| 1 | Clearing grass and removal of rubbis up to distance of 30 m out side theperiphery of the area as per technical specification clause 2.2 |
| 2 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. DSR No.15.7.4 |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. As per DSR 2.8.1 |
| 4 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. As per DSR 2.27 |
| 5 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). As per DSR 4:1:8 |
| 6 | Coursed rubble masonry (first sort) with hard stone in foundation and plinth with :Cement mortar 1:6 (1 cement : 6 coarse sand) As Per DSR 7.6.1 |
| 7 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:: Cement mortar 1:6 (1 cement : 6 coarse sand) As per DSR 6.1.2 |
| 8 | Earth fillingwith approved soil with a lift upto 1.5 m laying in layers, breaking clods, dressing to required lines, curves, grade and sections, watering and compaction to meet requirement of table 300.1 and 300.2 with 3 Km Cartage. |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III)As per DSR. 5.1.2 |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Mild steel and Medium Tensile steel bars As per DSR 5.22.1 |
| 11 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes inCement mortar 1:6 (1 cement : 6 coarse sand) As per DSR6.4.2 |
| 12 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.As Per DSR. 11.3.1 |
| 13 | Providing and fixing glass strips in joints of terrazzo/ cement concrete floors. 40 mm wide and 4 mm thick.As Per DSR 11.13.1 |
| 14 | 12 mm cement plaster of mix : with 1:4 (1 cement: 4 fine sand)As Per DSR 13.1.1 |
| 15 | 15 mm cement plaster on the rough side of single 1:4 (1 cement: 4 fine sand) As Per DSR 13.2.1 |
| 16 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. DSR 13.26 |
| 17 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre :As per DSR 13.41.1 |
| 18 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.As Per DSR. 11.3.1 |
| 19 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. (size 600x600 mm) As per DSR 11.41.2 |
| 20 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces As per DSR 10.5.1 |
| 21 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. . AS Per DSR 12.43.2 |
| 22 | Deduct Remaining Brick Cost |
| 23 | Supply and fixing of granite stone including lettering and painting etc |
| 24 | ( Rates in BOQ are exclusive of G.S.T. Amount ) |