| 1 | Attending Day to day external water supply complaints partaining to water supply received through telephone or in person or online or detailment at MES service centre located at NAMS area bylocating and rectification of fault from and including No water supply, opening of jammed valves/unions and removing of blockage in pipe line of size GI/PPPR/DI/CI 20 to 200 mm dia and carrying out repairs to the extent of of opening of jammed valves connections and removel of mud / stone depositionfor the rectification of defects and refixing of exisiting desmantled serviceable items completer all as specified and directed.Note(i) If complaint warrants replacement of material as catered in BOQ here-in-after shall be paid under relevent item and no measurement shall be done under this item. Rate of attending complaints shall be considered to be quoted in the respective item. (ii) Necessary tools for tradesman shall be provided by the contractor. (iii) Transportation for tradesman and normal stores required for complaints shall be arranged by the contractor. |
| 2 | (iv) Compalints shall be attended and rectified immediately on receipt of complaint round the clock. (v)Contractor or his rep will report to AGE E/M complaint cell at 9 o clock daily for collection of complaints. Complaint received will be done in the same day and after completion of complaint he will report to complaint cell to submit the complaint slip duly signed by the user.(vi) For non attending of complaint within above mentioned time a penalty of Rs 300 / per day / complaints will be leived on contractor. This penalty shall also applicable to all the items mentioned in BOQ here-in-After. |
| 3 | Supply and fixing in replacement ofGI steel tubing 80mm bore including replacement of unserviceable fittings like Tee, bend, nipple, union, plug and socket etc. laid in trench/ wall/ floor including necessary saddles and clamps ,complete all as specified and directed. |
| 4 | All as per srl Item No 2.00 above but 50 mm bore complete all as specified and directed. |
| 5 | All as per srl Item No 2.00 above but 40 mm bore complete all as specified and directed. |
| 6 | All as per srl Item No 2.00 above but 25 mm bore complete all as specified and directed. |
| 7 | All as per srl Item No 2.00 above but 20 mm bore complete all as specified and directed. |
| 8 | Supply & fix in replacement Ductile iron pipe spigot and socketed class K-7 ISI marked with internal cement mortar lining and external zinc and bitumen coated pipes 200 mm bore confirming to IS 8329 : 2000 with all required DI fittings i.eflanged or spigot socketed pipe such as tail piece connecting pieces bends tappers, tee pieces (Single or double branch) any type & angle/radious and straight connecting pieces suitable for 200mm dia pipe complete with push on rubber gasket joint complete all as specified and directed. |
| 9 | All as per srl Item No 7.00 above but 150 mm dia complete all as specified and directed. |
| 10 | All as per srl Item No 7.00 above but 100 mm dia complete all as specified and directed. |
| 11 | M and L for replacement of 3-layer PP-R pipe of 20 mm dia Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as pecified and directed. |
| 12 | M and L for replacement of 3-layer PP-R pipe of 50 mm dia Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as pecified and directed. |
| 13 | M and L for replacement of 3-layer PP-R pipe of 110 mm dia Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as pecified and directed. |
| 14 | Material and labourin replacement Run lead joint complete with spun yarn packing & filling properly of200 mm dia/borepipe including necessary earth work complete all as specified and directed. |
| 15 | All as per srl Item No 13.00 above but 150 mm dia/ bore complete all as specified and directed. |
| 16 | All as per srl Item No 13.00 above but 100 mm dia/ bore complete all as specified and directed. |
| 17 | Supply & fix in replacement Cast iron sluice valve, ISI Marked 200 mm bore flanged of class 1.6 PN having spindle made out of gun metal, operating wheel nuts, bolts, packing complete all as specified and directed. |
| 18 | All as per srl Item No 16.00 above but 150 mm dia/ bore complete all as specified and directed. |
| 19 | All as per srl Item No 16.00 above but 100 mm dia/ bore complete all as specified and directed. |
| 20 | All as per srl Item No 16.00 above but 80 mm dia/ bore complete all as specified and directed. |
| 21 | M&L in replacement Gun metal globe/gate valve (ISI Marked) with iron wheel head, screwed both ends for pipes or for unions for 50mm bore dia steel tubing complete all as specefied. |
| 22 | All as per srl Item No 20.00 above but 40 mm dia/ bore complete all as specified and directed. |
| 23 | All as per srl Item No 20.00 above but 25 mm dia/ bore complete all as specified and directed. |
| 24 | All as per srl Item No 20.00 above but 20 mm dia/ bore complete all as specified and directed. |
| 25 | M&L in replacement Air release valveof size 100mm bore with two air outlet conforming to IS 14845 and fixingto dectile Iron pipe complete all as specified and directed. |
| 26 | M & Lin replacement CI non return valve of bore 150 mm dia, ISI marked complete all as specified and dircted |
| 27 | M & Lin replacement CI non return valve of bore 100 mm dia, ISI marked complete all as specified and dircted |
| 28 | Testing of water sample from Govt Approved labrotory and submit the report for Chemical/Bio logical testing complete all as directed by Engr -in -charge. |
| 29 | M & L for painting with approved colour to existing MS/GI pipe (raising main delavery over flow and wash out) of size 150mm dia upto 30 mtr height over head tank with two coat of synthetic enamelled paint including scrapping out old paint all as directed. Note:- All T & P, 30 mtr staging mtrl and man power risk shall be contractor responsibility. |
| 30 | All as per ser Item No 28.00 above but pipe 80/100 mm dia/ bore complete all as specified and directed. |
| 31 | Material & labour for cleaning away all grass vegetation, scapling shrubs bushes under groth roots and trees upto zero level not exceding 30 cm grith and removing rubbish upto distance of 50 mtr out the periphery of area under cleaness complete with tractor complete all as specified and directed. |
| 32 | Material & labour taking out CI/MS/DI pipe flanged type 150 mm / 100 mm dia of rising main/delevery/over flow/wash out of OHT of height 30 mtr checking for leakage , repair the same by replacing rubber gasket, nutbolts and MS supporting clamps complete all as specified and sirected. |
| 33 | Material & labourin replacement Brick mesonry valve pit of size 120x120x120cm (internal size) with mild steel cover 6mm thick and angle iron frame of size 50 x 50mm x 6mm duly painted with two coats of synthetic enameled paint over a red oxide primer including locking arrangement, brick work and plastering all inner surfacesof pit and exposed portion of out side shall be done in cement motor (1:4) complete all as specified anddirected. |
| 34 | S & F Motor protection overload relay 52 Amp to 75 Amp, 3 phase, Selectable trip Class - 10 A, as per IS/IEC 60947-4-1 complete all as specified and directed. |
| 35 | Supply and fixing in replacement 3 pole power contactor 80 Amp, AC 3, coil voltage 220 Volt complete all as specified and directed. |
| 36 | Supply and fixing in replacement 3 Pole power contactor 50 Amp, AC 3, coil voltage 220 Volt complete all as specified and directed. |
| 37 | Supply and fixing in replacement 3 Pole power contactor 70 Amp, AC 3, coil voltage 220 Volt complete all as specified and directed. |
| 38 | Supply and fixing in replacement 3 Pole power contactor 95 Amp, AC 3, coil voltage 220 Voltcomplete all as specified and directed. |
| 39 | Supply and fixing in replacement single phase preventor 3 pole, 415 Volt complete all as specified and directed. |
| 40 | Supply and fixing in replacementoverload relay range 30 Amp to 50 Amp, 3 Phase, Selectable trip Class - 10 A, as per IS/IEC 60947-4-1 complete all as specified and directed. |
| 41 | Supply and fixing in replacementoverload relay range 70 Amp to 100 Amp , 3 Phase Selectable trip Class - 10 A, as per IS/IEC 60947-4-1 complete all as specified and directed. |
| 42 | Supply and fixing in replacement Star delta Timmer 0-30 Sec, Single phase digital 220 volt complete all as specified and directed. |
| 43 | Supply and fixing in replacement Star delta Timmer 0-30 Sec, Three phase digital 415 volt complete all as specified and directed. |
| 44 | Supply and fixing in replacementAdd on auxiliary contact block type 1NO + 1NC complete all as specified and directed. |
| 45 | Supplying and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 1100 voltsgrade cross sectional area 50 sq. mm 3.5 core complete all as specified and directed. |
| 46 | Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5m deep and getting out complete all as specified and directed. |
| 47 | Returning, filling in including spreading, leveling and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 48 | Removal of surplus soil to a distance not exceeding 50 metre away and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed. |
| 49 | Supply only OT soluation for chlorine test 500 ML bottle complete all as specified and directed. |
| 50 | Supply only anti vegetation chemical liquid of 1ltrs bottle complete all as specified and directed. |
| 51 | Material & labour in replacementfor chlorine test kit complete with all testing fitments and OT solutionall as specified and directed by Engr-in Charge |
| 52 | Supply and fixing of LED T-8 tube light fitting with sinle side connection LED tube rod 18/20 W, 4 Feet made of CRCA sheet steel box type including bipin holder and connection with PVC insulated twin core 23/0.0076 ywisted copper cable from ceiling rode to light fitting complete all as specified and directed. |
| 53 | Supply & fixLED Street Light Luminaire 25 watt 6000K with high power LED cool white, CRI 75, +/- 5% supply voltage 220/240/50 Hz, light engine driver base. pole adapter, powder coated pressure die cast aluminium with heat resistant toughened glass with lens complete all as specified and as directed. |
| 54 | Supply and fixing in replacement 1100 volts grade heavy duty cabel PVC insulated copperconductortwin core cable flat or circular size 1.5 Sqmm complete all as specified and directed |
| 55 | Supply and fixing in replacement copper thimble 16/25 sqmm complete all as specified and directed. |
| 56 | Supply and fix in replacement MCB 40 Amp TPN,415 Volts, 10 KA complete all as specified and directed.. |
| 57 | Supply and fix in repalcemnet of MCCB 100 Amp fixed thermal and fixed magnetic, 3 pole, 415 volt, 16 KA complete all as specified and directed. |
| 58 | All as per srl item No 56.00 above but capacity200 Ampfixed thermal and fixed magnetic, 3 pole, 415 volt, 36 KA complete all as specified and directed. |
| 59 | All as per srl item No 56.00 above but capacity250 Amp fixed thermal and fixed magnetic, 3 pole, 415 volt, 36 KA complete all as specified and directed. |
| 60 | Supply and fixing in replacement aviation light LED 2 x 20 Watt with electric connection from Pump house room to light complete all as specified and directed. Note : Cable 1.5 sqmm twin core paid under sch item srl No 53.00. |
| 61 | Cleaning of over head water storagetank of capacity 1 lakh gallon at 30.0 metre height, by dewatering complete water, cleaning of mud , sludge accumalated in the bottom/walls of both compartment of over head reservoir with bursh, applyingbleaching powder / potassium permagnate solution for making the reservoir/Tankhygienically safe for store of water, replacing the wire mesh of top ventilator ofover head water storagetank at 30 metre height & write the date of cleaning and the capacity of tank with white paint on black painted surface at ground levelcomplete all as specified and directed. |
| 62 | All as per ser item No 60.00 above buttank of capacity 50000 gallons complete all as specified and directed. |
| 63 | All as per ser item No 60.00 above buttank of capacity 25000 gallons complete all as specified and directed. |
| 64 | Earthing complete with galvanized GI earth plate electrode of size 600 x 600 x 6.00 mm ,buried directly in ground (earth pit not less than2.25 m below normal ground level) with top edge of earth Strip not less than 1.5 mtr below normal ground level, connected to galvanized earth strip 25 x 4mmby means of bolts ,nuts ,check nuts and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate no 3 of SSR part-I, 20 mm dia watering pipe medium grade 1.70 mtr long, GI protection pipe light grade 40 mm dia from earth pit to main board complete all as specified and directed. Note : Maximum length of GI protection pipe with each earth shall not exceed 7.5 mtrs including necessarypitwith cover. |