| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Make: Polycab/ Finolex/ L&T) |
| 2 | Group C |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Make: Polycab/ Finolex/ L&T) |
| 4 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 5 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 6 | 2 X6sq. mm + 1 X 6 sq. mm earth wire |
| 7 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 8 | 4 X 10sq. mm + 2 X 6 sq. mm earth wire |
| 9 | Supplying and fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required Make- L& T/ABB/LEGRAND /INDOASEAN |
| 10 | Supplying and fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Make- L& T/ABB/LEGRAND /INDOASEAN |
| 11 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) Make- L& T/ABB/LEGRAND /INDOASEAN |
| 12 | 12way , Double door |
| 13 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 125 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCCBs and incomer ) as required . (Note : Vertical type MCCB TPDB is normally used where 3 phase outlets are required.) Make- L & T/ABB/LEGRAND /INDOASEAN |
| 14 | 8 way (4 + 24), Double doorMake- L& T/ABB/LEGRAND /INDOASEAN |
| 15 | 4way (4 + 24), Double doorMake- L& T/ABB/LEGRAND /INDOASEAN |
| 16 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required |
| 17 | 100 A, 30 kA,FP MCCB Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider |
| 18 | 200 A, 36 kA,FP MCCB Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider |
| 19 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make L&T/ABB/C&S/Legrand/Hagger/Schneider |
| 20 | Single Pole MCB Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider |
| 21 | Double Pole MCB Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider |
| 22 | Triple Pole MCB Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider |
| 23 | FP MCB 40/63 A Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider |
| 24 | 2 Way Enclosure Metal Box |
| 25 | 4 Way Enclosure Metal Box |
| 26 | Supply & laying of 3.5CX120 Sqmm Aurmoured Aluminium cable XLPE Cable and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface oras per the siterequirement . Make: KEI/ Gloster/ Universal./Polycab |
| 27 | Supply & laying of 3.5CX95 Sqmm Aurmoured Aluminium cable XLPE Cable and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface oras per the siterequirement . Make: KEI/ Gloster/ Universal./Polycab |
| 28 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 29 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) |
| 30 | Providing,installation, fixing,Connecting and Testing of LED Batten,4 Feet,20W, as per site requirment. (Make: Wipro/ Philipse/CG/Polycab/ ) |
| 31 | Supplying Installation, testing and commisioning of following Energy Efficieny recess mounted LED Luminarie suitable for 36w,2X2 Grid Ceiling having flat diffuser & constant current electronic driver complete with all accessories & lampsincluding making hanging arrangement using chain etc. and connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc as reqd. (Make Philips Cat No-(Make Philips Cat No-RC375B LED 365 865/840 PSU W60L60 52 WH/ Equivaent inWipro)Make-Phillipse/Wipro/CG/Polycab |
| 32 | Providing,Installation,Fixing,Connecting and Testing of IP 66,System efficacy,>110/120 LPW, LED Flood Light-100 W, as per site requirment. (Make: Philipse/ Wipro/Crompton / Polycab) |
| 33 | Supply & Installation of 12Watt ,System efficacy,>110/120 LPW round false ceiling surface mounted,LED Panel ceiling Surface Light Make:Phillipse/Wipro/CG/Polycab |
| 34 | Supplying and fixing of 230VAC 1Ph. 1400mm dia Ceiling Fan (High Speed).(Make: Usha / Crompton / Orient) |
| 35 | Supplying and fixing of 230VAC 1Ph.400 mm ,900 rpm Wall FanMake: Usha / Crompton / Orient |
| 36 | Supplying,Cutting of huck , painting and fixing ofMS Down rod conduit pipe forinstallation of ceiling fan upto 5 to 8 feet |
| 37 | Supplying and fixing of 230VAC 1Ph.Two module steeped type fan electronic regulator |
| 38 | Repairing of existing old wiring/ board/main switch any loose electrical system ,Shadeling of cable andDismentaling of old unused electrical installation as per the site requirenmen and engineer incharge instructions. |
| 39 | Step/Foot light with IP65 protection for outdoor application -Cat. Ref.-611-06-57-SL-CP-NGG-Crompton or equivalent in Wipro/Phillips/Polycab |
| 40 | 100 Amp Changeover switch-Disconnector in sheet steel enclosure with Cat no. CO11000OSOO- L&T Equivaent with ABB/C&S/Legrand/Hagger/Seimens/Schneider |