| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.Complete all as specified and as directed. |
| 2 | M & L for point wiring using approved colour coding as per IS by using FRLS PVC insulated 1.5 Sqmm multistranded,1100 volt grade copper conductor cable unsheathed type, alongwith 1.5 Sqmm FRLS PVC insulatedstranded copper conductor cable for continous earthing in & incl PVC casing & caping with accessories having ISI mark fixed on wall surfaces / ceilingincluding concealed of suitable sunken box and hylum sheet for fixing switches, sockets, regularors, etc. for one light/fan/bell point controlled by one switch complete all as specified and directed. |
| 3 | All as per item No 2 here-in-before but for one multipin socket outlet 5 Amp onthe independent board |
| 4 | All as per item No 2 here-in-before but for one multipin socket outlet 5 Amp on the same board with other switches |
| 5 | All as per item No 2 here-in-before but for one multipin socket outlet 15 Amp on independent board with copper wire 2.5 sqmm |
| 6 | S & F switch piano type 5 Amp, 230 Volt, flush type single pole one waycomplete all as specified and directed. |
| 7 | S & F socket outlet multipin 5 Amp 230 Volt flush typecomplete all as specified and directed. |
| 8 | S & F switch piano type 15 Amp, 230 Volt, flush type single pole one waycomplete all as specified and directed. |
| 9 | S & F socket outlet multi pin 15 Amp 230 Volt flush type complete all as specified and directed. |
| 10 | S & F stepped type electronic fan regulator flush type, complete all as specifiedand directed |
| 11 | M & L Ceiling rose, 3 terminal, PVC isolated body complete all as specified and directed |
| 12 | M & LforLamp holder, PVC/Polycarbonate type with back plate suitable for Angle/batten fittings complete all as specified and directed |
| 13 | S & F Bell push flush type 5/6 Ampscomplete all as specified and directed |
| 14 | S & F Buzzer ding dong type AC 230 volt complete all as specified and directed. |
| 15 | S & F LED light fitting 20W, 220 volt AC, having colour temperature daylight (6500K), Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, complete all as specified and directed. |
| 16 | All as per item No 15 here-in-before but 10 watt (2ft) |
| 17 | S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.Complete all as specified and as directed. |
| 18 | S & F in replacement ofsheet metal enclosure double door distribution board single pole and neutral, 8 way 240 volt with 200 amps rated bus bar complete with bus and neutral linkcomplete all as specified and directed. |
| 19 | All as per item No 18 here-in-before but 4 way |
| 20 | S & F MCB 6 to 32 amp rating 240V, 10KA \"C\" curve, Single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 21 | All as per item No 20 here-in-before but of SPN and capacity 32 Amps |
| 22 | All as per item No 20 here in before but of SPN and capacity 40 Amps |
| 23 | M & L in replacement Sheet metalenclosure with Single pole and neutral enclosure with a two pin and earth plug and socket complete with one two pole MCB 20 Amp, 10 KA complete all as specified and directed. |
| 24 | M & L in replacement of submain wiring with PVC FRLS insulated single core multistranded copper conductor cable 1100 Volts grade 6 Sqmm wire, 3 runs (Phase, Neutral & Earth) all drawn through & incl PVC casing and capping of suitable size medium grade complete all as specified and directed. |
| 25 | All as per item No 24 here in before but of 4 sqmm size |
| 26 | M & L in replacement of Earthing complete with galvanised steel earth plate electrode 600×600×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mmdia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as directed. |
| 27 | S & F in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC, having colour temperature daylight (6500K), Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong/Grid ceiling complete all as specified and directed |
| 28 | S & F in replacement square/round recess mounted type compact downlighter in polycarbonate housing with high brightness LED chips, 10 watt 220 volts AC having colour temperature daylight (6500K), complete all as specified and directed. |
| 29 | S & F in replacement square/round recess mounted type compact downlighter in polycarbonate housing with high brightness LED chips, 15 watt 220 volts AC having colour temperature daylight (6500K), complete all as specified and directed. |
| 30 | S & F in replacement of constant current led driver model suitable for upto 25 watt LED Light fitting any type and modelcomplete all as specified and directed. |
| 31 | S & F in replacement of constant current led driver model suitable for upto 36 watt LED Light fitting any type and modelcomplete all as specified and directed. |
| 32 | S & F in replacement of Energy saving, environment friendly & robust Mediumbay /Highbay LED luminaire 120 watt with high efficacy (150 lm/W) with toughened glass complete all as specified and directed. |
| 33 | S & F in replacement of Modular switch 1 way 6 Amp, 1 module any type and model suitable for existing one complete all as specified and directed. |
| 34 | S & F in replacement of Modular socket 6 Amp, 2&3 pin combined, 2 module any type and model suitable for existing one complete all as specified and directed. |
| 35 | S & F in replacement of Modular switch 1 way 16 Amp, 1 module any type and model suitable for existing one complete all as specified and directed. |
| 36 | S & F in replacement of Modular socket 16Amp, 2&3 pin combined, 2 module any type and model suitable for existing one complete all as specified and directed. |
| 37 | S & F in replacement of Modular fan regulator, 120W-2 module any type and model suitable for existing one complete all as specified and directed. |
| 38 | S & F in replacement of modular white cover plate with frame 8 module any type and model as per existing one complete all as specified and directed |
| 39 | S & F in replacement of modular white cover plate with frame 6 module any type and model as per existing one complete all as specified and directed |
| 40 | S & F in replacement of modular white cover plate with frame 4 module any type and model as per existing one complete all as specified and directed |
| 41 | S & F in repair laminated hylum sheet cover of size 11 X 13 inches, ISI marked, cut with grooves for mounting of switches, sockets, regulators, etc including fixing in location as directed by Engineer-in-Charge. |
| 42 | All as per Item No 42 above but size 9 X 11 inches |
| 43 | All as per Item No above but size 9 X 6 inches |
| 44 | All as per Item No above but size 5 X 5 inches |
| 45 | S & F in replacement of LED flame proof light fitting 1 X 16 watt, CMRI certifiedrecommended for gas/vapour group of IIA & IIIB, zone 1 & 2 amd IP 65 protection with die cast aluminium housing with heat resistant toughened glass complete all as specified and directed |
| 46 | M & L foropening the fan motor of ceiling fan 1200/1400 mm sweep,dismantling old burnt winding and rewinding with super enameled copper winding wire of appropriate size incl varnishing and drying and assembling complete with replacement of unsv bearings, bush, capacitor, canopy, etc and making electric connections complete all as specified and directed.Note :(i)Old recovered U/S winding wire will be the property of the contractor. (ii)Replacement of defective parts will be measured and paid separately under respective item as supply only, Painting shall be measured and paid separately. |
| 47 | Supply only Bearing any type and model suitable to existing ceiling fan |
| 48 | Supply only capacitor 2.5 Mfd |
| 49 | Supply only Canopy (Up & down) suitable for Ceiling fan 1200/1400 mm |
| 50 | M & L foropening the fan motor of exhaust fan 250/300 mm sweep,dismantling old burnt winding and rewinding with super enameled copper winding wire of appropriate size incl varnishing and drying and assembling complete with replacement of unsv bearings, capacitor, etc and making electric connections complete all as specified and directed.Note : (i)Old recovered U/S winding wire will be the property of the contractor. (ii)Replacement of defective parts will be measured and paid separately under respective item as supply only, Painting shall be measured and paid separately. |
| 51 | Supply only Bearing any type and model suitable to existing exhaust fan 250/300 mm |
| 52 | M & L foropening the fan motor of exhaust fan 380/450 mm sweep,dismantling old burnt winding and rewinding with super enameled copper winding wire of appropriate size incl varnishing and drying and assembling complete with replacement of unsv bearings, capacitor, etc and making electric connections complete all as specified and directed.Note : (i)Old recovered U/S winding wire will be the property of the contractor.(ii)Replacement of defective parts will be measured and paid separately under respective item as supply only, Painting shall be measured and paid separately. |
| 53 | Supply only Bearing any type and model suitable to existing exhaust fan 380/450 mm |
| 54 | Supply only capacitor 4.0 Mfd |
| 55 | M & L foropening the fan motor of Pedestal/wall mounted/air circulator fan 400/450 mm sweep,dismantling old burnt winding and rewinding with super enameled copper winding wire of appropriate size incl varnishing and drying and assembling complete with replacement of unsv bearings, capacitor, etc and making electric connections complete all as specified and directed.Note : (i)Old recovered U/S winding wire will be the property of the contractor. (ii)Replacement of defective parts will be measured and paid separately under respective item as supply only, Painting shall be measured and paid separately. |
| 56 | Supply only Bearing any type and model suitable to existing Pedestal/wall mounted/air circulator fan 400/450 mm |
| 57 | Supply only capacitor 4.0 Mfd |
| 58 | M & L foropening the fan motor of Industrial air circulator/flame proof exhasut fan 400/450 mm sweep,dismantling old burnt winding and rewinding with super enameled copper winding wire of appropriate size incl varnishing and drying and assembling complete with replacement of unsv bearings, bush, capacitor, etc and making electric connections complete all as specified and directed.Note : (i)Old recovered U/S winding wire will be the property of the contractor. (ii)Replacement of defective parts will be measured and paid separately under respective item as supply only, Painting shall be measured and paid separately. |
| 59 | Supply only Bearing any type and model suitable to existing Industrial air circulator/flame proof exhasut fan 400/450 mm sweep.Complete all as specified and as directed. |
| 60 | Supply only capacitor 4.0 Mfd |
| 61 | M&L for painting of ceiling fans/exhasut fans/pedestal fans/complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust complete all as specified and directed by Engr-in-Charge |