| 1 | Part \"A\" Road work Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compactionground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 305.3.4 as per MoRTH Specification Clause 301.3.11 |
| 2 | Excavation for roadwork in soil with hydraulic excavator of0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per MoRTH Specification Clause 301.3 |
| 3 | Removal of defective concrete, cleaning the surface thoroughly, applying the shotcrete mixture mechanically with compressed air under pressure, comprising of cement, sand, coarse aggregates, water and quick setting compound in the proportion as per clause 2807.1., sand and coarse aggregates conforming to IS: 383 and table 1 of IS: 9012 respectively, water cement ratio ranging from 0.35 to 0.50, density of gunite not less than 2000 kg/cum, strength not less than 25 Mpa and workmanship conforming to clause 2807.6. |
| 4 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300-1 and 300-2 with a lead upto 50 m as per MoRTH Specification Clause 305.3 |
| 5 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per MoRTH Specification Clause 202.By Mechanical Means Cement Concrete |
| 6 | Providing laying spreading and compacting specified graded sand, gravel (crushed stone) as per Table 400-1,400-2 or any other course material as per design mix, as per CBR in sub base course including premixing the material at OMC in wet mix plant, carriage of mixed material spreading in uniform layers with motor grader F.E loader on a prepared base and compacting with vibratory roller to achieve desired density (as per I.S.2720) including all material, labor, machinery, lighting guarding, barricading and maintenance of diversion complete.[MoRTH specification : Clause 401]. By mechanical means. For Grading-III Material |
| 7 | Part \"B\" C.C. Pavement work Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing. |
| 8 | Construction ofun-reinforced , plain cement concrete pavement M30 (Grade), thickness as per design, over a prepared sub base, with 43/53 grade cementas per Clause 602, coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 31.5 mm, mixed in a in fullyautomatic Batching Plant andtransported to site intransit mixer for having continuous agitated mixer, manufactured as per approved mix designincluding pumping of R.M.C. from transit mixer to site of laying , with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge laid with a Fixed Form Paver (laying and fixing of 125 micron thick polythene Film and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days using water finishing to lines and grade as per drawingand MoRTH Specification Clause 602 including vaccum dewatering process with all required equipments (Dowel Bars will be paid seprately). |
| 9 | Part \"C\" Side Drain work Earth work in excavation for foundation of structurecompletewith all lift, dewatering, shoring and shuttering etc. including refilling of trenches in 250 mm layers, ramming, watering and disposal of surplus earth with all lifts and lead upto 1000 meters exclusive of compensation of earth as per MoRTH specification Clause 301 to 305. In ordinary soil Depth upto 3 metre Depth upto 3 metre |
| 10 | Providing and laying mechanically mixed and vibrated Cement Concrete in foundation upto a depth of 1.5 metres below ground level and 1.50 metres above Ground/Bed level as per MoRTH Specification : Clause 1000 & 1700 P.C.C. 1:4:8 mix with crushed stone aggregate 20 mm nominal size. |
| 11 | ProvidingandlayingPlaincement concrete mix with stone aggregate 20 mm nominal size mechnicallymixedandvibrated in foundationup toadepthof1.50 metresbelow ground leveland/or1.50 metres aboveground/bed level as per MoRTH specification : clause 1000 & 1700. with all lead R.C.C. grade M-20 in bed platesupto ground level excluding cost of steel reinforcement but including the cost of centering & shuttering |
| 12 | Providing & fabricating steel reinforecemnt for RCC work including cutting, bending, placing in position and binding complete including cost of binding wire as per MoRTH Specification : Section 1000 & 1600 TMT Steel reinforcement |
| 13 | Providing and fixing factory-made precast RCC U-shape drain ( Precast T-6 ) drain covers, having of strength not less than M-50 using Thermo- Mechanically Treated bars. (TMT/TMX) FE 500D or more conforming to IS 1786 reinforcement bar and capable of carrying a wheel load of 5.0 Tones for heavy vehicle movement, of size Lid for U-300x300 mm. As per standard size reinforced with 8 mm dia main longitudinal & 6 mm nos cross- sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 2 nos, including providing edge binding with M.S. flats of size 50 mm x 1.60 mm complete, all as per direction of Engineer-in-charge.450x450 |
| 14 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 2905. 300mm Dia. |
| 15 | Providing and fixing of reinforced ferro-cement drain cover designedduly marked on cover with adequate steel reinforce- ment having thickness 75mm to 150 mm, anti-corrosive bitumen painted M.S. plate, rim and on M.S. lifting hooks, admixture like plastisizer bond-improving compound, shrinkage resistant compound, abrasion resistant complete as per approved design etc. --do--class \"AA\" loading 600 x 800 mm (125 mm thick) |
| 16 | Part \"D\" Road FurnitureReinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRTH Specification Clause 801 |
| 17 | Ordinary Kilometer Stone (Precast) |
| 18 | 200 m stone (precast) |
| 19 | Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing and Specifications. 900 mm equilateral triangle. |
| 20 | Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and required message, letters, figures with reflective engineering grade tape of required shade and colour.Supported and welded on 47 mm x 47mm of 12 SWG Squaretube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Specification upto 0.9 sqm size board |
| 21 | Providing and fixing Mukhya Mantri Sadak Yojana/ Mahatma Gandhi Rajya Sadak Yojana informatory sign board with logo for roads funded by State road fund having M.S. Definition plate of 1.60 mm thickness frame to steel hollow dsection of 75mm x 75mm, 2.5m long stove enamelled paint with hold fast including paint logo as per approved design and colours. The logo shall be made out of 1.6mm thick circular plate duly framed with MS angle 25x25x5 mm on back and fix on 1200mm x 150mm rectangular steel base plate 1.6mm thick, the base of circular shall be plain at the junction of base plate. The size of definition plate shall be 1500x600mm and embedding the posts by M-15 cement concrete block45 cm x 45 cm x 60 cm, 60 cm below ground levelincluding lettering / writing and painting etc. complete in all respect.as per MoRTH Specification Clause 801. |
| 22 | Construction of speed breaker of IRC standard having width of 3.70 M including cost of stone aggregate (50-25mm) size hire charges for roller for consolidation and compaction and other machines required for the work (including cost of bitumen) |
| 23 | Part \"E\" Protection & C.D.WorkEarth work in excavation for foundation of structurecompletewith all lift, dewatering, shoring and shuttering etc. including refilling of trenches in 250 mm layers, ramming, watering and disposal of surplus earth with all lifts and lead upto 1000 meters exclusive of compensation of earth as per MoRTH specification Clause 301 to 305. In ordinary soil Depth upto 3 metre |
| 24 | Providing and laying mechanically mixed and vibrated Cement Concrete in foundation upto a depth of 1.5 metres below ground level and 1.50 metres above Ground/Bed level as per MoRTH Specification : Clause 1000 & 1700 P.C.C. 1:3:6 mix with crushed stone aggregate 20 mm nominal size. |
| 25 | Providing and laying Precast reinforced cement concrete Box culvert section of M-40 grade designed for \"AA\" class loading as per IRC specifications including to effect of impact, EQ etc. complete on firm base of 200mm thick lean concrete of M-10 grade with aggregate of size 40mm nominal of following internal size the work includes required safety measures cost of design of RCC Precast Box and its proof checking from IIT / NIT / Government Engineer College complete in all respect as per specifications. Size 1.00 M x 1.00 M |
| 26 | Providing and laying stone masonry work in cement mortar with mechanical mixer for foundation (any level) complete including all scaffolding etc. but excluding pointing and plastering as per drawing and technical specification as per MoRTH Specification : Section 1000,1400 Random rubble masonry \"In cement mortar 1:6 |
| 27 | Providing Cement plaster 20mm thick in cement mortar 1:3 at all levels as per MoRTH Specfication: Clause:1000 & 1300 |
| 28 | Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : |
| 29 | Construction of Foundation / Inaugration Pedastal in 23 cm thick Brick masonry in CM 1:4 of size 1.20m x 1.80m above ground level with adequate foundation including providing and fixing of Granite stone of size 0.75m x0.60m with engraving letters and figures,cement plaster,white washing etc. complete as per direction of Engineer in charge. |