|
| 1 | S & F in replacement of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified and directed |
| 2 | S & F in replacement of constant current led driver suitable for 8 to 25 watt LED bollard/post of lantern light complete all as specified and directed. |
| 3 | S & F in replacement of constant current led driver suitable for 45 to 60 watt LED street light complete all as specified and directed. |
| 4 | S & F in replacement of constant current led driver suitable for 70 to 100 watt LED street/flood light complete all as specified and directed. |
| 5 | S & F in replacement of LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection,pressure die-cast aluminium housing with PC doffused lens enclosure over LED for glare free lightcomplete all as specified and directed. |
| 6 | All as per ser item No 6 here in before but of 200 watt |
| 7 | S & F in replacement ofLED bollard fitting 8 watt 230 volts AC outdoor type suitable for ground mountedcomplete all as specified and directed |
| 8 | S & F in replacement of post top lantern LED type 20watt 230 watt volts AC outdoor type with decorativepost top for 360 degree indirect light IP 65 protectionwith impact and corrosion resistant complete with driver and lamp.complete all as specified and directed |
| 9 | All as per ser item No 8 here in before but of 40 watt |
| 10 | Supply , Laying , testing and commissioning in replacementXLPE insulated and PVC Sheathed, galvanized steel strip or wire armoured, heavy duty electric cable with multi stranded aluminium conductor, 1100 volts grade of size 16 sqmm 4 core complete all as specified & directed . |
| 11 | All as per ser item No 10 here in before but of 10 Sqmm 4 core |
| 12 | All as per ser item No 10 here in before but of 10 Sqmm 2 core |
| 13 | Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed. |
| 14 | Returning filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified and as directed. |
| 15 | Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point complete all as specified and as directed. |
| 16 | Supply and laying sand in trenches for protection of cable, sand cushioning to cable 8 cm thick below cable and 15 cm thick above cable in layers complete all as specified and as directed. |
| 17 | Supply and lay fly ash bricks best quality, laid in trenches, perpendicular to UG cable for cable protectioncomplete all as specified and directed |
| 18 | S & F in replacement ofGI pipe light grade galvanizedwith all fittings laid in trenches for cable protection of 50 mm bore all as specified and directed |
| 19 | S & F in replacement ofHDPE pipe of pressure rating 6kg/sqcm completewith all fittings laid in trenches/under roads, fixed to poles/walls as in cable protection of 50 mm bore complete all as specified and directed |
| 20 | M&L PCC 1:3:6type C2 (using 40mm graded aggregate crushed stone aggregate) as in pole foundation, filling and mass concrete complete all as specified and directed. |
| 21 | M&L Plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in pedestal / coping of pole and in Road cuttings including form work If necessary .complete all as specified and directed |
| 22 | M&L aluminium paintingto steel tubular street light pole for 5.5 mtr from top towards bottomand next 0.45 mtr Navy Blue and next 1.10 mtr white and 0.45 mtr Synthetic enameld paint yellow & black colour(Tiger cross) on Coping and writing pole No with white paint inside of black circle above the Navy blue painting and aluminium painting to GI bracket / pipe etc.and sticking of reflector stricker red in colour on the Poles at the height of 1.5metre above the copping complete all as specified and directed. |
| 23 | S & F in replacement of solar street light fitting 12 watt having high efficiency Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar Charge Controller and Aluminium Extruded body & specially programmed to automatically control the dimming and brightness of light, which increases the backup time, etc complete all as specified and directed |
| 24 | All as per ser item No 23 here in before but of16 watt capacity |
| 25 | All as per ser item No 23 here in before but of20 watt capacity |
| 26 | S & F in replacement of kiosk pole box made out of Engineering plastic comprising 60Amps, 4 pole aluminium strips, mounted on DMC insulator, size 250 x 200 x 100mm complete all as specified and directed |
| 27 | S&F in replacement ofstreet light bracket made outof GI pipe light grade 40mm bore bent to shape as required at site for street light fitting 1.2 m in length and fixed on wall/pole including necessary MS clamps made out of ms flat 40x6 mm- 02 sets, nuts, bolts etc complete all as specified and directed. |
| 28 | M & L in replacement sub main wiring with three single core 1.5 sqmm multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade drawn into and including non-metalic rigid PVC conduit 20mm dia including accessories fixed on poles with proper bracings complete all as specified and directed. |
| 29 | Replacement of unserviceable wire/cable from junction box to light fitting fixed on pole on existing PVC conduit by PVC insulated unsheathed copper conductor FRLS of 1.5 sqmm 3 runs. complete all as specified and directed |
| 30 | Supply and errection in replacement of steel tubular swaged pole 8.5 M long type 410-SP-22 complete with CI base plate, finial taper plug, bolts, nuts and screws etc includingcomplete all as specified and directedNote : Necessary excavation and earth work, PCC foundation, coping, disposal of surplus soil, Painting inside with black bitumen paint and out side shall be measured and paid separately on relevant items of Sch \"A\" |
| 31 | M&L boring of horizontal hole under road, pavement, hardstanding suitable for passing through upto 50mm bore complete all specified and directed. |
| 32 | S&F replacement, three pole power contactor confirming to IS/IEC 60947-4-1, type MNX 40 rating, 40 ampscomplete all specified and directed. |
| 33 | S&F replacement, multifunction digital timer switch (5-40) Amps, 240 volts, AC, single phasecomplete all specified and directed. |
| 34 | S&F in replacement of out door street light timer panles, three phase, maximum load 12 kw, prewired with digital timer switch, contactor TP rating 65 Amp and MCB TPN rating 63 Amp complete all as specified and directed. |