| 1 | Dismantling of loose concrete cover from ceiling surface area n exc 1.50 Sqm including desursting of steel reinforcement and preparing the surface by cleaning dirt etc and applying chemical admixture over reinforcement and plastering the surface in two layer using chicken wiremesh before applying first layer First layer of rendering is done up to surface of previous thickness of concrete in CM 1:3 and second layer 10 mm thick rendering in CM 1:3 including three coat of white wash to match the existing complete all as specified and directed .Note Rate quoted shall be insclusive of all scaffolding props and shuttering. |
| 2 | Demolition of brick work built in cement mortar in any description and position, upto G+8 storey bldg complete all as specified.. |
| 3 | Brick work with old size bricks straight or curved on plan exceeding 6 metre mean radiusbuilt in cement mortar 1:6 (1 cement : 6 coarse sand), upto G+8 storey bldg complete all as specified. |
| 4 | All as per serial item No 3 but except bricks, all as specified. (Servicable bricks retrieved from Serial Item No 01 shall be used).upto G+8 storey bldg complete all as specified. |
| 5 | M&L for framed work as in door/vent/CB chowkats of angle or other section, frame work for chajjawith gusset plates, cooler stand, rails, braces etc complete drilled for fixing of steel sheeting or other covering and including cutting brick work for hold fast confirming to Fe 410-W (Gde-E-250) quality \"A\" including necessary welding complete all as specified and directed. |
| 6 | M&L for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, complete all as specified and adirected. |
| 7 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat molded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail lock rail and bottom rail and as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded etc. with suitable PVC sheet beading including hinges etc complete all as specified and directed. |
| 8 | S&F 35mm thick flush shutter solid core construction with block board core and plywood face panels, comercial type on both sides complete all as specified and directed. |
| 9 | S&F 35mm thick plain framed panelled shutters (any number of panels) with lock rails in IInd class HW and panels of 9mm thick BWP commercial ply or 12mm veneered parcticle board with commercial veneering on both faces, supplied and fitted to chowkat complete all as specified and directed. |
| 10 | S&F 35mm thick glazed skelton shutter IInd class hard woodrebated and prepared to received glass, gauge etc (with sash bars) edges of forming plain, chamfered or rounded fitted with mitred beads for securing glass etc complete all as specified and directed. |
| 11 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 12 | M&L for preparation of newsteel surfaces, painting two coats of synthetic enamel paints over a coat of red oxide primerexc 10mm width or girth complete all as specified and directed. |
| 13 | M&L for preparation of newwooden surfaces, painting two coats of synthetic enamel paints over a coat of pink primerexc 10mm width or girth complete all as specified and directed. |
| 14 | Taking down cement plaster in any thickness from brick or stoneetc including raking out joints, hacking for key, scrubbing down with water etc upto G+8 storey bldg complete all as specified. |
| 15 | M&L for plaster of 15mm thick in CM 1:6 on brick or concrete surfaces including necessary cement slurry with bulk densityapplied as per manufacturer instruction.upto G+8 storey bldg complete all as specified. |
| 16 | Preparation of newlyplastered surfaces of wallsand applying two coats of distemper over a coat of primer, complete all as specified and as directed. |
| 17 | M&L for sunken treatment as following over it complete all as specified and as directed:-(a) Rendering 10 mm thiick in CM 1:4,(b) Two coats of tapecrete mixed (1:2) with cement slurry @ 3Kg/sqm per sqm or as per manufactures\"s instruction, surface finished even and smooth(c) Applying a coat ofbitumen primer @ 0.70 kg /sqm, applying one coat of hot bitumen 85/25 gde @ 2.6 kg/sqm (d) Applying one layer of 0.5 mm thick fibre tissue/APP membrane |
| 18 | S&F in repair vitreous china, squattingpan \"Orissa\" pattern \"white\" size 580mm x 440mm white with integral foot rest (excluding flushing cistern and flushing pipe)including provisionof lean concrete bedding connection to drain out pipeto flush pipe andanti syphonage pipe etc including making good to floor where required upto G+8 storey bldg complete all as specified. |
| 19 | M&L Preparingold decoratedplastered or un-plastered surfaces of wallsby scraping the surfaces, brooming down or steel wire brushing down smoke soot, mould, mass and efflorescence salts and trading oil and greasy spots complete removal of existing treatmentetc and applying one coat of Acrylic washable distemper on wall surfaces including preparation of surfaces by filling cracks/holes with white putty, up to G+8 storey bldg complete all as specified. |
| 20 | Description all as per serial item No. 19 above, but two coats of Acrylic washable distemper, complete all as specified and directed. |
| 21 | M&L for complete removal of existing treatment from internal surfaces of wall by mechanical sander of berger paints or equivalent makes viz xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying a coat of alkali resistant primer over already prepared surfaces of walls applying uniform thickness (avg 2mm thick ) wall care putty on internal surfaces of wall whereever required for preparaing the surface even and smooth and providing two coats of Oil Bound Distemper on wall surface using roller brush complete all as specified and directed by Engineer-in-Charge. |
| 22 | Preparation of old painted wood or wooden based surfaces of any description not otherwise described over 10cm width or girth,and applying one coat of synthetic enamel paint, upto G+8 storey bldg complete all as specified. |
| 23 | M&L for Preparation of old painted surfaces of steel and iron surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint, upto G+8 storey bldg complete all as specified. |
| 24 | Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premisescomplete all as specified and as directed |
| 25 | M&L for 600x600mm x7-8 mm rectified coloured ceramic tiles, joint free, as approved by Garrison Engineer in floors over 15mm thick screed bed in CM 1:6,G+8 storey bldg complete all as specified.(Make: Digital ceramicdigital Seriese of Somany or Equivqlent to Orient/Kajaria) |
| 26 | M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white oroloured cement to match laid over and including 15mm thick screed bed or bedding layers in cement mortar ( 1:6) G+8 storey bldg complete all as specified. |
| 27 | M&L Glazed ceramic coloured joint free tiles of size 450mmx300mm, 6 to 7mm thick on vertical surfaces of walls such as skirting dado etc and jointed in neat cement slurry and pointed in white cement to match laid over and including 10mm thick backing coat in CM 1:4 and including dismantling floor, hearth or wall tiling including cement mortor bedding (including backing) removing of rubbish beyond MOD land complete all as specified and directed. |
| 28 | M&L for PCC 25mm thick 1:2:4 typeB1( using 12.5mm graded crushed stone aggregates )as in sub flooringG+8 storey bldg complete all as specified. |
| 29 | S&F of 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed complete to walls, ceilings or in floors with suitable clamps/bracket including taking down old pipes and necessary cutting through RCC roof and brick work etc and making good all as specified. |
| 30 | S&F of 110mm dia PVC (SWR) bends any radius with solvent joints, complete all as specified. |
| 31 | Taking up or down 20 mm GI tubing medium grade with all fittings and connections incl cleaning for refixing or removal to store complete all as specified. |
| 32 | All as per item no.31here-in-before but dia of GI pipe is 15mm. |
| 33 | S&F 20mm dia GI tubing medium grade with all fittings and connections fixed to wall or ceiling or laid on floor etc incl cutting chasing where required complete all as specified an directed. |
| 34 | All as per item no.33 here-in-before but dia of GI pipe is 15mm. |
| 35 | Cutting chases,pinning for concealed water tubing andmaking good to facing where required and pointing in cement mortar 1;3 ,cutting exc 10cm but n.exc 20cm girth complete all as specified and directed. |
| 36 | S & F in repairs GI fittings such as union, Socket, Tee, Elbow, Nipple 4\"/ 6\", Reducer, Plug, Tank connection of 1/2\" in existing pipe line of 15 mm dia without taking down of pipe line in any position/situation complete all as specified and directed by Engineer-in-Charge. |
| 37 | S & F in repairs GI fittings such as union, Socket, Tee, Elbow, Nipple 4\" 6\", Reducer, Plug, Tank connection of 3/4\" in existing pipe line of 20 mm dia without taking down of pipe line in any position/situation complete all as specified and directed by Engineer-in-Charge. |
| 38 | Dismantling water tamk exc 250 but n exc 500 ltr and removing to store complete all as specified and directed by Engineer-in-Charge. |
| 39 | S&Fin repair 500 ltrs capacity rotational molded polyethylene water storage tanks three layered (cylindrical vertical with closed top) hoisted and fixed in position and including 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & 20mm dia tank nipple suitable for HDPE water tank, complete all as specified and directed. |
| 40 | M& L for cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as in plinth protection 75 mm thick laid in bays and surfaces finished even and fair, including filling the joints with bitumen masticincluding demolition of existing surface all as specified and disposing to debries etc all as directed by Engr-in-Charge. |
| 41 | S&F in repairCI floor trap with grating incl jointing to waste pipe fixed in cement concrete type B1 (1:2:4) dia of out let 75mm complete all as specified and directed by Engineer-in-Charge. |
| 42 | S & F in repairs vitreous chinaware coloured wash hand basinofsize 580mm x 450mm complete including, CP Waste coupling , PVC waste pipe ,complete fixing arrangementand cutting for and pinningin walls & making good complete all as specifed and directed by Engr in charge |
| 43 | S&F in repair vitreous china squatting pan of orissa pattern long pan size510 x 400 mm white with \"p\"or \"S\" trap front or back inlet and integral foot rest any pattern (excluding flushing cistern and flush pipe)complete all as specified and directed by Engineer-in-Charge. |
| 44 | S&F in repairs bib tap with crutch or butterfly handle, screwed down, screwed for iron pipe, 15mm dia, fancy type, cast copper alloy, chromium platedlong body with flange complete all as specified and directed by Engineer-in-Charge. |
| 45 | M&L 60 mm thick coloured cement concrete interlockingpaver blocks hydraulically pressed of compressive strength not less than M-35 grade, laid dry including 50 mm thick sand cushing & vibrating the pavers and joints filled with dry sandincluding dismantling of old paver block complete all as specified and directed . |
| 46 | M&L for Coloured Machine pressed cement concrete chequered tiles 30cm X 30cm X 25mm thick machine pressed; set jointed and pointed in neat cement slurry in floors and cut and pointed with white cement and pigment over and including 20 mm thick screed bed in cement mortor (1:6) complete all as specified and directed. |
| 47 | Dismantling of brick tiles or terracing tiles single layers as on roof including removal of rubbish beyond MOD land complete all as specified and directed. |
| 48 | Demolition of mud phuska in roof any thickness including plastering and leeping etc including removal of rubbish beyond MOD land complete all as specified and directed. |
| 49 | M&L PCC 1:2:4 type B0 (12.5 mm graded stone agg) as in roof padding etc complete all as specified and directed. |
| 50 | M&L for cleaning top surface or cement concrete surface with Wire brushing including flashings and junction of parapets, etc, including taking down old APP membrane / existing roof treatementincluding removal of rubbish beyond MOD land complete all as specified and directed. |
| 51 | M&L for applying water proofing treatment as following:- (a) 15mm cement plaster with cement mortar 1:4 on roof surfaces(b) A coat of bitumen primer @ 0.40 Kg/Sqm on prepared surface of plaster and applying a coat of bitumen 85/25 grade @1.2kg/Sqm (c) Applying APP based polymeric membrane minimum weight 3.50 Kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric/wt not less than 150 gm/Sqm and sealing joints by torched application bitumen. |
| 52 | M&L for 40mm thick brick tiles terracing over and including bedding layer of cement mortar 1:6, 15mmthick,including jointed and grouted in cement mortar 1:6,flush pointing in cement mortar 1:3 mixed with 5% of crude oil by weight of cement complete all as specified and directed. |
| 53 | All as item No 52 but Except tiles |
| 54 | M&Lfor 40 mm thick PCC 1:2:4 type B-1 ( 20 mm graded stone aggre) as floors finishing surfaces even and smooth using extra cement complete all as specified and directed by Engineer-in-Charge. |