Tender For Repair To Leakage/ Seepage, Roof Treatment And Connected Items In Certain Md And Otm Accn Under Age B/R-Ii At Nams, Amritsar-Punjab

Military Engineer Services has published Tender For Repair To Leakage/ Seepage, Roof Treatment And Connected Items In Certain Md And Otm Accn Under Age B/R-Ii At Nams. Submission Date for this Tender is 14-06-2025. Drainage Tenders in Amritsar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

49322257
Tender For Repair To Leakage/ Seepage, Roof Treatment And Connected Items In Certain Md And Otm Accn Under Age B/R-Ii At Nams
Tender
Indian
Punjab
Amritsar
14-06-2025

Tender Documents

Tender Details

Tender For Repair To Leakage/ Seepage, Roof Treatment And Connected Items In Certain Md And Otm Accn Under Age B/R-Ii At Nams; 1 Supplying, Hoisting and fixingin repairs 500 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top) & fixing arrangement for inlet/outlet/over flow and vent pipe of standard size including taking down old water storage tank all as specified in SSR Part-I including 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixedcomplete all as specified and directed. 2 Supplying, Hoisting and fixingin repairs 1000 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top) & fixing arrangement for inlet/outlet/over flow and vent pipe of standard size including taking down old water storage tank all as specified in SSR Part-I including 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixedcomplete all as specified and directed. 3 Disconnecting, setting aside (or lowering if required) andCleaning & removing all scale and dirt etc from HDPE water tanks of 1000 litres capacity (Tanks placed on top of roof)and from mouths of circulating pipes etc including washing the tank with bleaching powder and hoisting, reconnecting and re-fixing in position including writing the date of cleaning of tank with synthetic enamel (black/white) paint of size not less than 10cm of each letter complete, all as specified and directed. 4 Disconnecting, setting aside (or lowering if required) andCleaning & removing all scale and dirt etc from HDPE water tanks of 500 litres capacity (Tanks placed on top of roof)and from mouths of circulating pipes etc including washing the tank with bleaching powder and hoisting, reconnecting and re-fixing in position including writing the date of cleaning of tank with synthetic enamel (black/white) paint of size not less than 10cm of each letter complete, all as specified and directed. 5 Taking down cement plaster on brick/stone/concrete walls /ceiling incl racking out joints etc,hacking for key, scrubing down with water etc & dispose off debris upto a distance n exc.500 mtrs where directed complete all as specified and directed. 6 M&L for 15mm thick cement plaster in Cement motar1:4 on fair faces of brick or concrete workand finishing the surface even and fair(without using extra cement) incl WPC @3% weight of cementetc.complete all as specified and directed. Note: WPC will be measured and paid separately under appropriate items 7 M&L for 5 mm thick cement plaster in CM (1:3) onconcrete surfaces of ceilingand finishing the surface even and smooth (without using extra cement) etc complete all as specified and directed. 8 M&L for rendering 15mm thick in cement mortar (1:6) on other thanfair faces of brick work or concrete surfaces of walls , finished even and smooth without using extra cementcomplete all as specified and directed. 9 M&L for damproofing to wall with two componet Acrylic polymer cementitious water proofelastomeric coating food grademix to form uniform slurry and apply with paint brush as first coat then laying a layer of fibre glass mesh clothas first coat is still green with overlap of joits ofFibre mesh not be less than100mm , then finally apply second layer mixby brush to entire surface of container covering0.6-0.75sqm /kg at 1mm thickness in two coat depending on the level of substrate and curing it for minimum 3 days.Note : Quoted rate shall be deemed to be inclusive of materials all labours, tools and plants, scaffolding and working upto height 6 mtr etc. Adoption of necessary safety arrangements like safety belts ropes, helmets netting etc which are required for safety of worker working at height exceeding 6 mtr shall be mandatary and deemed to be inclusive in quoted rates. complete all as specified and directed. 10 M&L for applying wall care Zero, lime, flexible, water resistance anti fungal 1.5 mm thick two coats of oil bound distemperin new surface over a coat of alkali resitance primer to internal plaster surface complete all as specified and directed. 11 M&L for prepration of new plaster surfaces of wall and applying two coats of High penetration water resistance, anti bacterial NANO cement base paint over a coat of NANO alkaliwater resisitance primer complete all as spceified and direted . 12 M&L for preparation of newly plastered ceiling surfaces and applying three coats of white wash complete all as specified and directed. 13 Material and labour for plain cement concrete (1:5:10) type D-2 using 40 mm graded stone aggregate as in filling in sunken floors including demolition of cementin concrete (unreinforced)of any description and in any position in ground floor and pavings any thickness (below or above ground level) complete all as specified and directed. 14 Material and labour for Water proofing treatment to sunken floors of kitchen, toilets, laboratories, bath and WCs etc shall be as under :-(a) Application of Two component Acrylic modified cementitious coating(i) The surfaces to be applied shall be completely dry andfree from containments such as dirt, dust, oil, surface treatments and old coatings. Concrete substrates must be mechanically prepared using abrasive blast cleaning or milling to remove cement laitance, existing coatings and achieve a gripping profile that is clean, dry and free from laitance and any other form of surface contamination. The installation instructions in manufacturer’s published literature should be strictly complied with, including but not limited to the following :- (ii) Chipping out any visible cracks in “V-Groove” pattern as applicable. Special attention on this part. Cleaning of cracks & then filling those cracks with SIKA latex SBR 100 putty/ Dr Fixit 302 SBR latex / Perma latex SBR / FOSROC Nitabond SBR latex / Asian Paints latex as required. Final cleaning of surface with power grinder, wire brush, hair brush & vacuum pressure if required.(iii) Dampen all surfaces immediately ahead of application of Acrylic modified Cementitious coating of Sika Top Seal – 107 / Brush Bond FOSROC/ Dr Fixit/ STP/CICO. 15 (iv) Whilst the surface is still damp from saturation (S.S.D), apply one coat of Acrylic modified Cementitious coating of Sika Top Seal – 107 / Brush Bond FOSROC/ Dr Fixit/ STP/CICO of viscosity as per manufacturer’s instructions.(v) Apply Glass Fabric Sheet of Sika Fab 1 / FOSROC/ Dr Fixit/ STP whilst the first coat is wet.(vi) Once touch dry, apply second coat of Acrylic modified Cementitious coating of Sika Top Seal – 107 / Brush Bond FOSROC/ Dr Fixit/ STP/CICO of viscosity as per manufacturer’s instructions on the entire area.(vii) Second coat shall be applied after 6-8 Hrs of application of previous coat andin the direction right angle to the previous coat. (viii) The waterproofing coating should be taken to a height minimum 300 mm above the finished floor level on the vertical surface.(ix) It is essential to cure Acrylic modified Cementitious coating immediately after application (minimum 6-8 Hrs drying) for a minimum of 3 to 5 days to ensure full cement hydration and to minimize cracking.(x) A protection plaster (12-15mm thick) in CM 1:3 admixed with appropriate Integral water proofing compound has to be applied on the walls. 16 Admixture : Sika Plastocrete Plus / FOSROC / Dr Fixit / STP / CICO confirming to IS 2645.Providing and applying a protection screed of 50mm thick 1:4, cement sand mortar admixed with Sika Plastocrete over the applied water proofing coating on horizontalsurfaces.Admixture : Sika Plastocrete Plus / FOSROC / Dr Fixit / STP / CICO confirming toIS 2645(xi) All the corners and joints should be pre-treated with an elastic waterproofingsealing tape with a Woven bonding mesh on each surface and an elastic expansionszone in the centre of Make Sika Seal Tape S/FOSROC/Dr Fixit/STP.(xii) The membrane has to be protected in accordance with the manufacturer’srecommendations until placement of concrete. The membrane to be inspected fordamage just prior to concrete placement and make repairs in accordance withmanufacturer’s recommendations(xiii) Waterproofing treatment has to be carried out through applicators authorised 17 (b)All the joints of pipes and traps within the sunken portion shall be sealed properly by epoxy sealant. (c)Al CI traps in sunken slabs to be enclosed with PCC 1:1.5:3 (min 15cm) All-round. (d)The sunken portion shall be filled with PCC 1:5:10type E-2 (using 40mm stone aggregate) completeall as specified (e)Providing drainage spout pipe GI 40 mm dia bore light grade upto outside of outer wall (Approx 450 mm to 600 mm long) including cutting to existing wall and making good the disturbed surfacecomplete all as specified and directed.(f)Providing 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in flooring for laying floor finish all as specified. Note: Items No 14.03 (d), (e) & (f) shall be measured and paid separately. 18 S&F drainage spout pipe GI 40 mm dia bore light grade upto outside of outer wall (Approx 450 mm to 600 mm long) including cutting to existing wall and making good the disturbed surfacecomplete all as specified and directed. 19 M&L non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding0. 06 sqm but not exceeding 0.11 sqm, in floors etc. laid over 15mm thick screed bed in cement mortar 1:6 and jointed in neat cement slurry and pointed in white or coloured cement to match incl dismantling / demolition and rubbish off the primises etc complete all as specified and directed. 20 M&L non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0. 11 sqm but not exceeding 0.18 sqm, in floors etc. laid over 15mm thick screed bed in cement mortar 1:6 and jointed in neat cement slurry and pointed in white or coloured cement to match incl dismantling / demolition and rubbish off the primises etc complete all as specified and directed. 21 M&L for glazed ceramic coloured tiles of size 450mm x 300mm x 7mm thick verticale tiles with highlighter any colour on vertical surface such as skirting, dados, risers to steps etc set &jointed in neat cementslurry and pointed inwhite or coloured cementto matchincl dismantling / demolitionand e colour oftiles,incl dismantling / demolitionover and includingrendering10mm thick in cement mortar (1:4) , complete all as specified and directed. 22 Dismantling brick tiles or terracing single layer as in roofing complete all as specified and directed. 23 Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed. 24 M & L for 50mm avarage thicknessPCC 1:2:4type B1 (using 20 mm graded stone aggregate as roof padding complete all as specified and directed. 25 M&L for preparation of roof surface & applying evenly a tack coat of industrial bitumen primer 85/25 grade @ 1.2 Kg/SqmincludingAPP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced wih polyster non wove fabric (wt not less than 150 gms/sqm) land on primed surface by forced application, joints to be touched hot and width of overlaps not be less than 150 mm complete all as specified and directed. 26 M&L, 40 mm thick brick tiles laid over 15mm thick cement motar (1:6) and joints grouted flush in cement Motar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed. 27 ditto -as per ser item No 23.00 abovebut except bricks tiles complete all as specified and directed. 28 Roughening surfaces of old concrete floor/terrace by picking incl. taking down existing detoriated / decayed tar felt PCC tiles or any type oftreatment including loose surface, scraping with scraper, chiseling, scraping of surface with wire brush or any other method, sweeping clean & washing down with water to remove dust etc. and removing the scraped materials debris to a distance not exc. 50 m. complete all as specified and directed. 29 M & L for applying two coat of undiluted thick coat of acrlic reinforcement liquid applied elastorneric water proofing membrane with UV resistance properties and solar refective properties over one coat of primer (1:3, Dilution:water) Note: Every each coat gap between 6 hrs) complete all as specified and directed. 30 Taking up or down 15mm dia steel tubing and connections incl cleaning for refixing or removal to store all as specified and directed. 31 Taking down PE-AL-PE composite pipes 15 mm bore concealed/any type including connections complete all as specified and directed by Engr-In-charge. 32 S&F 15mm dia GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floors all as specified and directed. 33 Fixing only all as per ser item No 29.00 above but except pipe complete all as specified and directed. Note:Serviceable pipe obtained from ser item No 27.00shall be used after necessary cleaning 34 Taking up or down 20mm dia steel tubing and connections incl cleaning for refixing or removal to store complete all as specified and directed. 35 Taking down PE-AL-PE composite pipes 20mm bore concealed/any type including connections complete all as specified and directed by Engr-In-charge. 36 S&F 20mm dia GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floors all as specified and directed. 37 Fixing only all as per ser item No 33.00 above but except pipe complete all as specified and directed. Note: Serviceable pipe obtained from ser item No 31.00 shall be used after necessary cleaning. 38 S & F in repair 15mm bore dia fancy type chromium plated long body bib tap with crutch or buttewrfly handle screwed down to iron pipe with all fittings complete all as specified and directed. 39 S & F in repair 15 bore dia chromium plated Stop cock/Angle cock/conceled cock screwed down high pressure with crutch or butterfly handle & screw both end for iron pipe or for unions complete all as specified and directed. 40 S&F for in repair 15mm swan neck pillar cock chromium plated fancy type screw with iron pipe incl all fittings complete all as specified and directed. 41 S&F in repair, overhead shower 150mm x150mm square shape single flow (ABS body chrome plated with gray face plate ) incl shower arm 190mm long with rubit cleaning system complete all as spd and directed. 42 S and F in repair brass chromium plated tubular towel rail D type 60cm long between flangesincluding bracket complete all as specified and directed. 43 Supply and fix sheet glass shelf assembly consisting of 5.50mm thick sheet glass shelf 12cm wide with cromium plated bracket guard and and railing 60cm longincluding taking down old broken glass shelf, if available, complete all as specified. 44 Supply and fix toilet paper holder with flat recessed type stainless steel complete all as specified and directed 45 S&F in repairlooking mirror 600x450mm selected quality bevelled edges 5mm thick incl aluminium frame mounted on 5mm thick block board brracket and fixing arrangement complete all as specified and as directed. 46 S&F in repair10 ltrs capacity PVC valveless. Syphonic action type, flushing cistern, lowlevel, with inlet, ball valve, float, and handle and bracketsincluding 32mm dia flush pipe of polyethylene ofhigh density for low level cistern complete all as specified and directed. 47 S & F in repair for viterous china wash down water closet pan (pedestal pattern) coloured includingP or S trap with flush pipe of chromium plated brass 32 mm dia for low levelflushing cistern incl plastic seat cover white closed pattern with float bottom and cover and jet connection and mild steel chrominum plate or aluminized hanging device fixed in repairs complete all as specified and directed. 48 S&F in repairfor viterous china squating pan of (Orissa Pattern) size 580 x 440 white with P or S trap front or back inlet and integral foot rest ,including joining, filling and provision of cement concrete bedding 1:5:10, type E2 (excluding flushing cisteern and flush pipe) fixed inclcement concrete bedding as required set complete all as specified and directed. 49 Supply & Fixing in repairs vitreous china urinal half stall type with CP spreader white with grating and union for discharge pipe, including providing and fixing plug, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement fixing with brackets, flush pipe, grating and union for discharge pipe complete all as specified and directed 50 Dismantling of brick works in cement mortar complete all as specified and directed. 51 M & L for brick work with sub class B bricks in Cement motar (1:6) straight or curved on plan exc 6 mtrs mean radius,complete all as specified and directed. 52 M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls built in CM 1:4 complete all as specified and directed. 53 S&F, in repair Health Faucet/hand shower with 8mm dia 1mtr long easy flexible tube with chrome finish & wall hook complete all as specified and directed. 54 S&F in repairs grating doom 125mm dia PTMTwith waste hole (Min weight 40 grms) complete all as specified and directed. 55 S&Fin repair 450mm long PVC connections with PTMT nuts of suitable for 15mm bore dia pipe complete all as specified and directed. 56 Supply and fixed in repair PVC waste pipe 32mm bore of size and 900mm long complete all as specified and directed. 57 Supply & fix in repair, Vitreous China Wash Hand Basin, white, flat back, size 550 x 400 mm including brass coupling, mild steel brackets fixed to wall with pedestal etc. complete all as specified and directed. 58 S & F 110 mm bore PVC (SWR)pipes single socketed in any length with rubber ring joints and necessary fittings laid in floors/wall or trenches incl taking down old pipe complete all as specified and directed. 59 S&F 75 mm bore PVC (SWR)pipes single socketed in any length with rubber ring joints and necessary fittings laid in floors/Wall or trenches incl taking down old pipe complete all as specified and directed. 60 S&F, 75mm bore PVC (SWR) bend, any radius with access door complete all as specified and directed. 61 S&F, 110mm bore PVC (SWR) bend, any radius with access door complete all as specified and directed. 62 S&F, 75mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed. 63 S&F, 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed. 64 Taking down old shutters of any description exc. 1.0sqm but not exc. 2.0sqm each complete all as specified and directed. 65 S&F PVC door frame size 50mm x 47mm made out of 5mm plain coloured PVC sheet reinf with MS square tube supplying& fixing in opening as per specificationn make Rajshree. 66 S&F MS framed work as in door or gates of angle or other section with gusset plates,rail, braces,etc and similar work conform-ing to Fe 290 Gde E-165 complete. 67 S&F factory made solid PVC moulded door shutter with wood free solid board , 28 to 30 mm thick (stiles) with 2, 4 or 6 rised panel design with 5mm thick 3D wood laminated mouldedPVC sheet Polyurethane painted on the front and back face with with 19 guage thicknessusiing MS square tuning supplying and fixing of 19mm x19mm frame structurecomplete all as specified & directed. 68 Supply & fix in repair, brass chromium plated single lever wall mixer3-in-1 system with provision of both over head showerwith 115 mm long bend pipe connecting legs and wall flange (wihout head shower) complete all as specified and directed. 69 S&F, stainless steel butt hinges, of size 100 mm complete all as specified and directed. 70 S&F, aluminium anodised, barrel tower bolts of extruded section with length of bolt 150 mm and fixed complete all as specified and directed 71 S&F extruded aluminium alloy handles, fabricated type, anodised of size 150 mm complete all as specified and directed. 72 Material and labour for repairing of RCC projection, chajjas, facia,bands, shelves, beams, RCC railing, balcony and similar works by dismantling of loose/ disintegrated portion RCC at any height and in any sitution floor (including provn of support,formwork and welding of reinforcement if required with wire mesh of weight 3 kg/ sqm and dubbing/ fillingwith PCC (1:2:4), type B-0, using 12.5 mm graded aggregate,15 to 25 mm thickafter applying cement slurry @ 3 kg/sqm, finished even and smooth to desired shapeand applyingtwo coats of wheater proof emulsion paint to match with existing surfaces complete all as specified and directed.

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 49 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail