Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-06-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 23-06-2025 |
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminium point wiring (light/fan/socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc including making good the disturbed surfaces to match with the existingcomplete all as specified and directed |
| 2 | Taking down unserviceable main switches, DBs including MCBs, bus bars chambers etc from wall/existing main boards and removing from sitecomplete all as specified and directed |
| 3 | M&L for point wiring with single core FRLS, PVC insulated, unsheathed multi stranded copper conductor of size 1.5sqmm alongwith 1.5sqmm earth wire of multi strand copper conductor (with same specification) drawing through existing conduit pipe including replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick withGI metal flush box of 1.60mm thick suitable for modular/conventional switches/sockets/fan regulators with cover plates (modular/conventional type as required), blanking plates, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete for the following :- |
| 4 | One light point controlled by one switch |
| 5 | Oneceiling/exhaust fan point controlled by one switch |
| 6 | One socket outlet 5 Amps controlled by one switch on same board |
| 7 | One socket outlet 5 amps controlled by one switch on independent board |
| 8 | One bell point controlled by one bell push switch |
| 9 | All as per the description srl item No 3.00 above but wiring with 2.5sqmm copper wire and 2.5sqmm earth wire for socket out let 16 Amps on independent board complete all as specified and directed. |
| 10 | All as pert the description srl item No 3.00 above but wiring with 4sqmm PVC insulated multi-stranded copper conductor for industrial socket outlet 3 pin 16/ 20 amps point and one single core 4sqmm PVC insulated unsheathed copper cable as earth continuity conductor |
| 11 | M&L for point wiring concealed type with 1.5sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC surface conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories, GI metal flush box of 1.60mm thick suitable for modular / conventional switches / sockets / fan regulators with cover plates (modular/ conventional type as required), blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :- |
| 12 | One light point controlled by one switch |
| 13 | Oneceiling/exhaust fan point controlled by one switch |
| 14 | One socket outlet 5 amps controlled by one switch on same board |
| 15 | One socket outlet 5 amps controlled by one switch on independent board |
| 16 | One bell point controlled by one bell push switch |
| 17 | All as per the description srl item No 6.00 above but with 2.5sqmm nominal cross sectional area copper conductor cable for one 16 amps socket outlet point on independent board with 2.5sqmm nominal cross sectional area copper conductor cable as continuous earth wire complete all as specified and directed. |
| 18 | All as per the description srl item No 6 .00 above but wiring with 4 sqmm PVC insulated multi-stranded copper conductor for industrial socket outlet 3 pin 16 / 20 Amps point and one single core 4 sqmm PVC insulated unsheathed copper cable as earth continuity conductor complete all as specified and directed. |
| 19 | S&F switch piano flush type 5/6 amps single pole one way230 volts complete all as specified and directed. |
| 20 | S&F switch piano flush type 15/16 amps single pole one way 230 volts complete all as specified and directed. |
| 21 | S&F socket outlet 2 in 1, 3 pin 5 ampsflush type 230 volt complete all as specified and directed. |
| 22 | S&F socket outlet 2 in 1,3/6 pin 5 and 15 amp flush type 230 volts complete all as specified and directed. |
| 23 | S&F for bell push, flush type 5 amp 230 volts complete all as specified and directed. |
| 24 | S&F electronic fan step regulator flush switch type 100/120 watt, 230 volt complete all as specified and directed. |
| 25 | S&F ding dong bell, AC, 230 volts, single pole complete all as specified and directed. |
| 26 | S&F lamp holder, 230 volt AC, PVC / polycarbonate type with back plate suitable for batten fitting including 9 watt LED bulb, 6500 K complete all as specified & directed |
| 27 | S&F ceiling rose, 6 amps, 250 volts, ACwith three terminals and PVC / polycarbonate insulated body of 50mm x 25mm sizecomplete all as specified and directed. |
| 28 | S&F modular switch 6/10 amps, one way, one module 240 volts complete all as specified and directed. |
| 29 | S&F modular socket, 3 pin 6 amps,240 volts, 2 module complete all as specified and directed. |
| 30 | S&F modular switch 16 amp , 1 module,240 volts complete all as specified and directed. |
| 31 | S&F modular socket 6/16 amp, 5 pin, 2 module, 240 volts complete all as specified and directed. |
| 32 | S&F modular bell push 6 amps, one module 240 volts complete all as specified and directed. |
| 33 | S&F modular fan regulator, step type, 120 watt, humfree, AC, 230 volts, 2 module complete all as specified and directed. |
| 34 | S&F sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps \"C\" curve, 240 volt complete all as specified and directed. |
| 35 | M&L in repair for two single core (submain) PVC insulated cable with 4sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 4sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20mm dia or higher size, concealed in wall including all conduit and fixing accessories including cutting chases & making disturbed surfaces complete.Note:- Two run for neutral and phase and one run for continuous earth wire alongwith PVC conduit shall be measured as one unit length |
| 36 | All as per the description srl item No 25 above but with 6sqmm and 6sqmm as earth wire |
| 37 | S&F MCB DB, single pole and neutralwith 200 amps rated bus bar, 230 volts, glazed,double door type, IP-43,including connecting all connections of wire to MCBs with proper lugs & making good to the disturbed surface complete for the following no of way:- |
| 38 | 4 way |
| 39 | 8 way |
| 40 | 12 way |
| 41 | S&F loadline distribution box 4 way, AC, TP & neutral metal enclosure, glazed double dooor, 415 volt, AC, IP-43, concealed type with suitable bus bar, neutral link, earth link suitable for MCCB63/100 amps as incomer and MCB SP as out going complete all as directed |
| 42 | S&F MCB DP/SPN, 240 volts, AC of breaking capacity 10 KA,\"C\" curve and connections by using suitable copper lugs complete of following rating :- |
| 43 | 63 amps |
| 44 | 40 amps |
| 45 | S&F MCB SP, 240 volts, AC, 6 to 32 amps, breaking capacity 10 KA, \"C\" curve and connection by using suitable copper lugs complete all as specified and directed. |
| 46 | S&F MCCB 3 Pole, 415 volt, AC, fixed type, with breaking capacity 16 KA suitable for load line DB & connection complete of following rating :- |
| 47 | 63 amps rating |
| 48 | 100 amps rating |
| 49 | S&F in repairs of switch piano, flush type, 5/6 amp, single pole, one way, 230 volts complete all as specified and directed. |
| 50 | S&F in repairs of socket outlet 2 in 1, 3 pin, 5/6 amp, flush type, 230 volts complete all as specified and directed. |
| 51 | S&F in repairs of switch piano flush type 15/16 amp, single pole, one way, 230 volts complete all as specified and directed. |
| 52 | S&F in repairs of socket outlet 2 in 1, 3/6 pin 5 and 15 amp, flush type, 230 volts complete all as specified and directed. |
| 53 | S&F in repairs of bell push, flush type, 6 amp, 230 volts complete all as specified and directed. |
| 54 | S&F in repairs electronic fan step regulatorswitch fiush type 120 watt, 230 volt complete all as specified and directed. |
| 55 | S&F in repairs of modular switch 10 amps single pole one module, 230 volts complete all as specified and directed. |
| 56 | S&F in repairs of universal moudlar socket ,10 amps, 5 pin, 2 module, 230 volts complete all as specified and directed. |
| 57 | S&F in repairs of modular switch 16/20 amps single pole one module, 230 volts complete all as specified and directed. |
| 58 | S&F in repairs of modular socket 16/20 amps, 2 module, 230 volts complete all as specified and directed. |
| 59 | S&F in repairs of modular bell push with indicator 6 amps, one module |
| 60 | S&F in repairs of modular fan step regulator 120 watt 2 module , 230 volts complete all as specified and directed. |
| 61 | S&F in repairs LED bulkhead luminaire 10 watt of polycarbonate housing and enclosed with acrylic diffuser IP-65 protection including connection complete all as specified & directed. Make:- Cat part No LEDBK01015-02 of Eveready/Cat part No RUGBYGENXFTS10WLED865SSYMBOPC of Havells/Cat part No WT202WLED10SCWPSUS3PC of Philips or equivalent as approved by GE. |
| 62 | S&F in repairs LED Post top lantern luminaire with die cast aluminium spigot, lid cover and clear acrylic cover 40 watt, 5700 K with IP-65 protection including connection complete. Make:- Cat part No LEDPOST04015-02 of Eveready/Cat part No RUBYPT40WLED757PSYMTOPC of Havells/Cat part No BGP200LED45CWPSUGRCPCSPD of Philips or equivalent as approved by GE. |
| 63 | S&F in repairswall mountedLED batten with aluminium housing and integrated electronic drive18/20 watt fixture 4 feet provided for efficient heat dissipation with polycorbonate diffuser and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Cat part No LEDBTA02016-02 of Eveready/Cat part No LUMILINEPLUSPROBS20WLED865SPCSSIND of Havells/Cat part No BN170CLED20S6500PSUL120 of Philips or equivalent as approved by GE. |
| 64 | S&F in repairs surface and wall mounted LED batten 10 watt 2 feet long extruded aluminium housing provided for efficient heat dessipation with polycarbonate diffusser and integrated electronic drive, pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete all as specified and directed. |
| 65 | S&F in repairs wall mounting bracket decorative luminaire powder coated housing, SS finish fixture with opal glass diffuser suitable for GLS, B-22 lamp including connection complete all as directed. |
| 66 | S&F in repairs highly efficient round shape downlighter 25 watt, 240 volt, CCT 5700 K with driver suitable for ceiling cutout 225mm dia including connection complete. |
| 67 | S&F in replacement LED landscape bollard light 10 watt, 230 volt, inverted pyramid tripod type with soft 360 degree distribution,IP-65 protection, including necessary civil work for grouting & foundation work of suitable size with PCC work complete all as specified and directed. Make:- Cat part No LEDBLM00913-01of Eveready/Cat part No MOUNTBL10WLED830PSYMTOPMMA of Havells/Cat part No BCP150LED150/WWPSU220-240V7043 of Philips or equivalent as approved by GE. |
| 68 | S&F in repairs surface/ceiling mounted LED panel type of size 2fit x 2fit, 36 watt, 230 volt, 5700K complete with driver full window glarefree opal diffuser LED panel with CRCA powder coated white housing complete with all accessories required for connection and making good the disturbed ceiling complete all as specified and directed.Make:- Cat part No LEDPLB03616-03NS of Eveready/Cat part No VENUSTREND2x2PLR36WLED865SWH of Havell/ Cat part NoRC380BLED36S-6500G6L60W60PSU0DS1 of Philips or equivalent as approved by GE. |
| 69 | S&F in repairs of LED linear surface/ suspended fittings, extruded aluminium body with opal polycarbonate diffuser, 38 watt, 4 fit long, CCT 6000 Kincl connection complete all as specified and directed. |
| 70 | M&L for LED Flood Light luminaire, energy saving & enviornmental friendly, long lifediecast aluminium, IP65, with high power LED as light source including necessary fixing arrangement with clamps of suitable size and connectionusing 1.5sqmm PVC insulated copper cable complete all as directed for following wattage. |
| 71 | 70 watt Make:- Cat part No LEDFL08015-04 of Eveready/Cat part No JETALEGANZAFLS70WLED757P60DTOTG of Havells/Cat part No BVP281LED085CWFGSY5WB70WV1 of Philips or equivalent as approved by GE. |
| 72 | 100 wattMake:- Cat part No LEDFL10015-04 ofEveready/Cat part No JETALEGANZAFLS100WLED757P60DTOTG of Havells/Cat part No BVP282LED120CWFGSY5WB100WV1 of Philips or equivalent as approved by GE. |
| 73 | M&L in repairs for loop junction box, outdoor type, size 30cm x 20cm x 15cm, made out of engineering plastic one piece moulding type, bus bar rating 63 amps 4 strips aluminium with bus bar mounting colour R, Y, B, N on DMC unbreakable insulator with cable entry main supply from bottom side and pole light connection from back side, simens grey colour, shock proof, rust proof, fire retardant, having front opening and locking arrangementwith MCB SP 10 amps - 01 No, box duly fixedon the pole with flat iron clamp of size 25mm X 3mm with nuts & bolts complete all as specified and directed.Note:- Cost of incoming & outgoing cable lugs & glands of suitable size is deemed to be included in the quoted rate. |
| 74 | M&L in replacement for LED street/security light fittings 60 watt, made up of of pressure die cast aluminium housing with toughned glass and individual high power LEDs with secondary optics, IP 66 protection, clamp type suitable for 32-50mm dia bracket pipe, to be mounted on existing/ new GI bracket and connecting the street light fitting using 1.5sqmm PVC insulated copper cable complete all as directed.Note:- New GI bracket with clamp shall be measured & paid seperately |
| 75 | S&F in replacement bracket for street light made out of 40mm bore GI pipe medium grade not less than 1.2 mtr length bent to shape fixed on pole/wall with and including50mm x 6mm FI clamps = 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 76 | S&F in repairs LED energy efficientflood lightof 35 watt,230 volt, anti glare diffuser, IP-65 including connection complete all as specified & directed.Make:- Cat part No LEDDNR00616-01of Eveready/Cat part No ZIVAFLRDDLR6WLED857S of Havells/Cat part No DN495LED6S6500PSUWH of Philips or equivalent as approved by GE. |
| 77 | S&F in repairsexhaust fan 300mm sweep heavyduty 1400RPM, 230 volt, AC, steel body with louver shutter etc complete and connection from ceiling rose to fan terminal including cutting of hole at wall for required size and making good disturbed surface and depositing old fan to store yard complete all as directed. |
| 78 | All as per the description srl item No 58 above but with 450/400mm sweep complete all as specified and directed. |
| 79 | S&F in repairs wall mounting fan 400mm sweep, adjustable, plastic blade grill for protection, pull cord control for speed and oscillation on-off, ABS body including connection and depositing old fan to store yard complete all as directed. |
| 80 | S&F in repairs PVC flexible twin twisted copper conductor cable multi strand of size 0.5sqmm nominal cross section complete |
| 81 | S&F electronic energy meter, current rating 10-60 amps, 240 volt, AC, single phase, 2 wire, accuracy class 1.0, with LCD display including/ fitted with temper proof meter box, weather proof, transparent, made out of FR polycarbonate, dust proof, good mechanical strength conforming to IS: 14772/2000, IP-65, size not less than 260mm x 190mm x 120mm including connection and depositing old meter to MES store complete all as directed |
| 82 | M&L for earthing with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer ofcharcoal dust and common salt filling in alternate layers and electrode connections by using GI wire of size 4mm dia as earthing leadupto the body ofthe equipment by means of GI bolts, nuts, check nuts and washers and thimbles and protected by light grade 20mm diaGI pipe connected to main switch board or main control board and GI pipe medium grade 15mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate, including excavation and earth work in any type ofsoil, returning, filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 ofSSR 2009 Part-I) complete |
| 83 | Taking down carefully electric geyser of any type and capacity bydisconnecting electric and water supply connection, opening nut, bolt, washer and reassembling after cleaning and replacing defective parts and re-installing the same in original position and making necessary electric and water supply connection and testing complete all as specified and directed. Note:- Spare items shall be measured and paid seperately. |
| 84 | S&F geyser inner water tank 35/50Ltrs capacity steel body as per sample, duly tested complete all as specified and directed. |
| 85 | All as per the description srl item No 65 abovebut 25 Ltrs capacity |
| 86 | S&F heating element capacity 1.5 KW (Round/Triangular) ISI marked suitable for geyser as per sample complete all as specified and directed. |
| 87 | All as per the description srl item No 67 above but capacity 2 KW |
| 88 | S&F thermostat suitable for 50/35/25 ltrs capacity geysers complete all as specified and directed. |
| 89 | S&F heavy duty hot water connection, SS rope threaded type with brass unions at both ends, 45cm long 15mm bore complete all as specified and directed. |
| 90 | S&F indicator lamp, Red/Green suitable for geyser of any type/capacity complete all as specified and directed. |
| 91 | S&F geyser base plate assembly of any type (having 6 or 9 hole) any model all as specified and directed. |
| 92 | S&F in replacement of outer cover MS sheet/ABS body of geysers 25 to 50 Ltrs capacity complete all as specified and directed. |
| 93 | S&F in repairs plug top, 3 pin, 05 amps, 230 volt complete all as specified and directed. |
| 94 | S&F in repairs Plug top, 3 pin, 15 amps, 230 volt complete all as specified and directed. . |
| 95 | S&F in repairs PVC insulated and sheathed flexible cable 3 core Multi-stranded copper conductor size 2.5sqmm 1100 volt grade after taking out old unserviceable one including electric connection complete all as specified and directed. |
| 96 | S&F in repairs precast RCC earthing pit with CI cover ISI marked including angle iron frame made out of 35mm x 35mm x 4mm thick for supporting the edges of pit cover as dimension shown inelectrical plate No-2 of SSR part-I complete all as specified & directed |
| 97 | M&L for dismantling of unsv ceiling fan of any make/model/sweep, cutting and removing the old defective/burnt winding, cleaning the core of fan motor and rewinding the fan motor with super enamelled copper winding wire of same gauge with insulating material and varnishing the core assembly, drying the moisture content to get appropricate speed and re-assemble the same complete all as directed.Note:- The cost of copper winding wire is deemed to be included in the quoted rate. |
| 98 | All as per the descripton srl item No 78 above but for exhaust fan upto 300mm sweep size |
| 99 | All as per the description srl item No 78 above but for exhaust fan of 380/450mm sweep size |
| 100 | S&F in repair capacitor 2.5/3.15 MFD suitable for C/fan including connection complete all as specified and directed. |
| 101 | S&F in repairs pedestal fan 500mm sweep with strong copper wound motor for better air delievery, smooth oscillation, superior low voltage performance, heavy base for stability, 3 speed control regulator, speed not less than 1400 RPM and old to be deposited in store yard complete all as directed. |
| 102 | M&L in repairs ball bearing suitable for any type/size/make of fan complete all as directed. |
| 103 | S&F in repairs factory made metallic louver shutter duly painted complete all as specified and as directed for following size of exhaust fan. |
| 104 | 300mm sweep |
| 105 | 450mm sweep |
| 106 | S&F in repair factory made ceiling fan down rod made out of heavy duty MS conduit pipe of 15mm dia duly with powder coat painted hole at both ends for passing cable/nut and cut at one end for fixing of fan shaft including nut bolt complete all as specified for the following sizes :- |
| 107 | 30cm |
| 108 | 60cm |
| 109 | 90cm |
| 110 | 120cm |
| 111 | M&L for taking down carefully window/split type air conditioner 2/1.5 ton capacity of any type/make from window/wall and removing front grills, air filters and cleaning, removing dust, washing and servicing with chemical wash of cooling and condenser coil and re-assembling the dismantled components and fixing to its original position complete all as specified |
| 112 | M&L for servicing of water cooler of any capacity, any type/make including disconnection of electric /water supply connection and servicing with washing, removing dust and fixing its original position including electric and water connection complete all as specified and directed. |
| 113 | M&L for charging of refrigerant R-22 / R-410 or any other recommended refrigerant gas in 1.5/2 ton window/split air conditioner/ refrigerator/ deep freezer/ water cooler any cap including detecting leakage and rectify the leakage with proper brazing and testing on full load complete all as specified and directed. |
| 114 | S&F in repairs starting/running capacitor 55 to 80 MFD, 240 volt suitable for water cooler/window AC /split AC including connection complete all as specified and directed. |
| 115 | S&F in repairs starting relay suitable for air conditioner 1.5/2 ton/ water cooler/deep freezer/ refrigerator any cap complete all as specified and directed. |
| 116 | S&F in repairs fan motor assembly of water cooler any cap of cooling capacity 40 to 80 ltr per hour including all accessories complete all as specified and directed. |
| 117 | M&L for replacement of fan blower motor copper wound of window type air conditioner 1.5 /2 ton capacity with same rating 220/230 volt complete all as directed |
| 118 | M&L for replacement of fan blower motor blade of window type air conditioner 1.5 /2 ton capacity complete all as specified and directed. |
| 119 | S&F in replacement of thermostat switch suitable for window/split air conditioner, ISI marked of any make all as specified and directed. |
| 120 | S&F in replacement of thermostat switch with knob suitable for water cooler, ISI marked of any make/type capacity including making electric connection complete all as specified and directed. |
| 121 | M&L in repair copper tubing 1/2\" dia with existing gauge for suction/discharge line of split air conditioner of 1.5 ton/tTon capacity including high quality puf insulation complete all as specified and directed. |
| 122 | All as per the description srl item No 96 above itembut size 3/8\" dia |
| 123 | S&F in repair outdoor unit suitable for 1.5 ton split AC including rotary type compressor, high EER, copper material condenser unit, eco friendly refrigerent etc with all accessories ccomplete all as specified and directed. |
| 124 | All as per the description srl item No 98 above item but for 2 ton split AC |
| 125 | S&F in repairs of cromium plated brass push cock 15mm dia, ISI marked, for water cooler complete all as directed |
| 126 | S&F in replacement Motor single phase, 1/5 HP capacity for split type AC 1.5/2.0 ton capacity complete all as directed |
| 127 | S&F in replacement hermetically sealed rotary type compressor unitof capacity 1.5/2 ton for split/window type AC and charging of adequate quantity of refrigerant gas and testing on completion complete all as specified and directed. |
| 128 | All as per the description srl item No 102 above but for water cooler of any capacity/make |
| 129 | S&F in repair power circuit board (PCB) suitable for split/ window type AC of capacity 1.5TR / 2.0 TR with all standard features i.e. power on-off, fan cooling speed, timer, temp etc complete all as directed |
| 130 | S&F in repair copper condensing unit of split air conditioning cooling coil unit 1.5/2 ton of any make complete all as directed (Charging of refrigerant will be measured and paid separately) |
| 131 | S&F in replacement of front grill of window type air conditioner 1.5 ton, any make /type complete all as directed |
| 132 | S&F in repairs indoor unit suitable for 1.5 ton split AC with PCB, LCD with temperature remote controller, noise level not less than 40 db etc with all accessories complete in all respect all as directed. |
| 133 | All as per the description srl item No 107 above item but for 2 ton split AC |
| 134 | S&F 6mm thick plywood sheet (ISI marked), waterproof fixed in window of required size including cutting for passing air of desert cooler complete all as directed |
| 135 | S&F in repairs plastic submersible pump suitable for desert cooler any size complete all as directed. |
| 136 | S&F desert cooler pad (set of three) made out of wood etc for desert cooler any size complete all as specified and directed. |
| 137 | S&F in repairs fan motor kit assembly of 500mm sweep, single phase, not less than 145 watt, 230 volt, AC, 50 Hz, copper wound with blade for desert cooler complete all as directed. |
| 138 | S&F in repairs electric water heater, storage type 25 ltrs capacity, BEE star rated, vertical type with suitable size of fastner and including provision and connecting up of SS braided pipe with adapter for inlet and outlet water connection, copper element corrosion resistance antiscaling magnesium anode having adustable knobe for temperature control and inner tank material of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure having heating element 2 KW and minium two year warranty on product, minimum three years on heating element complete all as specified and as directed. Make:-Omnis R of Racold/Cat part No Urja + 25 Ltr of Orient/Cat part No GHWAMGSWH025 of Havells or equivalent as approved by GE. |
| 139 | S&F ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 volt, 1200mm sweep. minimum air delivery 210 CFM with service value 6.00 BEE. five star rated with brushless direct current motor (BLDC) all as directed |
| 140 | S&F in replacement of transformer of compressor 0-15 volt,500 miliampere of 24 TR central AC plant. |
| 141 | S&F in repairs transformer of compressor, 0-8 volt, 500 miliampere complete of 7.5 TR package type AC plant. |
| 142 | S&F in repairs motorized mixing valve 3 way, 65mm dia for chiller pumpwith 50mm thick EPS insulation and 26 gauge aluminium cladding of central AC plantcomplete. |
| 143 | S&F in repairs motorized mixing valve actuator 3 way, 65mm dia for chiller pumpwith 50mm thick EPS insulation and 26 gauge aluminium cladding of central AC plantcomplete. |
| 144 | M&L for replacement micro processor panel unit PMN single, 7-22 amps soft halt, 220 volt with display remote circuit, time relay and FRP cable complete for package type AC plant. |
| 145 | S&F in repairs contractor 40 Amps, 3 pole, AC-3 rating complete of central AC plant complete all as specified and directed. |
| 146 | S&F in repairs heavy duty cast iron non return valve 80mm dia flanged type with 50mm thick EPS insulation and 26 gauge aluminium cladding complete all as specified and directed. |
| 147 | S&F in repairs of filter drier having 10 micron outlet filter,100 % molecular sieve to maximize water absorption suitable for R-22/ R-407C refrigerant all as specified and directed |
| 148 | M&L in replacement of condensing cooling fan motor, up to 1 HP, single phase with copper winding all as specified and directed. |
| 149 | M&L for replacement of copper condensing /cooling coil with fan complete suitable for central/package type AC plant complete all as directed |
| 150 | S&F in repairs of PCB with digital card of central AC plant 22 TR capacity including computerized programming of digital card with showing all connected features complete. |
| 151 | S&F in repairs for for denfoss commercial compressor for 22TR capacity chiller plant with complete all as specified and directed. |
| 152 | S&F in repairs humidity heaters/ winter heating heater, 3 KW, type FSH, ISI marked complete all as specified and directed. |
| 153 | M&L for replacement of thermostatic expansion valve (TGEX) suitable for 11 TR compressor 38 KW, R-22/R-407C, PS-46 bar complete all as specified & directed |
| 154 | S&F in repairs water pressure gauge 0-150 pound, 100mm dia complete all as specified & directed. |
| 155 | S&F in repairs brass water flow switch for 25mm dia pipe, operating pressure 10 Kgs/Cm2, in line type complete all as specified and directed. |
| 156 | S&F in repairs fan belt V type No. B-87, ISI marked, for AHU blower complete all as specified and directed. |
| 157 | M&L in repairs water temperature sensor PT-100 complete all as specified & directed |
| 158 | S&F in repairs heavy duty cast iron butterfly valve 80mm dia, flanged type with 50mm thick EPS insulation and 26 gauge aluminium cladding complete all as specified & directed |
| 159 | S&F in repairs digital industrial thermostate 230 volt AC, 0-30 °C tempereture complete all as specified and directed. |
| 160 | S&F in repairs blower motor fan belt No A-32, ISI marked complete all as specified and directed. |
| 161 | M&L for servicing of chiller plant 22 TR capacityincluding AHU with cleaning, removing dust, chemical wash of cooling and condenser coil and re-assembling the dismantled components and fixing to its original position complete all as specified |
| 162 | M&L for any kind of leakage detection and repair of damage in central/package AC plantwith necessary welding/brazing the same as specified & directed. |
| 163 | S&F in repairs water temperature sensor EWT/LWT for central/package AC plantwith necessary connecting item complete all as specified and directed. |
| 164 | M&L for servicing ofpackage type plant 7.5 TR capacitywith cleaning, removing dust,chemical wash ofcooling and condenser coil and re-assembling the dismantled components and fixing to its original position complete all as specified |
| 165 | M&L for filling refrigerant R-407C in 24 TR chilling unit and detecting of leakage with repair of damage cooling coil tubes with necessary welding/brazing the same complete all as specified & directed |
| 166 | M&L for rewinding of fan motor 15 HP, 3 phase of AHU with copper winding wire of existing gauge including dismantling and refixing the same all as directed |
| 167 | M&L for rewinding of fan motor 3 HP, 3 phase of AHU with copper winding wire of existing gauge including dismantling and refixing the same all as directed |
| 168 | M&L for filling refrigerant R-22 in 7.5 TR AC plant unit and detecting of leakage with repair of damage cooling coil tubes with necessary welding/brazing the same complete all as specified & directed |
| 169 | M&L for rewinding of rotory type semi shield compressor model No. 6D/18 of voltas make for 7.5 TR package type AC plant with copper winding wire of existing gauge and dismantaling cutting the compressor withservicing and refixing the same on its origanal position complete all as specified & directed |
| 170 | M&L for rewinding of blower motor 3 HP, 3 phase for 7.5 TR package type AC plant with copper windng wire of existing gauge including reeplacement of bearing and complete servicing with dismantling and refixing the same on its original position complete all as specified & directed |
| 171 | M&L for rewinding of fan motor of exhaust fan 600mm sweep, 370 watt, 900 RPM of outdoor unit of package type AC plant 7.5 TR with supper enamelled copper winding wire of same gauge and testing to get existing specified speed complete all as directed |
| 172 | S&F in repairs of rotory type semi shield compressor model No 6D/18 of voltas make for 7.5 TR package type AC plant with copper winding complete all as specified & directed |
| 173 | S&F in repairs heavy duty M.S. ERW pipe 80mm dia including all fittings laid in trench/duct for chilled water pipe line of central AC plant with cutting, welding, bending complete all as specified and directed. |
| 174 | S&F in repairs insulation of M.S. pipeline 80mm dia with PUF slab 40mm thick with and including applying bituminuous compound and GI sheet cladding with 26 gauge sheet complete to avoid heat dissipation of chilled water pipe line of central AC plant complete all as specified and directed. |
| 175 | Cleaning of existing duct through high power vaccum cleaner, high pressure compressor air using special nozzle, brush, scrubblers, imported hepa aire equipment & technology complete all as specified and directed |
| 176 | S&F in replacement Athlete micro clean filter/hepa of size 610mm x 610mm x 305mm, pressure drop 6.5mmWG, micro rating 5, rated capacity 2000CFM complete all as specified and directed. |
| 177 | S&F in replacement athlete micro clean filter/hepa of size 610mm x 610mm x 50mm, micro rating 10, box type, complete all as specified and directed. |
| 178 | All as per the description srl item No 152 above but for size 300mm x 300mm x 50mm complete all as specified and directed |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail