| 1 | fo|qr uxjh; forj.k [k.M&\"k\"Ve] xkft;kckn ds dk;Z{ks= esa fctusl Iyku 2024&25 ¼ikVZ&2½ en esa 33 ds0oh0 ykbZu dk lqn`<+hdj.k ,oa vkj0,e0;w0 yxkus vkfn ds dk;Z gsrqA |
| 2 | Carriage of Cable HT XLPE 11 kv 3x185 sqmm from Store center to work site loading and unloading both side. |
| 3 | Carriage of Cable HT XLPE 33 kv 3x300 sqmm from Store center to work site loading and unloading both side. |
| 4 | Carriage of ST Pole 13 Mtr from Store center to work site loading and unloading both side. |
| 5 | Carriage of PCC Pole 11 Mtr from Store center to work site loading and unloading both side. |
| 6 | Carriage of ACSR Dog Conductor from Store center to work site loading and unloading both side. |
| 7 | Carriage of 33 kv composite Polymeric Pin Insulator from Store center to work site loading and unloading both side. |
| 8 | Dismantling of ACSR Scrap and Safely carriage from work site to Store center/JE store loading and unloading both side. |
| 9 | Dismantling of Iron Scrap and Safley carriage from work site to Store center/JE store loading and unloading both side. |
| 10 | Erection of ST pole 13 Mtr long at site complete in all respect as per RESPO norms. |
| 11 | Erection of PCC pole 11 Mtr long at site complete in all respect as per RESPO norms. |
| 12 | Providing Concreting of Pole at various site complete in all respect as per RESPO norms. |
| 13 | Laying of HT XLPE 33 kv 3x300 sqmm Cable with Trenchless Method without HDPE pipe at site complete in all respect as per RESPO norms. |
| 14 | Laying of HT XLPE 33 kv 3x300 sqmm Cable with Trenchless Method through providing HDPE pipe at site complete in all respect as per RESPO norms. |
| 15 | Laying of HT XLPE 33 kv 3x300 sqmm Cable loop and riser at site complete in all respect as per RESPO norms. |
| 16 | Laying, Lifting and sagging of ACSR Dog conductor at various site complete in all respect as per RESPO norms. |
| 17 | Laying of 11 kv XLPE 3x185 sqmm cable at site complete in all respect as per RESPO norms. |
| 18 | Fixing of 33 kv composite Polymeric Pin Insulator at various site complete in all respect as per RESPO norms. |
| 19 | Construction of plinth suitable for RMU at various site complete in all respect as per RESPO norms. |
| 20 | Supply & fixing of 12kv 630 Amps 21KA for 3 Sec. SF6 , BIL 28 KV/75 KV peak, extensible, outdoor duty 3-way, fully motorised and manually operated Ring Mains Unit originally manufactured by OEM in its factory only, comprising of 02 load break switch and 01 vaccum circuit breaker consisting of copper busbar in SF6 insulated tank with a provision electromechanical interlock to avoid accidental closure of earthing switch even when cable is in live condition. RMU should be Type Tested for Internal arc of 21 KA for 1 Sec with AFLR classification and gas to be from rear bottom of the switchgear away from the operator to ensure safety of the operating personnel. Suitable Ct 200-50/1 A with microprocessor based numerical over current relay (IDMTL + Inst.)for Protection to be provided with VCB Feeder with right angle boot for termination Kits. All the necessary wirings and Dummy panel/space for FRTU to be given along with RMU for future compatibility with SCADA system (Supply of FRTU is not in scope). Battery, Charger etc. for Motorised Operation of RMU to be provided. The scope is including Plinth/ Angle iron Stand as per OEM design complete in all respect as per the direction of Engineer incharge. Complete RMU and its accessories should be suitable for altitude of 100 mtrs above Sea Level. (Makes: ABB/Siemens/Eaton/Schneider or authorized by UPPCL). complete in all respect. |
| 21 | Providing of earth electrode for chemical earthing Pipe in pipe type proper hot dip Galvanization dia 50 mm length 3 mtr – 32mm x 6mm terminal connection hole dia 8mm The cavity between the pipe & Pipe is filled with conductive Mixture – for hermetically Filling inside the cavity i.e. between secondary conductor & Primary conductor, crystalline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc. The electrode should be sealed from both the ends. The outer pipe of the electrode should be galvanized the characteristics of this compound is highly conductive, nonmagnetic & noncorrosive in G.I. Including providing of backfill compound. Each electrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested for RMUs installed. |
| 22 | Providing and fabricating the Fencing of RMU at site complete in all respect as per respo norms. |
| 23 | Providing & fixing of Cable Box O/D 11 KV 3x185 XLPE at site complete in all respect as per respo norms. |
| 24 | Providing & fixing of Cable Box O/D 33 KV 3x300 sqmm at site complete in all respect as per respo norms. |
| 25 | Providing & fixing of Holding Clamp with Bolt & Nuts at site complete in all respect as per respo norms. |
| 26 | Providing & fixing of Nut & Bolt at site complete in all respect as per respo norms. |
| 27 | Providing & fixing of MS Channel 100x50 mm at site complete in all respect as per respo norms. |
| 28 | Providing & fixing of 33 KV disc Insulator at site complete in all respect as per respo norms. |
| 29 | Providing & fixing of Earth Rod at site complete in all respect as per respo norms. |
| 30 | Providing & fixing of 33 kv Cross Arm V Type at site complete in all respect as per respo norms. |
| 31 | Making of all HT/LT connections required to energize the line and restoring of electricity supply to consumer properly complete in all respect. |