| 1 | S & F in replacement Heavy duty chemical dosing system plunger type suitable to inject solution upto 25 LPH working pressure 10 Kg/cm2 comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP, 1440 RPM assembly with agitator in one motor, agitator with Stainless Steelsweep blade duly FRP coated, FRP tank 150 ltrs capacity, complete unit mounted on heavy duty MS fabricated frame duly anticorrosive paint complete with Chemical grade PVC NRV. Three phase panel DOL starter for Dosing Pump made of powder coated MS fabricated box consisting of LED indicator, digital Volt meter, Amp meter, single phase preventor, high voltage / low voltage protection.complete all as specified and directed. |
| 2 | S & F, in repair, Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc of size 15 mm bore, complete all as specified and directed. |
| 3 | Taking down existing sub main wiring with aluminium conductor cable of any size with GI earth wire on and including wooden batten and removing materials from the site complete all as specified and as directed. |
| 4 | M&L for provision of sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 2.5 sqmm drawn in and including rigid PVC conduit medium grade ISI marked not less than 25 mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size 2.5 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish complete all as specified & directed.Notes:- (i) Finished sub main wiring with two runs of 2.5 sqmm cable & one run of 2.5 sqmm cable alongwith PVC conduit and its accessories shall be measured and paid one unit length.(ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.(iii) Colour coding for wiring/ bus bar/ main connection shall be followed . |
| 5 | Taking out existing unserviceableXLPE cables, any type and any size,from its existing location complete all as specified and directed.( Note : Excavation and earthwork wherever required shall be measured and paid for separately against relevant items of this BoQ.) |
| 6 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes,1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 185 sqmm, 3.5 core including jointing materials such as cable glands & lugs etc complete all as specified and directed.(Note:- Excavation and earth work, sand cushioning, cable protection covers, cable protection pipewherever required shall be measured and paid for separately under respective items in this BOQ.) |
| 7 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes,1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 50 sqmm, 3.5 core including jointing materials such as cable glands & lugs etc complete all as specified and directed. (Note:- Excavation and earth work, sand cushioning, cable protection covers, cable protection pipewherever required shall be measured and paid for separately under respective items in this BOQ.) |
| 8 | Supply, install, testing and commissioning, in repleacement, LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size to accomodate the following accessoriestotally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type madeof 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron (50 x 50 x 5 mm) frame work with four legs grouted in PCC (1:2:4) type B1(using 20mm graded crushed stone aggregate) as foundation block with suitable mounting arrangement for bus bars, voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, duly powder coated with 700Amp electricalgrade copper bus bar for phases and neutralwith colour coated insulator sleeves, including danger notice plate complete with suitable digital type meters resin cast CTs, CPRI approved, type tested, internal wiring all includingthe following incoming complete all as specified and directed:-Note:- Connection from Main bus bar to OutgoingMCCB shall be provided through bus bar of suitable rating instead of copper wires |
| 9 | (a) MCCB 4P 630 Amps rating, 50 Hz, 415 V with rupturing capacity 50 KA, adjustable(b) MCCB 4P 125 Amps rating, 50 Hz, 415 V with rupturing capacity 25 KA, adjustable type - 04 Nos (outgoing)(c) MCCB 4P 100 Amps rating, 50 Hz, 415 V with rupturing capacity 25 KA, adjustabletype - 03 Nos (outgoing)(d) MCB TPN 20 Amps rating, C Curve, 415 V with rupturing capacity 10 KA - 02 Nos (outgoing)(e) MCB SPN 32 Amps rating, C Curve, 240 V with rupturing capacity 10 KA - 01 No (outgoing) (f) On load change over switch, 4 Pole, 500 Amps, 415 Volts - 01 No(g) Surge Protection Device (SPD), Three Pole and Neutral, Uc (V) 320 V, In (Ka) 20 kA, Imax (kA) 40 kA - 06 Nos (h) Fully automatic Motor Starter (Star-Delta) suitable for 60 HP centrifugal Pump set, 3 Phase - 04 Nos (j) Fully automatic Motor Starter (Star-Delta) suitable for 25 HP submersible Pump set, 3 Phase - 02 Nos(k) Single phase preventer, over load relays of suitable rating - 06 Nos (l) Voltmeter 0-500 V digital type with selector switch - 1 No (m) Indicator lamp LED type - 3 Nos (R, Y & B)(n) Digital type meters ampere meter with suitable selector switch including suitable resin cast CTs of 700/5 A - 01 No |
| 10 | Supply, install, testing and commissioning in repleacement, LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size to accomodate the following accessoriestotally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type madeof 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron (50 x 50 x 5 mm) frame work with four legs grouted in PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, duly powder coated with 1300Amp electricalgrade copper bus bar for phases and neutralwith colour coated insulator sleeves, including danger notice plate complete with suitable digital type meters resin cast CTs, CPRI approved, type tested, internal wiring all includingthe following incoming complete all as specified and directed:-Note:- Connection from Main bus bar to OutgoingMCCB shallbe provided through bus bar of suitable rating instead of copper wires |
| 11 | (a) ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 1000 Amps rating, 50 Hz - 01 No (Incoming) (b) MCCB 4P 250 Amps rating, 50 Hz, 415 V with rupturing capacity 36 KA, adjustable type - 05 Nos (outgoing)(c) MCB TPN 20 Amps rating, \"C\" Curve, 415 V with rupturing capacity 10 KA - 02 Nos (outgoing)(d) MCB SPN 32 Amps rating, \"C\" Curve, 240 V with rupturing capacity 10 KA - 01 No (outgoing)(e) On load change over switch, 4 Pole, 500 Amps, 415 Volts - 01 No (f) Surge Protection Device (SPD), Three Pole and Neutral, Uc (V) 320 V, In (Ka) 20 kA, Imax (kA) 40 kA - 05 Nos(g) Fully automatic Motor Starter (Star-Delta) suitable for 100 HP centrifugal Pump set, 3 Phase - 05 Nos(h) Single phase preventer, over load relays of suitable rating - 05 Nos (j) Voltmeter 0-500 V digital type with selector switch - 1 No(k) Indicator lamp LED type - 3 Nos (R, Y & B)(l) Digital type meters ampere meter with suitable selector switch including suitable resin cast CTs of 1300/5 A - 01 No |
| 12 | Supply, install, testing and commissioning, in repleacement, LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size to accomodate the following accessoriestotally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron (50 x 50 x 5 mm) frame work with four legs grouted in PCC (1:2:4) type B1(using 20mm graded crushed stone aggregate) as foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, duly powder coated with 500A electricalgrade copper bus bar for phases and neutral with colour coated insulator sleeves, including danger notice plate complete with suitable digital type meters resin cast CTs, CPRI approved, type tested, internal wiring all includingthe following incoming complete all as specified and directed:-Note:- Connection from Main bus bar to OutgoingMCCB shallbe provided through bus bar of suitable rating instead of copper wires |
| 13 | (a) MCCB 4P 400 Amps rating, 50 Hz, 415 V with rupturing capacity 50 KA, adjustable type - 01 No (Incoming) (b) MCCB 4P 200 Amps rating, 50 Hz, 415 V with rupturing capacity 36 KA, adjustable type - 02 Nos (outgoing)(c) MCCB 4P 63 Amps rating, 50 Hz, 415 V with rupturing capacity 16 KA, adjustable type - 01 No (outgoing) (d) MCB TPN 20 Amps rating, \"C\" Curve, 415 V with rupturing capacity 10 KA - 02 Nos (outgoing)(e) MCB SPN 32 Amps rating, \"C\" Curve, 240 V with rupturing capacity 10 KA - 01 No (outgoing)(f) On load change over switch, 4 Pole, 400 Amps, 415 Volts - 01 No(g) Surge Protection Device (SPD), Three Pole and Neutral, Uc (V) 320 V, In (Ka) 20 kA, Imax (kA) 40 kA - 03 Nos(h) Fully automatic Motor Starter (Star-Delta) suitable for 75 HP Centrifugal Pump set, 3 Phase - 02 Nos (j) Fully automatic Motor Starter (Star-Delta) suitable for 25 HP Centrifugal Pump set, 3 Phase - 01 No (k) Single phase preventer, over load relays of suitable rating- 03 Nos(l) Voltmeter 0-500 V digital type with selector switch - 1 No (m) Indicator lamp LED type - 3 Nos (R, Y & B)(n) Digital type meters ampere meter with suitable selector switch including suitable resin cast CTs of 500/5 A - 01 No |
| 14 | Supply, install, testing and commissioning, in repleacement, LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size to accomodate the following accessoriestotally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type madeof 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron (50 x 50 x 5 mm) frame work with four legs grouted in PCC (1:2:4) type B1(using 20mm graded crushed stone aggregate) as foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, duly powder coated with 200A electricalgrade copper bus bar for phases and neutral with colour coated insulator sleeves, including danger notice plate complete with suitable digital type meters resin cast CTs, CPRI approved, type tested, internal wiring all includingthe following incoming complete all as specified and directed:-Note:- Connection from Main bus bar to OutgoingMCCB shall be provided through bus bar of suitable rating instead of copper wires |
| 15 | (a) MCCB 4P 100 Amps rating, 50 Hz, 415 V with rupturing capacity 25 KA, adjustable type - 01 No (Incoming)(b) MCCB 4P 63 Amps rating, 50 Hz, 415 V with rupturing capacity 16 KA, adjustable type - 01 No (outgoing)(c) MCB TPN 20 Amps rating, C Curve, 415 V with rupturing capacity 10 KA - 01 No (outgoing)(d) MCB SPN 32 Amps rating, C Curve, 240 V with rupturing capacity 10 KA - 01 No (outgoing) (e) On load change over switch, 4 Pole, 160 Amps, 415 Volts - 01 No (f) Surge Protection Device (SPD), Three Pole and Neutral, Uc (V) 320 V, In (Ka) 20 kA, Imax (kA) 40 kA - 01 No (g) Fully automatic Motor Starter (Star-Delta) suitable for 25 HP submersible Pump set, 3 Phase - 01 No (h) Single phase preventer, over load relays of suitable rating - 01 No (j) Voltmeter 0-500 V digital type with selector switch - 1 No(k) Indicator lamp LED type - 3 Nos (R, Y & B) (l) Digital type ampere meter with suitable selector switch including suitable resin cast CTs of 200/5 A - 01 No :-Note:- 1. Panel board shall be manufactured from CPRI approved manufacturers only.2. Platform for panel should be 1.5 feet above average ground level.3. Connecting of existing UG cable to panel board shall be provided as per site requirement. |
| 16 | M & L in repair for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50 M deep below normal ground level, connected to galvanisedstrip of size 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore GI pipe medium grade including necessary fittings for protection of earthing strip upto 7.5 mtr length, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth strip alongwith protection pipe and testing on completion complete all as specified and directed. |
| 17 | Supply, fixing, lowering, testing and commissioning, in repleacement, Submersible pump set , electric driven, 415 Volts, 3 Phase, 50 Hz, Head not less than 120 Mtr, not less than 280 LPM suitable for existing bore well complete all as specified and directed.( Note :- Capacity of submersiblepump shall be decided as per yield test report of the bore.) |
| 18 | Supply, fixing, lowering, testing and commissioning, in repleacement, Submersible pump set, electric driven, 415 Volts, 3 Phase, 50 Hz, Head not less than 150 Mtr, not less than 300 LPM suitable for existing bore well complete all as specified and directed.( Note :- Capacity of submersiblepump shall be decided as per yield test report of the bore.) |
| 19 | Supply, fixing, lowering, testing and commissioning, in repleacement, Submersible pump set , electric driven, 415 Volts, 3 Phase, 50 Hz, Head not less than 150 Mtr, not less than 350 LPM suitable for existing bore complete all as specified and directed(Note :- Capacity of submersiblepump shall be decided as per yield test report of the bore.) |
| 20 | Supply, fixing, lowering, testing and commissioning, in repleacement, Submersible pump set , electric driven, 415 Volts, 3 Phase, 50 Hz, Head not less than 150 Mtr, not less than 350 LPM suitable for existing bore complete all as specified and directed.( Note :- Capacity of submersiblepump shall be decided as per yield test report of the bore.) |
| 21 | Supply, fixing, lowering, testing and commissioning in repleacement, Submersible pump set , electric driven, 415 Volts, 3 Phase, 50 Hz, Head not less than 160 Mtr, not less than 350 LPM suitable for existing bore complete all as specified and directed.(Note :- Capacity of submersiblepump shall be decided as per yield test report of the bore.) |
| 22 | Supply, fixing, installation, testing and commissioning, in repleacement, Centrifugal pump set of size 12.5 HP, electric driven, 415 Volts, 3 Phase, 50 Hz complete all as specified and directed. Note:-Pump set obtained from above items shall be deposited at MES Yard by the contractor without any extra cost to the Government. |
| 23 | Supply, lowering and fixing, in repleacement, MS column pipe, ISI marked,both end threaded type, 80 mm dia bore in 3 mtr length,heavy grade,as per IS-1239 complete with andincludingMS socketetccomplete all as specified and directed. |
| 24 | Supply, lowering and fixing, in repleacement, MS column pipe, ISI marked,both end threaded type, 100 mm dia bore in 3 mtr length,heavy grade,as per IS-1239 complete with andincludingMS socketetccomplete all as specified and directed by Engr-in-Charge. |
| 25 | Supply, install, test and commissioning, in repleacement, submersible pump starter fully automatic star delta starter in sheet metal enclosure type MUG-20 mortar, 28 to 42 Amp relay max. range rating AC 3 Phase 415 Volt 50 HZ conforming to IS/ IEC : 60947-41 protection offered overload single phasing, phase reversal, phase imbalance, auto restart features vibration proof enclosure with IP-54 protection class indications offered ON/ OFF voltage and Ampere complete all as specified and as directed. |
| 26 | Supply, install, test and commissioning, in repleacement, submersible pump starter fully automatic star delta starter in sheet metal enclosure type MUG-30 mortar, 30 to 50 Amp relay max. range rating AC 3 Phase 415 Volt 50 HZ conforming to IS/ IEC : 60947-41 protection offered overload single phasing, phase reversal, phase imbalance, auto restart features vibration proof enclosure with IP-54 protection class indications offered ON/ OFF voltage and Ampere complete all as specified and as directed. |
| 27 | Supply, install, test and commissioning, in repleacement, submersible pump starter fully automatic star delta starter in sheet metal enclosure type MUG-40 mortar, 30 to 50 Amp relay max. range rating AC 3 Phase 415 Volt 50 HZ conforming to IS/ IEC : 60947-41 protection offered overload single phasing, phase reversal, phase imbalance, auto restart features vibration proof enclosure with IP-54 protection class indications offered ON/ OFF voltage and Ampere complete all as specified and as directed. |
| 28 | Supply & fix,, in replacement, Cast iron sluice valve, ISI Marked 200 mm bore flanged of class 1.6 PN having spindle made out of gun metal (Brass type), operating wheel nuts, bolts, packing complete all as specified and directed. |
| 29 | Supply & fix, in replacement, Cast iron sluice valve, ISI Marked 150 mm bore flanged of class 1.6 PN having spindle made out of gun metal (Brass type), operating wheel nuts, bolts, packing complete all as specified and directed. |
| 30 | Supply & fix, in replacement, Cast iron sluice valve, ISI Marked 100 mm bore flanged of class 1.6 PN having spindle made out of gun metal (Brass type), operating wheel nuts, bolts, packing complete all as specified and directed. |
| 31 | Supply & fix, in replacement, Acrylic letters Glow Sign Board (latest LED type) of various Pump Houses complete all as specified and directed. |
| 32 | Excavationin trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in hard/dense soil complete all as specified and directed. |
| 33 | Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. |
| 34 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 35 | Supply and layingsub class B fly ash bricks , laid flat dry, in trenches with width equal to the length of the bricks, laid perpendicularto the axis of cable for cable protection complete all as specified and as directed. |
| 36 | Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23 cm (15 cm under the cable & 8 cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. ( Note : Punned thickness shall be considered for payment purpose) |
| 37 | Supply and laying, in repleacement, GI steel tubing medium grade, laid in tranches/wall/floor and joined including necessary fittings such as bends, elbow, tees sockets etc including necessary saddles and clamps of 40 mm bore complete all as specified and directed. |
| 38 | Supply and laying, in repleacement, GI steel tubing medium grade, laid in tranches/wall/floor and joined including necessary fittings such as bends, elbow, tees sockets etc including necessary saddles and clamps of 100 mm bore complete all as specified and directed. |
| 39 | Drilling (Horizontally) to existing road (maximum 10M wide) suitable for passing GI tubing of dia upto 80 mm as required at site complete all as specified and directed.Note:- All necessary T&P required at site for drilling shall be arranged by contractor at his own cost and quoted rate shall be deemed to be included for all these provisions and nothing extra shall be paid on this account. |
| 40 | Schedule of credit amount of Rs 1,59,340.00 to be deducted during AOC |