Tender For Provision Of Certain Sanctioned Em Works At Kapurthala And Beas Under Ge Kapurthala.; 1 Supply, installation, testing of clearwater pump of 10 HP capacity with diesel engine driven horizontal end suction, centrifugal type with CA casing, bronze/steel impeller and stainless steel shaft mounted on heavy duty bearings/bushes suitable for clear watersuction and discharge dia shall not be less than 65mm mounted on base frame with suitable coupling mounted on trolly as approved by deptt including foot valve, PVC suction heavy ducts pipe suitable dia of pump -10RM, discharge PVC heavy duty pipe of suitable dia of pump - 30RM complete all as specified and as directed of make : Kirloskar/KSB/Lubi/CRI 2 Supply & installation Galvanized steel high mast light suitable for 6 to 9 lantern symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch with luminaire mounting arm, pully assembly, aviation obstruction light, lightning arrester spike including RCC foundation as per height - 15/16 meter complete all as specified and directed by Engr-in-Charge. 3 Supply and fixing LED flood light 200/210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed by Engr-in-Charge. 4 Supply and fixing Outdoor type control panel for automatic operation of high mast lights including digital astronomical timmer, protection switchgears complete capacity not less than 5 KW, 3 phase all as specified and directed by Engr-in-Charge. 5 Supplying, laying, jointing and testing under ground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 vols grade cross sectional area 50 Sqmm 3.5 core laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and as directed by Engr-in-Charge. 6 Supplying, laying, jointing and testing under ground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 vols grade cross sectional area 25 Sqmm 3.5 core laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and as directed by Engr-in-Charge. 7 Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for foundation of poles/ stays/ laying of cables etc and gettingout including trimming of sides of trenches complete all as specifiedand directed by Engr-in-Charge. 8 Returning, filling the soft / loose soil including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer complete all as specified and directed by Engr-in-Charge. 9 Removing of surplus excavated soilto a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point completeall as specified and directed by Engr-in-Charge. 10 Material and labour for sand cushioning to under ground cable with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable complete all as specified and directed by Engr-in-Charge.Note : For payment purpose 18cm thickness shall be considered. 11 Material and labour for brick protection using old size sub class ‘B’bricks, laid flat, dry adjacent to each otherlaid length wiseperpendicular to theaxis of cable complete all as specified and directed by Engr-in-Charge. 12 Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 2 Ton complete all as specified and as directed by Engr-in-Charge. 13 Supply and fix voltage stabilizer for automatic operation, single phase each naturallyair cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabalized at 230 V with accuracy of + 2.5% and of capacity 5 KVA complete all as specified and as directed by Engr-in-Charge. 14 Supply and fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed by Engr-in-Charge. 15 M&L for sub main wiring with two runs of single core PVC insulated, unsheathed cooper conductor, multi strandard cable of size 4.0 Sqmm 1100 volts grade down PVC concealed conduit of size 19/20 mm (ISI marked) including PVC accessories complete incl cutting and chasing and making good etc including one run of 4.00 Sqmm single core cooper conductor multi-standard PVC insulated, unsheathed cable as earth wire continuity conductor complete all as specified and directed by Engineer-in-Charge.Note : Two run of 4.00 Sqmm cable one run of 2.5 Sqmm cable as earth contiuity conductor and one run of PVC Conductor shall be measured & paid as one unit. 16 M&L for point wiring with 4.00 Sqmm single core multi-stranded cooper conductor PVC (FR) insulated, unsheathed cable 1100 volt grade in PVC concealed conduit of size 19/20 mm (ISI Marked) including PVC accessories (concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 4.00 Sqmm single core, multi-stranded copper conductor, PVC insulated, unsheathed cable for common earth and connecting for earth dolly for 5 pin, 15 Amp socket outlet on independent board. 17 Supply and fix switch piano flush type 16 A, sngle pole, one way complete all as specified and directed by the Engineer-in-Charge. 18 Supply and fix socket outlet, 5 pin 16 A, multipurpose flush type complete all as specified and directed by the Engineer-in-Charge. 19 Supply, Instal, commission and test water cooler electric driven single phase aprox storage capacity 80 litres and nominal cooling capacity 40 litre/hours 5 star rated complete all as specified and directed by the Engineer-in-Charge. Make : Sidwall/Blue Star/Usha 20 Supply and fix wall mounted voltage stabalizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 to 285 V, with output voltage stabilized at 230 V with accuracy + 2.5% and of capacity 3 KVA complete all as specified and as directed by Engr-in-Charge. Make : V Guard/Blue bird/Microtek