimated cost
Bid Submission
11 Jun 2025
0 days left
EMD
72600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
likabali → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Repairs/ Maint/ Servicing To Various Type Of Fans And Repairs/ Maint/ Servicing To Cooling Appliances At Likabali Mil Stn Under Ge 872 Ews

BOQ

Name of Work: REPAIRS/ MAINT/ SERVICING TO VARIOUS TYPE OF FANS AND REPAIRS/ MAINT/ SERVICING TO COOLING APPLIANCES AT LIKABALI MIL STN UNDER GE 872 EWS
Sl. No. Item Description
1Taking down and dismantling the ceiling fan 1200 / 1400 mm sweep of any capacity from existing position and removing its allied spare parts for cleaning, servicing, oiling and lubricating and replacement of unserviceable parts such as bearings, bushes, etc and refixing the same fan in its original position with all the parts i.e. down rod, canopies, fan blades, spilt pins, screws, nuts and spring washers etc complete complete all as specified and directed. (Note : (i) Spare parts shall be measured and paid seperately as supply only and rewinding of fan shall be measured and paid seperatly under relevant item here-in-below. (ii) The cleaning, servicing, oiling and lubricating of fans has to be carried at site itself and to be completed withing one hour unless re-winding is required. (iii) The cost of transportation from site of work to workshop and back for rewinding is deemed to be included in the unit quoted rate, (iv) Rewinding shall be carried out in contractor\"s workshop and fan shall be re-fixed at site withing 10 days after taking down from site. Any delay after 10 days shall be panalised @ Rs. 100.00 per day for a maximum of 10 days).
2All as per Serial item No. 01 above but exhaust fan of any sweep of any capacity complete ditto.
3All as per Serial item No. 01 above but air circulators/ pedestal fan/ wall mounting fan of any sweep and any capacity complete ditto.
4M & L for rewinding of Ceiling fan of any sweep after dismantling with super enamelled bareinsulated copper winding wires as per existing gauge and turn to achieve desiredRPM including necessary insulating materials, insulating varnishing, cleaning, packing and reassemblingand testing etc complete all as specified and as directed. ( Note: Also refer Note No. (iv) under Serial item No. 01 above)
5All as per serial item No. 04 above but exhaust fan of 250 to 300mm sweep complete ditto
6All as per serial item No. 04 above but exhaust fan of 350/400mm sweep complete ditto
7All as per serial item No. 04 above but aircirculator/ pedestal fan/ wall mounted fan of any sweep complete ditto
8Supply only ball bearing suitable for Ceiling fanof any sweep complete all as per the existing specifications and as directed(Make :TATA/ SKF / NBC)
9Supply only condenser of 1.5 Mfd suitable for PVC exhaust fan and wall mounted fan of any make and size complete all as specified and as directed. (Make : Havells/USHA/TIBCON)
10Supply only condenser of 2.5 Mfd suitable for ceiling fan and wall mounted fan of any make and size complete all as specified and as directed. (Make : Havells/USHA/TIBCON)
11Supply only condenser of 3.15 Mfd suitable for Exhuast fan and air circulator fan of any make and size complete all as specified and as directed. (Make : Havells/USHA/TIBCON)
12Supply only Fan blades set, powder coated aluminium for ceiling fan of 1200mm sweep of any make/model, Aero dynamically balanced and screwed with suitable size of mild steel screws complete all as per existing specification and as directed.
13Supply only Fan blades set, powder coated aluminium for ceiling fan of 1400mm sweep of any make/model, Aero dynamically balanced and screwed with suitable size of mild steel screws complete all as per existing specification and as directed.
14Supply only brass bush suitable for ceiling fan of any sweep and capapcitycomplete all as per existing specification and as directed. (Make: FAG/NBC/SKF)
15Supply only MS down rod of size 15 mm bore, 18\" long, heavy duty, duly powder coated with matching colour of fan including making holes etc for ceiling fan of any sweep and capacity complete all as per existing specification and as directed.
16Supply only MS down rod of size 15 mm bore, 24\" long, heavy duty, duly powder coated with matching colour of fan including making holes etc for ceiling fan of any sweep and capacity complete all as per existing specification and as directed.
17Supply only MS down rod of size 15 mm bore, 36\" long, heavy duty, duly powder coated with matching colour of fan including making holes etc for ceiling fan of any sweep and capacity complete all as per existing specification and as directed.
18Supply only Oscilating machanism suitable for Wall mounted fan 300/350/400/450mm sweep complete all as per existing specification and as directed.
19Supply only Rubber Bush (Reel Type) standard size and type including suitable size of nuts, bolts etc complete all as per existing specification and as directed.
20S & F in repairs stationary louvers complete with frame suitable for exhaust fan of 380mm sweep made out of powder coated aluminium anodised sheet of Min 1mm thick with non removable blades fixed permanantly at 45 degree angle for protection from rain including aluminium wire mesh of suitable size for bird control Complete all as per the existing specification and as directed.
21S & F in repairs stationary louvers complete with frame suitable for exhaust fan of 400mm sweep made out of powder coated aluminium anodised sheet of Min 1mm thick with non removable blades fixed permanantly at 45 degree angle for protection from rain including aluminium wire mesh of suitable size for bird control Complete all as per the existing specification and as directed.
22M & L for preparation of old painted surfaces of ceiling fan of any size/sweep/make, cleaning all dust etc and painting with one coat of synthetic enamel (1st grade quality white) paint by spraying including filling cavities with fillerand marking same MES No. with parmanent marker etc complete all as directed.(Note: The ceiling fan taken down under Serial item No. 01 above shall be painted and measured under this item.)
23S & F in repairs Switch socket combination 2 in 1, 6 Amp, flush type complete all as specified and as directed
24S & F in repairs plug top, 5 Amps, 3 pin including making connections to existing cables complete all as specified and directed.
25S & F in repair Three core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 1.5 sqmm complete all as specified and as directed.
26Taking down the existing storage type water heater of any capacity of any type and size by disconnecting electric connection, carring out following necessary repair work, tinkering and welding etc. including de-scaling, brushing and thoroughly cleaning the storage tank/inner water tank, removing of hard water deposits,and connected back and re-fixing in orignal position, grounting, testing and commissioning, complete with entire satisfection of Engr-in-Charge:-(a) Checking of all stop cock, pressure release valve, fusible plug etc to ensure free functioning of the parts including Supply and replacement of washer/gasket, nuts etc as required.(b) Inspect overflaw and vent pipes and remove blockages (if any)(c) Checking and rectify earth continuity of the electrical circuits of the geyser and power points(d) Check, maintain and re-fixing thermostat and re-adjust(e) Visual examination of of fusible plugs for its serviceability(f) De-scaling the immersion type heating element and siphon assembly with diluted hydrochloride acid or cear pedette solution(g) Checking of indicator lamp for its serviceability(Note: (i) Spare parts/components of geysers shall be measured and paid seperately as \"supply only\" under respective items here-in-below. (ii) Any minor parts required for smooth functioning of the geyser shall be provided by the contractor without any extra cost to the Govt. (iii) Painting of geyser shall be measured and paid seperately)
27Supply only heating element, 1.5KW capapcity, AC 230 volts, Squar/round/rectangular type, ISI marked complete all as specified and directed.
28Supply only heating element, 2KW capapcity, AC 230 volts, Squar/round/rectangular type, ISI marked complete all as specified and directed..
29Supply only indicator lamp, retangular/round shape, blue/green/red colour suitable for geyser 50/35/25 ltrs capacity complete all as specified and directed.
30Supply only high pressure safety valve/high pressure release valve, dead weight type suitable for geyser of any make and model, ISI marked complete all as directed.
31Supply only thermostate switch with thermal setting 40 to 90 degree capacity and relay, 230 Volts, ISI Marked complete all as specified and directed.
32Supply only glass wools of approved quality as insulating materials in geyser complete all as directed.
33Supply only Apperatus plate as per the existing make and specifications complete all as specified and directed.
34Dismantling and repair to inner shells of geyser of any capacity and of any make by brazing, soldering to leakage portion or patching work as required with using copper plate of 1.5mm thick including shaping to original size including taking down and reassembling the same after repair and including transportation to work shop for repair work and back complete all as directed.
35S & F In repairs, base assembly (inner, chromium plated brass, any shape and size with inlet, outlet, thermostate slot, drain plug and clamp or bolts for fixing heating element as per the existing shape suitable for electric water heater of 25 Litres capacity including necessary powder coating complete all as specified and as directed..
36S & F In repairs, Inner body tank as per the existing shape/size/specifications suitable for electric water heater of 25 Litres capacitycomplete all as specified and as directed.
37S & F In repairs, Inner body tank as per the existing shape/size/specifications suitable for electric water heater of 50 Litres capacitycomplete all as specified and as directed.
38M & L preparing old painted surfaces of geyser, 50 Ltrs capacity, vertical/horizontal type,by scrapping or any other means, denting surfaces applying putty, filling cavities with filler and single coat spray painting with approved Duco Paint on the body including application of Black Paint on steel frame work and writting MES NO with black paintcomplete all as specified and directed.
39S & F in repair heating element, 2KW capapcity, AC 230 volts, suitable for solar Water Heater of 1000 LPD capacity, ISI marked complete all as specified and directed..
40S & F in repair heating element, 3KW capapcity, AC 230 volts, suitable for solar Water Heater of 1000 LPD capacity, ISI marked complete all as specified and directed..
41S & F in repair heating element, 4KW capapcity, AC 230 volts, suitable for solar Water Heater of 1000 LPD capacity, ISI marked complete all as specified and directed..
42S & F in repair Evacuation tube collector of suitable size as per the existing make and specifications, suitable for solar Water Heater of 1000 LPD capacity, ISI marked complete all as specified and directed..
43M & L Sub main wiring with two runs of 2.5 sqmm (Nominal area) single core cable FRLS PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn throughincluding PVC Casing capping of suitable size with all accesories and fittings,fixed to wall/ceiling etc including2.5 sqmm (nominal area) single core, FRLS PVC insulated, multistranded, unsheathed, copper conductor as earth wire and duly connected to common earth point including taking down existing unserviceable submain wiring complete all as specified and as directed by Engineer-in-charge. (Note : Two run cables and one run of earth wire and one run of casing capping will be measured as one length.)
44S & F in repairs Switch socket combination 2 in1, 3 pin, 6 and 16 Amp, flush type, universal complete all as specified and as directed.
45S & F in repairs plug top, 15 Amps, 3 pin including making connections to existing cables complete all as specified and directed.
46S & F in repairs 15mm bore, PVC connection pipe 450mm long with PTMT nuts at both ends complete all as specified and directed.
47S & F in repairs, 15mm bore, Plug type bib taps, cast iron, screwed for iron pipe and fixed complete all as specified and directed.
48S & F in repairs, 15mm bore,angle Stop valve of PTMT,any colour high pressure, screwed for iron pipe and fixed (minimum weight 90 gms) complete all as specified and directed.
49Taking up or down 15mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
50Supply, laying, connection and testing, 15mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
51S & F in repairs MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve,complete all as specified and as directed (Make: Havell\"s cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturer\"s)
52S & F in repair sheet metal enclosure, single door MCB DBs, phosphatised, powder coated, Single pole & neutral (SPN),02 way, 240 Volts suitable for housing MCBs with din rail, neutral and earth bar in proper psoition complete all as specified and directed.
53S & F in repairs sheet metal enclosurewith socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V, B-curve complete all as specified and as directed.
54M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
55M & L for taking down/ lowering defective Split/Window AC 1.5/2.0 TR capacity of any make from any height by disconnecting all electric connections, opening & checking in presence of a Board of Officers (to be convened by GE) to ascertain the quantum of defects and Repair Works involves, Repairing/ replacement of unserviceable Parts, cleaning thoroughly condensing Unit to achive proper cooling effect, checking of electronic circuit of machine, changing of wiring with proper size of PVC insulated Copper conductor wires, Brazing the suction/Discharge tubes (as required) and making the entire system fully leakage proof, Re-install the same in Original/ new positition and providing necessary electric connections, testing on completion complete all as specified and as directed. (Note: (i) Replacement of unserviceable parts such as compressor and other parts and charging of Refrigerant as required shall be measured and paid seperately as \"Supply only\" under respective items and necessary labour element shall deemed to be included in the unit quoted rate (ii) Replacement of minor spares/ parts such as nuts, bolts & washer, worn out cables as per existing size etc to make the System fully fucntional even if not notified by the BOO shall deemed to be included in the unit quoted rate)
56Supply only Blower motor with extended shaft and rotary blade complete all as per the existing make and model, single phase, 230/240 Volts, AC to mathc the same Model and capacity of Indoor Unit of Split AC 1.5/2.0 TR capacity wcomplete all as specified and as directed.
57Supply only Compressor sealed Unit, Rotary type complete all as per the existing make and model, suitable for Split AC 1.5 TR capacity Outdoor Unit complete all as specified and as directed.
58Supply only Compressor sealed Unit, Rotary type complete all as per the existing make and model, suitable for Split AC 2.0 TR capacity Outdoor Unit complete all as specified and as directed.
59Suuply only Cooling Coil/ Condenser Unit complete all as per the existing make and model, suitable for Split AC 1.5/2.0 TR capacity complete all as specified and as directed.
60Supply only Fan motor with Blade complete all as per the existing make and model, suitable for Split AC 1.5/2.0 TR capacitycomplete all as specified and as directed.
61Supply only Indoor Unit complete Set, 230 Volts complete all as per the existing make and model, suitable for Split AC 2.0 TR capacity complete all as specified and as directed.
62Supply only Remote Auto Sensor Unit & RC, complete all as per the existing make and model, suitable for Split/Window AC 1.5/2.0 TR capacity complete all as specified and as directed.
63Supply only Running capacitor 45/50/60 MFD, 230/240 Volts, 50 Hz complete all as per the existing make and model, suitable for Split AC 1.5/2.0 TR capacity complete all as specified and as directed.
64Supply only Starting capacitor 50+4 MFD, 230/240 Volts, 50 Hz complete all as per the existing make and model, suitable for window AC of any capacity complete all as specified and as directed.
65Supply only Power Circuit (PC Plate) complete all as per the existing make and model, suitable for Split AC 1.5/2.0 TR capacity complete all as specified and as directed.
66Supply only Insulation on and around suction and discharge copper piping with 6.0mm thick flexible Thermo Cool Heat Resistant of best quality (as approved) duly scraped with sticking tape complete all as specified and as directed.
67M & L for complete servicing of Indoor and Outdoor unit of Split AC 1.5/2.0 TR capacity of any make and model in situ by cleaning including replacement of air filter in Indoor Unit and testing on completion complete all as specified and as directed. (Note: Replacement of minor spares/ parts required to make the System fully fucntional shall deemed to be included in the unit quoted rate)
68Supply and Changing Refrigerant R-32/R-22 to all type AC unit/ Refrigerator etc complete all as specified and as directed.
69M & L for shifting of Indoor/outdoor unit of Split AC 1.5/2.0 TR capacity to another locations as directed (including taking down and reinstallation) with all accessories including necessary welding, brazing to stop leakages , vaccum test pressure, testing, inserting thick flexible thermo cool and servicing of indoor and outdoor unit and testing complete all as specified and as directed. (Note: Charging of gas shall be measured and paid seperately)
70M & L for Opening of defective Refrigerator of any capacity/ Make/ Model/ Type, removal of blockage by flushing out, Brazing (as required) and making the system fully leakage proof, replacing unserviceable compressor and other parts and re-assembling after necessary repair work and testing on completion complete all as specified and as directed. (Note: (i) Replacement of unserviceable parts such as compressor and other parts and charging of Refrigerant as required shall be measured and paid seperately as \"Supply only\" under respective item and labour element for the same shall deemed to be included in the unit quoted rate (ii) Replacement of minor spares/ parts as required to make the System fully fucntional shall deemed to be included in the unit quoted rate)
71Supply only Bimetal Switch complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
72Supply only Compressor Sealed Unit complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
73Supply only Cooling Coil complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
74Supply only Fan Motor with Blade for Evaporator Unit complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
75Supply only Overload protection Relay complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
76Supply only Thermostat Switch complete all as per the existing make and model, suitable for Refrigerator of any capacity complete all as specified and as directed.
77M & L for complete servicing of Refrigerator of any capacity/ Make/ Model/ Typein situ by cleaning condenser unit, cooling coil and internal parts and testingcomplete all as specified and as directed. (Note: Replacement of minor spares/ parts required to make the System fully fucntional shall deemed to be included in the unit quoted rate)
78M & L for Opening of defective Water Cooler of any capacity/ Make/ Model/ Type, removal of blockage by flushing out, Brazing (as required) and making the system fully leakage proof, cleaning thoroughly Cooling coil to achive proper cooling effect, replacing unserviceable compressor and other parts and re-assembling after necessary repair work and testing on completion complete all as specified and as directed. (Note: (i) Replacement of unserviceable parts such as compressor and other parts and charging of Refrigerant as required shall be measured and paid seperately as \"Supply only\" under respective item and labour element for the same shall deemed to be included in the unit quoted rate (ii) Replacement of minor spares/ parts as required to make the System fully fucntional shall deemed to be included in the unit quoted rate).
79Supply only Blower motor with blade, single phase, 1325 RPM, 230/240 Volts, 50 Hz complete all as per the existing make and model, suitable for Water cooler of any capacity complete all as specified and as directed.
80Supply only Compressor Sealed Unit complete all as per the existing make and model, suitable for Water Cooler of 40/80 Litre capacity complete all as specified and as directed.
81Supply only Compressor Sealed Unit complete all as per the existing make and model, suitable for Water Cooler of 60/120 Litre capacity complete all as specified and as directed.
82Supply only Overload Protector to compressor sealed unit complete all as per the existing make and model, suitable for Water Cooler of any capacity complete all as specified and as directed.
83Supply only Thermostat Switch complete all as per the existing make and model, suitable for Water Cooler of any capacity complete all as specified and as directed.
84Supply only 15mm bore, Push cock, brass, chromium plated having inner and outer threaded and fixed to water cooler complete all as specified and as directed.
85Supply only PVC float valve suitable to fit with water cooler of any capacity complete all as specified and as directed.
86M & L for complete servicing of Water Cooler of any capacity/ Make/ Model/ Typein situ by cleaning condenser unit, Fan motor & Blade, Base Plate including repairs to storage tank and testingcomplete all as specified and as directed. (Note: Replacement of minor spares/ parts required to make the System fully fucntional shall deemed to be included in the unit quoted rate)
87M & L for Opening of defective Deep Freezer 200 to 500 Litre capacity of any Make/ Model/ Type, removal of blockage by flushing out, Brazing (as required) suction and discharge pipe for making the system fully leakage proof, cleaning thoroughly Cooling coil to achive proper cooling effect, checking of electronic circuit machine, replacement of wiring with proper size of PVC insulated copper conductor wires replacing unserviceable compressor and other parts and re-assembling after necessary repair work and testing on completion complete all as specified and as directed. (Note: (i) Replacement of unserviceable parts such as compressor and other parts and charging of Refrigerant as required shall be measured and paid seperately as \"Supply only\" under respective item and labour element for the same shall deemed to be included in the unit quoted rate (ii) Replacement of minor spares/ parts as required to make the System fully fucntional shall deemed to be included in the unit quoted rate)
88Supply only Compressor Sealed Unit complete all as per the existing make and model, suitable for Deep Freezer 310/320 Litre capacity complete all as specified and as directed.
89Supply only Fan motor with blade, single phase, 1325 RPM, 230/240 Volts, 50 Hz complete all as per the existing make and model, suitable for Deep Freezer of 200 to 500 Litre capacity complete all as specified and as directed.
90Supply only Over load Protector to compressor sealed unit complete all as per the existing make and model, suitable for Deep Freezer of 200 to 500 Litre capacity complete all as specified and as directed.
91Supply only Thermostat Switch complete all as per the existing make and model, suitable for Deep Freezer of 200 to 500 Litre capacity complete all as specified and as directed.
92M & L for complete servicing of Deep Freezer, 200 to 500 Litre capacity of any Make/ Model/ Typein situ by cleaning condenser unit, Fan motor & Blade, Base Plate etc and testingcomplete all as specified and as directed. (Note: Replacement of minor spares/ parts required to make the System fully fucntional shall deemed to be included in the unit quoted rate)
93Supply only Relay complete all as per the existing make and model, suitable for Deep Freezer /Refrigerator/ water cooler of any capacity complete all as specified and as directed.
94Supply only Capacitor of 3 to 10 mfd complete all as per the existing make and model, suitable for Refrigerator/ Deep Freezer/ Water Cooler of any capacity complete all as specified and as directed.
95Supply and Changing Refrigerant R-134/ R-600 to all type Refrigerator/ Water cooler/ Deep Freezeretc complete all as specified and as directed.
96M & L for dismantling of Voltage stabilizer 2.0/3.0 KVA capacity, single phase, 240 Volts AC, repairing as required, replacement of burnt transformer, copper wounded, electronic circuit, relays, indicator light, voltmeter, display, switch and socket etc to make the stabilizer fully functional and re-assmebling and re-instal the same and testing on completion complete all as specified and as directed. (Note: (i) Cost of all materials and labour element required to make the System fully fucntional shall deemed to be included in the unit quoted rate)
97M & L for dismantling of Voltage stabilizer 4/5 KVA capacity, single phase, 240 Volts AC, repairing as required, replacement of burnt transformer, copper wounded, electronic circuit, relays, indicator light, voltmeter, display, switch and socket etc to make the stabilizer fully functional and re-assmebling and re-instal the same and testing on completion complete all as specified and as directed. (Note: (i) Cost of all materials and labour element required to make the System fully fucntional shall deemed to be included in the unit quoted rate)

AI Tender Summary

OUR REF NO 49383552
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 36.30 Lakhs
LAST DATE 11-06-2025
Authority
Authority Name Military Engineer Services
Work Description Repairs/ Maint/ Servicing To Various Type Of Fans And Repairs/ Maint/ Servicing To Cooling Appliances At Likabali Mil Stn Under Ge 872 Ews
Basic Detail
Tender No 8729/E8
Bidding Type Tender
Location
City likabali
State Assam
Key Dates
Publish Date 28 May 2025
Submission Date 11 Jun 2025
Open Date 13 Jun 2025
Finance
Tender Value 36.30 Lakhs
Tender Fee 500
EMD 72600
Exemption Available
Document List
94a191ce-d308-4a5f-aa64-e3c1ba097eaf.html
BOQ_796043.xls
Tendernotice_1.pdf
Tenderpages.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 28, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 11, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 13, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

94a191ce-d308-4a5f-aa64-e3c1ba097eaf.html

xls

BOQ_796043.xls

pdf

Tendernotice_1.pdf

pdf

Tenderpages.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender