Tender For Construction Of Modern Slaughter House In Thiruthuraipoondi Municipality; 1 Installation of vertical bored cast in-situ Bored pile of 700mm diameter in all types of soil using Design Mix concrete of grade M30 with OPC cement, fine aggregate (M - Sand), 20mm and downgraded HBGS jelly coarse aggregate. The rate includes cost of boring to the required depth with Bentonite solution with Temporary casing of required length, conveyance of materials and pouring concrete including all tools and plants shifting the plants and equipments from one point to another. Excavation of mud pits for circulation of Bentonite solution, closing the mud pits to the original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the Departmental officers. To carry a safe working load not less than than specified, excluding the cost of steel reinforcement but including the Bentonite solution, machinary and labour charges etc.,all complete. 2 Pile 01 450mm Dia 3 Earthworkexcavationin all classes of Soils and Sub soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering , bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the Departmental officerswith an initial lead of 10mts and initial lift of 2mts and clearing and levelling the site etc, complete complying with standard specification. ( TNSS NO or NBC No 23,24, V,VI S2) 4 Plinth Beam 5 Supply delivery and filling ofM - Sand in layer of not more than 15 cm thick including watering with all layers and consolidation complying with standard specification including cost and conveyence ofM Sand to Site and all labour charges and all other incidential charges etc,. complete as per Standard Specification 6 Cement Concrete of mix 1 : 4 : 8 (One Cement four sand eight aggregates) using 40mm gauge hard broken including cost conveyance of all materials to site including formwork and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification. 7 Vibrated Plain Cement concrete in 1:2:4 (One part of cement,Two part of M sand Four part of ISS gauge HBG metal) using 40mm ISS gauge HBG metal including cost of conveyance of metal from approved quarry at site including cost of cement and all labour watering including mixing dumpling and laying in layer of not more than 15 cm thick and tampering to consolidation curing and all other incidental any complying with standard specification etc., as per TNDSS NO.28 V,VI S25 8 Supplying and filling of well gravel by lorry in basement filling including conveyance loading and unloading charges and all other incidential charges filling laying watering and consolidation etc., complete as directed by the Dept., Officers with standard specification 9 Supplying ,errecting and CenteringforSideandSoffiotsincludingnecessarysupports for plane surfaces in all floors with all cross bracings using mild steel sheets of size 90x60cm & 10 gauge stiffened, welded with steel angle of size 25x25x3mm for boarding laid over silver oak joists (Country wood) of size 10x6.5cm spaced @ about 90cm c/c and supported by casurina props of 10 -13cm dia.spaced @ 75cm c/c etc., complete complying with standard specifications for Pavement Drain etc., Complete. 10 Without Strutting 11 Plane Surface 12 Column 13 Supplying and Fabrication of Steel and placing in position MS / Ribbed tor steel grills for RCC works as per design given including cost of steel and GI binding wire in Floors etc., Complete complying with standard specification in force per Kilogram. 14 Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - 15 Providing and laying in position Standardised Concrete Mix M-25 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 350Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards 16 Upto Basement 17 Ground Floor 18 Reinforced Cement Concrete.1 : 8 : 16 (One part ofCement, Eightpart of sand and Sixteen part ofaggregates) using 20mm gauge hard Granite broken stone jellyincluding cost ofcuring, etc., complete as per standard specification and as directed by Engineer incharge. 19 Brickworkincementmortor1 : 5(One Cement and five Sand)usingbest quality of countrybricksof size 83/4x41/4x23/4 includingall costof materialsand Labour Charges including Curing charges etc., Complete as per standard specification. 20 Below Ground Level 21 Ground Floor upto 4.50mt 22 SpecialCeiling PlasteringinCement Morter M. 1 : 3 ( One cement, three sand) to10 mmthickincludingallcostandconveyance ofallmaterialstositeincludingcostofcementwhichwillbepurcharedlocallybythe contractor andconveyanceofthesametotheactualworksiteandcostformworkincludingwatering curingandallleadsofgoodpotablewaterandallother. 23 WeatheringCoarsewith concrete broken brick jelly concrete on 20mm. Gauge in pure slaked shell lime (no sand to be used) over roof slab be proportion of brick jelly to being 32 : 12.5,Well beaten with wooden beaters giving the required shape and thickness as directed by the Departmental Officers. 24 Finishing theTopwithOne Course of MachinePressed Tilesof Size200 x 200 x20 mmofApprovedqualitylaidincementmortor 1 : 3(One part of cement and threepart ofsand) mixedwithwaterProofCompounds 2% by weight of cement used and the top pointed with the same mortar etc., complete. 25 Supply and fixing of Polished Rajasthan kota stones 20mm thick with machine ctting edges forFlooring inculding laying Vibrating, curing and finishing bearing surface at the sides and bottom of the slan, beams of shall be finished smooth with cm 1:3 and craft paper laid without claiming extra cost complete complying with standard specification and as directed by the departmental officers 26 Paving the floor with descrgned coloured vitrified tiles of size 600 x 600 x 8mm of best quality and approved variety complying / confirming ISI specification land over cement mortar 1:3 (one cement and three M- Sand) 20mm thick and pomted with same coloured cement neatly etc., complete. 27 PlasteringinCement Mortar 1 : 5 (one cement and five sand) to12 mmthickincludingallcostandconveyanceofallmaterials tositeincludingcostofcementwhichwillbepurcharedlocallybythecontractor and conveyanceofthesametotheactualworksiteandcostformworkincludingwatering curingandallleadsofgoodpotablewaterandallother. 28 Painting thewalls with Two Coatsweather Proof Exteriour Emulsionbased emulsion Paint over one coat ofprimer as instructed by the departmrntal officers includingPreparation of surface curing, etc complete in all floorscomplying with standard specification. ( The Colour and shade of the paint shall be got approved by the departmental officers.) 29 SupplyandFixingofStailess Steel Doors with frame ( Box section using Stailess Steel frame of 1.6mm thick ), of size 100mm x 60mm with a rebate of 30 /35mm x15mm on one side of the frame including supplying and fixing dovetil splayed Stailess Steel hold fast, costofmaterialandLabourincludingallincidentalchargesetc.,completecomplyingwithstandardSpecifications. 30 SupplyandFixingofStailess Steel Doors shutter with frame ( Box section using Stailess Steel frame of 1.6mm thick ), including supplying and fixing locking arrange ments, Ventilating arrangements, costofmaterialandLabourincludingallincidentalchargesetc.,completecomplyingwithstandardSpecifications. 31 Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 25GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with spag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown olour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the executive Engineer before use on work 32 SupplyingandFixingofPush and Pull type RollingShutter confirming to IS 6248/1979 and as amended from time to time. With ISI make of approved size and section using 18 gauge G.I.sheet. The Shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc., and as directed by Engineer incharge. 33 Supplying and fixing in position of Iron grills of required size using 32 x 32 x 6mm angle around and 2 Nos of vertical at center with b flats diagonally to the existing open space for grills into necessary hold fast conveyance and one coat of primer etc., complete for Windows and others. 34 Painting the new iron works such as steel doors, Windows,Ventilators windows bars,balustrades etc,in all floor withtwo coats of best approved first quality and colour of synthetic enamel paint of approved quality, colour and brand (to be approved by executive engineer before use on works ) over one the existing red oxide priming coat in all floors excluding cost of priming coat etc,complete complying with Standard Specification. ( The Make, Quality and colour of paint should be got approved bythe engineer in charge before use on works )( TNSS NO or NBC No 61 V VI (54) 3) 35 Dadooing sides of walls with Glazed design tiles of size 150 x 150 x 6mm set in Cement Mortar 1:3 ( One cement, three sand) 20mm thick and pointed with the same colour cement including cost and conveyance of all materials, labour charges complete as per standard specification. 36 SupplyingandFixingin position best approvedof BIS quality110mmP.V.C RainWaterdownfallpipe having a pressure of 4Kg / Sq.cm including cost of necessary PVC shoe,PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails etc, and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc, complete. The rate shall be inclusive of cast of removable cast iron grating. The PVc pipe shall be fixed in wall with special type of Uclamp at the centre of the pipe line in addition to those for more than 3.00mt pipe length etc,CompleteComplyingwithStandardSpecifications. 37 Providing and laying, spreading and compacting graded stone aggregates to Wet Mix Macadam 250mm thick specification including premixing the materials with water at OMC in mechnanical mix plant carriage of mixed material by tipper to site laying in uniform layers with pavers in Sub Base/ Base course on well prepared surface and compacting with vibratory roller to acheive the desired density including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc.,complete as per clause 406 of MORTH 38 Supplying and laying Rubber Moulded Hydraulic Pressed Paver Block 83mmM40 grade Providing and laying high strength type conforming IS 15658-2007 Of rubberized interlocking paver lock in size of minimum compressive strength of 40N mm2 in uniform shape of approved make to be laid in flurring bone pattern with sand cushion below the uniform shap of approvednon skitting surface in the top and the rate including levelling the base preparation ofpavers as sub base, sand cushion 100mm thick layingout of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,. 39 Wiring with 2x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor cable of 1100V grade insuitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with MS switch Box and 5AFT switch with painting of suitable colour continuous earthwire connection of 1.5 sq.mm copper wire for lightpoint/fan point(for electronic regulator) 40 Wiring with 2 x 1.5 sq.mm (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with 150 x 100 x 113mm TW switch box for 5A 3 pin non inter locking Wall socket with 5A flush type switch with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC plug point 41 Supply and fixing of single box type 440W fluorescent fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed FRLS copper leads from terminals to the fitting 42 4 way / 8 way / 12 way vertical SPMCB sheet steel distribution boards flush type / surface type fitted with bus bars and neutral links with single phase MCB outgoings and separate 2 way provision for accommodating One No. 2 pole incoming MCB / Isolator and another separate 2 way provision for accommodating One No. 2 pole ELCB / RCD with label holder and provisions for taking up cable for size not less than 35sq.mm. 43 Supply and fixing of 65mm (2-1/2) GI pipe (Class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable MS box to house 5A control switch 16A fuse unit (500V) etc with suitable angle iron frame work with door and with lock and key arrangements and with supply and fixing of 440W twin street light fluorescent fitting with copper chokes and condenser with fluorescent tubes with 1 metre of 32mm dia GI pipe (Class B) complete with necessary clamps on the above post with PVC unsheathed leads with painting of suitable colour 44 supply and fixing of 30W LED street light fitting with LED (Higher end) with 25 mm dia. GI pipe (class B) with 1 no. 25 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting 45 3.5 x 180 sq.mm LTUG 46 Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT 47 Supply and Fixing of TNEB meter Board suitable for 32A Single Phase Service connection with 32A Fuse unit (500V) 32A neutral link and earth link (1 x 1/8 Copper Flat) on TW Plank of Size 375mm x 300mm x 19mm with Supporting TW Reepers of 1 thick an either side with Painting with Suitable bolt and nuts for fixing the TW Plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB Meter to Fuse Unit (SD No :125) 48 Supply and Fixing of CCTV Camera with Specification of Dahua- HAC-HFW 1100DP-B-0600 720P 1 Mega Pixel AnalogHigh Definition camera, outdoor-25/30 fps@720P,1/2.9 1 Megapixel CMOS, 50m IR,ICR, 6mm Lens optional, IR Bullet Dahua - Channel - AHD, High Video Quality on HD 1080N, Transmit Video Signal, audio signal & Dual way data communication signal over one coaxial cable, HD Video transmission without Video quality loss & delay, extremely, long transmission distance (300), as directed by Departmental Executive Engineer. 49 Supply and Installing sony CCTV (Q) 50 29 Led TV for display (Q) 51 Poe suitable for CCTV IP camera 24 port 52 Rack With Accesssories - 12U Rack 53 Armoured LAN & CCTV Cable Cat 6 54 Hard Disk For NVR (8TB) 55 Network Video Recorder for CCTV 16 Channel 56 Conducting Geophysical survey to find out the water table including cost for convey the instrument to the site and other charges 57 Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another within Tamilnadu in alluvial soil sedimentary strata of clay and sandstone shale pebbles boulders etc . By first taking a pilot bore of 140mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel ,labour and drilling bentonite and waterrequired for drilling at site (site will be shown by the concerned officers) including construction of mud pit 58 Upto 60 m Depth ending below ground level 59 0.00 to 60.00 M 60 Supply of unplasticied PVC ribbed screen casing pipe and plain casing for borewells in 3M length screened and threated socket ends with couplers as per IS 12828/89 to suit deep borewells. 61 150 mm casing Pipe For Upto 40m depth pipe assembly (with slot). 62 160mm dia end cap Bore Well Cover. 63 MS 32/40mm MS clamp set 64 Supply of Gunmetal non return valve 2.0 dia. (ISI) 65 Nylon Rope for borewell 66 Labour Charges for inserting 150 mm/200mm/250 mm dia (M.S. Casing pipes assembly with slots or with out slots) in the drilled hole including welding the joints etc., complete and supplying and packing the annular space with pebbles of size and quality as approved by the Executive Engineers of TWAD Board. 67 e) Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including transportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yield test by ‘V’ notch method. 68 Supply and delivery of clear water vertical wet type submersible pump conforming to IS 8034/2002 and as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continuos rated two pole suitable wet type vertical squirrel cage induction motor suitable for operation in AC single phase 230 V+/- 10 %,50 HZ +/-5 % 20x50lpm 69 Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/single Phase/50HZ(± 5%) and 230 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately). 70 Labour charges for the erection of submersible pumpset in borewell / openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilotindicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. 71 HDPE PIPES PN 875mm AS PER IS 4984/2016(Pre-Compounded Resin) 72 Supply and delivery of PVC insulated and sheathed three core 2.5 Sq.mm Flat type copper cable conforming to IS 694/1990. Complete. 73 Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coatincluding the cost all materials etc.,complete, in all floors. 74 Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification.