| 1 | Excavation in trenches / post holes in Soft/ loose soil not exceeding 1.5 mtrwide and not exceeding 1.5 meter in depth for taking out and laying pipe lines not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottomsurfaces to required level.Complete all as specified and as directed. |
| 2 | Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point.Complete all as specified and as directed. |
| 3 | Returning filling in including spreading leveling watering and well ramming in layers n.exc 25cm thick in soft/loose soil.Complete all as specified and as directed. |
| 4 | M&L sand cushioning for U/G cable 8 cm before laying the cable and 15cm after laying and stretching the cable cComplete all as specified and as directed. |
| 5 | M&L fly ash bricks well burnt old size designation 75laid dry flat for protection of cable .Complete all as specified and as directed. |
| 6 | M&L PCC M-7.5 (Nominal mix) Type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete for foundation concrete in poles/stays.Complete all as specified and as directed. |
| 7 | M&L PCC M-15 (Nominal mix) Type B-1 using 20mm graded stone aggregate for coping as in benching incl weathering slightly rounded, chamfered angles and finishing exposed surfaces even and smooth incl necessary formwork.Complete all as specified and as directed. |
| 8 | Disconnecting and taking out from trenches/taking down from pole unserviceable LT UG cable of any size and removal from site.Complete all as specified and as directed. |
| 9 | Supply, laying and testing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 sq. mm 3.5 core complete alls as specified and directed |
| 10 | All as per item No 9 here-in-before but of size 95 Sqmm 3.5 Core. |
| 11 | All as per item No 9 here-in-before but of size 70 Sqmm 3.5 core. |
| 12 | All as per item No 9 here-in-before but of size 50 Sqmm 3.5 core. |
| 13 | All as per item No 9 here-in-before but of size 35 Sqmm 3.5 core. |
| 14 | All as per item No 9 here-in-before but of size 25 Sqmm 3.5 core. |
| 15 | All as per item No 9 here-in-before but of size 16 Sqmm 4 core. |
| 16 | All as per item No 9 here-in-before but of size 10 Sqmm 2 core. |
| 17 | M&L 40 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, complete all as specified and directed including clamps, nut, bolt and washers.Complete all as specified and as directed. |
| 18 | All as per item Serial No 17 here-in-before but for 80 mm dia pipe. |
| 19 | Boring under road and foot path for inserting 40/50 mm bore GI tubing for drawing UG cable, complete all as per specified and directed. |
| 20 | All as per item Serial No 19 here-in-before but for inserting 80/100 mm bore pipe. |
| 21 | Supply and fixing panel mounted voltmeter in 96x96 Sqmm flush mounted case Three phase Class 0.5, including fixing in the existing panel complete all as specified and directed. |
| 22 | Supply and fixing panel mounted Ammeter in 96x96 Sqmm flush mounted case Three phase Class 0.5, including fixing in the existing panel complete all as specified and directed. |
| 23 | Supply and fixing panel mounted VAF & VAF +meter in 96x96 Sqmm flush mounted case Three phase Class 0.5 with display of voltage, current & frequency, including fixing in the existing panel complete all as specified and directed. |
| 24 | Supply and fixing panel mounted multifunction energy meter in 96x96 Sqmm flush mounted case 3 lines seven segment display, 3 phase 3 or 4 wire CT-PT operated multifunction meter of class 0.5s accuracy with RS485 and THD for V&I, including fixing in the existing panel complete all as specified and directed. |
| 25 | Supply & Fixing in repl of u/s with new MCCB 4 pole 415 Volts adjustable thermal & fixed magnetic setting Ics=100% Icu type of capacity 63 Amps, 16 KA breaking capacity fixed properly at existinglocation and connecting/testing complete all as directed. |
| 26 | All as per Item No 25 here-in-before but of capacity 100 Amps, 16 KA breaking capacity complete all as directed. |
| 27 | All as per Item No 25 here-in-before but of capacity 125 Amps, 16 KA breaking capacity complete all as directed. |
| 28 | All as per Item No 25 here-in-before but of capacity160 Amps, 36 KA breaking capacity complete all as directed. |
| 29 | All as per Item No 25 here-in-before but of capacity200 Amps, 36 KA breaking capacitycomplete all as directed. |
| 30 | All as per Item No 25 here-in-before but of capacity250 Amps, 36 KA breaking capacity complete all as directed. |
| 31 | All as per Item No 25 here-in-before but of capacity400 Amps, 36 KA breaking capacity complete all as directed. |
| 32 | All as per Item No 25 here-in-before but of capacity630 Amps, 50 KA breaking capacity complete all as directed. |
| 33 | Supply and fixing in replacement of u/s with new changeover switch with enclosure of capacity 100 Amps, 4 pole, 8kA Icw for 1 sec fixed properly at existinglocation and connecting/testing complete all as directed. |
| 34 | Supply and fixing in replacement of u/s with new changeover switch with enclosure of capacity 250 Amps, 4 pole, 12.5kA Icw for 1 sec fixed properly at existinglocation and connecting/testing complete all as directed. |
| 35 | Supply and fixing in replacement of u/s with new changeover switch with enclosure of capacity 400 Amps, 4 pole, 12.5kA Icw for 1 sec fixed properly at existinglocation and connecting/testing complete all as directed. |
| 36 | S&F in replacement of Distribution board (DB) made out of sheet metal enclosure (CRCA sheet steel),RAL 9003, Powder coated dust and vermin proof,VTPN6 way with 200 Amps rated copper bus bar double metal doorprotection, neutral bar,earth bar, with provision of 4 pole MCCB 63/100 as incomer and SP/TP/TPN MCBs as outgoing complete all as spd and directed. |
| 37 | S&F in replacement of Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof,TPN4 way with 200 Amps rated copper bus bar double doorprotection, neutral bar,earth bar, single pole and neutral415 volts complete all as spd and directed . |
| 38 | All as per ser item No 37 here-in-before but TPN8 way |
| 39 | Supply and fixing 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 40 | All as per item No 39 above but SPN 32 Amps |
| 41 | All as per item No 39 above but TP 25 to 63 Amps |
| 42 | All as per item No 39 above but TPN 40 to 100 Amps |