| 1 | Carrying outOil Servicing & DG General Checkup work including supplying of Oil filters andfuel filters |
| 2 | Lub Oil sevicing for Engine (7.5 KVA) |
| 3 | Lub Oil sevicing for Engine (10 to 15 KVA) |
| 4 | Lub Oil sevicing for Engine (20 to 40 KVA) |
| 5 | Lub Oil sevicing for Engine (40 to 63 KVA) |
| 6 | Service charges for carrying out the Oil servicing and DG general checkup work including labour charges , sundries etc. complete as required for DG capacities 7.5 KVA to 63 KVA. |
| 7 | Supply of Air Filter Assembly along with Air filter hose clips |
| 8 | For 7.5 KVA Engine |
| 9 | For 10 to 15 KVA Engine |
| 10 | For 20 to 40 KVA Engine |
| 11 | For >40 to 63 KVA Engine |
| 12 | Cleaning and fitting air filter up to 40 KVA |
| 13 | Cleaning and fitting air filter from >40 to 63 KVA |
| 14 | Service charges for replacement of air filter assembly i/c labour charges , sundries etc. complete as required for DG capacities 7.5 KVA to 63 KVA. |
| 15 | Supplyingof appropriate grade V Belt |
| 16 | 7.5 KVA |
| 17 | 10 to 15 KVA |
| 18 | 20 to 40 KVA |
| 19 | > 40 to 63 KVA |
| 20 | Service charges for replacement of V-Belt including labour charges , sundries etc. complete as required for DG capacities 7.5 KVA to 63 KVA. |
| 21 | Supplying of appropriate steel braided rubber Hoses with Banjo Bolts. |
| 22 | Stainless Steel Braided rubber hose with banjo (18\") |
| 23 | StainlessSteel Braided rubber hose with banjo (24\") |
| 24 | StainlessSteel Braided rubber hose with banjo (36\") |
| 25 | Supply of 1/2 \" High Pressure MS Pipe for fuel line including accessories such as bends , elbows etc. complete as required. |
| 26 | Service charges for replacement of stainless steel braided hoses with banjo, including labour charges , sundries etc. complete as required for DG capacities 7.5 KVA to 63 KVA. |
| 27 | Service charges for laying of High pressure MS fuel pipes of sizes suitable for 7.5 KVA to 63 KVA capacities. |
| 28 | Supplying and fixing of LLOP sensor and its accessories for DG sets of capacity7.5 KVA to 63KVA including labour charges and sundries etc. complet as required. |
| 29 | Supplying and fixing of reputed make mechanical type Hour meter for DG sets i/c accessories and labour charges for fixing etc. complete as required. |
| 30 | Supplying and fixing of heavy grade Door hinges including removing the defective hinges and making the canopy safe and secure complete as required. |
| 31 | Carrying out the repairs to the self starter by replacing the faulty Bendix assembly with a new one including dismantling from the DG set, refixing back to the DG set after replacement etc. complete as required including all accessories,sundries and labour charges complete as required. |
| 32 | 7.5 KVA to 40 KVA |
| 33 | >40 KVA to 63 KVA |
| 34 | Carrying out the repairs to the self starter by replacing the faulty Solenoid switch with a new one including dismantling from the DG set, refixing back to the DG set after replacement etc. complete as required including all accessories,sundries and labour charges complete as required. |
| 35 | 7.5 KVA to 40 KVA |
| 36 | >40 KVA to 63 KVA |
| 37 | Carrying out the repairs to the self starter by replacing the faulty armature unit for the self starter with a new one including dismantling from the DG set, refixing back to the DG set after replacement etc. complete as required including all accessories,sundries and labour charges complete as required. |
| 38 | 7.5 KVA to 40 KVA |
| 39 | >40 KVA to 63 KVA |
| 40 | Carrying out the repairs to the self starter by replacing the faulty Carbon brush base and bushes(self starter) with a new one including dismantling from the DG set, refixing back to the DG set after replacement etc. complete as required including all accessories,sundries and labour charges complete as required. |
| 41 | 7.5 KVA to 40 KVA |
| 42 | >40 KVA to 63 KVA |
| 43 | Carrying out the repairs to the self starter by replacing the faulty Starter ring (Crank Gear) with a new one including dismantling from the DG set, refixing back to the DG set after replacement etc. complete as required including all accessories,sundries and labour charges complete as required. |
| 44 | 7.5 KVA |
| 45 | 10 to 15 KVA |
| 46 | 20 to 40 KVA |
| 47 | >40 to 63 KVA |
| 48 | Supplying and fixing of the New Stop solenoid Assembly suitable for the DG set of capacity 7.5 KVA to 63 KVA i/c labour charges for fixing etc. complete as required. |
| 49 | Supplying and fixing of the New Thermostat with assembly Suitable for the DG set of below said capacity i/c labour charges for fixing etc. complete as required. |
| 50 | 7.5 KVA |
| 51 | 10 to 15 KVA |
| 52 | 20 to 40 KVA |
| 53 | >40 to 63 KVA |
| 54 | Attending repairs to the Exhaust Fan |
| 55 | Fan motor coil rewinding |
| 56 | Capacitor for exhaust fan |
| 57 | bearings for exhaust fan |
| 58 | Fan leaf Assembly |
| 59 | Service charges for dismantling, re fixing the Fan and restoring the DG in good working condition. |
| 60 | Supplying of New Radiator Assembly for replacing faulty radiator |
| 61 | 7.5 KVA |
| 62 | 10 to 15 KVA |
| 63 | 20 to 40 KVA |
| 64 | >40 to 63 KVA |
| 65 | Service charges for replacing faulty radiator by new radiator and restoring the DG in good working condition |
| 66 | Attending to the repairs of the radiator including de-scaling, de-greasing, arresting leakages in the existing radiator i/c labour charges complete as reqd. |
| 67 | 7.5 KVA |
| 68 | 10 to 15 KVA |
| 69 | 20 to 40 KVA |
| 70 | >40 to 63 KVA |
| 71 | Supplying and fixing of Radiator hose and hose clips completre as required i/c labour charges. |
| 72 | 7.5 KVA |
| 73 | 10 to 15 KVA |
| 74 | 20 to 40 KVA |
| 75 | >40 to 63 KVA |
| 76 | Supplying new Water Pump Assembly for replacing faulty Water Pump Assembly i/c accessories, labour charges etc complete as required. |
| 77 | 7.5 KVA |
| 78 | 10 to 15 KVA |
| 79 | 20 to 40 KVA |
| 80 | >40 to 63 KVA |
| 81 | Service charges for replacing faulty water Pump Assembly by new Water Pump Assembly and restoring the DG in good condition |
| 82 | Supplying of New Radiator fan for replacing faulty Radiator Fan i/c all accessories , sundries etc. completre as required. |
| 83 | 7.5 KVA |
| 84 | 10 to 15 KVA |
| 85 | 20 to 40 KVA |
| 86 | >40 to 63 KVA |
| 87 | Service charges for replacing faulty Radiator fan by new Radiator Fan and restoring the DG in good working condition. |
| 88 | Supplying of New Anti Vibration (AV) Mounting bushes for the DG set |
| 89 | 7.5 KVA |
| 90 | 10 to 15 KVA |
| 91 | 20 to 40 KVA |
| 92 | >40 to 63 KVA |
| 93 | Service charges for arresting Vibration by installing AV Mounting bushes. |
| 94 | Coil rewinding and repairing work in respect of Alternator of DGs of 7.5 KVA, including dismantling from the DG set, to and fro transportation to the workshop, checking of allignment after installation etc. complete as required. |
| 95 | Main Field Coil (Rotor) Winding i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material. |
| 96 | Main Armature Coil (Stator) Winding (7.5 KVA) i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material. |
| 97 | Auxiliary Field Winding (7.5 KVA, Stator) i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material. |
| 98 | Armature Auxiliary Field (Rotor auxiliary field) Winding (7.5 KVA) i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material. |
| 99 | Coil rewinding and repairing work in respect of Alternator of DGs of 11 to 15 KVA,including dismantling from the DG set, to and fro transportation to the workshop, checking of allignment after installation etc. complete as required. |
| 100 | Main Field Coil (Rotor) Winding i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material. |
| 101 | Main Armature Coil (Stator) Winding i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material |
| 102 | Auxillary stator coil i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material. |
| 103 | Auxiliary Rotor Field Winding i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material. |
| 104 | Coil rewinding and repairing work in respect of Alternator of DGs capacity 20 to 30 KVA,including dismantling from the DG set, to and fro transportation to the workshop, checking of allignment after installation etc. complete as required. |
| 105 | Main Field Coil (Rotor) Winding i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material. |
| 106 | Main Armature Coil (Stator) Winding i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material |
| 107 | Auxillary stator coil i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material. |
| 108 | Auxiliary Rotor Field Winding i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material. |
| 109 | Coil rewinding and repairing work in respect of Alternator of DGs of 40 to 63 KVA,including dismantling from the DG set, to and fro transportation to the workshop, checking of allignment after installation etc. complete as required. |
| 110 | Main Field Coil (Rotor) Winding i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material. |
| 111 | Main Armature Coil (Stator) Winding i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material |
| 112 | Auxillary stator coil i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material. |
| 113 | Auxiliary Rotor Field Winding i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material. |
| 114 | Slip ring and carbon brush assembly i/c labor charge |
| 115 | Compounding transformer rewinding I/c labor charge |
| 116 | Supplying and fixing of the following Alternator Spares i/c labour charges etc. complete as required. |
| 117 | Bearing (7.5 KVA) |
| 118 | Bearing (10 to 15 KVA) |
| 119 | Bearing (20 to 40 KVA) |
| 120 | Bearing (>40 to 63 KVA) |
| 121 | Rotating Rectifier (Diode) 7.5 KVA to 40 KVA i/c labor charge |
| 122 | Rotating Rectifier (Diode) >40 KVA to 63 KVA i/c labor charge |
| 123 | Supplying and fixing of Automatic voltage regulator for DG sets of capacity 7.5 KVA to 63 KVA I /c all accessories and labour charges etc. complete as required. |
| 124 | Supplying and fixing of the following spare Components along with accessories i/c labour charges complete etc. as required. |
| 125 | MCCB(32 A, 4 Pole) for 15/20 KVA |
| 126 | MCCB (63A, 4 pole) for 40 KVA |
| 127 | MCCB (100A, 4 pole) for 63 KVA |
| 128 | Start/Stop push button assembly |
| 129 | Battery charger SMPS (12V, 10 A) |
| 130 | DC Start/Stop Relay |
| 131 | Single pole MCB up to 32 A |
| 132 | 3 Phase 4 Pole 32A Contactor (Coil 230 V AC) |
| 133 | 63A, 4 Pole, 4 Way Rotary change over switch |
| 134 | 32A, 4 Pole MCB |
| 135 | AVR (Stabilizer) up to 300 VA (for EB contactor coil) |
| 136 | Service Charges |
| 137 | Repairing charges of SMPS / Conventional Battery Charger (12V, 10A) |
| 138 | Patch up work in rusted parts of Canopy of DG by 1mm thick GI sheet fastened using pop rivet and sealing using metal sealer for leak proof. |
| 139 | Attending minor faults in AMF controller (such as Relay failure, Transistor failure, Display failure) |
| 140 | Service charges for repairing the faulty fuel pump |
| 141 | Service charges for repairing the faulty Injector/ Pump Nozzle |
| 142 | Service charges for repairing the faulty Cylinder Head |
| 143 | Service charges for attending the faulty Gasket Set Piston ring/Inlet & outlet gasket |