| 1 | FRP BASED UNDERGROUND PACKAGED SEWAGE TREATMENT PLANT OF CAPACITY 25KLD WITH IMTTWST 15KL(P)Supply, installation and commissioning of underground packaged sewage treatment plant (capacity 25KLD) of MBBR Technology havingi) Chop whoop winding process based FRP package STP tank inclusive of all four zones ( Solid separation, Anoxic, MBBR Aeration zone, Sedimentation zone) Tank-1 of size 7932 mm (L) x 2430mm dia or as per manufacturer\"s drawing(ii) Chop whoop winding process based FRP intermediate cum treated water storage tank inclusive of two zones Tank-2 of size 4310mm (L) x 2430mm (dia) or as per manufacturer\"s drawing(iii) Submersible Raw sewage Transfer pumps (Cutter Type) -1 Working + 1 stand by for sump, Treated water transfer pump (1 working + 1 Stand By), One number sludge recirculation pump (submerisible), Twin lobe air blowers, PVC return sludge pipe 50mm dia, PVC inlet and out let pipe of 150mm dia, pvc interconnection pipes of 150mm dia, FRP straps, Turn buckle wire rope, concrete deadman, and eye bolts per the diameter and length of the tank, manhole cover as per the requirement, pvc air vent nozzle of dia 50mm, etc. Complete in all respect for running the plant successfully. (iv) Scope of work includes installation of 25KLD FRP tank along with FRP intermediate cum treated water storage tank of 15KL capacity with partition as per drawing and size of the tank along with electro mechanical items. The tank should be laid at an adequate depth below the sewage pipe at the site. The tank shall be installed exactlt as per the manufacturer\"s approved installation drawing. (v) Supply, installation, testing and commissioning of cubical type M.C.C panel of suitable size suitable for 415V, 3phase, 4wire 50Hz AC.Rate includes all plumbing and cabling material within batery limit 5 meter. (VI) Supply of teritary treatment plant with PSF filter, ACF filter, multi port valves 02 nos, filter feed pumps (1W+1S) and chlorine dosing system of 3 cum per hour.(Vii) Pressure sand filter capacity 3 cum/hr, MOC : FRP, Make Pentair or any approved make, Filter media : Pebbles and Filtering sand, piping : PVC-1 No(Viii) Activated Carbon filter capacity : 3 cum/hr, MOC : FRP, Make : Pentair or any approved make, filter media : Activated carbon 900 I/V : Piping : PVC-1No(ix) Filter Feed Pump : Make Lubi/Kirloskar, Capacity 9 cum/hr, Type Submersible (1W+1S)(x) Chlorine dosing system of 0-6 LPH pump with dosing drum.Treated sewage water should fulfill the following criteriaPH value 6.5-8.5, BOD <10mg/litCOD <100mg/Lit, TSS<20mg/Lit, FOG <5mg/Lit, Total Nitrogen < 10mg/lit |
| 2 | FRP BASED UNDERGROUND PACKAGED SEWAGE TREATMENT PLANT OF CAPACITY 50KLD WITH IMT/TWST 20KL(P) and TTP 3.0 CumSupply, installation and commissioning of underground packaged sewage treatment plant (50KLD) of MBBR Technology havingi) Chop whoop winding process based FRP package STP tank inclusive of all four zones ( Solid separation, Anoxic, MBBR Aeration zone, Sedimentation zone)Tank-1 of size 13000 mm (L) x 2430mm dia or as per manufacturer\"s drawing(ii) Chop whoop winding process based FRP intermediate cum treated water storage tank Tank-2 of size 5520mm (L) x 2430mm (dia) or as per manufacturer\"s drawing(iii) Submersible Raw sewage Transfer pumps (Cutter Type) -1 Working + 1 stand by for sump, Treated water transfer pump (1 working + 1 Stand By), One number sludge recirculation pump (submerisible), Twin lobe air blowers, PVC return sludge pipe 50mm dia, PVC inlet and out let pipe of 150mm dia, pvc interconnection pipes of 150mm dia, FRP straps, Turn buckle wire rope, concrete deadman, and eye bolts per the diameter and length of the tank, manhole cover as per the requirement, pvc air vent nozzle of dia 50mm, etc. Complete in all respect for running the plant successfully. (iv) Scope of work includes installation of 50KLD FRP tank along with FRP intermediate cum treated water storage tank of 20KL capacity with partition as per drawing and size of the tank along with electro mechanical items. The tank should be laid at an adequate depth below the sewage pipe at the site. The tank shall be installed exactlt as per the manufacturer\"s approved installation drawing. (v) Supply, installation, testing and commissioning of cubical type M.V panel of suitable size suitable for 415V, 3phase, 4wire 50Hz AC.Rate includes all plumbing and cabling material within batery limit 5 meter. (VI) Supply of teritary treatment plant with PSF filter, ACF filter, multi port valves 02 nos, filter feed pumps (1W+1S) and chlorine dosing system of 3 cum per hour.(Vii) Pressure sand filter capacity 3 cum/hr, MOC : FRP, Make Pentair or any approved make, Filter media : Pebbles and Filtering sand, piping : PVC-1 No(Viii) Activated Carbon filter capacity : 3 cum/hr, MOC : FRP, Make : Pentair or any approved make, filter media : Activated carbon 900 I/V : Piping : PVC-1No(ix) Filter Feed Pump : Make Lubi/Kirloskar, Capacity 1 hp, Type non clog Submersible (1W+1S)(x) Chlorine (Sodium Hypo chlorite Dosing) system of 0-6 LPH pump with dosing drum HDPE Drum 50 litre Capacity. Pump Make : E-Dose / Asia/ LMI EquiTreated sewage water should fulfill the following criteriaPH value 6.5-8.5, BOD <10mg/litCOD <100mg/Lit, TSS<20mg/Lit, FOG <5mg/Lit, Total Nitrogen < 10mg/lit |
| 3 | FRP BASED UNDERGROUND PACKAGED SEWAGE TREATMENT PLANT OF CAPACITY 350KLD WITH IMT/TWST 20KL(P) and TTP 3.0 CumSupply, installation and commissioning of underground packaged sewage treatment plant (Capacity-350KLD) of MBBR Technology havingi) Chop whoop winding process based FRP package STP tank inclusive of all four zones a) Solid separation zone Tank No -1, 2, 3 of size each 10480mm (L) x 2430mm (D)b) Anoxic zone Tank No-4 and 5 of size each 6740mm (L) x 2430 mm (D) c) MBBR Aeration zone Tank No-6, 7, 8 of size each 10480mm (L) x 2430mm (D)d) Final Sedimentation zone Tank No-9 & 10 of size each 5520mm (L) x 2430mm (D)(iii) Submersible Raw sewage Transfer pumps (Cutter Type) -1 Working + 1 stand by for sump, Treated water transfer pump (1 working + 1 Stand By), One number sludge recirculation pump (submerisible), Twin lobe air blowers, PVC return sludge pipe 50mm dia, PVC inlet and out let pipe of 150mm dia, pvc interconnection pipes of 150mm dia, FRP straps, Turn buckle wire rope, concrete deadman, and eye bolts per the diameter and length of the tank, manhole cover as per the requirement, pvc air vent nozzle of dia 50mm, etc. Complete in all respect for running the plant successfully. (iv) Scope of work includes installation of 350KLD FRP tank along with FRP intermediate cum treated water storage tank of 20KL capacity with partition as per drawing and size of the tank along with electro mechanical items. The tank should be laid at an adequate depth below the sewage pipe at the site. The tank shall be installed exactlt as per the manufacturer\"s approved installation drawing. (v) Supply, installation, testing and commissioning of cubical type M.V panel of suitable size suitable for 415V, 3phase, 4wire 50Hz AC.Rate includes all plumbing and cabling material within batery limit 5 meter. (VI) Supply of teritary treatment plant (20 cum) with PSF filter, ACF filter, multi port valves 02 nos, filter feed pumps (1W+1S) and chlorine dosing system.(Vii) Pressure sand filter capacity 20 cum/hr, MOC : FRP, Make Pentair or any approved make, Filter media : Pebbles and Filtering sand, piping : PVC-1 No(Viii) Activated Carbon filter capacity : 20 cum/hr, MOC : FRP, Make : Pentair or any approved make, filter media : Activated carbon 900 I/V : Piping : PVC-1No(ix) Filter Feed Pump : Make Lubi/Kirloskar, Capacity 3-5.0hp hp, Type non clog Submersible (1W+1S)(x) Chlorine (Sodium Hypo chlorite Dosing) system of 0-10 LPH pump with dosing drum HDPE Drum 50 litre Capacity. Pump Make : E-Dose / Asia/ LMI Equi |
| 4 | Excavating over areas, in soft and loose soil n exc 1.5m in depth;and getting out including removing excavated material n exc 50m & depositing where directed. |
| 5 | Excavating over areas, in hard and dense soilexc 1.5m in depth upto 4.5mt depth and getting out including removing excavated material n exc 50m & depositing where directed. |
| 6 | Providing and back filling of aggregate / pebbles of size between 6-14mm in the excavated pit after tank installation inside the pit |
| 7 | Casting RCC M-20 using 20mm graded aggregate for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete |
| 8 | Supplying & making Formwork of plywood, timber with steel sheet lining or steel plate stiffened with steel angles, steel pipe scaffolding (telescopic or otherwise), to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter. M&L |
| 9 | Supplying , cutting to required size, fitting Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. Grade Fe 410 -W (Gde-E- 250) quality A. M&L |
| 10 | Supplying & fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. M&L |
| 11 | Casting Cement concrete in foundations, filling and mass concrete. Typr B2, 1:2:4, 40mm graded aggregate. M&L |
| 12 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips M&L |
| 13 | Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binder cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips M&L |
| 14 | Supplying & Laying Bricks, sub class B, laid flat, in floors, old size bricks. M&L |
| 15 | Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6mmean radius built in cement mortar 1:6 M&L |
| 16 | Rendering 12mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:3 .Additional thickness is provided as floating/setting coat→ M&L |
| 17 | Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete. M&L |
| 18 | Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165. M&L |
| 19 | Supplying and mixing liquid water proofing compound with the RCC or plastering work. |
| 20 | Suplying & aplying two coatsynthetic enamel paint over a coat of red oxide primer on steel surfaces after preparation of new surface. M&L |