}

Tender For Operation And Maintenance Of Water Supply Scheme At Sector 14 Goverdhan Vilas Zone Under Uwss Udaipur For Five Years On Single Point Responsibility Basis - 1 Maintenance Of Pipelines Irrespective Of Size & Material Which Includes Repairing Of, udaipur-Rajasthan

Public Health Engineering Department has published Tender For Operation And Maintenance Of Water Supply Scheme At Sector 14 Goverdhan Vilas Zone Under Uwss Udaipur For Five Years On Single Point Responsibility Basis - 1 Maintenance Of Pipelines Irrespective Of Size & Material Which Includes Repairing Of. Submission Date for this Tender is 17-06-2025. Water Supply Project Tenders in udaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

49361087
Tender For Operation And Maintenance Of Water Supply Scheme At Sector 14 Goverdhan Vilas Zone Under Uwss Udaipur For Five Years On Single Point Responsibility Basis - 1 Maintenance Of Pipelines Irrespective Of Size & Material Which Includes Repairing Of
Tender
Indian
Rajasthan
Udaipur
17-06-2025

Tender Details

Tender For Operation And Maintenance Of Water Supply Scheme At Sector 14 Goverdhan Vilas Zone Under Uwss Udaipur For Five Years On Single Point Responsibility Basis - 1 Maintenance of pipelines irrespective of size & material which includes repairing of bursts & leakages pollution control, survey & removal of choking, disconnection of illegal connections,collection & recording minimum 10 nos residual chlorine samples during daily supply timings, interconnections and all works related to pipeline network in existing distribution / rising main pipelines of all sizes by digging out suitable size of pit in soft and loose soil / hard soil including cutting of black top, WBM & CC top of road of any size at work site. this will also include cutting of pipe ends, fixing of pipe piece with jointing material to make reapir leak proof and then refilling of excavated trench/pit/road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. For entire job contractor will use his own resources shall arrange de-watering, JCB & Tractor compressor if any and restore any amenity at his own cost damaged while performing the work in this item. The work includes daily patrolling and repair the leakages within stipulated time and complete maintenance of pipeline network within the scope of work for per km pipe line per month.Jointing material shall be provided by the dept. Minimum labour for a following kms pipelins to be deployed 2 1 km to 50 km - one fitter -II & one beldar(Rising & Distribution pipeline) 3 Running expenditure of pumphouses which includescomplete operationof pumpmotor maintenanceof log-booksas directed by Engineer- in-charge,generalupkeepingof premises,security arrangements, RegularchemicaldosinginCWR, cleaning and desilting of SR/CWR/SUMP once everysixmonths,dailyvalveoperationunderthe Campusofpumphouseandallotherworksas mentionedin scopeof work in tender documentfor perpumphousepermonth.(powersupply minimum 16 hrs)(excluding repairing of pumping machinery etc.) 4 Upto 100 HP I Block PH 5 Running expenditure of pump houses which includes complete operation of pump motor, maintenance of log-books as directed by engineer-in-charge, general upkeeping of premises, security arrangements, regular chemical dosing in CWR, cleaning and desilting of SR/CWR/SUMP once every six months, daily valve operation under the campus of pump house and all other document for pump house per month. (power supply minimum 8 hours) (excluding repairing of pumping machinery etc.) 6 Upto 50 HP S-2 Block PH 7 Maintenance of centrifugal pump sets and motor/ monoblock including cost of rewinding of motor, material components & accessories required to repair pumpsets, starters etc. Of electric panels, deintallation and re insastallation of pumpsets complete in all respect for per centrifugal pump set with panel pe month. Maintenance of history sheet as directed by engineer-in-charge for centrifugal pump set per month. Operated load of centrifugal pump sets ( HP) 8 13.0 HP to 20.0 HP 2 No. 9 21.0 HP to 30.0 HP 2 No. 10 31.0 HP to 40.0 HP 2 No. 11 41.0 HP to 50.0 HP 2 No. 12 71.0 HP to 80.0 HP 2 No. 13 Maintenanceof tubewellswhich includes round the clock monitoringoftubewellsof all sizes, complete repairs/ rewindingof submersiblepump sets includingcostof materialcomponentsrequiredto repairpumpsets,starters,metersetc.ofelectric paneloftubewells,Loweringandunloweringof pumpsetscompleteinallrespect,maintenanceof log-books & Histroy sheetas directed by Engineer- in-charge for tubewell per month. For Urban water supply schemes. 14 0.5 HP to 5.0 HP 2 No. 15 6.0 HP to 7.5 HP 3No. 16 8.0 HP to 10.0 HP 3No. 17 Maintenanceofopenwellswhichincludesroundthe clock monitoring of open wells , complete repairs/ rewindingofsubmersible/MonoBlockpumpsets includingcostof materialcomponentsrequiredto repair pumpsets,starters,metersetc.of electricpanaloftube wells,Loweringandunloweringofpumpsetscomplete in all respect,maintenanceof log-books& History sheet asdirected byEngineer-in-chargeforOpen well permonth. 18 6.0 HP to 7.5 HP 3 No. 19 8.0 HP to 10.0 HP 1No. 20 Daily/ periodical operation ofvalves at supply times forspecifiedbydepartmentpersluicevalveper month.(Valve rod and cap to be arranged by contractor) 21 80-300mm (46 No.) 22 350mm-800mm ( 2 No.) 23 Cleaningof OverHead ServiceReservoir( OHSR) of belowmentionedcapacity including removalofallsilt from reservoir,scrapping ofwalls, disinfectionof reservoiraftercleaninganddisposalofsiltupto1.00 Km lead and painting the date of cleaning on the reservoir. 24 301 to 400 KL (1No.) 25 401 to 500 KL (1No.) 26 501 to 600 KL (2No.) 27 1101 to 1200 KL(2No.) 28 Providing & fixing of power factor control capacitor panel with mtc. On monthly rental basis. The responsibility of contractor is to maintain minimum power factor as 0.96 if the contractor is failed to maintain minimum PF and any surcharge on this account is levied by JVVNL the same shall be deducted from payment of contractor.(512 HP) 29 Istyear O&M Amount 30 2nd year O&M Amount (including 5% escalation) 31 3rd year O&M Amount (including 5% escalation) 32 4th year O&M Amount (including 5% escalation) 33 5th year O&M Amount (including 5% escalation)

Key Value

Document Fees
INR 5000 /-
EMD
INR 432440.0 /-
Tender Value
INR 2.16 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail